Search NASA⌕ Search

SEARCH · Search NASA

Results for “diameter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Viscous flow properties and hydrodynamic diameter of phenothiazine-based redox-active molecules in different supporting salt environments

We report viscous flow properties of a redox-active organic molecule, N-(2-(2-methoxyethoxy)ethyl)phenothiazine (MEEPT), a candidate for non-aqueous redox flow batteries, and two of its radical cation salts. A microfluidic viscometer enabled the use of small sample volumes in determining viscosity as a function of shear rate and concentration in the non-aqueous solvent, acetonitrile, both with and without supporting salts. All solutions tested show Newtonian behavior over shear rates of up to 30 000 s−1, which was rationalized by scaling arguments for the diffusion-based relaxation time of a single MEEPT molecule without aggregation. Neat MEEPT is flowable but with a large viscosity (412 mPa⋅s at room temperature), which is ∼1000 times larger than that of acetonitrile. MEEPT solutions in acetonitrile have low viscosities; at concentrations up to 0.5 M, the viscosity increases by less than a factor of two. From concentration-dependent viscosity measurements, molecular information was inferred from intrinsic viscosity (hydrodynamic diameter) and the Huggins coefficient (interactions). Model fit credibility was assessed using the Bayesian Information Criterion. It is found that the MEEPT and its charged cations are “flowable” and do not flocculate at concentrations up to 0.5 M. MEEPT has a hydrodynamic diameter of around 8.5 Å, which is almost insensitive to supporting salt and state of charge. This size is comparable to molecular dimensions of single molecules obtained from optimized structures using density functional theory calculations. The results suggest that MEEPT is a promising candidate for redox flow batteries in terms of its viscous flow properties.

Wang, Yilin (ORCID:0000000316102995)↗

Convenient analytical formula for cluster mean diameter and diameter dispersion after nucleation burst

Here, we propose an alternative method of estimating the mean diameter and dispersion of clusters of particles, formed in a cooling gas, right after the nucleation stage. Using a moment model developed by Friedlander [S. K. Friedlander, Ann. N. Y. Acad. Sci. 404, 354 (1983)], we derive an analytic relationship for both cluster mean diameter and diameter dispersion as a function of two of the characteristic times of the system: the cooling time and the primary constituents collision time. These formulas can be used to predict diameter and dispersion variation with process parameters, such as the initial primary constituents' concentration or cooling rate. It is also possible to use them as an input to the coagulation stage, without the need to compute complex cluster generation during the nucleation burst. We compared our results with a nodal code (NGDE) and got excellent agreement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamic Differential Image Circle Diameter Measurement Precision Assessment: Application to Burning Droplets

Dynamic measurement precision assessment has been achieved for a differential circle measurement application. Differential circle diameter measurement, in image analysis, typically requires fitting a circle model that optimizes for image distortions, defects or occlusions. The differential task occurs when precise measurements of diameter change are required given object size variation with time. An automated system was designed to provide diameter measurements and associated measurement precision of images of a fuel droplet undergoing combustion in zero gravity for the FLEX-2 dataset. An image gradient-based, least-squares boundary point fitting method to a circle or ellipse model is used for diameter measurement. The presence of soot aggregates poses significant challenges for diameter measurements when it occludes part of the droplet boundary. The precision of the diameter measurements depends upon the image quality. Using synthetic image simulations that model the soot behavior, we developed a model based on image quality measures that assesses the measurement precision for each individual diameter measurement. Thus, diameter measurements with precision assessments were made available for follow-up scientific analysis. As a result, the algorithm's success rate for measurable runs was 98%. In cases of limited occlusion, a measurement precision of ±0.2 pixels for the FLEX-2 dataset was achieved.

42 ENGINEERING↗

Effects of Riser Diameter on Solids Holdup and Particle Velocity Profiles in Circulating Fluidized Bed Riser Systems

Tests were performed in a 0.1-m diameter small circulating fluidized bed (SCFB) and 0.3 m diameter cold flow circulating fluidized bed (CFCFB) riser systems located at the National Energy Technology Laboratory (NETL) to study the effects of riser diameter on the riser hydrodynamics. These tests were performed at solids circulation rates of G s = 20 and 75 kg/m 2 s and superficial gas velocities of U g = 5.8 and 6.5 m/s using high-density polyethylene (HDPE) pellets with a density of 0.863 g/cm 3 , particle size range of 600–1400 µm (with a Sauter mean diameter of 871 µm, placing them in the Geldart B classification). Comparisons of riser axial pressure and solids fraction profiles, radial particle velocity profiles, and radial profiles of higher statistical moments and select chaos analysis parameters were considered. The results showed that for a given U g and G s , the smaller diameter riser exhibited characteristics associated with more dilute solids flow than that observed in the larger diameter riser. Additionally, the larger diameter riser exhibited a downward flow of solids near the wall under all test conditions, whereas the smaller diameter riser data exhibited little or no indications of solids downflow near the wall. Overall, these findings suggest that, from an industrial standpoint, a direct scaleup of small-scale tests cannot readily be accomplished as the solids holdup and the solids velocity profiles in small units (those normally tested in the laboratory) are not similar to those of large units and the performance of large units can therefore not be predicted from small-scale tests.

42 ENGINEERING↗

Demonstration of a MOT in a sub-millimeter membrane hole

Abstract We demonstrate the generation of a cold-atom ensemble within a sub-millimeter diameter hole in a transparent membrane, a so-called “membrane MOT”. With a sub-Doppler cooling process, the atoms trapped by the membrane MOT are cooled down to 10 $$\upmu$$ μ K. The atom number inside the unbridged/bridged membrane hole is about $$10^4$$ 10 4 to $$10^5$$ 10 5 , and the $$1/e^2$$ 1 / e 2 -diameter of the MOT cloud is about 180 $$\upmu$$ μ m for a 400 $$\upmu$$ μ m-diameter membrane hole. Such a membrane device can, in principle, efficiently load cold atoms into the evanescent-field optical trap generated by the suspended membrane waveguide for strong atom-light interaction and provide the capability of sufficient heat dissipation at the waveguide. This represents a key step toward the photonic atom trap integrated platform (ATIP).

74 ATOMIC AND MOLECULAR PHYSICS↗

Integrating fine root diameter and watershed mapping to characterize rhizosphere hydrology

Root morphology and soil hydraulic characteristics were integrated using watershed distance mapping to show water distribution and uptake across the plant-soil interface. Poplar (Populus deltoides, P. trichocarpa), maize (Zea mays), juniper (Juniperus virginiana), grape (Vitis rotundifolia) and maple (Acer saccharum) seedlings were grown in sand, after which root diameter and soil water dynamics were assessed via sequential neutron radiography. Three local soil regions (root-soil interface or edge, rhizosphere, bulk soil) were classified based on both radial distance from the root surface and diameter of the nearest root, from which changes in water content and distribution were characterized using digital image processing. Water content dynamics across the rhizosphere showed two different species-independent processes: a consistently elevated water content at the root-soil edge interface which increased with root diameter, and hysteresis as the rhizosphere transitioned to bulk soil (~0.5 cm from the root), independent of root diameter. Water uptake per unit root surface area declined exponentially with root diameter, independent of species. Results highlight the species-independent hydrologic characteristics of the rhizosphere and the potential for evaluating them in a local spatially connected soil context. Avenues for improved integration of soil and root characteristics are discussed.

59 BASIC BIOLOGICAL SCIENCES↗

A Technique for Estimating Liquid Droplet Diameter and Liquid Water Content in Stratocumulus Clouds Using Radar and Lidar Measurements

This paper describes a technique for estimating the liquid water content (LWC) and a characteristic particle diameter in stratocumulus clouds using radar and lidar observations. The uncertainty in LWC estimate from radar and lidar measurements is significantly reduced once the characteristic particle diameter is known. The technique is independent of the drop size distribution. It is applicable for a broad range of W-band reflectivity Z between -30 and 0 dBZ and all values of lidar backscatter β observations. No partitioning of cloud or drizzle is required on the basis of an arbitrary threshold of Z as in prior studies. A method for estimating droplet diameter and LWC was derived from the electromagnetic simulations of radar and lidar observations. In situ stratocumulus cloud and drizzle probe spectra were input to the electromagnetic simulation. The retrieved droplet diameter and LWC were validated using in situ measurements from the southeastern Pacific Ocean. The retrieval method was applied to radar and lidar measurements from the northeastern Pacific. Uncertainty in the retrieved droplet diameter and LWC that are due to the measurement errors in radar and lidar backscatter measurements are 7% and 14%, respectively. The retrieved LWC was validated using the concurrent G-band radiometer estimates of the liquid water path.

54 ENVIRONMENTAL SCIENCES↗

Fast Water Transport through Subnanometer Diameter Vertically Aligned Carbon Nanotube Membranes

Small-diameter carbon nanotubes (CNTs) have outstanding mass-transport properties, especially enhanced water flow. Here, we report on water transport through the first macroscopic membranes with vertically oriented, subnanometer (0.8 nm) CNT pores, made by a scalable, solution-based method with electric-field alignment of bulk-grown single-wall CNTs (SWCNTs). After plasma etching to open pores, vertically aligned CNTs served as the primary pathway for liquid-water transport. The CNT membranes showed fast pressure-driven water transport, with up to 105-fold enhancement compared to no-slip Hagen–Poiseuille flow. Comparing 0.8 and 3 nm CNTs, we found that the hydrodynamic slip lengths increased with decreasing nanotube diameter, reaching 8.5 μm for the smaller-diameter CNTs. Here, the results suggest that pressure-driven water transport in small-diameter CNTs is increasingly dominated by entrance resistance, thus becoming independent of nanotube length. Scalably fabricated membranes incorporating vertically aligned subnanometer CNT pores could have applications in water filtration, desalination, and energy harvesting.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Uncovering the Relationship between Diameter and Height of Electrodeposited Lithium Protrusions in a Rigid Electrolyte

A promising approach for enabling rechargeable batteries with significantly higher energy densities than current lithium-ion batteries is by deploying lithium-metal anodes. However, the growth of lithium protrusions during charging presents significant challenges. Since these protrusions are often branched and filamentous in conventional liquid electrolytes, this problem is referred to in the literature as the “dendrite problem”. While solid electrolytes have the potential to solve this problem, protrusions grow in all electrolytes when the current density exceeds a critical value. Fundamentally understanding the formation is necessary to develop a rational approach for increasing the critical current density, but it is challenging due to the complex interplay between electrochemical and material properties. The diameters and heights of protrusions on lithium-metal anodes stabilized by a rigid block copolymer electrolyte were measured in situ by synchrotron hard X-ray microtomography. The diameter of the shorting protrusions increased linearly with increasing electrolyte thickness. Further, a universal linear relationship between protrusion height and diameter of both shorting and non-shorting protrusions was observed. A model based on the concentrated solution theory was used to establish the electrochemical and mechanical sources for our observations. Here, the computational analysis indicates that elastic and plastic deformation of both the lithium metal and the polymer are important to describe protrusion growth. Both stress-induced current density effects due to the deformation of the electrolyte near the protrusion and plastic deformation of lithium metal combine to give the counterintuitive result: the fastest-growing protrusions have the largest diameter.

25 ENERGY STORAGE↗

Nanopores with dynamic pore opening diameter

Solid state nanopores have emerged as model systems for understanding transport properties on the nanoscale. They serve as templates for both preparing mimics of biological channels and designing biological sensors. Unlike their biological inspirations, the majority of nanopores prepared thus far, however, have been structurally static devices such that the pore opening diameter is fixed. If we could prepare nanopores whose opening diameter fluctuated in time with controlled amplitude at known locations in the pore, we could create ionic memristors as well as achieve new transport modes. Here we present ∼10 nm diameter single nanopores drilled through a 10 nm thick gold layer positioned on top of a 30 nm thick silicon nitride film. Two types of devices were prepared; one containing single stranded DNA and the other containing hairpin DNA attached to the discrete layer of gold using thiol chemistry. When an external electric field was applied across a nanopore with single stranded DNA, the nanoconfined DNA molecules exhibited steric and electrical constraints that led to memristor-like behavior in the current–voltage curves. The degree of hysteresis was controlled by salt concentration, magnitude of voltage and pore diameter. In contrast, nanopores containing DNA hairpins conducted similar currents in forward and reverse bias in agreement with the rigidity of the hairpin molecule. The experiments are explained by Brownian dynamics simulations that reveal voltage and salt concentration induced changes in DNA extension. The degree of DNA extension was also found to be dependent on the location of the molecules along the pore axis. The nanopores presented here provide the first steps towards preparation of non-equilibrium nanopore systems.

Vlassiouk, Ivan [ORNL] (ORCID:0000000254940386)↗

Delayed Critical and Subcritical Experiments with Polyethylene Moderated Unreflected Thin 15 in. Diameter HEU Metal Plates

The thin ~15 in. diameter highly enriched uranium (HEU) metal plates were assembled to delayed criticality at the Oak Ridge Critical Experiments Facility (ORCEF) in 1969 with various thicknesses of polyethylene (varying from 1/16 to 2$\frac{3}{8}$ inches) between uranium metal plates. The average 235 U enrichment was 93.27 wt. %. These unreflected critical configurations contained 4$\frac{2}{3}$ to 20$\frac{5}{6}$ thin 15 in. diameter HEU metal plates (on loan from Los Alamos National Laboratory [LANL] and shipped to Oak Ridge National Laboratory [ORNL] on June 3, 1969). Depending on the thickness of polyethylene, the enriched uranium masses varying from 28,053 to 135,148 grams. Fractional plate sections consisted of the appropriate number of 60° pie sections. In addition to the measurement at delayed criticality, subcritical measurements were also performed by the inverse kinetic rod drop method. Prompt neutron decay constant measurements were also performed by the Rossi alpha and randomly pulsed neutron method using a time-tagged spontaneous fission californium neutron source; these are briefly reported here. At the time of these measurements in 1969, the thin HEU metal plates were in near-pristine condition with extremely little oxidation, allowing better descriptions of the uranium plates than the use of these plates in a heavily oxidized and deteriorated condition in recent reflected benchmark experiments at the LANL facility at the Nevada Test Site with these same thin highly enriched uranium metal plates. This report documents the experimental information for the measurements performed so that later researchers can perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Evaluation Program (ICSBEP) or a Nuclear Energy Agency (NEA) benchmark. Data from the experiments described should be acceptable for use as criticality safety benchmark experiments for the ICSBEP and the NEA nuclear criticality safety benchmark program once the uncertainty analysis on the measured neutron multiplication factors is completed. Additional data—such as the dimensional inspection reports, uranium isotopic information, and other relevant particulars—should be retrieved from the Y-12 Plant or LANL and incorporated in the final ICSBEP benchmark. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainties in $k_{eff}$ could be as low as ± 0.0002 for some configurations. Other experiments with smaller-diameter than 15 in. diameter HEU metal plates have been benchmarked in HEU-METFAST-001. The prompt neutron time decay measurements could be the basis for an International Reactor Physics Benchmark Program. Preparation of the present report is part of an effort at ORNL to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other US Department of Energy critical experiments facilities using more than 500 operational days of critical facility time. This work for this report publication was supported by the Nuclear Criticality, Radiation Transport and Safety NCSP Program at ORNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Specification of EBR-II Fabricated Fuel Diameter Data

All IFR EBR-II fuel pins were fabricated at one of the related fuel fabrication facilities at Argonne National Laboratory-West, at the EBR-II site [1]. U-Pu-Zr experimental pins were fabricated at the Experimental Fuels Laboratory (EFL), which was established in April of 1984 after the positive acceptance of the IFR concept, while the U-Zr experimental pins were fabricated at the Fuel Manufacturing Facility (FMF), along with the driver fuel pins [2]. The injection-casting fabrication process is described in detail in ref [1]. All the fuel pins that were loaded into EBR-II were examined after fabrication to ensure that they met the design dimensional requirements and tolerances prior to assembly. Fuel slug diameter was measured with either a laser profilometer (at FMF) or a hand micrometer (at EFL), at a minimum of 1-inch intervals over the length of the fuel slug, as shown in Figure 1 [2]. In all cases the average fuel diameter is reported, in some cases with additional summary statistics (e.g., minimum, maximum), and in rare cases the complete record of axially-varying fuel diameters is available. It should be noted that in cases where axial varying data is available, in general the orientation of the slug was not recorded or carried over to loading of the pin, so a diameter measurement at the bottom of the fabricated slug does not necessarily correspond to the bottom of the loaded slug, as it may have been loaded in either orientation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Specifications of Cladding Diameter Measurements Conducted at AGHCF

Fuel element diameter data was collected on-site at the Alpha-Gamma Hot Cell Facility (AGHCF) before and after out-of-pile furnace transient tests of fuel elements. Available data records have been collected and preserved in the Out-of-Pile Transient Database (OPTD). This data is used to determine the transient-induced changes in fuel element diameter, or cladding strain, for the Whole Pin Furnace (WPF) tests. Fuel element diameter was measured by contact profilometry along the length of the fuel pin at specified rotational orientations and/or by a manually operated micrometer at several discrete axial locations along the pin. The Alpha-Gamma Hot Cell Facility Operations Manual details the way the facility operated, organizational and oversight responsibilities, and procedures for examination of samples. The working version of the manual at the time of the whole pin furnace tests and the test pin examinations is Doc. No. IPS-2-00-00, dated June 1989. This specification was developed using the operations manual and recovered measurement records in consultation with subject matter experts (SMEs). The measurement methods, format of the available post-test examination (PTE) data, and recommended methods for use and interpretation of that data are summarized. Section 2 describes the available diameter measurement data for the WPF tests with guidance for interpretation and usage, and Section 3 describes the instrument measurement procedures and calibration methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reduction of Radiographic Spot Size with Dual Diameter Sub-mm Rods

Among the most dominant factors in x-ray radiographic image resolution is the radiographic spot size, which is primarily a function of the physical extent of the x-ray source, so the most marked improvements in image resolution come from modifying the pulse power driver’s diode configuration to reduce that extent. The smaller the size of the x-ray spot, the higher the image resolution potential. The U.S. Naval Research Laboratory’s Mercury pulsed power accelerator has been configured with a rod-pinch diode, and recent measurements were conducted to demonstrate the impact of anode rod geometry on x-ray spot size. The “standard” anode rod is a 0.75 mm diameter cylinder that is tapered down to 0.25 mm over a length of 5 mm, and, in this study, it was replaced by rods with a sharp step between their two diameters, rather than a taper. The effect on spot size was assessed by analyzing the edge and line spread functions calculated from high-mag rolled edge and pinhole camera images. For certain diameter pairs, a reduction in radiographic spot size is observed. In addition, the dual-diameter rods have provided unique insight into the electron-anode coupling dynamics that are at play in all diodes of this type.

X-ray radiography, spot size↗

Hexagonal Boron Nitride: Physical Properties, Hydride Vapor‐Phase Epitaxy Growth of Large‐Diameter Quasi‐Bulk Wafers and Applications

Hexagonal boron nitride ( h ‐BN), with its ultrawide bandgap and 2D structure, holds an immense promise for advanced semiconductor applications. Scaling bulk crystals to large‐diameter wafers, crucial for complex device fabrication, remains a challenge with high temperature, high pressure, and metal flux solution methods. To address this, recent efforts have focused on hydride vapor‐phase epitaxy (HVPE) for producing large diameter thick h ‐BN quasi‐bulk wafers, reaching hundreds of micrometers. These HVPE‐grown quasi‐bulk crystals exhibit excellent c ‐axis long‐range order. Notably, the in‐plane mobility‐lifetime products for both electrons and holes surpass 10 −4 cm 2 V −1 , which are two orders of magnitude greater than the out‐of‐plane (vertical) values, highlighting the potential for high‐performance devices leveraging superior lateral transport. Lateral detectors fabricated from 100 μm thick B‐10 enriched h‐ BN wafers have achieved a record 60% thermal neutron detection efficiency. Based on its physical properties, h‐ BN appears to be an outstanding material of choice for light‐triggered electronic power switches capable of supporting high ‐ voltage and high ‐ power operations. These recent advancements in large‐diameter h ‐BN quasi‐bulk crystal growth, enabled by HVPE, pave the way for applications spanning deep UV photonics, high‐power electronics, high‐efficiency neutron detection, and quantum information technologies, establishing h ‐BN as both a versatile active semiconductor and an ideal substrate.

Jiang, Hongxing [Department of Electrical and Comp↗

Advanced high-performance large diameter Cs 2 HfCl 6 (CHC) and mixed halides scintillator

This paper reports on successful growth and performance evaluation of two large diameter Cs 2 HfCl 6 (CHC) and Cs 2 HfCl 4 Br 2 (CHCB), both recently developed scintillator crystals. The discovery of Cs 2 HfCl 6 (CHC) as a scintillator has lately generated much interest in this material and its family, which belongs to the K 2 PtCl 6 cubic crystal structure. CHC is an intrinsic scintillator that is non-hygroscopic (slightly deliquescent, i.e., slightly moisture sensitive but does not deteriorate much when left in air), has no self-radioactivity, provides excellent energy resolution, and has excellent non-proportionality. CHC has a moderate density of 3.9 g/cm 3 and an effective atomic number of 58. Reported in this paper are transparent crack-free single crystal CHC and CHCB boules of one inch in diameter, both grown using the vertical Bridgman method. Samples retrieved from the boules, sized 23 mm × 30 mm and 23 mm × 26 mm, respectively, are characterized for their optical and scintillation properties. Energy resolutions of 3.5% and 3.7% (FWHM) at 662 keV, respectively, are reported. Light yields of 23,000 ph/MeV and 20,000 ph/MeV have been calculated for the large diameter CHC and CHCB crystals, respectively. Results comparable to previously reported results for smaller crystals have been obtained. Studies on decay time, non-proportionality, as well as detector characterization are also reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of Wire Diameter and Filament Size on the Processing Window of Bi-2212 Round Wire

High engineering critical current density (J E of 1300 A/mm 2 at 4.2 K and 15 T) in Bi-2212 round wire has been achieved through a partial melt, overpressure heat treatment process. J E varies strongly with processing conditions, particularly the maximum heat treatment temperature (T max ). Increasing T max results in longer time in the melt (defined as the time between when Bi-2212 melts on heating and when Bi-2212 begins to form on cooling), more bridging between the filaments, lower J E , and higher ac losses. A wide processing window with a large range of T max that has a nearly constant J E is desired for processing large coils with large thermal mass and significant thermal time constants that may make precise control over the desired temperature – time profiles uncertain. Accordingly, we wanted to explore broadening the T max window by controlling the Bi-2212 powder melting or wire architecture design. In this work, we report on studies of the performance variation with T max for two production wires with a filling factor of about 20% and 85 × 18 filaments where filament size was varied by changing the wire diameter, a process which also shortens the distance between filaments. We found that wires with smaller filament diameter (9 to 11 μm) showed a peak J E at the low end of T max and also a J E that was more sensitive to T max . A J E – T max plot showed a plateau J E (4.2 K, 5 T) of ~1100 A/mm 2 between T max of 886 and 894 °C for 1.0 and 1.2 mm wires, where J E is less sensitive to the wire diameter and T max . This J E plateau range is a preferred processing window for achieving high J E in coils.

36 MATERIALS SCIENCE↗

Overcoming the field-of-view to diameter trade-off in microendoscopy via computational optrode-array microscopy

High-resolution microscopy of deep tissue with large field-of-view (FOV) is critical for elucidating organization of cellular structures in plant biology. Microscopy with an implanted probe offers an effective solution. However, there exists a fundamental trade-off between the FOV and probe diameter arising from aberrations inherent in conventional imaging optics (typically, FOV < 30% of diameter). Here, we demonstrate the use of microfabricated non-imaging probes (optrodes) that when combined with a trained machine-learning algorithm is able to achieve FOV of 1x to 5x the probe diameter. Further increase in FOV is achieved by using multiple optrodes in parallel. With a 1 × 2 optrode array, we demonstrate imaging of fluorescent beads (including 30 FPS video), stained plant stem sections and stained living stems. Our demonstration lays the foundation for fast, high-resolution microscopy with large FOV in deep tissue via microfabricated non-imaging probes and advanced machine learning.

59 BASIC BIOLOGICAL SCIENCES↗