Search NASA⌕ Search

SEARCH · Search NASA

Results for “dielectric accelerating structures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A Reliability Model for Ni-BaTiO3-Based (BME) Ceramic Capacitors

The evaluation of multilayer ceramic capacitors (MLCCs) with base-metal electrodes (BMEs) for potential NASA space project applications requires an in-depth understanding of their reliability. The reliability of an MLCC is defined as the ability of the dielectric material to retain its insulating properties under stated environmental and operational conditions for a specified period of time t. In this presentation, a general mathematic expression of a reliability model for a BME MLCC is developed and discussed. The reliability model consists of three parts: (1) a statistical distribution that describes the individual variation of properties in a test group of samples (Weibull, log normal, normal, etc.), (2) an acceleration function that describes how a capacitors reliability responds to external stresses such as applied voltage and temperature (All units in the test group should follow the same acceleration function if they share the same failure mode, independent of individual units), and (3) the effect and contribution of the structural and constructional characteristics of a multilayer capacitor device, such as the number of dielectric layers N, dielectric thickness d, average grain size r, and capacitor chip size S. In general, a two-parameter Weibull statistical distribution model is used in the description of a BME capacitors reliability as a function of time. The acceleration function that relates a capacitors reliability to external stresses is dependent on the failure mode. Two failure modes have been identified in BME MLCCs: catastrophic and slow degradation. A catastrophic failure is characterized by a time-accelerating increase in leakage current that is mainly due to existing processing defects (voids, cracks, delamination, etc.), or the extrinsic defects. A slow degradation failure is characterized by a near-linear increase in leakage current against the stress time; this is caused by the electromigration of oxygen vacancies (intrinsic defects). The two identified failure modes follow different acceleration functions. Catastrophic failures follow the traditional power-law relationship to the applied voltage. Slow degradation failures fit well to an exponential law relationship to the applied electrical field. Finally, the impact of capacitor structure on the reliability of BME capacitors is discussed with respect to the number of dielectric layers in an MLCC unit, the number of BaTiO3 grains per dielectric layer, and the chip size of the capacitor device.

reliability↗

Design and development of a small structurally integrated ion thruster system

A 5 cm structurally integrated ion thruster has been developed for attitude control and stationkeeping of synchronous satellites. With 2-D vectorable grids, thrust is 0.56 mlb at a beam voltage of 1200 V, total mass efficiency is 64%, and electrical efficiency is 46.8%. Nonvectoring thrust of 0.41 is demonstrated at very low specific impulse with dielectric coated grids. Structural integrity is demonstrated with dielectric coated grids for shock (30 G), sinusoidal (9 G), and random (19 G squared/Hz) accelerations. System envelope is 31.6 cm long by 14 cm flange B.C. with a mass of 8.5 kg including 6.2 Kg mercury propellant.

Hyman, J., Jr.↗

SIT-5 system development.

A 5-cm structurally integrated ion thruster (SIT-5) has been developed for attitude control and stationkeeping of synchronous satellites. With two-dimension thrust-vectoring grids, a first generation unit has demonstrated a thrust of 0.56 mlb at a beam voltage of 1200 V, total mass efficiency of 64%, and electrical efficiency of 46.8%. Structural integrity is demonstrated with a dielectric-coated grid for shock (30 G), sinusoidal (9 G), and random (19.9 G rms) accelerations. System envelope is 31.8 cm long by 13.9 cm flange bolt circle, with a mass of 8.5 kg, including 6.2 kg mercury propellant. Characteristics of a second-generation unit indicate significant performance gains.

Hyman, J., Jr.↗

A General Reliability Model for Ni-BaTiO3-Based Multilayer Ceramic Capacitors

The evaluation for potential space project applications of multilayer ceramic capacitors (MLCCs) with Ni electrode and BaTiO3 dielectric material requires an in-depth understanding of the MLCCs reliability. A general reliability model for Ni-BaTiO3 MLCCs is developed and discussed in this paper. The model consists of three parts: a statistical distribution; an acceleration function that describes how a capacitors reliability life responds to external stresses; and an empirical function that defines the contribution of the structural and constructional characteristics of a multilayer capacitor device, such as the number of dielectric layers N, dielectric thickness d, average grain size r, and capacitor chip size A. Application examples are also discussed based on the proposed reliability model for Ni-BaTiO3 MLCCs.

statistical modeling↗

A General Reliability Model for Ni-BaTiO3-Based Multilayer Ceramic Capacitors

The evaluation of multilayer ceramic capacitors (MLCCs) with Ni electrode and BaTiO3 dielectric material for potential space project applications requires an in-depth understanding of their reliability. A general reliability model for Ni-BaTiO3 MLCC is developed and discussed. The model consists of three parts: a statistical distribution; an acceleration function that describes how a capacitor's reliability life responds to the external stresses, and an empirical function that defines contribution of the structural and constructional characteristics of a multilayer capacitor device, such as the number of dielectric layers N, dielectric thickness d, average grain size, and capacitor chip size A. Application examples are also discussed based on the proposed reliability model for Ni-BaTiO3 MLCCs.

statistical modeling↗

Some Aspects of the Failure Mechanisms in BaTiO3-Based Multilayer Ceramic Capacitors

The objective of this presentation is to gain insight into possible failure mechanisms in BaTiO3-based ceramic capacitors that may be associated with the reliability degradation that accompanies a reduction in dielectric thickness, as reported by Intel Corporation in 2010. The volumetric efficiency (microF/cm3) of a multilayer ceramic capacitor (MLCC) has been shown to not increase limitlessly due to the grain size effect on the dielectric constant of ferroelectric ceramic BaTiO3 material. The reliability of an MLCC has been discussed with respect to its structure. The MLCCs with higher numbers of dielectric layers will pose more challenges for the reliability of dielectric material, which is the case for most base-metal-electrode (BME) capacitors. A number of MLCCs manufactured using both precious-metal-electrode (PME) and BME technology, with 25 V rating and various chip sizes and capacitances, were tested at accelerated stress levels. Most of these MLCCs had a failure behavior with two mixed failure modes: the well-known rapid dielectric wearout, and so-called 'early failures." The two failure modes can be distinguished when the testing data were presented and normalized at use-level using a 2-parameter Weibull plot. The early failures had a slope parameter of Beta >1, indicating that the early failures are not infant mortalities. Early failures are triggered due to external electrical overstress and become dominant as dielectric layer thickness decreases, accompanied by a dramatic reduction in reliability. This indicates that early failures are the main cause of the reliability degradation in MLCCs as dielectric layer thickness decreases. All of the early failures are characterized by an avalanche-like breakdown leakage current. The failures have been attributed to the extrinsic minor construction defects introduced during fabrication of the capacitors. A reliability model including dielectric thickness and extrinsic defect feature size is proposed in this presentation. The model can be used to explain the Intel-reported reliability degradation in MLCCs with respect to the reduction of dielectric thickness. It can also be used to estimate the reliability of a MLCC based on its construction and microstructure parameters such as dielectric thickness, average grain size, and number of dielectric layers. Measures for preventing early failures are also discussed in this document.

Liu, David Donhang↗

ISS And Space Environment Interactions Without Operating Plasma Contactor

The International Space Station (ISS) will be the largest, highest power spacecraft placed in orbit. Because of this the design of the electrical power system diverged markedly from previous systems. The solar arrays will operate at 160 V and the power distribution voltage will be 120 V. The structure is grounded to the negative side of the solar arrays so under the right circumstances it is possible to drive the ISS potential very negative. A plasma contactor has been added to the ISS to provide control of the ISS structure potential relative to the ambient plasma. The ISS requirement is that the ISS structure not be greater than 40 V positive or negative of local plasma. What are the ramifications of operating large structures with such high voltage power systems? The application of a plasma contactor on ISS controls the potential between the structure and the local plasma, preventing degrading effects. It is conceivable that there can be situations where the plasma contactor might be non-functional. This might be due to lack of power, the need to turn it off during some of the build-up sequences, the loss of functionality for both plasma contactors before a replacement can be installed, similar circumstances. A study was undertaken to understand how important it is to have the contactor functioning and how long it might be off before unacceptable degradation to ISS could occur. The details of interaction effects on spacecraft have not been addressed until driven by design. This was true for ISS. If the structure is allowed to float highly negative impinging ions can sputter exposed conductors which can degrade the primary surface and also generate contamination due to the sputtered material. Arcing has been known to occur on solar arrays that float negative of the ambient plasma. This can also generate electromagnetic interference and voltage transients. Much of the ISS structure and pressure module surfaces exposed to space is anodized aluminum. The anodization thickness is very thin to provide the required solar absorptance and emittance. For conditions where ISS structure can charge negative a large percentage of the array voltage, the dielectric strength of this layer is low, and dielectric breakdown (arcing) can occur. The energy stored capacitively in the structure can be delivered to the arc. The mechanisms by which this energy is delivered and how much of the energy is available hasn't been fully quantified. Questions have been raised regarding the possibility of whether a sustained arc might result due to current collected by the solar arrays from local plasma. It was postulated that even if dielectric breakdown didn't occur, impacts due to micrometeoroids and space debris could penetrate thin layers of dielectric on ISS and initiate an arc due to the coupling provided by the dense local plasma produced by the impact. This was proven in experiments conducted jointly by MSFC and Auburn University. A target chamber with a simulated ionospheric plasma and a biased, anodized aluminum plate and a 1-microfarad capacitor was used. The plate was then impacted by 75-micron particles accelerated to orbital velocity. Arc discharges were sustained for higher voltages but a threshold appears below which no discharge was initiated. Most items without an exposed power system will float electrically near the local plasma potential. This is true of the Space Shuttle, an Astronaut on EVA, and similar items. The structure of ISS might be at a large negative voltage. Therefore, capacitively stored energy can be transferred during docking, installing external boxes and equipment and Astronaut contact with ISS structure. The circumstances of when this can happen and the resulting effects are evaluated in this study. Also, a crewmember on EVA might be in the vicinity of an arc. All safety aspects of such an encounter including charging, molten particles from the arc site and EMI have been evaluated. This paper will report on the total results of this study focussed on the 4A configuration, scheduled to be complete in November, 2000. Interactions such as arcing, debris induced arcs, sustained arcs, sputtering, contamination from sputtering and arcing, docking interactions and Astronaut safety issues will all be addressed.

Carruth, M. R., Jr.↗

Microbial Vessel for Impedance Spectroscopy and Electrochemistry (Mvise): an Extensible, Interoperable Data Acquisition Platform for Liquid Culture Studies in Space Biology Research

The White House Office of Science and Technology Policy (OSTP) has declared 2023 to be the Year of Open Science following an initiative to democratize scientific knowledge. Simultaneously, new sensor technologies have broadened the experimental space available to bioastronautics research. With these open-science goals and technological advances in mind, we have designed and constructed a data acquisition platform for high-precision, real-time monitoring of liquid culture systems. The vessel rig is fitted with six Atlas Scientific probes (micro pH, electrical conductivity, dissolved oxygen, oxidation-reduction potential, liquid temperature, air CO2) and a custom optical density probe similar to the one on BioSentinel’s BioSensor payload. A custom dielectric spectroscopy probe is also planned. The structure of the vessel is resin 3-D printed on a hobbyist-level machine, reducing the production cost and iteration time by over 60% each while increasing extensibility. Data acquisition and storage is controlled with a standalone C state machine-based program running on a Raspberry Pi 3 Model B. When not running headless, an additional program automatically generates and updates plots for live data visualization. Validation of the rig as a data collection system was performed with a yeast liquid culture experiment. While the vessel rig is currently used for standalone experiments, it can also be used as the base perception unit in a self-driving laboratory (SDL). SDLs are high-throughput data collection systems that employ automation and artificial intelligence to conduct and manage routine experiments. Here, we envision an SDL driven by several vessel rigs in which an automated script compares key results, informing the design of future experiments. A vessel rig SDL would streamline many operations, including 1) strain selection for the Lunar Explorer Instrument for space biology Applications (LEIA) investigation and 2) the study of bioregenerative life support systems (BLSS). Ultimately, the datasets that can now be acquired will provide crucial information for accelerating bioastronautics application development in the era of commercial space.

Stephen Lantin↗