Search NASA⌕ Search

SEARCH · Search NASA

Results for “differential filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High-energy differential-filtering photon spectrometer for ultraintense laser-matter interactions

Large quantities of ultrahigh-energy x-rays are produced by petawatt-class lasers; however, spectroscopy in this range of 0.1-1 MeV is difficult due to the long photon mean free path. A novel geometry step filter to measure the high-energy bremsstrahlung emission tail has been developed for use in high energy density, short-pulse laser-matter interaction experiments. The grid design of the filters allows for the independent determination of a local background, which reduces systematic errors in the reconstructed spectra. This spectrometer was used to measure x-ray spectra for various laser and target conditions at intensities near 1 × 10 18 W/cm 2 where single-exponential bremsstrahlung spectra were fit to the data and show an increasing photon temperature with pulse duration for a fixed laser intensity.

47 OTHER INSTRUMENTATION↗

An Evolve-Filter-Relax Stabilized Reduced Order Stochastic Collocation Method for the Time-Dependent Navier--Stokes Equations

In this paper, we propose a filter-based stabilization of reduced order models (ROMs) for uncertainty quantification (UQ) of the time-dependent Navier--Stokes equations in convection-dominated regimes. Here we propose a novel high-order ROM differential filter and use it in conjunction with an evolve-filter-relax (EFR) algorithm to attenuate the numerical oscillations of standard ROMs. We also examine how stochastic collocation methods can be combined with the EFR algorithm for efficient UQ of fluid flows. We test the new framework in the numerical simulation of a two-dimensional flow past a circular cylinder with a random viscosity that yields a random Reynolds number with mean Re = 100.

97 MATHEMATICS AND COMPUTING↗

Filtration Performance of Simulated 200 West Area Waste Feeds

This report describes the scaled experimental system and approach used to examine dead-end filtration performance of representative 200W waste feeds. The scaled system, which was originally designed and assembled to test Tank Side Cesium Removal (TSCR) system performance with higher-than-expected solid loadings in 2021 (Schonewill et al. 2021), was repurposed to conduct the current experiments at ~1/145 of full scale (based on throughput). Six experimental runs were conducted with five different 200W waste feed simulants: three using a DEF module scaled for TSCR and three using a DEF module scaled for the 200W process modules (based on the current design for the Advanced Modular Pretreatment System). Each experiment was run continuously for multiple days with an operating approach prototypic of the full-scale system. Staff performing the experimental runs monitored performance, obtained data from calibrated process instruments, and collected samples for observation and analysis. The measured data are presented with a focus on assessing DEF performance – specifically, the filters’ differential pressure response to the five waste simulants, frequency and efficacy of backwashing, and baseline recovery between experimental runs; data related to ion exchange column performance are also discussed in cases where the opportunity arose. The experimental campaign demonstrated that the DEFs satisfied their primary function of protecting the ion exchange column from solid intrusion for all the representative simulants used. The filters readily handled solids loadings of =500 ppm (and even greater), especially the modules scaled to the 200W process modules. Adjustments to the processing flow rate and reductions in feed temperature were observed to affect the rate of differential pressure increase on the filters, but neither adversely affected the ability of the DEFs to perform their primary function. Backflushing reliably recovered filter performance in all runs, although it did not prevent irreversible fouling for one simulant. The run that exhibited irreversible fouling established that both the quantity and the nature of the solids being filtered need to be considered when projecting filter performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a deep learning based automated data analysis for step-filter x-ray spectrometers in support of high-repetition rate short-pulse laser-driven acceleration experiments

We present a deep learning based framework for real-time analysis of a differential filter based x-ray spectrometer that is common on short-pulse laser experiments. The analysis framework was trained with a large repository of synthetic data to retrieve key experimental metrics, such as slope temperature. With traditional analysis methods, these quantities would have to be extracted from data using a time-intensive and manual analysis. Furthermore, this framework was developed for a specific diagnostic, but may be applicable to a wide variety of diagnostics common to laser experiments and thus will be especially crucial to the development of high-repetition rate (HRR) diagnostics for HRR laser systems that are coming online.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using time-resolved penumbral imaging to measure low hot spot x-ray emission signals from capsule implosions at the National Ignition Facility

Here, we have developed and fielded a new x-ray pinhole-imaging snout that exploits time-resolved penumbral imaging of low-emission hot spots in capsule implosion experiments at the National Ignition Facility (NIF). We report on results for a series of indirectly driven Be capsule implosions that aim at measuring x-ray Thomson scattering (XRTS) spectra at extreme density conditions near stagnation. In these implosions, x-ray emission at stagnation is reduced by 100 – 1000x compared to standard inertial confinement fusion (ICF) implosions to mitigate undesired continuum background in the XRTS spectra. Our snout design enables not only measurements of peak x-ray emission times, t o , where standard ICF diagnostics would not record any signal, but also allows for inference of hot spots shapes. Measurement of t o is crucial to account for shot-to-shot variations in implosion velocity and therefore to benchmark the achieved plasma conditions between shots and against radiation hydrodynamics simulations. Additionally, we used differential filtering to infer a hot spot temperature of 520 ± 80 eV, which is in good agreement with predictions from radiation hydrodynamic simulations. Here, we find that, despite fluctuations of the x-ray flash intensity of up to 5x, the emission time history is similar from shot to shot, and slightly asymmetric with respect to peak x-ray emission.

47 OTHER INSTRUMENTATION↗

Development of a compact magnetic spectrometer for use at the OMEGA Laser Facility and the National Ignition Facility

Measurement of proton spectra is an important diagnostic for a variety of high energy density physics experiments. Current diagnostics are either not designed to capture the spectrum of low-energy protons or are unsuitable for high debris experiments. To bridge the gap, a new CR-39 based compact magnetic spectrometer (MagSpec) has been developed to measure proton spectra in the 1–20 MeV energy range, with a particular focus on the low-energy (1–6 MeV) spectrum, for use in experiments at the OMEGA Laser Facility and the National Ignition Facility (NIF). In the MagSpec diagnostic, protons of different energies are dispersed as they pass through a magnetic field before impinging on a differentially filtered CR-39 surface, resulting in a spatial distribution of CR-39 tracks that corresponds to the energy spectrum. In this paper, we discuss details of the design and implementation of MagSpec on the NIF and OMEGA.

47 OTHER INSTRUMENTATION↗

Localized mix-induced radiative cooling in a capsule implosion at the National Ignition Facility

In this work, w present direct measurements of electron temperature variations within an inertially confined deuterium-tritium plasma caused by localized mix of higher-Z materials into the central hot spot. The data are derived from newly developed differentially filtered penumbral imaging of the bremsstrahlung continuum emission. Our analysis reveals distinct localized emitting features in the stagnated hot-spot plasma, and we infer spatial variations in the electron temperature: the mixed region is 660±130eV colder than the surrounding hot-spot plasma at 3.26±0.11keV. Our analysis of the energy flow shows that we measure approximately steady-state conditions where the radiative losses in the mix region are balanced by heat conduction from the surrounding hot deuterium-tritium plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal Temperature Measurements of Inertial Fusion Implosions

Accurate measurement of the thermal temperature in inertially confined fusion plasmas is essential for characterizing ignition performance and validating the basic physics understanding of the stagnation conditions. Here we present experimental results from cryogenic deuterium-tritium implosions on the National Ignition Facility using a differential filter spectrometer designed to measure the thermal electron temperature from x-ray continuum emission from the stagnated plasma. Furthermore, electron temperature measurements, used in conjunction with the Doppler-broadened DT neutron spectra, allow one to infer the partition of energy in the hot spot between internal energy and unconverted kinetic energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of Proton Beam-Driven Fusion Reactions Generated by an Ultra-Short Petawatt-Scale Laser Pulse

We present results from a pitcher-catcher experiment utilizing a proton beam generated with nanostructured targets at a petawatt-class, short-pulse laser facility to induce proton-boron fusion reactions in a secondary target. A 45-fs laser pulse with either 400 nm wavelength and 7 J energy, or 800 nm and 14 J, and an intensity of up to 5 × 10 21 W/cm 2 was used to irradiate either thin foil targets or near-solid density, nanostructured targets made of boron nitride (BN) nanotubes. In particular, for 800 nm wavelength irradiation, a BN nanotube target created a proton beam with about five times higher maximum energy and about ten times more protons than a foil target. This proton beam was used to irradiate a thick plate made of boron nitride placed in close proximity to trigger 11 B (p, α) 2α fusion reactions. A suite of diagnostics consisting of Thomson parabola ion spectrometers, postshot nuclear activation measurements, neutron time-of-flight detectors, and differentially filtered solid-state nuclear track detectors were used to measure both the primary proton spectrum and the fusion products. From the primary proton spectrum, we calculated (p, n) and (α,n) reactions in the catcher and compare with our measurements. The nuclear activation results agree quantitatively and neutron signals agree qualitatively with the calculations, giving confidence that primary particle distributions can be obtained from such measurements. These results provide new insights for measuring the ion distributions inside of proton-boron fusion targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prediction for Pressure Differential Across HEPA Filter Media Based on Media Characteristics and Particle Size Distribution

A new method for predicting the pressure drop across High Efficiency Particulate Air (HEPA) filter media is proposed based upon mass deposited onto the filter and known physical characteristics of the filter media. Detailed are the methods used in conjunction with current filter loading models to predict the pressure drop, as well as tests conducted to validate the methods. The benefit of a prediction model for practical use lies in the manufacturing and service life of nuclear grade HEPA filters. HEPA filters for use in nuclear facilities have a prescribed expiration date and a maximum allowable operating pressure drop. Therefore, the ability to predict the pressure drop across a filter and relate it to an expected length of service time can enable a reduction in wasted filters. This will allow for more informed decisions to be made based upon the dictated life cycle of the filters. Also, understanding and predicting how the pressure drop of HEPA filter media behaves as a function of physical characteristics and loaded mass can assist in future design and manufacturing of filter media. Currently, most existing pressure drop models are either computationally based or analytical methods relying on data gathered during tests. Neither are practical for prediction; the computational methods are difficult to implement, and the current analytical methods are more useful as tools for analysis. The current analytical model developed by Bergman et al. is based upon the pressure drop from each media fiber and modeling the deposited particles as newly formed fibers. Using Bergman's model and the media properties, air properties, and known aerosol particle size distribution, a pressure drop curve as a function of loaded mass can be created. This curve implies initial loading in the depth of the filter media with a transition to pure surface loading on the filter face, and a sensitivity to an evolving particle size distribution as mass continues to load onto the filter. To implement the predictive model, knowledge of the mean filter fiber diameter and porosity of the filter media is required. Traditionally, the mean fiber diameter is calculated as an effective diameter from prior media testing, however, in this study a Scanning Electron Microscope (SEM) technique is used to acquire this variable. Validation of the predictive model is provided by flat sheet media tests under a controlled environment with a measured particle size distribution of the challenge aerosol and shows reasonable preliminary agreement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coupled Inductor Design for Interleaved Three-level Active Neutral Point Clamped Inverters Considering EMI Noise Reduction

This paper presents the coupled inductor design for interleaved three-level active neutral point clamped (ANPC) inverter considering electromagnetic interference (EMI) noise reduction. Compared to two-level case, the scenarios involved in the three-level space vector modulation (SVM) are more complicated when analyzing the volt-seconds of the coupled inductor for paralleled three-level inverter. At system level, the purpose of converter interleaving is to reduce EMI noise and ripple current in most applications, and coupled inductor design should consider the needs of EMI noise reduction and EMI filter design. These issues are discussed in this paper. The relationship between circulating current and EMI noise is illustrated. EMI filter corner frequency as a function of interleaving angle is analytically derived, and optimal interleaving angle for maximum common-mode (CM) filter and differential-mode (DM) filter corner frequencies is discussed. Coupled inductor design methodology for interleaved three-level inverters with SVM is then presented. Experiments on two interleaved ANPC inverters are conducted. The results verify the coupled inductor design. With the derived optimal interleaving angle, the CM and DM EMI noise are significantly reduced.

Chen, Ruirui↗

Optimized simple and affordable procedure for differentiation of monocyte-derived dendritic cells from LRF: An accessible and valid alternative biological source

Dendritic cells are one of the most popular immune cells, which plays a remarkable role in both immunotherapy and tolerance induction. Due to unwanted side effects of leukocyte presence in donated blood, the policy of blood service is the pre-storage reduction of leukocytes, which today, filtration is the most common method for this purpose. The filtration method has led to diminished access to Buffy coat as a generally used conventional source of biological cells. We developed a simple, affordable, and reproducible method for dendritic cell differentiation from filter-derived monocytes and, the results of the filter study were compared with differentiated DCs from the conventional buffy coat-derived monocytes. The Monocytes were recovered from leukoreduction filter using an optimized protocol with supplemented PBS buffer. Following the adhesion method, CD14{sup +} Monocyte-enriched population with the purity of 94 % was obtained. After cytokine stimulation over a 6-day period and maturation induction by LPS, differentiated DCs were evaluated for morphology, surface markers (CD86, CD40, CD83 and, HLA-DR), antigen uptake potency and IL-12 secretion. Analysis and comparison of the results represented no significant difference between the two groups. Accordingly, we conclude that leukoreduction filters could be introduced as a reliable and research-grade source of monocyte for DC generation in biological research.

60 APPLIED LIFE SCIENCES↗

Plastic work constrained elastoplastic topology optimization

An elastoplastic topology optimization framework for limiting plastic work generation while maximizing stiffness is presented. The kinematics and constitutive model are based on finite strain linear isotropic hardening plasticity, and the balance laws are solved using a total Lagrangian finite element formulation. Aggregation of the specific plastic work combined with an adaptive normalization scheme efficiently constrains the maximum specific plastic work. The optimization problem is regularized using an augmented partial differential equation filter, and is solved by the method of moving asymptotes where path-dependent sensitivities are derived using the adjoint method. The numerical examples show a clear dependence on the optimized maximum stiffness structures for different levels of constrained specific plastic work. It is also shown that due to the history dependency of the plasticity, the load path significantly influences the structural performance and optimized topology.

42 ENGINEERING↗

Characterization of fast electron divergence and energy spectrum from modeling of angularly resolved bremsstrahlung measurements

Characteristics of fast electrons generated in an intense laser-solid target interaction are studied by modeling angularly resolved bremsstrahlung measurements with a hybrid Particle-In-Cell code, Large Scale Plasmas. The experiment was enacted using the 50 TW Leopard laser at the Nevada Terawatt Facility. A 100 μm thick Cu foil was irradiated by the 15 J, 0.35 ps laser at a peak laser intensity of 2 × 10 19 W/cm 2 . Bremsstrahlung produced by transport and recirculation of the fast electrons in the foil was measured with two differential filter-stack x-ray spectrometers at 22° and 40° from the laser axis. The two-spectrometer signals simultaneously fit by varying single slope temperatures (T hot ) and divergence angles (θ) enable for determining T hot and θ to be 1.1 ± 0.3 MeV and 15° ± 8°, respectively. The T hot inferred from the bremsstrahlung signals agrees with that from an escaped electron measurement, implying that that the bremsstrahlung is predominantly produced by the transport of the high energy fast electrons in the first pass.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Double Shell Inertial Confinement Fusion X-Ray Spectral Analysis

At the National Ignition Facility (NIF), lasers are used to compress a double shell capsule with deuterium and tritium in order to create nuclear fusion processes. The lasers aim at the inside of a gold hohlraum which excite electrons which further release photons in the range of 0~20keV. The photons randomly disperse, ultimately either going towards the fuel capsule or back out the laser entrance holes. The photons that go towards the fuel capsule work towards the compression of the multi-shell capsule whereas the photons that leave the hohlraum have a chance at being picked up by the Lawrence Livermore National Lab’s ‘Dante’ photon detector. ‘Dante’ analyzes photon data by having 18 planar vacuum x-ray diodes (XRD) behind unique filters to differentiate data amongst various photon energies. The goal of the project was to analyze the characteristics of low and high energy photons released by the gold shell.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗