Search NASA⌕ Search

SEARCH · Search NASA

Results for “differential pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Rugged switch responds to minute pressure differentials

Pressure responsive switching device exhibits high sensitivity but is extremely rugged and resistant to large amplitude shock and velocity loading. This snap-action, single pole-double throw switch operates over a wide temperature range.

Friend, L. C.↗

Differential Pressure Helps Seal Ball Valve

Leakage suppressed despite O-ring wear. New design eliminates leakage in vacuum selector valve on Space Shuttle waste-control subsystem. Applied to improve sealing in laboratory and industrial vacuum systems and other plumbing involving switching among lines with pressure differentials of order of 1 atmosphere (0.1 MPa).

Mangialardi, J. K.↗

A program to evaluate a control system based on feedback of aerodynamic pressure differentials

The use of aerodynamic pressure differentials to position a control surface is evaluated. The system is a differential pressure command loop, analogous to a position command loop, where the surface is commanded to move until a desired differential pressure across the surface is achieved. This type of control is more direct and accurate because it is the differential pressure which causes the control forces and moments. A frequency response test was performed in a low speed wind tunnel to measure the performance of the system. Both pressure and position feedback were tested. The pressure feedback performed as well as position feedback implying that the actuator, with a break frequency on the order of 10 Rad/sec, was the limiting component. Theoretical considerations indicate that aerodynamic lags will not appear below frequencies of 50 Rad/sec, or higher.

Levy, D. W.↗

Evacuation-induced pressure differentials in multilayer insulation systems

The pressure differentials induced across three types of multilayer insulation systems during evacuation have been measured and compared with values predicted using an idealized parallel plate geometric model. The systems tested were double-aluminized Mylar with a Tissuglas or silk net spacer and crinkled single-aluminized Mylar. Test samples were circular. The influence of purge gas type, layer density, sample diameter, and temperature was systematically investigated. The experimental approach was to measure the absolute pressure history and corresponding pressure differential induced across the insulation during evacuation. The measured pressure differentials were nondimensionalized and compared with those predicted by the parallel plate model as a function of Knudsen number. It was concluded that the parallel plate model is adequate for making engineering analyses. The influence of all parameters, except layer density, is well represented by the model. Representation of the influence of layer density is less satisfactory, but can be improved by modification of the flat plate model to allow for the more obvious practical nonidealities, such as crinkling, or the presence of a net spacer.

Glassford, A. P. M.↗

Low Differential Pressure Generator

A method and apparatus for evaluating low differential pressure transducers includes a pressure generator in the form of a piston-cylinder assembly having a piston that may be manually positioned precisely within the cylinder to change the volume and thus the pressure at respective sides of the piston. At one side of the piston the cylinder communicates with a first chamber and at the other side of the piston the cylinder communicates with a second chamber, the first and second chambers being formed within a common tank by a partition wall. The chambers each communicate with the transducer to be evaluated and a standard pre-calibrated transducer the transducers being connected fluidly in parallel so that a pressure differential between air in the two chambers resulting from movement of the piston within the cylinder is communicated to both the transducer to be evaluated and the standard transducer, and the outputs of the transducers is observed and recorded.

Stout, Stephen J.↗

A program to evaluate a control system based on feedback of aerodynamic pressure differentials, part 1

The use of pressure differentials in a flight control system was evaluated. The pressure profile around the test surface was determined using two techniques: (1) windtunnel data (actual); and (2) NASA/Langley Single Element Airfoil Computer Program (theoretical). The system designed to evaluate the concept of using pressure differentials is composed of a sensor drive and power amplifiers, actuator, position potentiometer, and a control surface. The characteristics (both desired and actual) of the system and each individual component were analyzed. The desired characteristics of the system as a whole are given. The flight control system developed, the testing procedures and data reduction methods used, and theoretical frequency response analysis are described.

Hrabak, R. R.↗

Spatial Characteristics of the Unsteady Differential Pressures on 16 percent F/A-18 Vertical Tails

Buffeting is an aeroelastic phenomenon which plagues high performance aircraft at high angles of attack. For the F/A-18 at high angles of attack, vortices emanating from wing/fuselage leading edge extensions burst, immersing the vertical tails in their turbulent wake. The resulting buffeting of the vertical tails is a concern from fatigue and inspection points of view. Previous flight and wind-tunnel investigations to determine the buffet loads on the tail did not provide a complete description of the spatial characteristics of the unsteady differential pressures. Consequently, the unsteady differential pressures were considered to be fully correlated in the analyses of buffet and buffeting. The use of fully correlated pressures in estimating the generalized aerodynamic forces for the analysis of buffeting yielded responses that exceeded those measured in flight and in the wind tunnel. To learn more about the spatial characteristics of the unsteady differential pressures, an available 16%, sting-mounted, F-18 wind-tunnel model was modified and tested in the Transonic Dynamics Tunnel (TDT) at the NASA Langley Research Center as part of the ACROBAT (Actively Controlled Response Of Buffet-Affected Tails) program. Surface pressures were measured at high angles of attack on flexible and rigid tails. Cross-correlation and cross-spectral analyses of the pressure time histories indicate that the unsteady differential pressures are not fully correlated. In fact, the unsteady differential pressure resemble a wave that travels along the tail. At constant angle of attack, the pressure correlation varies with flight speed.

Moses, Robert W.↗

Leak Rate Quantification Method for Gas Pressure Seals with Controlled Pressure Differential

An enhancement to the pressure decay leak rate method with mass point analysis solved deficiencies in the standard method. By adding a control system, a constant gas pressure differential across the test article was maintained. As a result, the desired pressure condition was met at the onset of the test, and the mass leak rate and measurement uncertainty were computed in real-time. The data acquisition and control system were programmed to automatically stop when specified criteria were met. Typically, the test was stopped when a specified level of measurement uncertainty was attained. Using silicone O-ring test articles, the new method was compared with the standard method that permitted the downstream pressure to be non-constant atmospheric pressure. The two methods recorded comparable leak rates, but the new method recorded leak rates with significantly lower measurement uncertainty, statistical variance, and test duration. Utilizing this new method in leak rate quantification, projects will reduce cost and schedule, improve test results, and ease interpretation between data sets.

seal↗

Differential pressure gauge has fast response

Differential pressure gage with semiconductor type strain gage elements measures rapidly changing pressure. Output of the strain gage elements is a dc voltage that is directly proportional to the pressure difference being measured.

Weber, H. S.↗

Importance of hydrogen oxidation reaction current in quantifying hydrogen crossover in PEM water electrolyzers at high differential pressure

Understanding hydrogen permeation in proton exchange membrane water electrolyzers (PEMWEs) operating at high differential pressures (>25 bar) is critical towards developing effective gas recombination strategies that enable safe operation and high efficiency. Developing this understanding relies on accurate quantification of hydrogen crossover rates in water electrolyzers operating under such conditions. In this work, we show that PEMWEs operating at high differential pressures exhibit noticeable hydrogen oxidation reaction (HOR) currents. As the HOR consumes part of the permeated hydrogen at the anode, neglecting HOR currents leads to severe underestimation of the hydrogen crossover rate. We implemented a new method combining hydrogen oxidation current with online gas chromatography measurements to accurately quantify hydrogen crossover rates as a function of operating current density in PEMWEs operating at high differential pressures (10–30 bar g ).

25 ENERGY STORAGE↗

Constant-Differential-Pressure Two-Fluid Accumulator

A two-fluid accumulator has been designed, built, and demonstrated to provide an acceptably close approximation to constant differential static pressure between two fluids over the full ranges of (1) accumulator stroke, (2) rates of flow of the fluids, and (3) common static pressure applied to the fluids. Prior differential- pressure two-fluid accumulators are generally not capable of maintaining acceptably close approximations to constant differential pressures. The inadequacies of a typical prior differential-pressure two-fluid accumulator can be summarized as follows: The static differential pressure is governed by the intrinsic spring rate (essentially, the stiffness) of an accumulator tank. The spring rate can be tailored through selection of the tank-wall thickness, selection of the number and/or shape of accumulator convolutions, and/or selection of accumulator material(s). Reliance on the intrinsic spring rate of the tank results in three severe limitations: (1) The spring rate and the expulsion efficiency tend to be inversely proportional to each other: that is to say, as the stiffness (and thus the differential pressure) is increased, the range of motion of the accumulator is reduced. (2) As the applied common static pressure increases, the differential pressure tends to decrease. An additional disadvantage, which may or may not be considered limiting, depending on the specific application, is that an increase in stiffness entails an increase in weight. (3) The additional weight required by a low expulsion efficiency accumulator eliminates the advantage given to such gas storage systems. The high expulsion efficiency provided by this two-fluid accumulator allows for a lightweight, tightly packaged system, which can be used in conjunction with a fuel cell-based system.

Piecuch, Benjamin↗

Determination of flow areas for series-parallel compartment venting to satisfy pressure differential requirements.

A unique method for solving the design problem of determining the areas required to meet an imposed pressure differential limit is presented. The associated analytical technique for determining the transient pressure differentials in a multicompartment series-parallel connected system is also presented. In an effort to verify the results obtained by using the analytical methods presented, a test was conducted using a seven compartment system. It was found in the investigations that a computer program based on the analytical model described can determine the pressure, temperature, pressure differentials, and mass flow rates into and out of each compartment at subsonic or sonic velocities.

Kirby, C. E.↗

Experimental Studies of Flutter of Buckled Rectangular Panels at Mach Numbers from 1.2 to 3.0 Including Effects of Pressure Differential and of Panel Width-Length Ratio

Experimental panel flutter data have been obtained at Mach numbers from 1.2 to 3.0 for buckled rectangular panels and the effect of a pressure differential has been determined. Increasing the pressure differential was effective in eliminating flutter on most of the panels tested. The effects of the variables in the panel flutter parameter ((square root of m(exp 2) -1) * (E/q))(exp 1/3) t/l (where M is the Mach number, q is the dynamic pressure, E is Young's modulus, and t and l are the panel thickness and length, respectively) were investigated for buckled panels clamped on the front and rear edges and a critical value of this parameter of 0.44 is indicated at zero pressure differential when the panel width-length ratio is 0.69. An estimated flutter boundary is presented for buckled panels clamped on four edges, with width-length ratios of 0.21 to 4.0. This boundary shows that the panel width is more significant than the panel length when the ratio of width to length is less than approximately 0.5. Panels clamped on four edges and buckled in two half waves in the direction of flow were found to be particularly susceptible to flutter. The results of limited tests on panels with applied damping, curvature, and lengthwise stiffeners are also presented and discussed.

Sylvester, Maurice A.↗

The use of differential pressure feedback in an automatic flight control system

A feasibility study has been performed to evaluate the performance of a system whereby a control surface is positioned with differential pressure as the feedback variable. Analogous to a position command system, the control surface is commanded to move until a certain differential pressure is achieved at a given point on the surface. Frequency response tests and theoretical considerations indicate that the pressure feedback transfer function is first order, with a break frequency up to 50 rad/sec. There exist applications to the outer loops of flight control systems as well. Stability augmentation, gust alleviation, and stall prevention appear to be possible by feeding back differential pressure across lifting and control surfaces.

Levy, D. W.↗