Search NASA⌕ Search

SEARCH · Search NASA

Results for “differential scanning calorimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A High-Throughput MEMS-Based Differential Scanning Calorimeter for Direct Thermal Characterization of Antibodies

Calorimeters, which can be used for rapid thermal characterization of biomolecules, are getting intense attention in drug development. This paper presents a novel MEMS-based differential scanning calorimeter (DSC) for direct thermal characterization of protein samples. The DSC consisted of a pair of temperature sensors made by vanadium oxide (VOx) film with a temperature coefficient of resistivity of –0.025/K at 300 K, a microfluidic device with high thermal insulation (2.8 K/mW), and a Peltier heater for linear temperature scanning. The DSC exhibited high sensitivity (6.1 µV/µW), low noise (0.4 µW), high scanning rate (45 K/min), and low sample consumption volume (0.63 µL). The MEMS DSC was verified by measuring the temperature-induced denaturation of lysozyme at different pH, and then used to study the thermal stability of a monoclonal antibody (mAb), an antigen-binding fragment (Fab), and a dual variable domain immunoglobulin (DVD-Ig) at pH = 6. The results showed that lysozyme is a stable protein in the pH range of 4.0–8.0. The protein stability study revealed that the transition temperatures of the intact Fab fragment, mAb, and DVD proteins were comparable with conformational stability results obtained using conventional commercial DSC. These studies demonstrated that the MEMS DSC is an effective tool for directly understanding the thermal stability of antibodies in a high-throughput and low-cost manner compared to conventional calorimeters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phoenix Lander's Thermal Evolved Gas Analyzer: Differential Scanning Calorimeter and Mass Spectrometer Database Development

The Mars Scout Phoenix lander will land in the north polar region of Mars in May, 2008. One objective of the Phoenix lander is to search for evidence of past life in the form of molecular organics that may be preserved in the subsurface soil. The Thermal Evolved Gas Analyzer (TEGA) was developed to detect these organics by coupling a simultaneous differential thermal analyzer (SDTA) with a mass spectrometer. Martian soil will be heated to approx.1000 C and potential organic decomposition products such as CO2, CH4 etc. will be examined for with the MS. TEGA s SDTA will also assess the presence of endothermic and exothermic reactions that are characteristic of soil organics and minerals as the soil is heated. The MS in addition to detecting organic decompositon products, will also assess the levels of soil inorganic volatiles such as H2O, SO2, and CO2. Organic detection has a high priority for this mission; however, TEGA has the ability to provide valuable insight into the mineralogical composition of the soil. The overall goal of this work is to develop a TEGA database of minerals that will serve as a reference for the interpretation of Phoenix-TEGA. Previous databases for the ill-fated Mars Polar Lander (MPL)-TEGA instrument only went to 725 C. Furthermore, the MPL-TEGA could only detect CO2 and H2O while the Phoenix-TEGA MS can examine up to 144 atomic mass units. The higher temperature Phoenix-TEGA SDTA coupled with the more capable MS indicates that a higher temperature database is required for TEGA interpretation. The overall goal of this work is to develop a differential scanning calorimeter (DSC) database of minerals along with corresponding MS data of evolved gases that can used to interpret TEGA data during and after mission operations. While SDTA and DSC measurement techniques are slightly different (SDTA does not use a reference pan), the results are fundamentally similar and thus DSC is a useful technique in providing comparative data for the TEGA database. The objectives of this work is to conduct DSC and MS analysis up to 1000 C of select minerals that may be found in the martian soil.

Sutter, B.↗

New eutectic alloys and their heats of transformation

Eutectic compositions and congruently melting intermetallic compounds in binary and multicomponent systems among common elements such as Al, Ca, Cu, Mg, P, Si, and Zn may be useful for high temperature heat storage. In this work, heats of fusion of new multicomponent eutectics and intermetallic phases are reported, some of which are competitive with molten salts in heat storage density at high temperatures. The method used to determine unknown eutectic compositions combined results of differential thermal analysis, metallography, and microprobe analysis. The method allows determination of eutectic compositions in no more than three steps. The heats of fusion of the alloys were measured using commercial calorimeters, a differential thermal analyzer, and a differential scanning calorimeter.

Farkas, D.↗

Investigations Using Laboratory Testbeds to Interpret Flight Instrument Datasets from Mars Robotic Missions

The Astromaterials Research and Exploration Science Directorate at the NASA Johnson Space Center (JSC) has laboratory instrumentation that mimic the capabilities of corresponding flight instruments to enable interpretation of datasets returned from Mars robotic missions. The lab instruments have been and continue to be applied to datasets for the Moessbauer Spectrometer (MB) on the Mars Exploration Rovers (MER), the Thermal & Evolved Gas Analyzer (TEGA) on the Mars Phoenix Scout, the CRISM instrument on the Mars Reconnaissance Orbiter Missions and will be applied to datasets for the Sample Analysis at Mars (SAM), Chemistry and Mineralogy (CheMin) and Chemistry & Camera (ChemCam) instruments onboard the Mars Science Laboratory (MSL). The laboratory instruments can analyze analog samples at costs that are substantially lower than engineering models of flight instruments, but their success to enable interpretation of flight data depends on how closely their capabilities mimic those of the flight instrument. The JSC lab MB instruments are equivalent to the MER instruments except without flight qualified components and no reference channel Co-57 source. Data from analog samples were critical for identification of Mg-Fe carbonate at Gusev crater. Fiber-optic VNIR spectrometers are used to obtain CRISM-like spectral data over the range 350-2500 nm, and data for Fephyllosilicates show irreversible behavior in the electronic transition region upon dessication. The MB and VNIR instruments can be operated within chambers where, for example, the absolute H2O concentration can be measured and controlled. Phoenix's TEGA consisted of a calorimeter coupled to a mass spectrometer (MS). The JSC laboratory testbed instrument consisted of a differential scanning calorimeter (DSC) coupled to a MS configured to operate under total pressure (12 mbar), heating rate (20 C/min), and purge gas composition (N2) analogous to the flight TEGA. TEGA detected CO2 release at both low (400-680 C) and high (725-820 C) temperature and an endothermic reaction in concert with the high temperature release. The high-temperature thermal decomposition is consistent with calcite, dolomite, or ankerite, (3-6 wt.%) or any combination of these phase based upon laboratory testbed experiments. Recent laboratory experiments suggest that the low temperature CO2 release was caused by a reaction between calcium carbonate and hydrated magnesium perchlorate; although, CO2 release by the oxidation of organic materials and Fe-/Mg-rich carbonates cannot be ruled out. MSL landed in Gale crater on August 5, 2012. Although numerous analog samples have been analyzed on the JSC laboratory testbeds, no SAM, CheMin, or ChemCam analyses have been acquired by MSL to date. The JSC SAM laboratory testbed consists of a thermal analyzer coupled with a MS configured to operate under total pressure (30 mbar), heating rate (35 C/min), and purge gas composition (He) analogous to the flight SAM. The CheMin and ChemCam laboratory testbeds were developed and built by inXitu, Inc. and Los Alamos National Laboratory, respectively, to acquire datasets relevant to the MSL CheMin and ChemCam flight instruments.

Ming, D. W.↗

The comet rendezvous asteroid flyby mission

The Comet Rendezvous Asteroid Flyby Mission (CRAF) is described. After gravity assists from Venus and Earth, the spacecraft will fly by the asteroid 46 Hestia en route to a rendezvous with P/Tempel 2 in Nov. 1996, when the comet is near aphelion. The scientific experiments for the CRAF mission are: an imaging system; a visual and infrared mapping spectrometer; an infrared radiometer; a penetrator carrying a gamma-ray spectrometer, a scanning differential calorimeter and evolved gas analyzer, accelerometers, and temperature probes; a neutral gas and thermal ion mass spectrometer; a secondary ion mass spectrometer for analyzing dust, gas, and thermal ions; a scanning electron microscope and particle analyzer; an X-ray fluorescence and gas chromatographic analyzer for collected dust and ice samples; a dust counter and velocity analyzer; a retarding potential ion mass spectrometer; a supra-thermal ion mass spectrometer and electron analyzer; a magnetometer; and a coordinated radio, electron, and plasma wave analyzer.

Neugebauer, M.↗

Phase Transition and Criticality of Methane Confined in Nanopores

For the first time, the phase transition and criticality of methane confined in nanoporous media are measured. The measurement is performed by establishing an experimental setup utilizing a differential scanning calorimeter (DSC) capable of operating under very low temperatures as well as high pressures to detect the capillary phase transition of methane inside nanopores. By performing experiments along isochoric cooling paths, both the capillary condensation and the bulk condensation of methane are detected. Here, the pore critical point (PCP) of nanoconfined methane is also determined and then used to derive the parameters of a previously developed self-consistent equation of state based on the Generalized van der Waals (vdW) partition function. Using this parameter, the equation of state can predict the capillary-condensation curves that agree well with the experimental data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Volatile Products of the Autoxidation of Poly(ethylenimine) in CO 2 Sorbents

Poly(ethyleneimine) (PEI)-based CO 2 sorbents are a promising material class for use in CO 2 capture applications, particularly direct air capture (DAC), due to their high amine content and CO 2 capacities. The sorbent lifetime is a key uncertainty in the deployment of these materials in such applications, as they oxidize under conditions relevant to candidate DAC process cycles. Here, in this study, we utilize thermogravimetric analysis/differential scanning calorimetry/FTIR spectroscopy to characterize the nature, rate, and quantity of volatile species formed from the oxidation of PEI when supported on mesoporous Al 2 O 3 . We show that NH 3 , CO 2 , and H 2 O are primary volatile species formed from PEI oxidation and that their production rate matches the overall oxidation rate as measured via heat flow from a differential scanning calorimeter. We show that the total quantity of NH 3 evolved is consistent with terminal primary amines being cleaved from the polymer chain and that approximately one hydrogen atom per PEI repeat unit reacts to form H 2 O during the reaction. Finally, metadynamics and quantum chemical simulations performed on a simplified system are used to highlight the likely importance of radicals in the elementary reactions that comprise the oxidation reaction set. The findings here represent the first characterization of the volatile products from the oxidation of PEI in CO 2 sorbents and lead to a greater understanding of the mechanisms behind the oxidative degradation of these materials.

36 MATERIALS SCIENCE↗

The Importance of Nonequilibrium to Equilibrium Transition Pathways for the Efficiency and Stability of Organic Solar Cells

Controlled morphology of solution-processed thin films have realized impressive achievements for non-fullerene acceptor (NFA)–based organic solar cells (OSCs). Given the large set of donor–acceptor pairs, employing various processing conditions to realize optimal morphology for high efficiency and stable OSCs is a strenuous task. Therefore, comprehensive correlations between processing conditions and morphology evolution pathways have to be developed for efficient performance and stability of devices. Within the framework of the blend system, crystallization transitions of NFA molecules are tracked utilizing the first heating scan of differential scanning calorimeter (DSC) measurement correlating with respective morphology evolution of blend films. Real-time dynamics measurements and morphology characterizations are combined to provide optimal morphology transition pathways as NFA molecules are shown to be released from the mixed phase to form balanced ordered packing with variant processing conditions. Polymer:NFA films are fabricated using blade coating incorporating solvent additive or thermal annealing as processing conditions as a correlation is formulated between performance and stability of solar cells with morphology transition pathways. In conclusion, this work demonstrates the significance of processing condition-controlled transition pathways for the realization of optimal morphology leading to superior OSC devices.

14 SOLAR ENERGY↗

Predicting EBW detonator failure using DSC data

Exploding bridgewire detonators (EBWs) containing pentaerythritol tetranitrate (PETN) exposed to high temperatures may not function following discharge of the design electrical firing signal from a charged capacitor. Knowing functionality of these arbitrarily facing EBWs is crucial when making safety assessments of detonators in accidental fires. Orientation effects are only significant when the PETN is partially melted. Here, the melting temperature can be measured with a differential scanning calorimeter. Nonmelting EBWs will be fully functional provided the detonator never exceeds 406 K (133 °C) for at least 1 h. Conversely, EBWs will not be functional once the average input pellet temperature exceeds 414 K (141 °C) for a least 1 min which is long enough to cause the PETN input pellet to completely melt. Functionality of the EBWs at temperatures between 406 and 414 K will depend on orientation and can be predicted using a stratification model for downward facing detonators but is more complex for arbitrary orientations. A conservative rule of thumb would be to assume that the EBWs are fully functional unless the PETN input pellet has completely melted.

42 ENGINEERING↗

Ceramic encapsulated metal phase change material for high temperature thermal energy storage

Thermal energy storage (TES) is a broad-based technology for reducing CO₂ emissions and advancing concentrating solar, fossil, and nuclear power through improvements in efficiency and economics. Phase change materials (PCMs) are of interest as TES media because of their ability to store large amounts of heat in relatively small volumes. The volume expansion during a phase change, typically between a solid and liquid, can cause breakage of protective coatings. This paper reports on the fabrication of a ceramic encapsulated metal (CEM) high temperature TES technology using a rotary calcining furnace and a fluidized bed chemical vapor deposition coating technique. Aluminum beads were chosen as the PCM because Al has a high melting point (660 °C), low cost, high heat of fusion, and an ability to form a thin, strong alumina layer capable of supporting the Al melt for subsequent processing. Quite remarkably, this study shows that 1 mm diameter Al can be fluidized up to at least 1500 °C in an appropriate atmosphere while maintaining a spheroid geometry. This allowed for producing a first of a kind CEM whereby Al particles were encapsulated in pyro-carbon (PyC) and high purity, dense chemical vapor deposited SiC. The CEM with a PyC only coating was exposed to thermal cycling to test the performance with a differential scanning calorimeter; the melting point and latent heat were measured to be 648.4 ± 2.8 °C and 293.3 ± 6.2 J/g respectively. It was demonstrated that the CEM design is possible to produce, laying the foundation for manufacturing of high temperature, tunable, TES media.

25 ENERGY STORAGE↗

Silicon alloying enhances fast heating rate combustion of aluminum particles

Alloys and composites of aluminum (Al) have shown promise in regulating and enhancing particle combustion for energy generation applications. Recent work on aluminum-silicon (Al-Si) spherical alloy particles has shown improved combustion at low heating rates through enhanced diffusion accompanying a lower melting temperature. This study extends reactivity analysis to higher heating rates, comparing oxidation of Al-Si with Al. Flame speeds of Al-Si powder mixed with molybdenum trioxide (MoO 3 ) powder (Al-Si+MoO 3 ) exhibited a faster transition to steady propagation relative to Al+MoO 3 . Bomb calorimetry experiments revealed up to 5.8% greater early temperature rise for Al-Si powder. Rapid steady propagation for Al-Si mixture and faster temperature rise for Al-Si particles were attributed to accelerated kinetics evidenced in thermal equilibrium analysis of the mixtures using a differential scanning calorimeter (DSC). Larger DSC exotherms in the early stages of oxidation (i.e., 480–720 °C) correlated with early heat release and promoted steady flame propagation for Al-Si+MoO 3 compared with Al+MoO 3 . Furthermore, in multiple heating rate DSC studies, Al-Si+MoO 3 ignited at a lower heating rate (i.e., 15 ⁰C/min) than Al+MoO 3 (i.e., 20 ⁰C/min). Both mixtures ignited at temperatures less than 625 °C which is above the melting temperature of Al-Si (574 °C) and below Al (659 °C). Thus, alloy particle fuels with enhanced diffusion-controlled kinetics promote steady flame propagation and show promise for energy generation applications. This is especially promising for technologies driven by enhanced condensed phase combustion such as some propellant additives or applications dependent on reliable burn rates such as pyrotechnic time delay formulations and primers.

36 MATERIALS SCIENCE↗

Effect of 60 Co γ-radiation on the tetrafluoroethylene/perfluoro(methyl vinyl ether) copolymer

The chemical and paramagnetic composition of the surface of the tetrafluoroethylene / perfluoro(methyl vinyl ether) copolymer (MFA) was investigated before and after γ-irradiation. The content of fluorine and carbon decreases at radiolysis of MFA, as well as the proportion of oxygen increases as a result of the oxidation reaction of radicals formed during γ-irradiation. The electron paramagnetic resonance (EPR) spectrum of the copolymer irradiated at 77 K contains the radicals ~CF 2 C∙FCF 2 ~ (1) and >CFOC∙F 2 (2). The absence of ~CF 2 C∙F 2 radicals, which can be formed at radiolytic rupture of the C—C bond of the copolymer main chain is associated with the effect of recombination of the resulting radical pair. The EPR spectrum of irradiated MFA at 300 K only recorded radical (1), which transform into peroxide radicals when air oxygen is introduced into the irradiated sample. Thermomechanical curves of native and radiolyzed MFA show three structural states of the amorphous block (glass, transition region, plateau of highly elastic deformation), as well as melting and molecular flow of the copolymer. The radio thermoluminescence curve shows five maxima associated with the emission of light during the recombination of stabilized ions and radicals during heating of the pre-irradiated MFA at 77 K. The temperature of the luminescence peak maximum at 336 K is close to the temperature of the onset of the devitrification of the chains of the amorphous block of MFA on the thermomechanical curve at 341 K. Irradiation leads to an increase in crystallinity of MFA. The heat of fusion of irradiated MFA on the Differential Scanning Calorimeter (DSC) curve is 50 % higher than the fusion heat of native copolymer. During the heating of γ-irradiated MFA, the relative content of COF molecules in the thermal decomposition products increases by an order of magnitude.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Production of polyacrylonitrile/ionic covalent organic framework hybrid nanofibers for effective removal of chromium(VI) from water

Hexavalent Cr(VI) found in industrial wastewater is a proven carcinogen which causes serious health issues in humans around the world. This study presents a novel method to enhance the Cr(VI) oxyanion removal from wastewater by polyacrylonitrile (PAN) nanofibers through incorporation of a guanidinium-based ionic covalent organic framework (BT-DG) in the nanofibers structure. In this work, simple electrospinning technique was employed to produce PAN nanofibers and BT-DG was synthesized through condensation between benzene-1,3,5-tricarbaldehyde and N,N'-diaminoguanidine monohydrochloride. In-situ polymerization of BT-DG onto PAN nanofibers resulted in generation of hybrid PAN-BT-DG nanofibers. This modified PAN-BT-DG was characterized by obtaining its point of zero charge (PZC), differential scanning calorimeter (DSC), scanning electron microscopy (SEM) morphology and surface elements and oxidation states by X-ray photoelectron spectroscopy (XPS). PAN-BT-DG exhibited positive surface charge below pH 4, making it an outstanding adsorbent, for Cr(VI) removal. Cr(VI) adsorption onto PAN-BT-DG followed pseudo second order kinetics and adsorption data fitted well to Freundlich isotherm model. Highest Cr(VI) removal was obtained at 55 °C with a maximum Langmuir adsorption capacity of 173 mg/g at pH 3. Kinetic studies revealed that Cr(VI) adsorption onto PAN-BT-DG is endothermic and thermodynamically feasible. Desorption studies were conducted on PAN-BT-DG using 1 M NaOH as the stripping solvent and PAN-BT-DG exhibited excellent regeneration after five consecutive cycles.

36 MATERIALS SCIENCE↗

Glass transition temperature studies of planetary ball milled glasses: Accessing the rapidly cooled glassy state in Na 4 P 2 S 7-x O x , 0 ≤ x ≤ 7, Oxy-thio phosphate glasses

This paper details the very first in-depth study of the glass transition temperature (T g ) for planetary balled milled (PBM) Na 4 P 2 S 7-x O x (NaPSO), where 0 ≤ x ≤ 7, glasses. For 0 ≤ x ≤ 5, fully amorphous, homogeneous, and chemically reacted compositions can be prepared. For samples with 5 < x ≤ 7, partially amorphous but fully chemically reacted glass-ceramics can be produced. The reproducible, thermally cyclable onset T g and the onset crystallization temperature, T c , were investigated as a function of the composition and of the short-range order (SRO) structures of the glasses. Additionally, we examined the extreme sub-T g exothermic relaxations present due to the high energy milling processing and correspondingly high effective quenching rate. Using a differential scanning calorimeter (DSC) and scanning from well below the onset T g , the glasses are observed to relax exothermally below T g . The integrated relaxation enthalpy, ΔH rel , is ~ 0 for the x = 2 glass, but is significantly exothermic for lower and higher values of x. Once the high fictive state of these glasses has been erased by scanning to above the T g , but below the T c of the glass, the DSC scans of the glasses recover normal behavior for a normally cooled glass without any relaxation exotherm. The T g s of these glasses remain relatively constant for 0 ≤ x ≤ 3, but for glasses with 3 < x ≤ 5, T g increases sharply following the combined effects of the phosphate chain length increasing caused by the formation of bridging oxygens and the increasing concentration of more charge dense non-bridging oxygens (NBOs). For x > 5, both T g and Tc decrease sharply, becoming nearly identical at x = 7 where glass formation essentially ceases. For smaller values of x, T c increases with both chain length and the structural complexity of the composition but decreases sharply for glass-ceramics of x > 5.

36 MATERIALS SCIENCE↗

Thermal runaway mechanism of lithium-ion battery with LiNi 0.8 Mn 0.1 Co 0.1 O 2 cathode materials

Battery safety is critical to the application of lithium-ion batteries, especially for high energy density battery applied in electric vehicles. In this paper, the thermal runaway mechanism of LiNi 0.8 Co 0.1 Mn 0.1 O 2 based lithium-ion battery is illustrated. And the reaction between cathode and flammable electrolyte is proved as the trigger of the thermal runaway accident. In detail, with differential scanning calorimeter tests for battery components, the material combination contributing to thermal runaway was decoupled. Characterization with synchrotron X-ray diffraction and transmission electron microscopy with in-situ heating proved that the vigorous exothermic reaction is initiated by the liberated oxygen species. The pulse of highly active oxygen species reacted quickly with the electrolyte, accompanied with tremendous heat release, which accelerated the phase transformation of charged cathode. Also, the mechanism is verified by a confirmatory experiment when the highly active oxygen species were trapped by anion receptor, the phase transformation of the charged cathode was inhibited. Clarifying the thermal runaway mechanism of LiNi 0.8 Co 0.1 Mn 0.1 based lithium-ion battery may light the way to battery chemistries of both high energy density and high safety.

25 ENERGY STORAGE↗

Experiments on the Capillary Condensation/Evaporation Hysteresis of Pure Fluids and Binary Mixtures in Cylindrical Nanopores

Here, a new experimental method, i.e., isochoric cooling/heating cycle measurement using differential scanning calorimeter (DSC), is applied to investigate the hysteretic phenomenon of pure components and mixtures confined in two different types of cylindrical nanopores (SBA-15 and KIT-6). The capillary condensation/evaporation hysteresis end point (T he ) for a specific system is determined by performing a series of measurements with different densities by increasing initial temperature and pressure. We confirm that for a pure component, T he is lower when confined in smaller nanopores, whereas T he for CH 4 /CO 2 and CH 4 /C 2 H 6 mixtures at the specific composition investigated are higher than that of pure CO 2 and C 2 H 6 , respectively, when confined in the same nanopores. To the best of our knowledge, this is the first time that T he of fluid mixture is experimentally studied, which further demonstrates that binary mixtures behave similarly to pure fluids when confined in nanoporous media. At low temperatures where hysteresis is observed, the shape as well as the duration of the exothermic peak (due to capillary condensation) and endothermic peak (due to capillary evaporation) indicate that capillary condensation, rather than capillary evaporation, takes place at/near a thermodynamic equilibrium. Within the accuracy of the measurements, we find that the total heat of capillary condensation is identical to that of capillary evaporation for all systems examined, regardless of the presence of hysteresis. By comparing the heat per unit volume among different systems, we also find that the heat per unit volume of the phase transition of confined pure fluid is lower than that of bulk, which further demonstrates that the molar density of confined pure liquid is less than that of bulk pure liquid at saturation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tape casting and characterizations of MgO ceramics

Herein we report a high density MgO ceramic substrate produced by the tape casting technology. The tape casting formulation and process produced a uniform tape free of cracking. Y 2 O 3 and SiO 2 were used as the sintering aid for the pressureless sintering of the green tape. X-ray diffraction phase identification indicates that MgO is the main phase, while both Y 2 O 3 and SiO 2 sintering aids react with MgO to form MgY 4 Si 3 O 13 as the second phase. Liquid phase sintering occurs in the temperature range from 1030°C to ~1500°C, which is confirmed by the simultaneous Thermal Gravitation Analysis/ Differential Scanning Calorimeter (TGA/DSC) and the percent linear shrinkage and densification. A 96.5% theoretical density was achieved by presureless sintering at 1650°C for 2 hours, which was further increased to a fully dense structure using hotisostatic- pressing(HIP) at 1650°C and 207 MPa in argon. Scanning electron microscopy (SEM) and energy dispersive(EDS) spectroscopic analysis on the HIP’ed sample show that MgY 4 Si 3 O 13 is located at the MgO grain boundary and the sample has a fully dense structure. The refractive indices and extinction coefficient were measured on the HIP’ed sample along with thermal properties and dielectric properties. Thermal diffusivity and heat capacity were measured to calculate the thermal conductivity.

36 MATERIALS SCIENCE↗

Differential Scanning Calorimetry Calibration and Heat Capacity

The differential scanning calorimeter (DSC) 404 F3 is a machine that heats up to 1500 degrees Celsius, and collects/evaluates thermal properties such as heat capacity, crystallization, glass transition, and more. The first part of the project is based around calibrating the DSC 404 F3 using the given procedures and manuals. This ensures that the DSC 404 F3 is working properly and does not have any issues moving forward. After the calibration is complete, the second part is to start testing. There will be tests conducted on known metals, such as steel and aluminum, in which there is data to compare it to. If the data collected is not accurate compared to its known values, further troubleshooting will need to ensue to ensure that the following process does not give wrong readings. Then, testing will begin for High Entropy Alloys(HEA) and the interesting issue with these is that there is no data to compare these to. The goal of finding the values of the HEA is to find a compatible alloy that we can use in future projects.

Szczech, Sebastian↗