Search NASA⌕ Search

SEARCH · Search NASA

Results for “differential scanning calorimetry (DSC)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Differential Scanning Calorimetry (DSC) for planetary surface exploration

Differential Scanning Calorimetry (DSC) is the quantitative measurement of the enthalpic response of a material to a systematic change in temperature. In practice, the heat flow into or outward from a sample is measured as the sample is heated or cooled at a carefully controlled rate. DSC superficially resembles, but is not the same as differential thermal analysis (DTA), which is the measurement of temperature differences between a sample and reference material as the pair is heated or cooled. The fundamental properties measured by DSC are enthalpies and temperatures of phase transitions and constant-pressure heat capacities. Depending on instrument design and the nature of the sample, high-quality DSC analyses can be obtained on only a few milligrams of solid materials. DSC requires direct contact with the sample and generally degrades, if not destroys, the sample as a consequence of heating. In laboratory applications, it is common to subject the gaseous effluent from the DSC to analysis by a separate evolved-gas analyzer (EGA).

Gooding, James L.↗

Kinetics of phase transformation in glass forming systems

The objectives of this research were to (1) develop computer models for realistic simulations of nucleation and crystal growth in glasses, which would also have the flexibility to accomodate the different variables related to sample characteristics and experimental conditions, and (2) design and perform nucleation and crystallization experiments using calorimetric measurements, such as differential scanning calorimetry (DSC) and differential thermal analysis (DTA) to verify these models. The variables related to sample characteristics mentioned in (1) above include size of the glass particles, nucleating agents, and the relative concentration of the surface and internal nuclei. A change in any of these variables changes the mode of the transformation (crystallization) kinetics. A variation in experimental conditions includes isothermal and nonisothermal DSC/DTA measurements. This research would lead to develop improved, more realistic methods for analysis of the DSC/DTA peak profiles to determine the kinetic parameters for nucleation and crystal growth as well as to assess the relative merits and demerits of the thermoanalytical models presently used to study the phase transformation in glasses.

Ray, Chandra S.↗

Non-Isothermal Calorimetric Studies of the Crystallization of Lithium Disilicate Glass

The influence of preannealing treatments on the polymorphic crystallization of lithium disilicate glasses is examined. As expected, glasses heated at different rates through the temperature range where there is significant nucleation develop widely different numbers of nuclei. This can dramatically influence the stability and transformation characteristics of the annealed glass. Non-isothermal differential scanning calorimetry (DSC) and differential thermal analysis (DTA) measurements are demonstrated to be useful to probe the nucleation behavior. The first systematic investigations of particle size effects on the non-isothermal transformation behavior are presented and discussed. Based on DTA and microscopy experiments, we show that small particles of lithium disilicate glasses crystallize primarily by surface crystallization. The relative importance of surface versus volume crystallization is examined by varying particle size, by introducing nucleating agents and by exposing glasses to atmospheres of different water content. These data are analyzed quantitatively using a numerical model developed in a second paper following in this volume.

Ray, C. S.↗

Proton Conducting Sulfonated Poly(Ionic Liquid) Block Copolymers

Herein, we report the synthesis of proton-conducting sulfonated poly(ionic liquid) block copolymers (S-PILBCPs) containing one block with sulfonic acid (sulfonated styrene, SS) and the other with an IL moiety (vinylbenzylmethylimidazolium bis(trifluoromethylsulfonyl)imide, VBMIm-TFSI) using reversible addition–fragmentation chain-transfer (RAFT) polymerization and post-polymerization modifications (i.e., functionalization, anion exchange reactions, and sulfonation). The S-PILBCPs uniquely conjoin the SS block with mobile protons (H + ) and the PIL block with mobile anions (TFSI – ), where multiple highly desired properties, including high proton conductivity (from the SS block), and high IL-philicity and oxygen solubility (from the PIL block) can exist compartmentally within a microphase separated morphology (evidenced by differential scanning calorimetry (DSC) and small-angle X-ray scattering (SAXS)). High ion conductivity of 79.7 mS/cm at a PIL block composition of 21.6 mol % was observed at 80 °C and 90% relative humidity (RH) (comparable to the benchmark Nafion ionomer). This work successfully demonstrates the design of S-PILBCPs as a new material platform and showcases its promise as an ionomer for proton exchange membrane fuel cells (PEMFCs) as they simultaneously and compartmentally combine proton conductivity and oxygen solubility. Furthermore, these benefits have recently been leveraged to achieve substantial improvement in oxygen reduction reaction (ORR) activity and subsequently fuel cell performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-temperature stability and thermal expansion behavior of equi-atomic refractory multi-principal element alloys based on MoNbTi system for Gen IV reactor applications

The present study investigates the thermal stability and thermal expansion behavior of seven equi-atomic refractory multi-principal element alloys (MPEAs) based on the MoNbTi ternary system composed of low neutron absorption cross section elements. Through an integrated approach utilizing in-situ high-temperature X-ray diffraction (HT-XRD) in conjunction with differential scanning calorimetry (DSC), dilatometry and ageing heat treatment, the thermal stability of the MPEAs was comprehensively analyzed. In-situ HT-XRD experiment confirmed the stability of the room temperature phases up to 1000 °C with no peaks observed corresponding to additional phases in the HT-XRD patterns at 500, 800 and 1100 °C. DSC thermograms showed the absence of peaks up to 1000 °C, while peaks and valleys corresponding to exothermic and endothermic events were observed above 1000 °C. Coefficient of thermal expansion (CTE) derived from second order polynomial fitting of linear thermal expansion data from the dilatometry experiment showed linear increment up to 1000 °C for all the alloys except those containing Zr. The Cr containing alloys exhibited notably higher CTE values, particularly the Al containing alloy exhibited the highest value. Ageing heat treatment at 800 and 1000 °C for 96 h and subsequent microstructural analysis revealed significant precipitation of secondary phases in MoNbTiZr, MoNbTiZrV and MoNbTiCrAl. In conclusion, a substantial increase in hardness was observed in MoNbTiZr and MoNbTiCrAl due to secondary phase precipitation, while the other alloys maintained hardness values comparable to their as-cast and homogenized states.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of Polymer Morphology on Solvent and Catalyst Accessibility during Polyethylene and Polystyrene Autoxidation

Efficient catalytic deconstruction of plastics requires facile solvent and catalyst access to polymer substrates to minimize mass transfer effects. Autoxidation using Co(II) acetate, Mn(II) acetate, and a radical carrier in acetic acid is a promising strategy to deconstruct mixed plastic waste, yet the role of polymer morphology in governing solvent and catalyst accessibility remains poorly understood. Here, in situ simultaneous small- and wide-angle X-ray scattering (SAXS/WAXS), complemented by X-ray fluorescence (XRF) imaging and high-pressure differential scanning calorimetry (DSC), were used to elucidate interactions between acetic acid, a Co/Mn catalyst solution, and semicrystalline polyethylene (PE) and amorphous polystyrene (PS) from room temperature to 160 °C. In PE, acetic acid and catalyst access were confined to amorphous regions and cryomilled particle interfaces at room temperature, while crystalline lamellae remained intact after soaking for up to 34 h. Increasing temperature enabled solvent uptake into PE, followed by solvent-assisted softening above 100 °C, and a modest melting-point depression that removed lamellar transport barriers upon melting. Conversely for PS, acetic acid penetrated the glassy polymer without inducing chain mobility until the glass transition was reached, above which the observed structural changes were consistent with enhanced segmental mobility which enabled bulk penetration. These results suggest that polymer morphology and thermally activated physical transitions arising from diffusion and polymer–solvent interactions can influence whether autoxidation of plastics is transport-limited or kinetically controlled, providing a framework for aligning reaction conditions with reaction outcomes.

09 BIOMASS FUELS↗

Dataset_for_Molecular_Motion_Below_the_Glass_Transition_A_Solid-State_NMR_Study_of_Siloxane_Polymer_Dynamics Study

This dataset contains solid-state 1H and 13C NMR relaxometry data, differential scanning calorimetry (DSC) data, and size exclusion chromatography (SEC/GPC) data supporting the study of sub-glass-transition (sub-Tg) molecular dynamics in a composition- and sequence-controlled series of diphenyl-substituted polysiloxanes (PDMS, 14Ph, 33Ph, 50Ph, 67Ph, and 100Ph; 0–100% diphenylsiloxane content by mole).All solid-state NMR data were acquired on a 200 MHz Bruker Avance III HD spectrometer using a static 7 mm HX probe or a 4 mm HX probe under 4 kHz magic-angle spinning. Raw Bruker TopSpin experiment folders are included for: (1) variable-temperature 1H lineshape measurements used to determine linewidth (FWHM) as a function of temperature across the glass transition; (2) 1H T1 (saturation recovery with solid-echo detection), probing nanosecond-scale dynamics near the 1H Larmor frequency; (3) 1H T1rho (direct spin-lock, 62.5 kHz), probing microsecond-scale segmental dynamics; (4) 13C-detected Lee–Goldburg cross-polarization 1H T1rho (LGCPH T1rho) for 33Ph and 50Ph, resolving aromatic and aliphatic proton environments; and (5) 13C T1 relaxation for 33Ph and 50Ph. Differential scanning calorimetry data (TA Instruments DSC 25, −150 to +120 °C, up to +300 °C for 100Ph, 10 °C/min) are included for all six compositions and support the glass-transition temperatures in Table 1 and Figure 1. Size exclusion chromatography data (Agilent 1200 Series, PL-Gel 300 mixed-C column, THF mobile phase, polystyrene calibration standards) are included for the three synthesized copolymers (33Ph, 50Ph, 67Ph) and support the number-average molecular weights in Table 1. Processed data include per-composition relaxation-time summaries (Excel), curve-fitting and Bloembergen-Purcell-Pound (BPP) model analysis notebooks (Jupyter/Python), and Igor Pro (.pxp) master files used to generate the manuscript's figures.

Bloembergen-Purcell-Pound theory↗

In situ identification of the Martian surface material and its interaction with the Martian atmosphere using DTA/GC

Little is known about the mineralogy of the martian surface material. Several techniques have been suggested as candidates for the in situ identification of the martian surface material. The most promising of these techniques include differential thermal analysis (DTA) coupled with gas chromatography (GC) and differential scanning calorimetry (DSC) coupled with either mass spectrometry (MS) or GC. Our studies showed that differential thermal analysis coupled with gas chromatography (DTA/GC) is a more appropriate analytical technique than DSC/MS or DSC/GC to identify the mineralogy of the martian surface material in situ. DTA/GC can be regarded as an advancement from pyrolytic GC analyses that were successfully flown on previous missions, but have supplied only limited mineralogical information.

Mancinelli, R. L.↗

Crystallization and properties of Sr-Ba aluminosilicate glass-ceramic matrices

Powders of roller quenched (Sr,Ba)O-Al2O3-2SiO2 glasses of various compositions were uniaxially pressed into bars and hot isostatically pressed at 1350 C for 4 hours or cold isostatically pressed and sintered at different temperatures between 800 to 1500 C for 10 or 20 hours. Densities, flexural strengths, and linear thermal expansion were measured for three compositions. The glasss transition and crystallization temperatures were determined by Differential Scanning Calorimetry (DSC). The liquidus and crystallization temperature from the melt were measured using high temperature Differential Thermal Analysis (DTA). Crystalline phases formed on heat treatment of the glasses were identified by powder x ray diffraction. In Sr containing glasses, the monoclinic celsian phase always crystallized at temperatures above 1000 C. At lower temperatures, the hexagonal analog formed. The temperature for orthorhombic to hexagonal structure transformation increased monotonically with SrO content, from 327 C for BaO-Al2O3-2SiO2 to 758 C for SrO-Al2O3-2SiO2. These glass powders can be sintered to almost full densities and monoclinic celsian phase at a relatively low temperature of 1100 C.

Bansal, Narottam P.↗

Crystallization and properties of Sr-Ba aluminosilicate glass-ceramic matrices

Powders of roller quenched (Sr,Ba)O-Al2O3-2SiO2 glasses of various compositions were uniaxially pressed into bars and hot isostatically pressed at 1350 C for 4 hours or cold isostatically pressed and sintered at different temperatures between 800 to 1500 C for 10 or 20 hours. Densities, flexural strengths, and linear thermal expansion were measured for three compositions. The glass transition and crystallization temperatures were determined by Differential Scanning Calorimetry (DSC). The liquidus and crystallization temperature from the melt were measured using high temperature Differential Thermal Analysis (DTA). Crystalline phases formed on heat treatment of the glasses were identified by powder X ray diffraction. In Sr containing glasses, the monoclinic celsian phase always crystallized at temperatures above 1000 C. At lower temperatures, the hexagonal analog formed. The temperature for orthorhombic to hexagonal structural transformation increased monotonically with SrO content, from 327 C for BaO-Al2O3-2SiO2 to 758 C for SrO-Al2O3-2SiO2. These glass powders can be sintered to almost full densities and monoclinic celsian phase at a relatively low temperature of 1100 C.

Bansal, Narottam P.↗

Parameter Identification for Battery Abuse Reaction Kinetics Models Using DSC Analysis [SWR-23-87]

This code estimates the parameters as inputs for NREL’s abuse reaction kinetics model using Differential scanning calorimetry (DSC) experimental data. The parameters for calculating the rates of abuse reactions among battery cell components at elevated temperatures include frequency factor, activation energy, and reaction orders. The least-squared method is employed to fit the reaction model to DSC data. The code is implemented in MATLAB.

Yang, Chuanbo↗

Revealing nanoscale dynamics during an epoxy curing reaction with x-ray photon correlation spectroscopy

In this work the evolution of nanoscale properties is measured during the thermally triggered curing of an industrial epoxy adhesive. We use x-ray photon correlation spectroscopy (XPCS) to track the progression of the curing reaction through the local dynamics of filler particles that reflect the formation of a thermoset network. Out-of-equilibrium dynamics are resolved through identification and analysis of the intensity– intensity autocorrelation functions obtained from XPCS. The characteristic time scale and local velocity of the filler is calculated as functions of time and temperature. We find that the dynamics speed up when approaching the curing temperature (T cure ), and decay rapidly once T cure is reached. We compare the results from XPCS to conventional macroscale characterization by differential scanning calorimetry (DSC). The demonstration and implementation of nanoscale characterization of curing reactions by XPCS proves useful for future development and optimization of epoxy thermoset materials and other industrial adhesive systems.

36 MATERIALS SCIENCE↗

Correlating DSC and X-Ray Measurements Of Crystallinity

Experiment demonstrated approximate linear correlation between degree of crystallinity of multiphase polymer (as calculated from x-ray diffraction measurements) and heat of fusion of polymer (as calculated from differential scanning calorimetry (DSC) measurements). Correlation basis of simple new technique for estimating degree of crystallinity of specimens of polymer from DSC measurements alone.

Yen, Shiao-Ping S.↗