Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffraction contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Polychromatic diffraction contrast tomography

This tutorial review introduces the use of polychromatic radiation for 3D grain mapping using X-ray diffraction contrast tomography. The objective is to produce a 3D map of the grain shapes and orientations within a bulk, millimeter-sized polycrystalline sample. The use of polychromatic radiation enables the standard synchrotron X-ray technique to be applied in a wider range of contexts: 1) Using laboratory X-ray sources allows a much wider application of the diffraction contrast tomography technique. 2) Neutron sources allow large samples, or samples containing high Z elements to be studied. 3) Applied to synchrotron sources, smaller samples may be treated, or faster measurements may be possible. Challenges and particularities in the data acquisition and processing, and the limitations of the different variants, are discussed. - Highlights: • We present a tutorial review of polychromatic diffraction contrast tomography techniques. • The use of polychromatic radiation allows the standard synchrotron DCT technique to be extended to a range of other sources. • The characteristics and limitations of all variants of the techniques are derived, discussed and compared. • Examples using laboratory X-ray and cold neutron radiation are presented. • Suggestions for the future development of these techniques are presented.

36 MATERIALS SCIENCE↗

Diffraction Contrast Tomography: A Novel 3D Polycrystalline Grain Imaging Technique

Diffraction contrast tomography (DCT) is a non-destructive way of imaging microstructures of polycrystalline materials such as metals or crystalline organics. It is a useful technique to map 3D grain structures as well as providing crystallographic information such as crystal orientation, grain shape, and strain. Understanding the internal microstructure of a material is important in understanding the bulk material properties. This report gives a general overview of the similar techniques, DCT data acquisition, and analysis processes. Following the short literature review, potential work and research at Los Alamos National Laboratory (LANL) is discussed.

36 MATERIALS SCIENCE↗

Asymmetric nanoparticle oxidation observed in-situ by the evolution of diffraction contrast

Abstract The use of transmission electron microscopy (TEM) to observe real-time structural and compositional changes has proven to be a valuable tool for understanding the dynamic behavior of nanomaterials. However, identifying the nanoparticles of interest typically require an obvious change in position, size, or structure, as compositional changes may not be noticeable during the experiment. Oxidation or reduction can often result in subtle volume changes only, so elucidating mechanisms in real-time requires atomic-scale resolution or in-situ electron energy loss spectroscopy, which may not be widely accessible. Here, by monitoring the evolution of diffraction contrast, we can observe both structural and compositional changes in iron oxide nanoparticles, specifically the oxidation from a wüstite-magnetite (FeO@Fe 3 O 4 ) core – shell nanoparticle to single crystalline magnetite, Fe 3 O 4 nanoparticle. The in-situ TEM images reveal a distinctive light and dark contrast known as the ‘Ashby-Brown contrast’, which is a result of coherent strain across the core – shell interface. As the nanoparticles fully oxidize to Fe 3 O 4 , the diffraction contrast evolves and then disappears completely, which is then confirmed by modeling and simulation of TEM images. This represents a new, simplified approach to tracking the oxidation or reduction mechanisms of nanoparticles using in-situ TEM experiments.

36 MATERIALS SCIENCE↗

Towards bend-contour-free dislocation imaging via diffraction contrast STEM

Dislocation imaging using transmission electron microscopy (TEM) has been an invaluable tool for characterizing crystallographic defects in metals. Compared to conventional TEM imaging, diffraction contrast imaging scanning transmission electron microscopy (DCI STEM) with appropriate setting can provide better defect contrast with almost negligible bend contour artifacts, enabling more effective analysis of dislocation structures. Here, we investigated why STEM can suppresses bend contour, and how dislocation contrast behaves along with different STEM imaging parameters. Using a body-centered cubic HT-9 ferritic/martensitic alloy as an example, a simple procedure and operational theory are described at the beginning to help set up DCI STEM experiments. Comparing with conventional TEM and the STEM strictly complying with the principle of reciprocity, we found that a pair of STEM convergence and collection semi-angles, α S and β S , a few milliradians in size is essential for bend-contour-free defect imaging. It works in concert such that the convergence STEM probe opens up the reciprocal space, and then a comparable collection region evens out the rocking-curve oscillation and alleviates bend contours from the reciprocal space. This fundamental advantage is unique in DCI STEM. Practical guidelines regarding STEM parameters and specimen orientation and thickness are then provided for DCI STEM dislocation imaging. Lastly, we show that coupling DCI STEM with spectrum images of electron energy loss spectroscopy and of energy-dispersive X-ray Spectroscopy offers a comprehensive characterization of crystallographic defects and chemical information of complex microstructures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron tomography imaging methods with diffraction contrast for materials research

Transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) enable the visualization of three-dimensional (3D) microstructures ranging from atomic to micrometer scales using 3D reconstruction techniques based on computed tomography algorithms. This 3D microscopy method is called electron tomography (ET) and has been utilized in the fields of materials science and engineering for more than two decades. Although atomic resolution is one of the current topics in ET research, the development and deployment of intermediate-resolution (non-atomic-resolution) ET imaging methods have garnered considerable attention from researchers. This research trend is probably not irrelevant due to the fact that the spatial resolution and functionality of 3D imaging methods of scanning electron microscopy (SEM) and X-ray microscopy have come to overlap with those of ET. In other words, there may be multiple ways to carry out 3D visualization using different microscopy methods for nanometer-scale objects in materials. From the above standpoint, this review paper aims to (i) describe the current status and issues of intermediate-resolution ET with regard to enhancing the effectiveness of TEM/STEM imaging and (ii) discuss promising applications of state-of-the-art intermediate-resolution ET for materials research with a particular focus on diffraction contrast ET for crystalline microstructures (superlattice domains and dislocations) including a demonstration of in situ dislocation tomography.

36 MATERIALS SCIENCE↗

Peculiarities of the diffraction contrast in plane-wave X-ray topographs of weakly deformed crystals in the bragg geometry

The regularities of the topographic contrast formation in weakly deformed nonabsorbing crystals in the Bragg geometry for the diffraction of a plane X-ray wave have been investigated by the method of Riemann functions. It is shown that in this case the extinction contrast has an interference character, alternates, and is proportional to the strain gradient rather than to the squared strain (like in the case of strong lattice distortions). The data of the analysis are compared with the results of a model numerical experiment. The possibility of implementing an X-ray-acoustic resonance in the Bragg geometry is shown.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Direct detection system for full-field nanoscale X-ray diffraction-contrast imaging

Recent developments in X-ray science provide methods to probe deeply embedded mesoscale grain structures and spatially resolve them using dark field X-ray microscopy (DFXM). Extending this technique to investigate weak diffraction signals such as magnetic systems, quantum materials and thin films prove challenging due to available detection methods and incident X-ray flux at the sample. We present a direct detection method developed in conjunction with KAImaging which focuses on DFXM studies in the hard X-ray range of 10s of keV and above capable of approaching nanoscale resolution. Additionally, we compare this direct detection scheme with routinely used scintillator-based optical detection and achieve an order of magnitude improvement in exposure times allowing for imaging of weakly diffracting ordered systems.

47 OTHER INSTRUMENTATION↗

Study on the morphology of bulk hydrides by synchrotron X-ray tomography

Highlights: • The first DCT measurements in zirconium using high energy X-rays is shown. • A modified Hough Transform algorithm brings orientation calculation to pixel level. • The hydride plate normals are clustered in the {0002} pole direction. - Abstract: The morphologies of hydrides was studied using synchrotron X-ray at the European Synchrotron Radiation Facility (ESRF) using Diffraction Contrast Tomography (DCT). Diffraction Contrast Tomography is a relatively new technique that uses simultaneous collection of tomographic and diffraction data to reconstruct the 3D microstructural volume; in this case precipitates and matrix grains, while providing crystallographic orientation of neighbouring matrix grains. Previously the method was limited to light metals such as Al or Mg (due to the use of 8–30 keV X-rays). Here we show the first DCT measurements in a high atomic number metal zirconium using high energy X-rays (60 keV).

36 MATERIALS SCIENCE↗

A grating-based single-shot x-ray phase contrast and diffraction method for in vivo imaging

Purpose: The purpose of this study is to develop a single-shot version of the grating-based phase contrast x-ray imaging method and demonstrate its capability of in vivo animal imaging. Here, the authors describe the principle and experimental results. They show the source of artifacts in the phase contrast signal and optimal designs that minimize them. They also discuss its current limitations and ways to overcome them. Methods: A single lead grid was inserted midway between an x-ray tube and an x-ray camera in the planar radiography setting. The grid acted as a transmission grating and cast periodic dark fringes on the camera. The camera had sufficient spatial resolution to resolve the fringes. Refraction and diffraction in the imaged object manifested as position shifts and amplitude attenuation of the fringes, respectively. In order to quantify these changes precisely without imposing a fixed geometric relationship between the camera pixel array and the fringes, a spatial harmonic method in the Fourier domain was developed. The level of the differential phase (refraction) contrast as a function of hardware specifications and device geometry was derived and used to guide the optimal placement of the grid and object. Both ex vivo and in vivo images of rodent extremities were collected to demonstrate the capability of the method. The exposure time using a 50 W tube was 28 s. Results: Differential phase contrast images of glass beads acquired at various grid and object positions confirmed theoretical predictions of how phase contrast and extraneous artifacts vary with the device geometry. In anesthetized rats, a single exposure yielded artifact-free images of absorption, differential phase contrast, and diffraction. Differential phase contrast was strongest at bone-soft tissue interfaces, while diffraction was strongest in bone. Conclusions: The spatial harmonic method allowed us to obtain absorption, differential phase contrast, and diffraction images, all from a single raw image and is feasible in live animals. Because the sensitivity of the method scales with the density of the gratings, custom microfabricated gratings should be superior to off-the-shelf lead grids.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging antiferromagnetic antiphase domain boundaries using magnetic Bragg diffraction phase contrast

Manipulating magnetic domains is essential for many technological applications. Recent breakthroughs in Antiferromagnetic Spintronics brought up novel concepts for electronic device development. Imaging antiferromagnetic domains is of key importance to this field. Unfortunately, some of the basic domain types, such as antiphase domains, cannot be imaged by conventional techniques. Herein, we present a new domain projection imaging technique based on the localization of domain boundaries by resonant magnetic diffraction of coherent X rays. Contrast arises from reduction of the scattered intensity at the domain boundaries due to destructive interference effects. We demonstrate this approach by imaging antiphase domains in a collinear antiferromagnet Fe 2 Mo 3 O 8 , and observe evidence of domain wall interaction with a structural defect. Here, this technique does not involve any numerical algorithms. It is fast, sensitive, produces large-scale images in a single-exposure measurement, and is applicable to a variety of magnetic domain types.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Angular pattern of electron diffraction by reflection in the plasmon channel of energy losses

We have constructed a theory for the excitation of plasmons by a fast charged particle that undergoes diffraction in a single crystal and then is scattered elastically and incoherently through a large angle. The theory allows the 30-year-old experimental results that have seemed strange to be explained. An increase in the diffraction contrast in the channel of inelastic electron scattering related to the excitation of a bulk plasmon compared to the diffraction contrast of elastically and incoherently reflected electrons was observed in these experiments. Based on this theory, we show that the excitation of a surface plasmon affects only slightly the angular diffraction pattern, leaving it almost the same as that for elastically reflected electrons. These peculiarities of elastic and inelastic diffraction can be used to identify the type of energy plasma loss.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantitative compositional analysis and strain study of InAs quantum wires with InGaAlAs barrier layers

Quantitative compositional analysis of InAs quantum wires deposited between In{sub 0.53}Ga{sub 0.37}Al{sub 0.1}As barrier layers grown on InP substrates was performed by electron energy loss spectrometry and energy dispersive x-ray spectrometry. An indium-rich region in the center of the wire, with decreasing indium concentration toward the interface with the barrier layers, was observed from indium concentration maps for individual quantum wires. 'Stripelike' contrast modulation was observed in diffraction contrast transmission electron microscope images of the In{sub 0.53}Ga{sub 0.37}Al{sub 0.1}As barrier layer immediately above the quantum wires. The contrast originated from indium compositional modulations in the upper barrier layer as confirmed by electron energy loss spectrometry and the modulation is attributed to the presence of an inhomogeneous elastic strain field generated by the buried quantum wires. These results suggest that quantitative analysis of the composition and strain distributions at very high spatial resolution provides insights necessary to further model the physical properties and to understand the growth of these nanostructures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Experimental investigation of the dependence of void nucleation and growth on initial microstructure in high-purity titanium under tension

An experimental investigation of failure mechanisms in relation to the initial microstructure in high-purity titanium samples is presented. The initial microstructure of the specimens was measured in 3D using diffraction-contrast tomography (DCT). Ex-situ X-ray computed tomography (XCT) was used to visualize voids in specimens at various levels of deformation attained by interrupted tensile testing. Electron backscatter diffraction (EBSD) mapping was used to characterize the deformed microstructures per specimen. The investigation showed that the location of failures was unrelated to the formation of the first voids, but rather the nucleation and growth of cracks were from heavily deformed surface regions. The areas surrounding the failure-causing cracks had the highest propensity for void development of any area in the specimen. This facilitated crack propagation through the specimen via “linking up”. The failure of the specimens by microvoid coalescence was bolstered by “dimpled” fracture surfaces. Paint composed of gallium embedded in rubber was used to track the displacement of points along the loading direction of the specimens, to relate the location of failure to the material's initial microstructure. However, the correlation proved difficult, due to complex microstructural evolution involving voids, grain fragmentations, and profuse twinning. Nevertheless, it was shown that necking occurred near the largest grain in the gauge section of the specimens. This is likely caused by the decrease in strength of larger grains, causing strain to concentrate in their vicinity. Here, a comprehensive picture of the failure processes in high-purity titanium under axial loading is presented and discussed in the paper.

36 MATERIALS SCIENCE↗

Semi-Automated, Object-Based Tomography of Dislocation Structures

The characterization of the three-dimensional arrangement of dislocations is important for many analyses in materials science. Dislocation tomography in transmission electron microscopy is conventionally accomplished through intensity-based reconstruction algorithms. Although such methods work successfully, a disadvantage is that they require many images to be collected over a large tilt range. Here, we present an alternative, semi-automated object-based approach that reduces the data collection requirements by drawing on the prior knowledge that dislocations are line objects. Our approach consists of three steps: (1) initial extraction of dislocation line objects from the individual frames, (2) alignment and matching of these objects across the frames in the tilt series, and (3) tomographic reconstruction to determine the full three-dimensional configuration of the dislocations. Drawing on innovations in graph theory, we employ a node-line segment representation for the dislocation lines and a novel arc-length mapping scheme to relate the dislocations to each other across the images in the tilt series. We demonstrate the method for a dataset collected from a dislocation network imaged by diffraction-contrast scanning transmission electron microscopy. Based on these results and a detailed uncertainty analysis for the algorithm, we discuss opportunities for optimizing data collection and further automating the method.

47 OTHER INSTRUMENTATION↗

3D analysis of abnormal grain growth in calcia doped alumina in the presence of large pores

Abnormal grain growth has been previously found to increase with the inclusion of large pores (∼60 µm in diameter) in 80 ppm calcium doped alumina. However, the two-dimensional analysis could not accurately describe the proximity of the abnormal grains and pores to establish a correlation. This study uses laboratory-based diffraction contrast tomography and x-ray computed tomography to spatially map the pores and abnormal grains in 3D. A preference towards the formation of abnormal grains near large pores is found when compared to all potential sites. This finding supports that the pores may be a nucleation site for complexion transitions that promote abnormal grain growth. The growth of the abnormal grains in a subsequent heat treatment at 1600°C for 16 hrs was also studied. The elongation along the principal axes is similar for both small and large grains, again supporting that abnormal grain growth was facilitated by a complexion transition.

Abnormal grain growth↗