Acquisition of a High Resolution Field Emission Scanning Electron Microscope for the Analysis of Returned Samples

This grant furnished funds to purchase a state-of-the-art scanning electron microscope (SEM) to support our analytical facilities for extraterrestrial samples. After evaluating several instruments, we purchased a JEOL 6500F thermal field emission SEM with the following analytical accessories: EDAX energy-dispersive x-ray analysis system with fully automated control of instrument and sample stage; EDAX LEXS wavelength-dispersive x-ray spectrometer for high sensitivity light-element analysis; EDAX/TSL electron backscatter diffraction (EBSD) system with software for phase identification and crystal orientation mapping; Robinson backscatter electron detector; and an in situ micro-manipulator (Kleindiek). The total price was $550,000 (with $150,000 of the purchase supported by Carnegie institution matching funds). The microscope was delivered in October 2002, and most of the analytical accessories were installed by January 2003. With the exception of the wavelength spectrometer (which has been undergoing design changes) everything is working well and the SEM is in routine use in our laboratory.

Nittler, Larry R.↗

Stray Light Analysis

Based on a Small Business Innovation Research contract from the Jet Propulsion Laboratory, TracePro is state-of-the-art interactive software created by Lambda Research Corporation to detect stray light in optical systems. An image can be ruined by incidental light in an optical system. To maintain image excellence from an optical system, stray light must be detected and eliminated. TracePro accounts for absorption, specular reflection and refraction, scattering and aperture diffraction of light. Output from the software consists of spatial irradiance plots and angular radiance plots. Results can be viewed as contour maps or as ray histories in tabular form. TracePro is adept at modeling solids such as lenses, baffles, light pipes, integrating spheres, non-imaging concentrators, and complete illumination systems. The firm's customer base includes Lockheed Martin, Samsung Electronics and other manufacturing, optical, aerospace, and educational companies worldwide.

Source record↗

First Results from a Microfocus X-Ray System for Macromolecular Crystallography

The design and performance of a 40 Watt laboratory crystallography system optimized for the structure determination of small protein crystals are described. This system combines a microfocus x-ray generator (40 microns FWHM spot size at a power level of 40 Watts) and a short focal length (F = 2.6 mm) polycapillary collimating optic, and produces a small diameter quasi-parallel x-ray beam. Measurements of x-ray flux, divergence and spectral purity of the resulting x-ray beam are presented. The x-ray flux in a 250 microns diameter aperture produced by the microfocus system is 14.7 times higher .than that from a 3.15 kW rotating anode generator equipped with graphite monochromator. Crystallography data taken with the microfocus system are presented, and indicate that the divergence and spectral purity of the x-ray are sufficient to refine the diffraction data using a standard crystallographic software. Significant additional improvements in flux and beam divergence are possible, and plans for achieving these coals are discussed.

Gubarev, Mikhail↗

Laboratory Investigation of the Effect of Venusian Weathering on Mineral Spectra

Introduction: The recent selection of two missions to Venus has renewed the importance of deter-mining weathering reactions between minerals and the Venusian atmosphere, and the spectral signatures of minerals before, during, and after these reactions. The rate at which weathering reactions progress also constrain show long unstable minerals will be present on the surface (e.g., [1]), and enables the use of mineralogy as a constraint on surface age(e.g., [2-3]).In order to gain an understanding of how mineral compositions and spectra change with weathering, we have begun conducting experiments in a 1 atm experimental setup at Wesleyan University. This setup exposes minerals to the temperature and most abundant gases of the Venus atmosphere (CO2, SO2, N2).We conducted initial experiments using biotite, calcite, and montmorillonite in order to test our methodology with minerals that may be relevant to recording the history of water on Venus. Methods: Experiments were conducted in Thermo Fisher Scientific Lindberg/Blue M Mini-Mite horizontal tube furnaces at Wesleyan University. Experiments used natural mineral chips and powders, and were conducted at 1 atmosphere and 460 °C under pre-mixed gases provided by Air Gas(Table 1). The furnaces are set up in a flow through configuration so that solid samples are exposed to a fixed gas composition, and quartz glass process tubes were used in all experiments (1/4” diameter for experiment V4, ½” diameter for all others). These conditions were maintained for the du-rations listed in Table 1, at which point the furnace was turned off with gas flowing until the sample was cool enough to extract under N2and be placed in a desiccator for storage. Run products were carbon coated and examined using a Hitachi SU5000 Field Emission Gun Scanning Electron Microscope (SEM) equipped with an EDAX Octane Pro EDS detector located at Wesley-an University. Visible-Near Infrared Spectroscopy (VNIR) analysis was performed on powdered samples under a nitrogen atmosphere using an ASD Fieldspec Proover the 350-2500 nm range. Powdered mineral samples were milled to a particle size of < 45μm and were spiked with an internal standard (Al2O3, corundum) to obtain quantitative mineralogy. Samples were analyzed using a Panalytical X’Pert pro X-ray Diffractometer (XRD), with an X’Celerator high speed detector and Co Kα radiation, with data collected at a step size of 0.02 ̊/minute step counting rate from 2 to 80 degrees 2θ at 45 mA/40kV in the X-ray Diffraction Laboratory located at NASA Johnson Space Center. Materials Data Inc (MDI) software suite, JadeTMv9 was used for Rietveld refinement to determine phase abundances and mineral identification by comparing XRD patterns to International Center for Diffraction Data (ICDD) database patterns. Table 1: Experimental matrix. Experiment Name Duration (Days)Gas Com-position (trace gas)MineralsV487SO2/N2(1.4%)Montmorillonite, biotiteV519SO2/N2(1.4%)CalciteV619CO2/SO2/N2(1.4% SO2, 2.1% N2)Montmorillonite, biotiteV828SO2/N2(1.4%)Biotite, calcite Results: Calcite. In both experiments, calcite was exposed to the SO2/N2gas mixture, and in both experimental run products, XRD analysis detected anhydrite, which is consistent with EDS measurements conducted in the SEM. The XRD analyses show greater amounts of anhydrite present after 28 days than 19, suggesting the calcite reaction progressed further given longer duration. Grain surface morphology as seen in the SEM also shows secondary mineral growth (Fig. 1). VNIR spectra show no change, as expected since anhydrite lacks spectral features in this wavelength range. Montmorillonite. Montmorillonite was exposed to two different gas mixtures, the SO2/N2mix and CO2/SO2/N2mix over different durations (87 and 19 days, respectively). VNIR analyses of both run products show a reduction in the 1441and1910 nm water features as well as a shift of the 1411 and 2011 nm features to shorter wavelengths that may indicate re-structuring in the crystal lattice and the production of amorphous phases [4]. XRD results are consistent with this, showing a shift of the 001 peak from 15Åto 10Åin both run products. The amount of X-ray amorphous material in the montmorillonite run products was greater than that present in the unreacted clay, being the greatest in the 87 day V4 experiment. No other secondary phases were detected in the run products, however sulfur was present in EDS analyses of powder samples.

A R Santos↗

The High Mosaicity Illusion: Revealing the True Physical Characteristics of Macromolecular Crystals

An experimental system and software have been developed for simultaneously measuring the diffraction resolution and mosaic spread of macromolecular crystals. Hundreds of reflection profiles over a wide resolution range were rapidly measured by using a charge coupled device (CCD) area detector in combination with superfine phi slicing data collection. The contributions of the X-ray beam to the reflection widths were minimized by using a highly-parallel, highly-monochromatic synchrotron source. These contributions and Lorentz effects were evaluated and deconvoluted from the recorded data. Data collection and processing is described. From one degree of superfine phi slice data collected on a crystal of manganese superoxide dismutase the mosaicity of 261 reflections were measured. The average mosaicity was 0.0101 degrees (0.0035) at the full-width-at-half-maximum (FWHM) and ranged from 0.0011 degrees to 0.0188 degrees. Each reflection profile was individually fit with two gaussian profiles with the first gaussian contributing 55% and the second contributing 35% of the reflection. On average, the mosaicity of the first gaussian was 0.0054 degrees (0.0015) and the second was 0.0061 degrees (0.0023). The mosaicity of the crystal was anisotropic with fh, f k, and fl values of 0.0068 degrees, 0.0140 degrees and 0.0046 degrees, respectively at the FWHM. The anisotropic mosaicity analysis indicates that the crystal is the most perfect in the I direction which corresponds to the favored growth direction of the crystal.

Bellamy, Henry↗

A New Optical Aerosol Spectrometer

An optical particle spectrometer capable of measuring aerosol particle size distributions from 0.02 to 100 micrometers has been developed. This instrument combines several optical methods in one, in-situ configuration; it can provide continuous data collection to encompass the wide dynamic size ranges and concentrations found in studies of modeled planetary atmospheres as well as terrestrial air quality research. Currently, the system is incorporated into an eight liter capacity spherical pressure vessel that is appropriate both for flowthrough and for in-situ particle generation. The optical sizing methods include polarization ratio, The scattering, and forward scattering detectors, with illumination from a fiber-coupled, Argon-ion laser. As particle sizes increase above 0.1 micrometer, a customized electronics and software system automatically shifts from polarization to diffraction-based measurements as the angular scattering detectors attain acceptable signal-to-noise ratios. The number concentration detection limits are estimated to be in the part-per-trillion (ppT by volume) range, or roughly 1000 submicron particles per cubic centimeter. Results from static experiments using HFC134A (approved light scattering gas standard), flow-through experiments using sodium chloride (NaCl) and carbon particles, and dynamic 'Tholin' (photochemical produced particles from ultraviolet (UV)-irradiated acetylene and nitrogen) experiments have been obtained. The optical spectrometer data obtained with particles have compared well with particle sizes determined by electron microscopy. The 'Tholin' tests provided real-time size and concentration data as the particles grew from about 30 nanometers to about 0.8 micrometers, with concentrations ranging from ppT to ppB, by volume. Tests are still underway, to better define sizing accuracy and concentration limits, these results will be reported.

Fonda, Mark↗

Optimization of Microelectronic Devices for Sensor Applications

The NASA/JPL goal to reduce payload in future space missions while increasing mission capability demands miniaturization of active and passive sensors, analytical instruments and communication systems among others. Currently, typical system requirements include the detection of particular spectral lines, associated data processing, and communication of the acquired data to other systems. Advances in lithography and deposition methods result in more advanced devices for space application, while the sub-micron resolution currently available opens a vast design space. Though an experimental exploration of this widening design space-searching for optimized performance by repeated fabrication efforts-is unfeasible, it does motivate the development of reliable software design tools. These tools necessitate models based on fundamental physics and mathematics of the device to accurately model effects such as diffraction and scattering in opto-electronic devices, or bandstructure and scattering in heterostructure devices. The software tools must have convenient turn-around times and interfaces that allow effective usage. The first issue is addressed by the application of high-performance computers and the second by the development of graphical user interfaces driven by properly developed data structures. These tools can then be integrated into an optimization environment, and with the available memory capacity and computational speed of high performance parallel platforms, simulation of optimized components can proceed. In this paper, specific applications of the electromagnetic modeling of infrared filtering, as well as heterostructure device design will be presented using genetic algorithm global optimization methods.

Cwik, Tom↗

Nanotechnology Infrared Optics for Astronomy Missions

We have used the "MicroStripes" code (Flomerics, Inc.) to perform full-, near- and far-field diffraction modeling of metal mesh performance on substrates. Our Miles Code software, which approximates the full calculation in a quick, gui-based window, is useful as an iterative device by adjusting the input parameters (index of refraction, thickness, etc.) to provide agreement with the full calculation. However, despite the somewhat extravagant claims by the MicroStripes manufacturer, this code is also not perfect because numerous free parameters must be set. Key among these, as identified in our earlier papers and proposal documents, is the high frequency (i.e., far IR) character of the real and imaginary parts of the index of refraction of the metal mesh, the high frequency character of the real and imaginary parts of the index of refraction of the substrate, and the character of the interface between the mesh and the substrate material, and in particular the suppression (or possible enhancement) of surface effects at the interface.

Frogel, Jay↗

Orbital operations with the Shuttle Infrared Telescope Facility /SIRTF/

The Shuttle Infrared Telescope Facility (SIRTF) is a cryogenically-cooled, 1-m-class telescope that will be operated from the Space Shuttle as an observatory for infrared astronomy. This paper discusses the scientific constraints on and the requirements for pointing and controlling SIRTF as well as several aspects of SIRTF orbital operations. The basic pointing requirement is for an rms stability of 0.25 arcsec, which is necessary to realize the full angular resolution of the 5-micron diffraction-limited SIRTF. Achieving this stability requires the use of hardware and software integral to SIRTF working interactively with the gyrostabilized Shuttle pointing-mount. The higher sensitivity of SIRTF, together with orbital and time constraints, puts a premium on rapid target acquisition and on efficient operational and observational procedures. Several possible acquisition modes are discussed, and the importance of source acquisition by maximizing the output of an infrared detector is emphasized.

Werner, M. W.↗

Optical Design of the Developmental Cryogenic Active Telescope Testbed (DCATT)

In the summer of 1996, three Study teams developed conceptual designs and mission architectures for the Next Generation Space Telescope (NGST). Each group highlighted areas of technology development that need to be further advanced to meet the goals of the NGST mission. The most important areas for future study included: deployable structures, lightweight optics, cryogenic optics and mechanisms, passive cooling, and on-orbit closed loop wavefront sensing and control. NASA and industry are currently planning to develop a series of ground testbeds and validation flights to demonstrate many of these technologies. The Deployed Cryogenic Active Telescope Testbed (DCATT) is a system level testbed to be developed at Goddard Space Flight Center in three phases over an extended period of time. This testbed will combine an actively controlled telescope with the hardware and software elements of a closed loop wavefront sensing and control system to achieve diffraction limited imaging at 2 microns. We will present an overview of the system level requirements, a discussion of the optical design, and results of performance analyses for the Phase 1 ambient concept for DCATT,

Davila, Pam↗

Preliminary software development for optical mirror figure control

The maintenance of accurate primary mirror figure in the face of environmental disturbances is the key to the achievement of diffraction-limited performance in a large space telescope. In order to develop the concepts of optical mirror figure control, an experimental program was initiated. A major component in this experiment will be an XDS Sigma 5.7 digital computer which will realize the control algorithm. A software package is described which realizes linear optimal, simplified linear, and iterative optimal control algorithms. The software, in addition, provides for interactive communication between the operator and the computer, and interaction between the computer and the experimental hardware elements. A brief description of a small hybrid computer system is also presented.

Mackinnon, D.↗

Control of unsteady separated flow associated with the dynamic stall of airfoils

A unique active flow-control device is proposed for the control of unsteady separated flow associated with the dynamic stall of airfoils. The device is an adaptive-geometry leading-edge which will allow controlled, dynamic modification of the leading-edge profile of an airfoil while the airfoil is executing an angle-of-attack pitch-up maneuver. A carbon-fiber composite skin has been bench tested, and a wind tunnel model is under construction. A baseline parameter study of compressible dynamic stall was performed for flow over an NACA 0012 airfoil. Parameters included Mach number, pitch rate, pitch history, and boundary layer tripping. Dynamic stall data were recorded via point-diffraction interferometry and the interferograms were analyzed with in-house developed image processing software. A new high-speed phase-locked photographic image recording system was developed for real-time documentation of dynamic stall.

Wilder, M. C.↗

NASA Tech Briefs, November 2003

Topics covered include: Computer Program Recognizes Patterns in Time-Series Data; Program for User-Friendly Management of Input and Output Data Sets; Noncoherent Tracking of a Source of a Data-Modulated Signal; Software for Acquiring Image Data for PIV; Detecting Edges in Images by Use of Fuzzy Reasoning; A Timer for Synchronous Digital Systems; Prototype Parts of a Digital Beam-Forming Wide-Band Receiver; High-Voltage Droplet Dispenser; Network Extender for MIL-STD-1553 Bus; MMIC HEMT Power Amplifier for 140 to 170 GHz; Piezoelectric Diffraction-Based Optical Switches; Numerical Modeling of Nanoelectronic Devices; Organizing Diverse, Distributed Project Information; Eigensolver for a Sparse, Large Hermitian Matrix; Modified Polar-Format Software for Processing SAR Data; e-Stars Template Builder; Software for Acoustic Rendering; Functionally Graded Nanophase Beryllium/Carbon Composites; Thin Thermal-Insulation Blankets for Very High Temperatures; Prolonging Microgravity on Parabolic Airplane Flights; Device for Locking a Control Knob; Cable-Dispensing Cart; Foam Sensor Structures Would be Self-Deployable and Survive Hard Landings; Real-Gas Effects on Binary Mixing Layers; Earth-Space Link Attenuation Estimation via Ground Radar Kdp; Wedge Heat-Flux Indicators for Flash Thermography; Measuring Diffusion of Liquids by Common-Path Interferometry; Zero-Shear, Low-Disturbance Optical Delay Line; Whispering-Gallery Mode-Locked Lasers; Spatial Light Modulators as Optical Crossbar Switches; Update on EMD and Hilbert-Spectra Analysis of Time Series; Quad-Tree Visual-Calculus Analysis of Satellite Coverage; Dyakonov-Perel Effect on Spin Dephasing in n-Type GaAs; Update on Area Production in Mixing of Supercritical Fluids; and Quasi-Sun-Pointing of Spacecraft Using Radiation Pressure.

Source record↗

CODEX Optical Design and Alignment

The COronal Diagnostic EXperiment (CODEX) is a Heliophysics mission to measure the density, temperature, and velocity of the electrons in the solar corona with the primary goal of improving our understanding of the physical conditions of the solar wind in the acceleration region. The temperature and velocity measurement requires much higher signal-to-noise ratio than the density measurements. In solar coronagraphs, the diffraction of the solar disk light due to the occulting element is the dominant source of noise. Therefore, to further suppress the diffracted sun light with respect to the existing coronagraphs is a critical element of the CODEX design. To minimize the stray light due to diffraction, the selected optical design is a two-stage standard coronagraph with an external occulter, an internal occulter, and a Lyot stop. What is unique for this design is that a focal mask was inserted at the telescope focal plane. It works together with the field lens suppressing the stray light down by ~ another order of magnitude as compared to a traditional three-stage approach. During the optical design, a Fourier Transform based beam propagation software, i.e., GLAD, was used to model the beam path through the full coronagraph, from the external occulter to the detector array. All diffraction sensitive elements: external occulter, internal occulter, focal mask, and Lyot stop were carefully modeled and optimized. As a result, the requirement of achieving a stray light level which is one order of magnitude lower than F-corona was satisfied. On the other hand, to achieve the final suppression, a precision optical alignment is another must. This paper also presents our creative alignment procedure: using the combination of metrology, precision alignment equipment, and real time diffraction ring monitoring to minimize the diffraction. The final test results show that the suppression ratio (B/B 0 ) reaches 10 -11 level, which is equivalent to one order of magnitude lower than F-corona.

CODEX optical design and alignment↗

Field Of View Of A Spacecraft Antenna: Analysis And Software

Report summarizes computational analysis of field of view of rotating elliptical-cross-section parabolic-reflector antenna for SeaWinds spacecraft. Issues considered include blockage and diffraction by other objects near antenna, related concerns about electromagnetic interference and electromagnetic compatibility, and how far and in which configuration other objects positioned with respect to antenna to achieve required performance.

Wu, Te-Kao↗

Wavefront error sensing

A two-step approach to wavefront sensing for the Large Deployable Reflector (LDR) was examined as part of an effort to define wavefront-sensing requirements and to determine particular areas for more detailed study. A Hartmann test for coarse alignment, particularly segment tilt, seems feasible if LDR can operate at 5 microns or less. The direct measurement of the point spread function in the diffraction limited region may be a way to determine piston error, but this can only be answered by a detailed software model of the optical system. The question of suitable astronomical sources for either test must also be addressed.

Tubbs, Eldred F.↗

NASA airborne satellite instrumentation calibrator (NASIC) technical reference

The NASA Satellite Instrumentation Calibrator (NASIC) is a visible and near-infrared spectrometer used to calibrate various satellite instruments by underflying those instruments in a NASA ER-2 aircraft. The calibration instrument's hardware and software are documented. The design, operation, and function of an Ebert-Fastie monochronomator, which by means of a moveable diffraction grating, becomes a visible and near-infrared spectrometer used to calibrate satellite-borne instruments by high altitude underflights in the NASA ER-2.

Ward, John L.↗