Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffractive optics laser velocimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Diamond formation in double-shocked epoxy to 150 GPa

We present measurements of diamond formation in doubly shocked Stycast 1266 epoxy (comprising C, H, Cl, N, and O) using in situ x-ray diffraction. Epoxy samples were reshocked against a LiF window to pressures between 80 and 148 GPa in experiments at the Omega Laser Facility. Furthermore, the pressure and temperature conditions were diagnosed in situ using velocimetry and optical pyrometry, respectively. X-ray diffraction patterns of the compressed epoxy are consistent with cubic diamond (Fd3¯m), indicating that diamond can precipitate not only from twice-shocked CH polystyrene [Kraus et al. Nat. Astron. 1, 606 (2017)] at these conditions but also from twice-shocked CH polymers with the addition of oxygen, nitrogen, and chlorine. These results, in combination with previous works on CH, CH 2 , CH 4 , and methane hydrate, support that diamond often, but not always, forms from CH-based compounds at extreme pressures and temperatures, indicating that the chemical composition, thermodynamic compression path, and kinetics play an important role.

36 MATERIALS SCIENCE↗

Effect of grain size on damage and failure in two-phase materials: Homogenized CuPb

It is well known that spall failure strongly depends on the microstructure of a material. There have been numerous studies to study the effect of grain size on the overall spall strength and the total amount of damage in single element metals like copper. However, such systematic studies remain rare in two-phase materials and alloys. In this work, two incipient spall experiments were performed on a Cu–1%Pb alloy to understand the effect of grain size on the damage and failure in a two-phase material. Overall, these results showed that even though the spall strength did not change as a function of grain size, there were significant differences in the total amount of damage as a function of grain size. A clear increase in the total damage present in the material was seen as the grain size was increased from 32 to either 70 or 75 μm in either of the experiments. Furthermore, this difference was attributed to variations in the void growth rate as the grain size was increased.

36 MATERIALS SCIENCE↗

X-ray diffraction measurements and pressure determination in nanosecond compression of solids up to 600 GPa

X-ray diffraction measurements under laser-driven dynamic compression now allow us to investigate the atomic structure of matter at TPa pressures and thousands of degree temperatures with broad implications for condensed matter physics, planetary science and astronomy. Furthermore, pressure determination in these experiments often relies on velocimetry measurements coupled with modeling that requires accurate knowledge of the optical and thermo-mechanical properties of a window material, resulting in significant systematic uncertainty. Here we demonstrate different approach applicable to X-ray diffraction experiments under quasi-isentropic ramp-compression based on the use of in-situ pressure calibrants, similar to the methods often adopted in static-compression experiments with diamond anvil cells. Focusing on experiments using a diamond window, we discuss challenges and mitigation strategies for the novel approach. Our study, in addition to providing new structural information of 5 metals up to hundreds of GPa, provides validation to the currently used methods based on time-resolved measurement of the diamond free-surface velocity, and reveals that the use of in-situ calibrants enables a factor of four reduction in the pressure uncertainty in these experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Arrays of glass wedges for multi-dimensional optical diagnostics

There is a common need in the advancement of optical diagnostic techniques to increase the dimensionality of measurements. For example, point measurements could be improved to multi-point, line, planar, volumetric, or time-resolved volumetric measurements. In this work, a unique optical element is presented to enable multi-dimensional measurements, namely, an array of glass wedges. A light source is passed through the wedges, and different portions of the illumination are refracted by different amounts depending on the glass wedge angle. Subsequent optics can be used to focus the light to multiple points, lines, or planes. Basic characterization of a glass wedge array is presented. Additional wedge-array configurations are discussed, including the use of a periodic intensity mask for multi-planar measurements via structured illumination. The utility of this optical element is briefly demonstrated in (a) multi-planar flame particulate measurements, (b) multi-point femtosecond-laser electronic excitation tagging for flow velocimetry, and (c) multi-line nitric oxide molecular tagging velocimetry in a hypersonic shock-tunnel. One significant advantage of this optical component is its compatibility with high-energy laser sources, which may be a limiting factor with other beam-splitting or beam-forming elements such as some diffractive optics. Additionally, an array of glass wedges is simple and easily customizable compared to other methods for forming multiple closely spaced illumination patterns. In conclusion, suggestions for further development and applications are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spall damage mechanisms in laser powder bed fabricated stainless steel 316L

This paper reports on spall damage mechanisms in laser powder bed fusion (LPBF) fabricated stainless steel 316L (SS316L) subjected to uniaxial, strain plate-impact loading and explores failure evolution with increasing impact velocity and peak pressure. Analysis of velocimetry profiles reveals a heterogeneous failure response with several different failure mechanisms activated during impact and resulting spall. The analysis is supported by optical microscopy and electron backscattered diffraction (EBSD) observation of soft recovered impacted samples, which show evidence of localized nano-twinning, twin growth, severe grain rotation, and grain refinement along the spall plane, in addition to pore nucleation, coalescence, and growth. Furthermore, the observed failure mechanisms, including crack formation and propagation along high angle grain boundaries (HAGBs), are not consistently indicative of ductile fracture typical of wrought stainless steel.

36 MATERIALS SCIENCE↗

Design and Characterization of a Lens-Coupled System for Dynamic X-Ray Diffraction

X-ray diffraction (XRD) is a necessary technique for understanding states of materials under static and dynamic loading conditions. The higher-pressure Equation of State (EOS) of many materials can only be explored via shock or ramp compression at temperatures and pressures of interest. While static XRD work has yielded EOS measurements in the 100 - 200 GPa regime, dynamic X-ray diffraction (DXRD) can explore EOS phases in the TPa regime, which closely resembles inner-core planetary conditions. DXRD hinges on the ability to measure the exact phase or phase change of a material while under dynamic loading conditions. Macroscopic diagnostic systems (e.g. velocimetry and pyrometry) can infer a phase change but not identify the specific phase entered by a material. While microscopic (atomic-level) diagnostic systems (e.g. DXRD) have been designed and implemented in Department of Energy’s (DOE) National Laboratories complex, the unique nature of Sandia National Laboratories’ Pulsed Power Facility (Z Machine) prohibits the use of such devices. The destructive nature of Z experiments presents a challenge to data capture and retrieval. Furthermore there are electromagnetic interference, X-ray background, and mechanical constraints to consider. Thus, a multi-part X-ray diagnostic for use on the Z Machine and Z-Beamlet Laser system has been designed and analyzed. Portions of this new DYnamic SCintillator Optic (DYSCO) have been built, tested and fielded. A data analysis software has been written. Finally, the radiance profile of the DYSCO’s scintillator has been characterized through experiments performed at the University of Arizona.

36 MATERIALS SCIENCE↗

Exploring the High-Pressure Phases of Carbon through X-ray Diffraction of Dynamic Compression Experiments on Sandia’s Z Pulsed Power Facility

The carbon phase diagram is rich with polymorphs which possess very different physical and optical properties ideal for different scientific and engineering applications. An understanding of the dynamically driven phase transitions in carbon is particularly important for applications in inertial confinement fusion, as well as planetary and meteorite impact histories. Experiments on the Z Pulsed Power Facility at Sandia National Laboratories generate dynamically compressed high-pressure states of matter with exceptional uniformity, duration, and size that are ideal for investigations of fundamental material properties. X-ray diffraction (XRD) is an important material physics measurement because it enables direct observation of the strain and compression of the crystal lattice, and it enables the detection and identification of phase transitions. Several unique challenges of dynamic compression experiments on Z prevent using XRD systems typically utilized at other dynamic compression facilities, so novel XRD diagnostics have been designed and implemented. We performed experiments on Z to shock compress carbon (pyrolytic graphite) samples to pressures of 150–320 GPa. The Z-Beamlet Laser generated Mn-Heα (6.2 keV) X-rays to probe the shock-compressed carbon sample, and the new XRD diagnostics measured changes in the diffraction pattern as the carbon transformed into its high-pressure phases. Quantitative analysis of the dynamic XRD patterns in combination with continuum velocimetry information constrained the stability fields and melting of high-pressure carbon polymorphs.

36 MATERIALS SCIENCE↗

Measuring the structure and equation of state of polyethylene terephthalate at megabar pressures

Abstract We present structure and equation of state (EOS) measurements of biaxially orientated polyethylene terephthalate (PET, $$({\hbox {C}}_{10} {\hbox {H}}_8 {\hbox {O}}_4)_n$$ ( C 10 H 8 O 4 ) n , also called mylar) shock-compressed to ( $$155 \pm 20$$ 155 ± 20 ) GPa and ( $$6000 \pm 1000$$ 6000 ± 1000 ) K using in situ X-ray diffraction, Doppler velocimetry, and optical pyrometry. Comparing to density functional theory molecular dynamics (DFT-MD) simulations, we find a highly correlated liquid at conditions differing from predictions by some equations of state tables, which underlines the influence of complex chemical interactions in this regime. EOS calculations from ab initio DFT-MD simulations and shock Hugoniot measurements of density, pressure and temperature confirm the discrepancy to these tables and present an experimentally benchmarked correction to the description of PET as an exemplary material to represent the mixture of light elements at planetary interior conditions.

36 MATERIALS SCIENCE↗

Calibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL

In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.

47 OTHER INSTRUMENTATION↗