Search NASA⌕ Search

SEARCH · Search NASA

Results for “digital frequency multiplexing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Readout Noise of Digital Frequency Multiplexed TES Detectors for CUPID

The superconducting transition-edge sensor (TES) detectors have been the standard in cosmic microwave background (CMB) experiments for almost two decades and are now being adapted for use in nuclear physics, such as neutrinoless double beta decay searches. In this article, we focus on a new high-bandwidth frequency multiplexed TES readout system developed for CUPID, a neutrinoless double beta decay experiment that will replace CUORE. In order to achieve the high energy resolution requirements for CUPID, the readout noise of the system must be kept to a minimum. Low TES operating resistance and long wiring between the readout SQUID and the warm electronics are needed for CUPID, prompting a careful consideration of the design parameters of this application of frequency multiplexing. In this work, we characterize the readout noise of the newly designed frequency multiplexed TES readout system for CUPID and construct a noise model to understand it. Here, we find that current sharing between the SQUID coil impedance and other branches of the circuit, as well as the long output wiring, worsen the readout noise of the system. To meet noise requirements, a SQUID with a low input inductance, high transimpedance, and/or low dynamic impedance is needed, and the wiring capacitance should be kept as small as possible. Alternatively, the option of adding a cryogenic low-noise amplifier at the output of the SQUID should be explored.

CUPID↗

Performance and characterization of the SPT-3G digital frequency-domain multiplexed readout system using an improved noise and crosstalk model

The third-generation South Pole Telescope camera (SPT-3G) improves upon its predecessor (SPTpol) by an order of magnitude increase in detectors on the focal plane. The technology used to read out and control these detectors, digital frequency-domain multiplexing (DfMUX), is conceptually the same as used for SPTpol, but extended to accommodate more detectors. A nearly 5× expansion in the readout operating bandwidth has enabled the use of this large focal plane, and SPT-3G performance meets the forecasting targets relevant to its science objectives. However, the electrical dynamics of the higher-bandwidth readout differ from predictions based on models of the SPTpol system due to the higher frequencies used and parasitic impedances associated with new cryogenic electronic architecture. To address this, we present an updated derivation for electrical crosstalk in higher-bandwidth DfMUX systems and identify two previously uncharacterized contributions to readout noise, which become dominant at high bias frequency. The updated crosstalk and noise models successfully describe the measured crosstalk and readout noise performance of SPT-3G. These results also suggest specific changes to warm electronics component values, wire-harness properties, and SQUID parameters, to improve the readout system for future experiments using DfMUX, such as the LiteBIRD space telescope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Seeing in with X-rays: 4D Strain and Thermometry Measurements for Thermal-Mechanical Testing

Understanding temperature-dependent material decomposition and structural deformation induced by combined thermal-mechanical environments is critical for safety qualification of hardware under accident scenarios. Seeing in with X-rays elucidated the physics necessary to develop X-ray strain and thermometry diagnostics for use in optically opaque environments. Two parallel thermometry schemes were explored: X-ray fluorescence and X-ray diffraction of inorganic doped ceramics– colloquially known as thermographic phosphors. Two parallel surface strain techniques–Path-Integrated Digital Image Correlation and Frequency Multiplexed Digital Image Correlation–were demonstrated. Finally, preliminary demonstration of time-resolved digital volume correlation was performed by taking advantage of limited view reconstruction techniques. Additionally, research into blended ceramic-metal coatings was critical to generating intrinsic thermographic patterns for the future combination of X-ray strain and thermometry measurements.

36 MATERIALS SCIENCE↗

622-Mbps Orthogonal Frequency Division Multiplexing (OFDM) Digital Modem Implemented

Future generation space communications systems feature significantly higher data rates and relatively smaller frequency spectrum allocations than systems currently deployed. This requires the application of bandwidth- and power-efficient signal transmission techniques. There are a number of approaches to implementing such techniques, including analog, digital, mixed-signal, single-channel, or multichannel systems. In general, the digital implementations offer more advantages; however, a fully digital implementation is very difficult because of the very high clock speeds required. Multichannel techniques are used to reduce the sampling rate. One such technique, multicarrier modulation, divides the data into a number of low-rate channels that are stacked in frequency. Orthogonal frequency division multiplexing (OFDM), a form of multicarrier modulation, is being proposed for numerous systems, including mobile wireless and digital subscriber link communication systems. In response to this challenge, NASA Glenn Research Center's Communication Technology Division has developed an OFDM digital modem (modulator and demodulator) with an aggregate information throughput of 622 Mbps. The basic OFDM waveform is constructed by dividing an incoming data stream into four channels, each using either 16- ary quadrature amplitude modulation (16-QAM) or 8-phase shift keying (8-PSK). An efficient implementation for an OFDM architecture is being achieved using the combination of a discrete Fourier transform (DFT) at the transmitter to digitally stack the individual carriers, inverse DFT at the receiver to perform the frequency translations, and a polyphase filter to facilitate the pulse shaping.

Kifle, Muli↗

Equivalence of time-multiplexed and frequency-multiplexed signals in digital communications.

In comparing different techniques for multiplexing N binary data signals into a single channel, time-division multiplexing (TDM) is known to have a theoretic efficiency of 100 percent (neglecting sync power) and thus seems to outperform frequency-division multiplexing systems (FDM). By considering more general FDM systems, we will show that both TDM and FDM are equivalent and have an efficiency of 100 percent. The difference between the systems is in the multiplexing and demultiplexing subsystems, but not in the performance or in the generated waveforms.

Timor, U.↗

Low Noise Frequency-Domain Multiplexing of TES Bolometers Using SQUIDs at Sub-Kelvin Temperature

Digital Frequency-Domain Multiplexing (DfMux) is a technique that uses MHz superconducting resonators and Superconducting Quantum Interference Device (SQUID) arrays to read out sets of transition edge sensors. DfMux has been used by several Cosmic Microwave Background experiments, including most recently POLARBEAR-2 and SPT-3 G with multiplexing factors as high as 68, and is the baseline readout technology for the planned satellite mission LiteBIRD. Here, we present recent work focused on improving DfMux readout noise, reducing parasitic impedance, and improving sensor operation. We have achieved a substantial reduction in stray impedance by integrating the sensors, resonators, and SQUID array onto a single-carrier board operated at 250 mK. This also drastically simplifies the packaging of the cryogenic components and leads to better-controlled crosstalk. We demonstrate a low readout noise level of 8.6 pA/Hz1 1/2 , which was made possible by operating the SQUID array at a reduced temperature and with a low dynamic impedance. This is a factor of two improvement compared to the achieved readout noise level in currently operating Cosmic Microwave Background experiments using DfMux and represents a critical step toward maturation of the technology for the next generation of instruments.

47 OTHER INSTRUMENTATION↗

Convolution-based frequency domain multiplexing of SiPM readouts using the $\mathrm{DRS4}$ digitizer

Here we present 4:1 multiplexing of organic scintillators, each coupled to a silicon photomultiplier (SiPM), to reduce the need for a large number of digitizer input channels to readout highly pixelated radiation detection systems. Frequency domain multiplexing (FDM) encodes a detector pulse by assigning it a unique frequency via convolution before combining the encoded signal into a single channel. The combined signal is then read through a digitizer input channel. We have designed an FDM system to multiplex four SiPMs using DRS4 digitizer evaluation board from Paul Scherrer Institute (PSI). We demonstrate 4:1 multiplexing of the SiPM fast output signals and pulse recovery from the digitized multiplexed signal using deconvolution. The noise in the recovered pulse introduces a bias and uncertainty in the estimate of energy and timing that changes with pulse height. The relative uncertainty in the estimated energy from the recovered pulse decreases with pulse height with a maximum uncertainty of 3.1% for the low energy pulses (corresponding to 100 keV); the uncertainty in the estimated time pick-off also decreases with pulse height with a maximum uncertainty of 110 ps for the low energy pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding the Phase of Responsivity and Noise Sources in Frequency-Domain Multiplexed Readout of Transition Edge Sensor Bolometers

Abstract Cosmic microwave background (CMB) experiments have deployed focal planes with $$\mathcal {O}(10^{4})$$ O ( 10 4 ) transition edge sensor (TES) bolometers cooled to sub-Kelvin temperatures by multiplexing the readout of many TES channels onto a single pair of wires. Digital Frequency-domain Multiplexing (DfMux) is a multiplexing technique used in many CMB polarization experiments, such as the Simons Array, SPT-3 G, and EBEX. The DfMux system studied here uses LC filters with resonant frequencies ranging from 1.5 to 4.5 MHz connected to an array of TESs. Each detector has an amplitude-modulated carrier tone at the resonant frequency of its accompanying LC resonator. The signal is recovered via quadrature demodulation where the in-phase (I) component of the demodulated current is in phase with the complex admittance of the circuit and the quadrature (Q) component is orthogonal to I. Observed excess current noise in the Q component is consistent with fluctuations in the resonant frequency. This noise has been shown to be non-orthogonal to the phase of the detector’s responsivity. We present a detailed analysis of the phase of responsivity of the TES and noise sources in our DfMux readout system. Further, we investigate how modifications to the TES operating resistance and bias frequency can affect the phase of noise relative to the phase of the detector responsivity, using data from Simons Array to evaluate our predictions. We find that both the phase of responsivity and phase of noise are functions of the two tuning parameters, which can be purposefully selected to maximize signal-to-noise (SNR) ratio.

47 OTHER INSTRUMENTATION↗

Implementation of a 622 Mbps Digital Modem

This paper presents the implementation and initial test results of an Orthogonal Frequency Division Multiplexing (OFDM) digital modem (modulator and demodulator) with an aggregate information throughput of 622 megabits per second (Mbps). The OFDM waveform is constructed by dividing an incoming data stream into four channels, each channel using either a 16-ary Quadrature Amplitude Modulation (16QAM) scheme or an 8-Phase Shift Keying (8PSK) scheme. The generation and detection of the composite waveform are performed using Discrete Fourier Transform (DFT) and polyphase filtering, to digitally stack and band-limit the individual carriers respectively. The four-channel OFDM approach enables the implementation of a modem that can be both power and bandwidth efficient, with sufficient parallelism to meet higher data rate goals. As a result, the OFDM modem requires only a 240 MHz bandwidth to transmit 622 Mbps. Hardware and simulation results in the form of spectrum diagrams and bit-error-rate (BER) curves are also presented in this paper.

Kifle, Muli↗

The Design and Integrated Performance of SPT-3G

Abstract SPT-3G is the third survey receiver operating on the South Pole Telescope dedicated to high-resolution observations of the cosmic microwave background (CMB). Sensitive measurements of the temperature and polarization anisotropies of the CMB provide a powerful data set for constraining cosmology. Additionally, CMB surveys with arcminute-scale resolution are capable of detecting galaxy clusters, millimeter-wave bright galaxies, and a variety of transient phenomena. The SPT-3G instrument provides a significant improvement in mapping speed over its predecessors, SPT-SZ and SPTpol. The broadband optics design of the instrument achieves a 430 mm diameter image plane across observing bands of 95, 150, and 220 GHz, with 1.2′ FWHM beam response at 150 GHz. In the receiver, this image plane is populated with 2690 dual-polarization, trichroic pixels (∼16,000 detectors) read out using a 68× digital frequency-domain multiplexing readout system. In 2018, SPT-3G began a multiyear survey of 1500 deg 2 of the southern sky. We summarize the unique optical, cryogenic, detector, and readout technologies employed in SPT-3G, and we report on the integrated performance of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A wideband-PCM recorder for the Space Shuttle orbiter

The Shuttle wideband-PCM recorder accomplishes recording on up to 14 data tracks with analog or digital data inputs. FM multiplexed analog frequencies of up to 2 MHz and digital rates of 1 Mb/s are accommodated at a tape speed of 120 in/s. Recording time in analog mode varies between 4 min for 2 MHz data to 80 min for 100 kHz data. The total digital data storage is 3.44 x 10 to the 9th bits with recording times from 1 hour for 1 Mb/s to 19 hours for 50 Kb/s data in the serial track switching mode. A versatile command decoder and control interface are used for eight primary modes of operation.

Petit, R. D.↗

Hyperspectral X-ray Imaging with TES Detectors for Nanoscale Chemical Speciation Mapping

We are developing an imaging capability (“Hyperspectral X-ray Imaging”) for mapping chemical information (molecular formula, phase, oxidation state, hydration) that is based on ultra-high-resolution X-ray emission spectroscopy with large transition-edge sensor microcalorimeter arrays in the scanning electron microscope. By combining microcalorimeter arrays with hundreds of pixels, high-bandwidth microwave frequency-division multiplexing, and fast digital electronics for near real-time data processing, our goal is to enable measurements using laboratory-scale instrumentation rather than synchrotron beamlines. Our application focus here is on mapping the chemical form of uranium compounds on the nanoscale. Furthermore, we will present our approach to developing the Hyperspectral X-ray Imaging capability, progress toward a 128-pixel microwave multiplexed X-ray fluorescence instrument at LANL, and the path to high-throughput nanoscale chemical mapping.

47 OTHER INSTRUMENTATION↗

Application of deconvolution to recover frequency-domain multiplexed detector pulses

Multiplexing of radiation detectors reduces the number of readout channels, which in turn reduces the number of digitizer input channels for data acquisition. We recently demonstrated frequency domain multiplexing (FDM) of pulse mode radiation detectors using a resonator that converts the detector signal into a damped sinusoid by convolution. The detectors were given unique “tags” by the oscillation frequency of each resonator. The charge collected and the time-of-arrival of the detector pulse were estimated from the corresponding resonator output in the frequency domain. In this paper, we demonstrate a new method to recover the detector pulse from the damped sinusoidal output by deconvolution. Deconvolution converts the frequency-encoded detector signal back to the original detector pulse. We have developed a new prototype FDM system to multiplex organic scintillators based on convolution and deconvolution. Using the new prototype, the charge collected under the anode pulse can be estimated from the recovered pulse with an uncertainty of about 4.4 keVee (keV electron equivalent). The time-of-arrival can be estimated from the recovered pulse with an uncertainty of about 102 ps. We also used a CeBr3 inorganic scintillator to measure the Cs-137 gamma spectrum using the recovered pulses and found a standard deviation of 13.8 keV at 662 keV compared to a standard deviation of 13.5 keV when the original pulses were used. Coincidence measurements with Na-22 using the deconvolved pulses resulted in a timing uncertainty of 617 ps compared to an uncertainty of 603 ps using the original pulses. Pulse shape discrimination was also performed using Cf-252 source and EJ-309 organic scintillator pulses recovered by deconvolution. In conclusion, a figure of merit value of 1.08 was observed when the recovered pulses were used compared to 1.2 for the original pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of Frequency Division Multiplexing and Neural Networks in the Operation and Diagnosis of the Stator Current and Shaft Position Sensors Used in Electric/Hybrid Vehicles

Fast, precise and robust sensing of currents and motor shaft angle is essential for the excellent performance of electric and hybrid vehicles (EV/HEV). Multiplexing techniques are commonly applied in data acquisition systems (DAQs) to digitize the signals sensed in EV/HEV drives. Frequency-division multiplexing (FDM) applied to get the signals from current sensors and resolver angular position sensor has advantages over conventional multiplexing approaches. However, problems such as aging and mechanical imperfections distort the outputs of those sensors, producing measurement errors of the angular position and currents. Conventional techniques designed to compensate for those errors cannot be applied in signals multiplexed in frequency. This paper proposes online techniques to detect and compensate for the distortions in the resolver sensor and current sensors. The demultiplexing process was adjusted to allow distortion detection and compensation. An auto-associative neural network (ANN) compensates for the current measurement error, while an energy-based technique is applied to compensate for the distortions in the resolver outputs. The obtained results show that the distortions were compensated, allowing a more accurate estimation of stator currents and angular position when FDM is applied in EV/HEV DAQs.

Pereira Pinto, Joao↗

Microcomputerized electric field meter diagnostic and calibration system

A computerized field meter calibration system which includes an apparatus for testing the calibration of field meters normally utilized for measuring electromagnetic field potentials is described. A reference voltage is applied to the field meter for causing signals to be produced on the output terminals thereof. A bank of relays is provided for selectively connecting output terminals of the field meter to a multiplexer by means of a digital voltmeter and an oscilloscope. A frequency-shift-keyed receiver is also connected to one of the terminals of the field meter for transmitting and converting a frequency shift keyed signal to a digital signal which is, subsequently, applied to the multiplexer.

Holley, L. D.↗

Recovery of coincident frequency domain multiplexed detector pulses using sequential deconvolution

Multiplexing of radiation detector signals into a single channel significantly reduces the need for a large number of digitizer channels, which reduces the cost and the power consumption of a data acquisition system. We previously demonstrated frequency domain multiplexing by convolution using a prototype system that multiplexed two EJ-309 organic scintillators signals into a single channel. Each detector pulse was converted to a damped sinusoid which was then combined into a single channel. The combined signal was digitized and the original detector signal was recovered from the damped sinusoid by deconvolution. In this paper, we demonstrate the recovery of multiple detector signals that arrive during the same digitized record via a new sequential deconvolution method. Here, when two detectors produce signals in the same digitized record and their pulses do not overlap in time, we found that the charge, arrival time, and particle type can be estimated fairly precisely for the first pulse, but the second pulse exhibits substantial degradation in the precision of the estimated charge and arrival time. When the pulses overlap in time, we demonstrate both theoretically and experimentally that the part of the first pulse that does not overlap with the second can be recovered accurately, so the arrival time and amplitude of the first pulse can be estimated fairly precisely, but not the charge or particle type. None of these quantities can be estimated precisely for the second pulse when the two pulses overlap.

47 OTHER INSTRUMENTATION↗

Digital servo control of random sound test excitation

A digital servocontrol system for random noise excitation of a test object in a reverberant acoustic chamber employs a plurality of sensors spaced in the sound field to produce signals in separate channels which are decorrelated and averaged. The average signal is divided into a plurality of adjacent frequency bands cyclically sampled by a time division multiplex system, converted into digital form, and compared to a predetermined spectrum value stored in digital form. The results of the comparisons are used to control a time-shared up-down counter to develop gain control signals for the respective frequency bands in the spectrum of random sound energy picked up by the microphones.

Nakich, R. B.↗