SEARCH · Search NASA
Results for “direct detectors”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Coherent elastic neutrino-nucleus scattering with directional detectors
We study the sensitivity of detectors with directional sensitivity to coherent elastic neutrino-nucleus scattering (CE$\textit{ν}$NS), and how these detectors complement measurements of the nuclear recoil energy. In this work we consider stopped pion and reactor neutrino sources, and use gaseous helium and fluorine as examples of detector material. We generate Standard Model predictions, and compare to scenarios that include new, light vector or scalar mediators. We show that directional detectors can provide valuable additional information in discerning new physics, and we identify prominent spectral features in both the angular and the recoil energy spectrum for light mediators, even for nuclear recoil energy thresholds as high as ~50 keV. Combined with energy and timing information, directional information can play an important role in extracting new physics from CE$\textit{ν}$NS experiments.
A Directional Detector Response Function for Anisotropic Detectors
For a radiation detector that is not isotropic, a directional detector response is needed to accurately account for the variation in a detector’s behavior depending on the incoming particle direction. The concept of the detector response function has been extended to include particle direction using a set of pregenerated detector responses based on the orientation of the incoming radiation and the detector. This directional detector response function (DDRF) then can be applied to the flux and current tallies computed by a Monte Carlo simulation. Validation of the new approach has been done by comparing simulated count rates processed with the DDRF to measured count rates taken with a 5.08 × 10.16 × 40.64-cm NaI(Tl) detector. The comparisons show that the applied method produces good agreement with both background and source measurements with a 137 Cs source. Furthermore, separation of the detector response generation from Monte Carlo particle transport calculations provides greater flexibility in locating single or multiple detectors without any interference in the model and also enables simulation of various models using the same detector response without the need for generating additional detector responses if the same detector is being used.
Direct detector for terahertz radiation
A direct detector for terahertz radiation comprises a grating-gated field-effect transistor with one or more quantum wells that provide a two-dimensional electron gas in the channel region. The grating gate can be a split-grating gate having at least one finger that can be individually biased. Biasing an individual finger of the split-grating gate to near pinch-off greatly increases the detector's resonant response magnitude over prior QW FET detectors while maintaining frequency selectivity. The split-grating-gated QW FET shows a tunable resonant plasmon response to FIR radiation that makes possible an electrically sweepable spectrometer-on-a-chip with no moving mechanical optical parts. Further, the narrow spectral response and signal-to-noise are adequate for use of the split-grating-gated QW FET in a passive, multispectral terahertz imaging system. The detector can be operated in a photoconductive or a photovoltaic mode. Other embodiments include uniform front and back gates to independently vary the carrier densities in the channel region, a thinned substrate to increase bolometric responsivity, and a resistive shunt to connect the fingers of the grating gate in parallel and provide a uniform gate-channel voltage along the length of the channel to increase the responsivity and improve the spectral resolution.
SUBMM wave superconduction hot-electron direct detectors
Recently, we have presented a concept for a hot-electron direct detector (HEDD) capable of counting single millimeter-wave photons. Such a detector meets the needs of future space far-infrared applications and can be used for background-limited detector arrays on missions like SPIRIT, 10-m filled aperture telescope, SAFIR, and SPECS.
Apparatus for use in a directional-neutron detector, directional-neutron detectors and methods of use thereof
An apparatus for used in a directional-neutron detector is disclosed. The apparatus comprises a structure having a plurality of parallel active channels separated by inactive regions. The plurality of active channels is filled with scintillating material. The scintillating material is configured to emit light in response to neutron scattering. The scintillating material may be neutron-gamma discriminating. The scintillating material may be sealed in the plurality of active channels. The seal is disposed on respective ends of the plurality of active channels. Directional-neutron detectors are also disclosed having the structure.
Directional radiation detectors
Directional radiation detectors and systems, methods, and computer-readable media for using directional radiation detectors to locate a radiation source are provided herein. A directional radiation detector includes a radiation sensor. A radiation attenuator partially surrounds the radiation sensor and defines an aperture through which incident radiation is received by the radiation sensor. The aperture is positioned such that when incident radiation is received directly through the aperture and by the radiation sensor, a source of the incident radiation is located within a solid angle defined by the aperture. The radiation sensor senses at least one of alpha particles, beta particles, gamma particles, or neutrons.
Radiation direction detector including means for compensating for photocell aging Patent
Solar radiation direction detector and device for compensating degradation of photocells
Photon-Noise Limited Direct Detector Based on Disorder-Controlled Electron Heating
We present a new concept for a hot-electron direct detector (HEDD) capable of counting single millimeter-wave photons. The detector is based on a transition edge sensor (1-meu size bridge) made form a disordered superconducting film.
Hot-electron direct detectors: feasibility of NEP = 10(sup -20) W/Hz at submillimeter waves
Recently we have presented a concept for a hot-electron direct detector (HEDD) capable of counting single millimeter-wave photons.
Probing the local velocity distribution of WIMP dark matter with directional detectors
We explore the ability of directional nuclear-recoil detectors to constrain the local velocity distribution of weakly interacting massive particle (WIMP) dark matter by performing Bayesian parameter estimation on simulated recoil-event data sets. We discuss in detail how directional information, when combined with measurements of the recoil-energy spectrum, helps break degeneracies in the velocity-distribution parameters. We also consider the possibility that velocity structures such as cold tidal streams or a dark disk may also be present in addition to the Galactic halo. Assuming a CF{sub 4} detector with a 30-kg-yr exposure, a 50-GeV WIMP mass, and a WIMP-nucleon spin-dependent cross-section of 10{sup −3}pb, we show that the properties of a cold tidal stream may be well constrained. However, measurement of the parameters of a dark-disk component with a low lag speed of ∼ 50km/s may be challenging unless energy thresholds are improved.
Novel Deployment of Elpasolites as a Dual Neutron/Gamma-Ray Directional Detector
At a time when upholding national security has never been more important, there exists a need for the advancement of radiation detection technologies. Neutron and photon detectors are essential to fulfilling mission areas including detection and localization of missing, stolen or smuggled radiological or nuclear materials, quantification of the effects of a radiological or nuclear event, and supporting nonproliferation efforts. The aim of this study was to evaluate a new radiation detector based on the scintillation elpasolite compound Cs 2 LiYCl 6 :Ce (CLYC) for simultaneous measurements of neutron and photon flux and the localization of radiation sources. Previous studies performed on the CLYC scintillator indicate its potential for thermal neutron and gamma-ray measurements. This study is dedicated to the novel application of the CLYC as a dual neutron / photon detector and as part of a directional detection system. Both computational modeling and an experimental study were carried out within this research project. As part of the computational study, the response of a CLYC scintillator detector to gamma rays induced by thermal neutron interaction with Cl and 7 Li nuclei was investigated using the MCNP6 code. In addition, arrays of three and four CLYC detectors were modeled in order to evaluate the directional detection of both a thermal neutron source and a gamma-ray source. It was shown that little or no quality of source direction determination would be lost when three detectors were used in the array compared to four detectors. In the experimental study, the photon spectroscopy capabilities of the CLYC detectors were evaluated. A gamma-ray energy resolution of 4.9% was measured for the 662-keV peak of 137 Cs and 3.6% for the 1.33-MeV peak of 60 Co. Using a thermal neutron source, the pulse shape discrimination analysis was successfully performed for the CLYC detector signal waveforms. Thermal neutrons and gamma rays were separated with an exceptional figure of merit (FOM) of 2.3. An array of three CLYC detectors was assembled for the purpose of directional neutron / gamma-ray detection. The intrinsic peak efficiency of CLYC detectors was evaluated. The three-CLYC detector array was deployed for directional measurements with a single gamma-ray 137 Cs source, two gamma-ray sources of 137 Cs and 60 Co isotopes and a thermal neutron source designed using a 239PuBe neutron source supplied with a polyethylene moderator. Measurements were carried out using sources located in the longitude and latitude planes over the angles from 0° to 360°. The measured data were processed through a maximum likelihood estimation algorithm providing a possible direction for which the radioactive source in each case was positioned. The estimated directions were close if not exact matches for the actual directions to the radioactive source. The largest discrepancy in direction produced by the algorithm was approximately 11%. However, it was hypothesized that this percent error can be decreased by homogenizing the directional detection system to consist of scintillators of the same size and quality, identical photomultiplier tubes and identical aluminum housings. The feasibility of this hypothesis to decrease the percent error was confirmed by the zero percent error achieved in the directional measurements produced in the computational study utilizing a homogenous directional detection system. The results of computational and experimental studies completed within this research project provide means to propose the array of three CLYC scintillators as an efficient dual neutron / gamma-ray directional detector.
Direct Detection of Pu-242 with a Metallic Magnetic Calorimeter Gamma-Ray Detector
Abstract not provided
Decision-directed detector for overlapping PCM/NRZ signals.
A decision-directed (DD) technique for the detection of overlapping PCM/NRZ signals in the presence of white Gaussian noise is investigated. The performance of the DD detector is represented by probability of error Pe versus input signal-to-noise ratio (SNR). To examine how much improvement in performance can be achieved with this technique, Pe's with and without DD feedback are evaluated in parallel. Further, analytical results are compared with those found by Monte Carlo simulations. The results are in good agreement.
Land-surface studies with a directional neutron detector.
Direct measurements of cosmic-ray neutron intensity were recorded with a neutron scatter camera developed at SNL. The instrument used in this work is a prototype originally designed for nuclear non-proliferation work, but in this project it was used to characterize the response of ambient neutrons in the 0.5-10 MeV range to water located on or above the land surface. Ambient neutron intensity near the land surface responds strongly to the presence of water, suggesting the possibility of an indirect method for monitoring soil water content, snow water equivalent depth, or canopy intercepted water. For environmental measurements the major advantage of measuring neutrons with the scatter camera is the limited (60{sup o}) field of view that can be obtained, which allows observations to be conducted at a previously unattainable spatial scales. This work is intended to provide new measurements of directional fluxes which can be used in the design of new instruments for passively and noninvasively observing land-surface water. Through measurements and neutron transport modeling we have demonstrated that such a technique is feasible.
SubMM wave superconducting hot-electron direct detectors
Explore the source record for details and available documents.
A Hot-Electron Far-Infrared Direct Detector
A new approach is proposed to improve the sensitivity of direct-detection bolometers at millimeter, submillimeter and far-infrared wavelengths. The idea is to adjust a speed of the thermal relaxation of hot-electrons in a nanometer size normal metal or super-conductive transition edge bolometer by controlling the elastic electron mean free path. If the bolometer contacts are made of a superconductor with high critical temperature (Nb, Pb etc.) then the thermal diffusion into the contacts is absent because of the Andreev's reflection and the electron-phonon relaxation is the only mechanism for heat removal. The relaxation rate should behave as T(sup 4)l at subkelvin temperatures (l is the electron elastic mean free path) and can be reduced by factor of 10-100 by decreasing l. Then an antenna- or waveguide-coupled bolometer with a time constant about 10(exp -3) to 10(exp -5) s at T approximately equals 0.1-0.3 K will exhibit photon-noise limited performance in millimeter and submillimeter range. The choice of the bolometer material is a tradeoff between a low electron heat capacity and fabrication. A state-of-the-art bolometer currently offers NEP = 10(exp -17) W(Square root of (Hz)) at 100 mK along with a approximately equals 2 msec time constant. The bolometer we propose will have a figure-of-merit, NEP(square root (r)), which is 10(exp 3) times smaller. This will allow for a tremendous increase in speed which will have a significant impact for observational mapping applications. Alternatively, the bolometer could operate at higher temperature with still superior sensitivity. This device can significantly increase a science return and reduce the cost for future observational missions. This research was performed by the Center for Space Microelectronics Technology, Jet Propulsion Laboratory, California Institute of Technology, and was sponsored by NASA, Office of Space Science.
A Hot-electron Direct Detector for Radioastronomy
A new approach is proposed to improve the sensitivity of direct-detection bolometers. The idea is to adjust a speed of the thermal relaxation of hot-electrons in a nanometer size normal metal or superconductive transition edge bolometer by controlling the elastic electron mean free path. If the bolometer contacts are made of a superconductor with high critical temperature then the thermal diffusion into the contacts is absent because of the Andreev's reflection and the electron-phonon relaxation is the only mechanism for heat removal. The relaxation rate should behave as 7(exp 4)l at subkelvin temperatures (l is the electron elastic mean free path) and can be reduced by factor of 10 - 100 by decreasing l. Then an antenna- or waveguide-coupled bolometer with a time constant approx. 10(exp -3) to 10(exp -5) S at T approx. = 0.1 - 0.3 K will exhibit photon-noise limited performance in millimeter and subn-millimeter range. The bolometer will have a figure-of-merit NEk square root of tau approx. = 10(exp -22) 10(exp -21) W/Hz at 100 mK which is 10(exp 3) times smaller than that of a state-of-the-art bolometer. This will allow for a tremendous increase in speed which will have a significant impact for observational mapping applications. Alternatively, the bolometer could operate at higher temperature with still superior sensitivity This research was performed by the Center for Space Microelectronics Technology, JPL, California Institute of Technology, under the contract for NASA.