SEARCH · Search NASA
Results for “direct detectors”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Coherent elastic neutrino-nucleus scattering with directional detectors
We study the sensitivity of detectors with directional sensitivity to coherent elastic neutrino-nucleus scattering (CE$\textit{ν}$NS), and how these detectors complement measurements of the nuclear recoil energy. In this work we consider stopped pion and reactor neutrino sources, and use gaseous helium and fluorine as examples of detector material. We generate Standard Model predictions, and compare to scenarios that include new, light vector or scalar mediators. We show that directional detectors can provide valuable additional information in discerning new physics, and we identify prominent spectral features in both the angular and the recoil energy spectrum for light mediators, even for nuclear recoil energy thresholds as high as ~50 keV. Combined with energy and timing information, directional information can play an important role in extracting new physics from CE$\textit{ν}$NS experiments.
A Directional Detector Response Function for Anisotropic Detectors
For a radiation detector that is not isotropic, a directional detector response is needed to accurately account for the variation in a detector’s behavior depending on the incoming particle direction. The concept of the detector response function has been extended to include particle direction using a set of pregenerated detector responses based on the orientation of the incoming radiation and the detector. This directional detector response function (DDRF) then can be applied to the flux and current tallies computed by a Monte Carlo simulation. Validation of the new approach has been done by comparing simulated count rates processed with the DDRF to measured count rates taken with a 5.08 × 10.16 × 40.64-cm NaI(Tl) detector. The comparisons show that the applied method produces good agreement with both background and source measurements with a 137 Cs source. Furthermore, separation of the detector response generation from Monte Carlo particle transport calculations provides greater flexibility in locating single or multiple detectors without any interference in the model and also enables simulation of various models using the same detector response without the need for generating additional detector responses if the same detector is being used.
Direct detector for terahertz radiation
A direct detector for terahertz radiation comprises a grating-gated field-effect transistor with one or more quantum wells that provide a two-dimensional electron gas in the channel region. The grating gate can be a split-grating gate having at least one finger that can be individually biased. Biasing an individual finger of the split-grating gate to near pinch-off greatly increases the detector's resonant response magnitude over prior QW FET detectors while maintaining frequency selectivity. The split-grating-gated QW FET shows a tunable resonant plasmon response to FIR radiation that makes possible an electrically sweepable spectrometer-on-a-chip with no moving mechanical optical parts. Further, the narrow spectral response and signal-to-noise are adequate for use of the split-grating-gated QW FET in a passive, multispectral terahertz imaging system. The detector can be operated in a photoconductive or a photovoltaic mode. Other embodiments include uniform front and back gates to independently vary the carrier densities in the channel region, a thinned substrate to increase bolometric responsivity, and a resistive shunt to connect the fingers of the grating gate in parallel and provide a uniform gate-channel voltage along the length of the channel to increase the responsivity and improve the spectral resolution.
Apparatus for use in a directional-neutron detector, directional-neutron detectors and methods of use thereof
An apparatus for used in a directional-neutron detector is disclosed. The apparatus comprises a structure having a plurality of parallel active channels separated by inactive regions. The plurality of active channels is filled with scintillating material. The scintillating material is configured to emit light in response to neutron scattering. The scintillating material may be neutron-gamma discriminating. The scintillating material may be sealed in the plurality of active channels. The seal is disposed on respective ends of the plurality of active channels. Directional-neutron detectors are also disclosed having the structure.
Directional radiation detectors
Directional radiation detectors and systems, methods, and computer-readable media for using directional radiation detectors to locate a radiation source are provided herein. A directional radiation detector includes a radiation sensor. A radiation attenuator partially surrounds the radiation sensor and defines an aperture through which incident radiation is received by the radiation sensor. The aperture is positioned such that when incident radiation is received directly through the aperture and by the radiation sensor, a source of the incident radiation is located within a solid angle defined by the aperture. The radiation sensor senses at least one of alpha particles, beta particles, gamma particles, or neutrons.
Probing the local velocity distribution of WIMP dark matter with directional detectors
We explore the ability of directional nuclear-recoil detectors to constrain the local velocity distribution of weakly interacting massive particle (WIMP) dark matter by performing Bayesian parameter estimation on simulated recoil-event data sets. We discuss in detail how directional information, when combined with measurements of the recoil-energy spectrum, helps break degeneracies in the velocity-distribution parameters. We also consider the possibility that velocity structures such as cold tidal streams or a dark disk may also be present in addition to the Galactic halo. Assuming a CF{sub 4} detector with a 30-kg-yr exposure, a 50-GeV WIMP mass, and a WIMP-nucleon spin-dependent cross-section of 10{sup −3}pb, we show that the properties of a cold tidal stream may be well constrained. However, measurement of the parameters of a dark-disk component with a low lag speed of ∼ 50km/s may be challenging unless energy thresholds are improved.
Novel Deployment of Elpasolites as a Dual Neutron/Gamma-Ray Directional Detector
At a time when upholding national security has never been more important, there exists a need for the advancement of radiation detection technologies. Neutron and photon detectors are essential to fulfilling mission areas including detection and localization of missing, stolen or smuggled radiological or nuclear materials, quantification of the effects of a radiological or nuclear event, and supporting nonproliferation efforts. The aim of this study was to evaluate a new radiation detector based on the scintillation elpasolite compound Cs 2 LiYCl 6 :Ce (CLYC) for simultaneous measurements of neutron and photon flux and the localization of radiation sources. Previous studies performed on the CLYC scintillator indicate its potential for thermal neutron and gamma-ray measurements. This study is dedicated to the novel application of the CLYC as a dual neutron / photon detector and as part of a directional detection system. Both computational modeling and an experimental study were carried out within this research project. As part of the computational study, the response of a CLYC scintillator detector to gamma rays induced by thermal neutron interaction with Cl and 7 Li nuclei was investigated using the MCNP6 code. In addition, arrays of three and four CLYC detectors were modeled in order to evaluate the directional detection of both a thermal neutron source and a gamma-ray source. It was shown that little or no quality of source direction determination would be lost when three detectors were used in the array compared to four detectors. In the experimental study, the photon spectroscopy capabilities of the CLYC detectors were evaluated. A gamma-ray energy resolution of 4.9% was measured for the 662-keV peak of 137 Cs and 3.6% for the 1.33-MeV peak of 60 Co. Using a thermal neutron source, the pulse shape discrimination analysis was successfully performed for the CLYC detector signal waveforms. Thermal neutrons and gamma rays were separated with an exceptional figure of merit (FOM) of 2.3. An array of three CLYC detectors was assembled for the purpose of directional neutron / gamma-ray detection. The intrinsic peak efficiency of CLYC detectors was evaluated. The three-CLYC detector array was deployed for directional measurements with a single gamma-ray 137 Cs source, two gamma-ray sources of 137 Cs and 60 Co isotopes and a thermal neutron source designed using a 239PuBe neutron source supplied with a polyethylene moderator. Measurements were carried out using sources located in the longitude and latitude planes over the angles from 0° to 360°. The measured data were processed through a maximum likelihood estimation algorithm providing a possible direction for which the radioactive source in each case was positioned. The estimated directions were close if not exact matches for the actual directions to the radioactive source. The largest discrepancy in direction produced by the algorithm was approximately 11%. However, it was hypothesized that this percent error can be decreased by homogenizing the directional detection system to consist of scintillators of the same size and quality, identical photomultiplier tubes and identical aluminum housings. The feasibility of this hypothesis to decrease the percent error was confirmed by the zero percent error achieved in the directional measurements produced in the computational study utilizing a homogenous directional detection system. The results of computational and experimental studies completed within this research project provide means to propose the array of three CLYC scintillators as an efficient dual neutron / gamma-ray directional detector.
Direct Detection of Pu-242 with a Metallic Magnetic Calorimeter Gamma-Ray Detector
Abstract not provided
Land-surface studies with a directional neutron detector.
Direct measurements of cosmic-ray neutron intensity were recorded with a neutron scatter camera developed at SNL. The instrument used in this work is a prototype originally designed for nuclear non-proliferation work, but in this project it was used to characterize the response of ambient neutrons in the 0.5-10 MeV range to water located on or above the land surface. Ambient neutron intensity near the land surface responds strongly to the presence of water, suggesting the possibility of an indirect method for monitoring soil water content, snow water equivalent depth, or canopy intercepted water. For environmental measurements the major advantage of measuring neutrons with the scatter camera is the limited (60{sup o}) field of view that can be obtained, which allows observations to be conducted at a previously unattainable spatial scales. This work is intended to provide new measurements of directional fluxes which can be used in the design of new instruments for passively and noninvasively observing land-surface water. Through measurements and neutron transport modeling we have demonstrated that such a technique is feasible.
Ultra-High Frame Rate Direct Detector for EBSD and TKD
Explore the source record for details and available documents.
Maximum Likelihood Source Localization Using Elpasolite as a Dual Gamma Neutron Directional Detector
The problem of accurately detecting extremely low levels of nuclear radiation is rapidly increasing in importance in nuclear counter-proliferation, verification, and environmental and waste management. Because the 239Pu gamma signature may be weak, for instance, even when compared to the natural terrestrial background, coincidence counting with the 239Pu neutron signature may improve overall 239Pu detection sensitivity. However, systems with sufficient multiple-particle detectors require demonstration that the increased sensitivity be sufficiently high to overcome added cost and weight. We report the results of measurements and calculations to determine sensitivity that can be gained in detecting low levels of nuclear radiation from use of a relatively new detector technology based on elpasolite crystals. We have performed investigations exploring cerium (Ce3+)-doped elpasolites Cs2LiYCl6:Ce3+0.5% (CLYC) and Cs2LiLa(Br6)90%(Cl6)10%:Ce3+0.5% (CLLBC:Ce). These materials can provide energy resolution (r(E) = 2.35σ(E)/E) as good as 2.9% at 662 keV (FWHM). The crystals show an excellent neutron and gamma radiation response. The goals of the investigation were to set up the neutron/gamma pulse shape discrimination electronics for elpasolite detectors; perform limited static source benchmarking, testing, and evaluation to validate system performance; and explore application of a maximum likelihood algorithm for source location. Data were measured and processed through a maximum likelihood estimation algorithm, providing a direction to the radioactive source for each individual position. The estimated directions were good representations for the actual directions to the radioactive source. This paper summarizes the maximum likelihood results for our elpasolite system.
Magnetic inelastic dark matter: Directional signals without a directional detector
The magnetic inelastic dark matter (MiDM) model, in which dark matter inelastically scatters off nuclei through a magnetic dipole interaction, has previously been shown to reconcile the DAMA/LIBRA annual modulation signal with null results from other experiments. In this work, we explore the unique directional detection signature of MiDM. After the dark matter scatters into its excited state, it decays with a lifetime of order 1 {mu}s and emits a photon with energy {approx}100 keV. Both the nuclear recoil and the corresponding emitted photon can be detected by studying delayed coincidence events. The recoil track and velocity of the excited state can be reconstructed from the nuclear interaction vertex and the photon event vertex. The angular distribution of the WIMP recoil tracks is sharply peaked and modulates daily. It is therefore possible to observe the directional modulation of WIMP-nucleon scattering without a large-volume gaseous directional detection experiment. Furthermore, current experiments such as XENON100 can immediately measure this directional modulation and constrain the MiDM parameter space with an exposure of a few thousand kg{center_dot}day.
Exclusion limits from data of directional dark matter detectors
Directional detection is a promising search strategy to discover Galactic dark matter. Taking advantage on the rotation of the Solar System around the Galactic center through the dark matter halo, it allows us to show a direction dependence of weakly interacting massive particle (WIMP) events. Even though the goal of directional search is to identify a WIMP positive detection, exclusion limits are still needed for very low exposure with a rather large background contamination, such as the one obtained with prototype experiments. Data of directional detectors are composed of energy and a 3D track for all recoiling nuclei. However, to set robust exclusion limits, we focus on the angular part of the event distribution, arguing that the energy part of the background distribution is unknown. As the angular distributions of both background and WIMP events are known, a Bayesian approach to set exclusion limits is possible. In this paper, a new statistical method based on an extended likelihood is proposed, compared to existing ones, and is shown to be optimal. Eventually, a comprehensive study of the effect of a detector configuration on exclusion limits is presented. It includes the effect of having or not sense recognition, a finite angular resolution, taking into account energy threshold as well as some astrophysical uncertainties.
Large Angle Rocking Beam Electron Diffraction Utilizing Electron Direct Detector
Electron diffraction of a crystal is fundamentally a function of the potential of that crystal. The intensity of electron diffraction patterns is, as a result, sensitive to the charge density of atoms and bonding inside crystals. Experimentally, the traditional method to probe this information is quantitative Convergent Beam Electron Diffraction (CBED). Quantitative CBED or QCEBD is a method which uses dynamic diffraction theory to quantify CBED intensities and to extract information about crystal structure and bonding. The sensitivity of dynamical scattering is leveraged to measure crystal symmetry and crystal structure factors. At its limit, electron structure factors are measured at high accuracy allowing access to chemical bonding information, which corroborate theoretical calculations through multipole model refinements of the experimental charge density. The primary limit to QCBED is the requirement of a non-overlapping convergent beam. This subsequently limits QCBED to crystals with small unit cells which are stable under the focused probe.
Discovering supernova-produced dark matter with directional detectors
Not Available
Coherent elastic neutrino-nucleus scattering with the ν BDX − DRIFT directional detector at next generation neutrino facilities
Not Available
Sensitivity of a low threshold directional detector to CNO-cycle solar neutrinos
Not Available