Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Non-Targeted Direct Infusion Soluble Organic Analysis on a Tarda Meteorite Extract

The differences in chemistry, mineralogy, and structure of chondrites demonstrate thevariations in time/space of their forming regions in the solar nebula. In contrast, the variationof the organic reserves in the solar nebula is unclear. Furthermore, their subsequent evolutionof organic matter on the parent body is still under debate. In a previous study on Tagish Lake(C2 ungrouped) we showed that the primordial soluble organic matter (SOM) could bedistinguished from the parent body's secondary alteration threw mass distribution. This studywill show the Tarda meteorite SOM primordial distribution, using the model from ourprevious study. We discuss its organic reservoirs and secondary alteration effects. We alsocompare the character of the SOM with previously analysed Orgueil (CI). Sample and method: Tarda (fall, 2020) was classified as a C2 ungroup carbonaceouschondrite. Its bulk three oxygen isotope composition is distinct from other chondrite groupsbut similar to CI-chondrite-like and Yamato-type-like [1] values. We analysed themethanol/toluene extract using the high-resolution Orbitrap mass spectrometer at the Institutede Planétologie et d’Astrophysique Grenoble (IPAG) by directly injecting and ionizing theSOM and the solvent using the Heated Electrospray Ionization (HESI) source. After thespectra acquisition, the in-house developed post-processing data analysis tools, Attributor [2],was used. Preliminary Result: The SOM mass distribution of Tarda was well-fitted by the modelinterpreted as the primordial SOM distribution in Tagish lake. This common distributionpattern implies the presence of a common organic reservoir or SOM formation mechanism.Orgueil’s mass spectrum showed a more complex mass-distribution and seemed to be affectedby secondary processes. In contrast to the mass-distribution, SOM’s elemental abundance wasdistinct. The Tarda extract was enriched in S-bearing organic compounds which was incontrast to the Tagish Lake extract consisting of mostly CHNO elements. The presentationwill also discuss the application of our technique to Ryugu or Bennu samples. [1] Meteoriticalbulletin database [2] Orthous-Daunay, F. R. et al. (2019) Geochemical Journal, 53(1), 21-32

J Isa↗

Visually directed pointing as a function of target distance, direction, and available cues.

In pointing at visual targets without sight of the hand, large errors occur. There is a tendency to overreach targets, and this tendency is much greater (about 25 cm) when convergence is the only cue to distance than when there are many cues (2 to 11 cm). Angular errors of up to 10 deg also occur. These tend to be to the side opposite the sighting eye, when the favored hand is used. The variance of the pointing response with convergence alone is reduced by approximately half with the introduction of several spatial cues. These results are interpreted as indicating that, for a target within the reach of the arm and with convergence alone as a cue, the depth signal produced by the visual system corresponds to a greater distance than that produced when many cues are available. The results are also consistent with the hypothesis that perceived direction tends to approximate direction from the sighting eye.

Foley, J. M.↗

System concepts for transmit arrays of parabolic antennas for deep space uplinks

Phased arrays of parabolic antennas are a potentially lower-cost way to provide uplink transmission to distant spacecraft, compared to the 34-m and 70-m antennas now used by the NASA Deep Space Network. A large transmit array could provide very high EIRP when needed for spacecraft emergencies, such as the equivalent of 1 MW radiated from a 70-m antenna. Cost-effectiveness is realized by dividing the array into smaller arrays to provide routine support to many spacecraft simultaneously. The antennas might be as small as 12-m in diameter, with as many as 100 antennas covering an area of 0.5 km to 1 km in extent. Such arrays present significant technical challenges in phase alignment, which must be maintained at close to 1 mm. The concept requires a very stable system with accurately known antenna phase center locations. The system is first calibrated by transmitting from all antennas, and observing the signals at a target located in the far fields of the individual antennas. The antennas are then pointed to the operational targets, with the signal phases and time delays set to reinforce in the target directions. This requires accurate knowledge of the target directions and calculation of the required phases. The system must be phase-stable for all directions and over the time between calibrations, which is desired to be at least one day. In this paper, a system concept is presented, the major error sources are identified, a rough error budget is established, and key elements of the system are discussed. A calibration method is recommended which uses satellites as radar targets. The performance goal is to achieve a combining loss of less than 0.2 dB in good weather, and of less than 1 dB in all but extremely bad weather.

Effective Isotropic Radiated Power (EIRP)↗

Studies of the Ability to Hold the Eye in Eccentric Gaze: Measurements in Normal Subjects with the Head Erect

We studied the ability to hold the eyes in eccentric horizontal or vertical gaze angles in 68 normal humans, age range 19-56. Subjects attempted to sustain visual fixation of a briefly flashed target located 30 in the horizontal plane and 15 in the vertical plane in a dark environment. Conventionally, the ability to hold eccentric gaze is estimated by fitting centripetal eye drifts by exponential curves and calculating the time constant (t(sub c)) of these slow phases of gazeevoked nystagmus. Although the distribution of time-constant measurements (t(sub c)) in our normal subjects was extremely skewed due to occasional test runs that exhibited near-perfect stability (large t(sub c) values), we found that log10(tc) was approximately normally distributed within classes of target direction. Therefore, statistical estimation and inference on the effect of target direction was performed on values of z identical with log10t(sub c). Subjects showed considerable variation in their eyedrift performance over repeated trials; nonetheless, statistically significant differences emerged: values of tc were significantly higher for gaze elicited to targets in the horizontal plane than for the vertical plane (P less than 10(exp -5), suggesting eccentric gazeholding is more stable in the horizontal than in the vertical plane. Furthermore, centrifugal eye drifts were observed in 13.3, 16.0 and 55.6% of cases for horizontal, upgaze and downgaze tests, respectively. Fifth percentile values of the time constant were estimated to be 10.2 sec, 3.3 sec and 3.8 sec for horizontal, upward and downward gaze, respectively. The difference between horizontal and vertical gazeholding may be ascribed to separate components of the velocity position neural integrator for eye movements, and to differences in orbital mechanics. Our statistical method for representing the range of normal eccentric gaze stability can be readily applied in a clinical setting to patients who were exposed to environments that may have modified their central integrators and thus require monitoring. Patients with gaze-evoked nystagmus can be flagged by comparing to the above established normative criteria.

Reschke, Millard F.↗

Exploring the Hot Galactic Halo Using Shadows of High Latitude Clouds

The objective of this proposal was to measure variations in the 1/4 keV emission from the galactic halo, using ROSAT (x-ray astronomy satellite) Position Sensitive Proportional Counters (PSPC) observations toward known enhancements in the absorbing column density along the line-of-sight out of the Galaxy. Target directions were selected to have a low total hydrogen column density but to also show significant gradients in the amount of absorbing material, as traced by Infrared Astronomical Satellite (IRAS) 100 micron emission, on angular scales that would be contained within the PSPC field of view. In addition, we restricted the galactic latitude of the target directions to be greater than 60 degrees or less than -60 degrees in order to enable a cleaner separation of Galactic halo emission from that of the Galactic disk. The observations would also provide a measurement of the brightness of the emission from the Local Bubble.

Juda, M.↗

A General Closed-Form Solution for the Lunar Reconnaissance Orbiter (LRO) Antenna Pointing System

The National Aeronautics and Space Administration s (NASA) Lunar Reconnaissance Orbiter (LRO) launched on June 18, 2009 from the Cape Canaveral Air Force Station aboard an Atlas V launch vehicle into a direct insertion trajectory to the Moon LRO, designed, built, and operated by the NASA Goddard Space Flight Center in Greenbelt, MD, is gathering crucial data on the lunar environment that will help astronauts prepare for long-duration lunar expeditions. During the mission s nominal life of one year its six instruments and one technology demonstrator will find safe landing site, locate potential resources, characterize the radiation environment and test new technology. To date, LRO has been operating well within the bounds of its requirements and has been collecting excellent science data images taken from the LRO Camera Narrow Angle Camera (LROC NAC) of the Apollo landing sites have appeared on cable news networks. A significant amount of information on LRO s science instruments is provided at the LRO mission webpage. LRO s Attitude Control System (ACS), in addition to controlling the orientation of the spacecraft is also responsible for pointing the High Gain Antenna (HGA). A dual-axis (or double-gimbaled) antenna, deployed on a meter-long boom, is required to point at a selected Earth ground station. Due to signal loss over the distance from the Moon to Earth, pointing precision for the antenna system is very tight. Since the HGA has to be deployed in spaceflight, its exact geometry relative to the spacecraft body is uncertain. In addition, thermal distortions and mechanical errors/tolerances must be characterized and removed to realize the greatest gain from the antenna system. These reasons necessitate the need for an in-flight calibration. Once in orbit around the moon, a series of attitude maneuvers was conducted to provide data needed to determine optimal parameters to load onboard, which would account for the environmental and mechanical errors at any antenna orientation. The nominal geometry for the HGA involves an outer gimbal axis that is exactly perpendicular to the inner gimbal axis, and a target direction that is exactly perpendicular to the outer gimbal axis. For this nominal geometry, closed-form solutions of the desired gimbal angles are simple to get for a desired target direction specified in the spacecraft body fame. If the gimbal axes and the antenna boresight are slightly misaligned, the nominal closed-form solution is not sufficiently accurate for computing the gimbal angles needed to point at a target. In this situation, either a general closed-form solution has to be developed for a mechanism with general geometries, or a correction scheme has to be applied to the nominal closed-form solutions. The latter has been adopted for Solar Dynamics Observatory (SDO) as can be seen in Reference 1, and the former has been used for LRO. The advantage of the general closed-form solution is the use of a small number of parameters for the correction of nominal solutions, especially in the regions near singularities. Singularities here refer to cases when the nominal closed-form solutions have two or more solutions. Algorithm complexity, however, is the disadvantage of the general closed-form solution.

Shah, Neerav↗

SAR squint analysis of directional extended targets

Results are presented for multisquint processing of L-band like-polarized (HH) SAR data. Images of agricultural fields were generated by Doppler filtering of SAR signal film, with an angular width and step size of 0.8 deg. The results indicate that field reflectivities may vary by more than 10 dB over a range of less than 1 deg. Implications of observing extremely narrow-beamwidth targets are discussed for platform-pointing and antenna-stability requirements. It is suggested that a multiazimuth Venus-orbiting imaging radar could provide a significant amount of information at a relatively low weight penalty.

Daily, M. I.↗

A flight test method for pilot/aircraft analysis

In high precision flight maneuvres a pilot is a part of a closed loop pilot/aircraft system. The assessment of the flying qualities is highly dependent on the closed loop characteristics related to precision maneuvres like approach, landing, air-to-air tracking, air-to-ground tracking, close formation flying and air-to air refueling of the receiver. The object of a research program at DFVLR is the final flight phase of an air to ground mission. In this flight phase the pilot has to align the aircraft with the target, correct small deviations from the target direction and keep the target in his sights for a specific time period. To investigate the dynamic behavior of the pilot-aircraft system a special ground attack flight test technique with a prolonged tracking maneuvres was developed. By changing the targets during the attack the pilot is forced to react continously on aiming errors in his sights. Thus the closed loop pilot/aircraft system is excited over a wide frequency range of interest, the pilot gets more information about mission oriented aircraft dynamics and suitable flight test data for a pilot/aircraft analysis can be generated.

Koehler, R.↗

Optical profile determining apparatus and associated methods including the use of a plurality of wavelengths in the reference beam and a plurality of wavelengths in a reflective transit beam

An optical profile determining apparatus includes an optical detector and an optical source. The optical source generates a transmit beam including a plurality of wavelengths, and generates a reference beam including the plurality of wavelengths. Optical elements direct the transmit beam to a target, direct a resulting reflected transmit beam back from the target to the optical detector, and combine the reference beam with the reflected transmit beam so that a profile of the target is based upon fringe contrast produced by the plurality of wavelengths in the reference beam and the plurality of wavelengths in the reflected transmit beam.

Montgomery, Robert M.↗

Skylab program earth resources experiment package: Ground truth data for test sites (SL-2)

Field measurements were performed at selected ground sites in order to provide comparative calibration measurements of sensors for the Earth Resources Experiment Package. Specifically, the solar radiation (400 to 1300 namometers) and thermal radiation (8-14 micrometers) were measured. Sites employed for the thermal measurements consisted of warm and cold water lakes. The thermal brightness temperature of the lake water, the temperature and humidity profile above the lake, and near surface meteorology (wind speed, pressure, etc.) were measured near the time of overpass. Sites employed for the solar radiation measurements were two desert type sites. Ground measurements consisted of: (1) direct solar radiation - optical depth; (2) diffuse solar radiation; (3) total solar radiation, (4) target directional (normal) reflectance; (5) target hemispherical reflectance; and (6) near surface meteorology.

Source record↗

Geometric adjustments to account for eye eccentricity in processing horizontal and vertical eye and head movement data

Neglecting the eccentric position of the eyes in the head can lead to erroneous interpretation of ocular motor data, particularly for near targets. We discuss the geometric effects that eye eccentricity has on the processing of target-directed eye and head movement data, and we highlight two approaches to processing and interpreting such data. The first approach involves determining the true position of the target with respect to the location of the eyes in space for evaluating the efficacy of gaze, and it allows calculation of retinal error directly from measured eye, head, and target data. The second approach effectively eliminates eye eccentricity effects by adjusting measured eye movement data to yield equivalent responses relative to a specified reference location (such as the center of head rotation). This latter technique can be used to standardize measured eye movement signals, enabling waveforms collected under different experimental conditions to be directly compared, both with the measured target signals and with each other. Mathematical relationships describing these approaches are presented for horizontal and vertical rotations, for both tangential and circumferential display screens, and efforts are made to describe the sensitivity of parameter variations on the calculated results.

NASA Discipline Neuroscience↗

Human discrimination of visual direction of motion with and without smooth pursuit eye movements

It has long been known that ocular pursuit of a moving target has a major influence on its perceived speed (Aubert, 1886; Fleischl, 1882). However, little is known about the effect of smooth pursuit on the perception of target direction. Here we compare the precision of human visual-direction judgments under two oculomotor conditions (pursuit vs. fixation). We also examine the impact of stimulus duration (200 ms vs. ~800 ms) and absolute direction (cardinal vs. oblique). Our main finding is that direction discrimination thresholds in the fixation and pursuit conditions are indistinguishable. Furthermore, the two oculomotor conditions showed oblique effects of similar magnitudes. These data suggest that the neural direction signals supporting perception are the same with or without pursuit, despite remarkably different retinal stimulation. During fixation, the stimulus information is restricted to large, purely peripheral retinal motion, while during steady-state pursuit, the stimulus information consists of small, unreliable foveal retinal motion and a large efference-copy signal. A parsimonious explanation of our findings is that the signal limiting the precision of direction judgments is a neural estimate of target motion in head-centered (or world-centered) coordinates (i.e., a combined retinal and eye motion signal) as found in the medial superior temporal area (MST), and not simply an estimate of retinal motion as found in the middle temporal area (MT).

Saccades/physiology↗

Designing capture trajectories to unstable periodic orbits around Europa

The hostile environment of third body perturbations restricts a mission designer's ability to find well-behaved reproducible capture trajectories when dealing with limited control authority as is typical with low-thrust missions. The approach outlined in this paper confronts this shortcoming by utilizing dynamical systems theory and an extensive preexisting database of Restricted Three Body Problem (RTBP) periodic orbits. The stable manifolds of unstable periodic orbits are utilized to attract a spacecraft towards Europa. By selecting an appropriate periodic orbit, a mission designer can control important characteristics of the captured state including stability, minimum altitudes, characteristic inclinations, and characteristic radii among others. Several free parameters are optimized in the non-trivial mapping from the RTBP to a more realistic model. Although the ephemeris capture orbit is ballistic by design, low-thrust is used to target the state that leads to the capture orbit, control the spacecraft after arriving on the unstable quasi-periodic orbit, and begin the spiral down towards the science orbit. The approach allows a mission designer to directly target fuel efficient captures at Europa in an ephemeris model. Furthermore, it provides structure and controllability to the design of capture trajectories that reside in a chaotic environment.

low-thrust↗

Progress in Predicting Ionic Cocrystal Formation: The Case of Ammonium Nitrate

In contrast to the mature predictive frameworks applied to neutral cocrystals, ionic cocrystals, those including an ion pair, are difficult to design. Furthermore, they are generally excluded categorically from studies which correlate specific molecular properties to cocrystal formation, leaving the prospective ionic cocrystal engineer with few clear avenues to success. Herein ammonium nitrate, an energetic oxidizing salt, is targeted for cocrystallization in a potential coformer group selected based on likely interactions with the nitrate ion as revealed in the Cambridge Structural Database; six novel ionic cocrystals were discovered. Molecular descriptors previously identified as being related to neutral cocrystal formation were examined across the screening group but showed no relationship with ionic cocrystal formation. High packing coefficient is shown to be a constant among the successful coformers in the set and is utilized to directly target two more successful coformers, bypassing the need for a large screening group.

Andrew J. Bennett↗

Modification of Eccentric Gaze-Holding

Clear vision and accurate localization of objects in the environment are prerequisites for reliable performance of motor tasks. Space flight confronts the crewmember with a stimulus rearrangement that requires adaptation to function effectively with the new requirements of altered spatial orientation and motor coordination. Adaptation and motor learning driven by the effects of cerebellar disorders may share some of the same demands that face our astronauts. One measure of spatial localization shared by the astronauts and those suffering from cerebellar disorders that is easily quantified, and for which a neurobiological substrate has been identified, is the control of the angle of gaze (the "line of sight"). The disturbances of gaze control that have been documented to occur in astronauts and cosmonauts, both in-flight and postflight, can be directly related to changes in the extrinsic gravitational environment and intrinsic proprioceptive mechanisms thus, lending themselves to description by simple non-linear statistical models. Because of the necessity of developing robust normal response populations and normative populations against which abnormal responses can be evaluated, the basic models can be formulated using normal, non-astronaut test subjects and subsequently extended using centrifugation techniques to alter the gravitational and proprioceptive environment of these subjects. Further tests and extensions of the models can be made by studying abnormalities of gaze control in patients with cerebellar disease. A series of investigations were conducted in which a total of 62 subjects were tested to: (1) Define eccentric gaze-holding parameters in a normative population, and (2) explore the effects of linear acceleration on gaze-holding parameters. For these studies gaze-holding was evaluated with the subjects seated upright (the normative values), rolled 45 degrees to both the left and right, or pitched back 30 and 90 degrees. In a separate study the further effects of acceleration on gaze stability was examined during centrifugation (+2 G (sub x) and +2 G (sub z) using a total of 23 subjects. In all of our investigations eccentric gaze-holding was established by having the subjects acquire an eccentric target (+/-30 degrees horizontal, +/- 15 degrees vertical) that was flashed for 750 msec in an otherwise dark room. Subjects were instructed to hold gaze on the remembered position of the flashed target for 20 sec. Immediately following the 20 sec period, subjects were cued to return to the remembered center position and to hold gaze there for an additional 20 sec. Following this 20 sec period the center target was briefly flashed and the subject made any corrective eye movement back to the true center position. Conventionally, the ability to hold eccentric gaze is estimated by fitting the natural log of centripetal eye drifts by linear regression and calculating the time constant (G) of these slow phases of "gaze-evoked nystagmus". However, because our normative subjects sometimes showed essentially no drift (tau (sub c) = m), statistical estimation and inference on the effect of target direction was performed on values of the decay constant theta = 1/(tau (sub c)) which we found was well modeled by a gamma distribution. Subjects showed substantial variance of their eye drifts, which were centrifugal in approximately 20 % of cases, and > 40% for down gaze. Using the ensuing estimated gamma distributions, we were able to conclude that rightward and leftward gaze holding were not significantly different, but that upward gaze holding was significantly worse than downward (p<0.05). We also concluded that vertical gaze holding was significantly worse than horizontal (p<0.05). In the case of left and right roll, we found that both had a similar improvement to horizontal gaze holding (p<0.05), but didn't have a significant effect on vertical gaze holding. For pitch tilts, both tilt angles significantly decreased gaze-holding ility in all directions (p<0.05). Finally, we found that hyper-g centrifugation significantly decreased gaze holding ability in the vertical plane. The main findings of this study are as follows: (1) vertical gaze-holding is less stable than horizontal, (2) gaze-holding to upward targets is less stable than to downward targets, (3) tilt affects gaze holding, and (4) hyper-g affects gaze holding. This difference between horizontal and vertical gaze-holding may be ascribed to separate components of the velocity-to-position neural integrator for eye movements, and to differences in orbital mechanics. The differences between upward and downward gaze-holding may be ascribed to an inherent vertical imbalance in the vestibular system. Because whole body tilt and hyper-g affects gaze-holding, it is implied that the otolith organs have direct connections to the neural integrator and further studies of astronaut gaze-holding are warranted. Our statistical method for representing the range of normal eccentric gaze stability can be readily applied to normals who maybe exposed to environments which may modify the central integrator and require monitoring, and to evaluate patients with gaze-evoked nystagmus by comparing to the above established normative criteria.

Reschke, M. F.↗

Radionuclide measurements by accelerator mass spectrometry at Arizona

Over the past years, Tandem Accelerator Mass Spectrometry (TAMS) has become established as an important method for radionuclide analysis. In the Arizona system the accelerator is operated at a thermal voltage of 1.8MV for C-14 analysis, and 1.6 to 2MV for Be-10. Samples are inserted into a cesium sputter ion source in solid form. Negative ions sputtered from the target are accelerated to about 25kV, and the injection magnet selects ions of a particular mass. Ions of the 3+ charge state, having an energy of about 9MeV are selected by an electrostatic deflector, surviving ions pass through two magnets, where only ions of the desired mass-energy product are selected. The final detector is a combination ionization chamber to measure energy loss (and hence, Z), and a silicon surface-barrier detector which measures residual energy. After counting the trace iosotope for a fixed time, the injected ions are switched to the major isotope used for normalization. These ions are deflected into a Faraday cup after the first high-energy magnet. Repeated measurements of the isotope ratio of both sample and standards results in a measurement of the concentration of the radionuclide. Recent improvements in sample preparation for C-14 make preparation of high-beam current graphite targets directly from CO2 feasible. Except for some measurements of standards and backgrounds for Be-10 measurements to date have been on C-14. Although most results have been in archaeology and quaternary geology, studies have been expanded to include cosmogenic C-14 in meteorites. The data obtained so far tend to confirm the antiquity of Antarctic meteorites from the Allan Hills site. Data on three samples of Yamato meteorites gave terrestrial ages of between about 3 and 22 thousand years.

Jull, A. J. T.↗

A controllability-stabilizability result for the NASA-IEEE Spacecraft Control Laboratory Experiment (SCOLE) configuration

A nonlinear distributed parameter model for the NASA-Institute of Electrical and Electronics Engineers' Spacecraft Control Laboratory Experiment (SCOLE) configuration is considered. A linear feedback control law is proposed that points the line of sight of the antenna to any given target direction and at the same time stabilizes the oscillations of the entire flexible configuration.

Araya, Roberto↗