Search NASA⌕ Search

SEARCH · Search NASA

Results for “directional cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Directional Cooling-Induced Fracturing: Directional Cooling Data Under True-Triaxial Stress State

Data includes Directional Cooling-Induced Fracturing (DCIF) testing data using westerly granite blocks. This submission includes data from two samples of westerly granite, lab sample 7 and 8. Files contain stress, temperature and acoustic emission data acquired during polyaxial, laboratory testing of westerly granite blocks for each sample. FILES: .tradb -- files containing acoustic emission waveforms; sqlite3 database .pridb -- files containing basic acoustic emission information (no waveforms); sqlite3 database .geom -- geometry of the AE sensor network (ASCII)

15 GEOTHERMAL ENERGY↗

A transmissive concentrator photovoltaic module with cells directly cooled by silicone oil for solar cogeneration systems

Hybrid concentrator photovoltaic-thermal systems can cogenerate electricity and heat by beam-splitting incoming concentrated light onto photovoltaic cells and a thermal receiver to increase total conversion efficiency and potentially reduce system cost. To demonstrate this, we have designed and prototyped a transmissive spectrum-splitting concentrator photovoltaic module that maximizes solar energy conversion by utilizing the entire solar spectrum. Visible light is collected using infrared-transmissive triple-junction photovoltaic cells to achieve an in-band module efficiency of 43.3% for light of wavelength λ < 873 nm, while 44.2% of out-of-band light with λ > 873 nm is transmitted through for collection by a thermal receiver. During testing on a dual-axis tracked parabolic concentrator dish at up to 166 suns, cell temperatures were maintained at 119 °C or below via a novel active cooling method. This cooling system strictly flows silicone oil directly across both sides of the cells, without inhibiting optical transmission, as verified through experimentation and simulation. The module was validated outdoors for 572 sun·hrs, and achieved a maximum thermal receiver temperature of 180 °C. 86.1% of incident solar power is collected at 166 suns average concentration collectively among the electrical, cooling, and thermal receiver subsystems. The remaining 13.9% is lost to mirror reflectivity, dish shadowing, receiver reflection, and thermal losses. The ability to directly cool the cells with an inert silicone oil offers the potential for reduced system cost relative to previous transmissive hybrid concentrator photovoltaic-thermal systems, including microfluidic-cooled designs. This solar cogeneration capability is valuable in a wide range of commercial and industrial applications.

14 SOLAR ENERGY↗

Turboexpander for Direct Cooling in Hydrogen Vehicle Fueling Infrastructure

Hydrogen fuel cell electric vehicles (FCEVs) have been identified as one of a few options for zero carbon emissions transportation. A major advantage of FCEVs is that they can fuel quickly and follow a familiar fueling behavior to hydrocarbon-fueled vehicles. Whether light duty or heavy duty, the goal for a hydrogen dispenser is to fuel a vehicle in the same amount of time as the fossil fuel equivalent. When hydrogen is dispensed into the vehicle storage system, however, the temperature rises due to the Joule-Thomson effect and the heat of compression. Typically, vehicles store the compressed hydrogen in composite overwrapped pressure vessels that have a polymer liner with an operational temperature limit of 85°C. This temperature limit can be exceeded during fast fueling if hydrogen is not precooled. Precooling allows for a dispenser to fuel a vehicle at a faster flow rate by preventing the storage tank on the vehicle from overheating. Fueling protocols and requirements are presented in SAE J2601 Fueling Protocols for Light Duty Gaseous Hydrogen Surface Vehicles [1]. A heavy-duty equivalent is under development with similar requirements for precooling. Currently, conventional precooling for light-duty vehicle refueling uses a heat exchanger and chiller to cool the hydrogen gas to -40°C before entering the vehicle. The precooling system represents a significant part of the station capital and operating costs, so if the cost of the precooling system can be reduced by improving its efficiency, the overall station capital and operating cost can be reduced. In this project, National Renewable Energy Laboratory (NREL) and Sandia National Laboratories (SNL) researchers teamed up to investigate the turboexpander precooling application. A turboexpander is a device that places a turbine in a flow path where a pressure differential can be attained. This expansion device will extract work and lower the temperature of the fluid as the pressure reduces. While initial calculations based on established principles showed potential for a turboexpander to generate cooled gas, much work needs to be done to prove the concept. Turboexpanders typically work best under steady state conditions, while the dispenser is a very dynamic flow system. Dynamic turboexpander systems have been proven, such as a turbocharger on a gasoline vehicle. The inlet pressure at a dispenser is also much higher than any other known turboexpander system but should behave similarly to higher density fluids at lower pressures. Having both performed initial calculations, NREL and SNL researchers teamed up to investigate the turboexpander precooling application further. A project was soon built around the idea with SNL performing system modeling using previously proven capabilities and NREL performing hardware characterization with established station capabilities. Creare LLC was contracted as the turbomachinery expert to design and build the concept device. Part way through the project, however, contracting issues with the funding partner caused the project to terminate early before building and characterizing the concept device. While the project could not continue, many key findings were already learned. This paper is a summary of those findings.

08 HYDROGEN↗

Directional Cooling-Induced Fracturing Westerly Granite Test Results

Directional Cooling-Induced Fracturing (DCIF) experiments were conducted on a short, cylindrical sample of Westerly granite (diameter = 4 inches, height ~ 2 inches). Liquid nitrogen was poured in a copper cup attached to the top of the sample, and the resulting acoustic emissions (AEs) and temperature changes on the surface of the sample were monitored. The obtained AEs were used to determine the microcracking source locations and amplitude, and the associated moment tensors. Included in this submission is an animation of the AEs, a graphic displaying the temperature changes, and the measured data.

15 GEOTHERMAL ENERGY↗

DCIF (Directional Cooling-Induced Fracturing) Westerly Granite AE Borehole Damage Effect Test (Task 3-0)

Directional Cooling-Induced Fracturing (DCIF) experiments were conducted on three rectangular Westerly granite blocks (width=depth=4.0", height=2.0") which were preheated to 200, 400, and 600 degree C to induce damage (microcracks) with varying degrees. Liquid nitrogen was poured in a small, 1"-diameter copper cup attached to the top of the sample, and the resulting acoustic emissions (AEs) and temperature changes on the surface of the sample were monitored. The experiments were conducted under one selected biaxial stress (5.8MPa). The obtained AEs were used to determine the microcracking source locations and amplitude, and the associated moment tensors. The onset time of the AEs was correlated with the cooling temperature, which was used to show that the temperature at the onset of microcracking is not affected significantly by the preexisting damage, compared to the impact of the stress in the sample. Included in this submission are the animations of the AE locations and graphics displaying the measured temperature-AE activity changes for samples with different degrees of microcrack damage.

15 GEOTHERMAL ENERGY↗

Cloud‐Surface Coupling Alters the Morning Transition From Stable to Unstable Boundary Layer

Abstract Due to surface heating, the morning boundary layer transits from stable to neutral or convective conditions, exerting critical influences on low tropospheric thermodynamics. Low clouds closely interact with the boundary layer development, yet their interactions bear considerable uncertainties. Our study reveals that cloud‐surface coupling alters the morning transition from stable to unstable boundary layer and thus notably affects the diurnal variation of the boundary layer. Specifically, due to the reduction in surface fluxes, decoupled clouds can delay the process of eroding nocturnal inversion by 0.8‐hr and even prevent the transition of the boundary layer from happening for 12% of decoupled cases, keeping the boundary layer in a stable state during the noontime. On the other hand, when clouds are coupled with the surface, cloud‐top radiative cooling can directly cool the upper boundary layer to facilitate sub‐cloud convection, leading to an unstable boundary layer in the earlier morning.

54 ENVIRONMENTAL SCIENCES↗

A hierarchical gray-box dynamic modeling methodology for direct-expansion cooling systems to support control stability analysis; Méthodologie de modélisation dynamique hiérarchique de type boîte grise pour les systèmes de refroidissement à détente directe afin de soutenir l'analyse de stabilité de la commande

In this paper, a gray-box dynamic modeling approach for direct-expansion cooling systems is presented. The overall approach incorporates a multi-stage training procedure that consists of 1) identification of component sub-models from quasi-steady-state performance data, 2) system model integration with estimation of refrigerant charge and 3) fine tuning of thermal capacitances of the evaporator and condenser to capture the system dynamic responses. Compared to traditional physics-based models, the proposed modeling approach has advantages including reduced engineering efforts in the model development phase, improved computational efficiency and enhanced prediction accuracy. The modeling method was validated using a 3-ton variable-speed heat pump and proved to be capable of accurately predicting the system transient behaviors over a wide range of operating conditions. The established dynamic model was then applied for control stability analysis, with a specific goal of determining a proper control execution time step. The case study results showed that the stable control execution time step could change significantly, from 3 sec to 19 sec, as the operating conditions and control settings vary, and a proper selection of the execution time step is critical to ensure stable and reliable operations.

42 ENGINEERING↗

Direct Dry Cooling System Spreadsheet Model for sCO 2

The attached cost and performance spreadsheet model is for a direct dry cooling system, one of four cooling system models developed for use in optimizing indirectly-heated supercritical CO 2 (sCO 2 ) power cycles. Running the model requires that the user has REFPROP version 9 or below installed, as well as the Microsoft Excel REFPROP Add-In. Upon opening, use Excel’s Edit Links feature to link to the user’s installed REFPROP.xla or REFPROP.xlam file. For the spreadsheet model compatible with REFPROP version 10 and above, contact Nathan Weiland at nathan.weiland@netl.doe.gov. Technical documentation for the model can be found here: https://www.netl.doe.gov/energy-analysis/details?id=3199.

30 DIRECT ENERGY CONVERSION↗

High-resolution infrared spectroscopy of jet cooled CH 2 Br radicals: The symmetric CH stretch manifold and absence of nuclear spin cooling

Direct laser absorption of a slit supersonic discharge expansion provides the first high-resolution spectroscopic results on the symmetric CH stretch excitation (ν 1 ) of the bromomethyl (CH 2 Br) radical in the ground electronic state. Narrowband (<1 MHz) mid-infrared radiation is produced by difference-frequency generation of two visible laser beams, with the open shell halohydrocarbon radical generated by electron dissociative attachment of CH 2 Br 2 in a discharge and rapidly cooled to T rot = 18 ± 1 K in the subsequent slit-jet supersonic expansion. A rovibrational structure in the radical spectrum is fully resolved, as well as additional splittings due to spin-rotation effects and 79 Br/ 81 Br isotopologues in natural abundance. Spectroscopic constants and band origins are determined by fitting the transition frequencies to a non-rigid Watson Hamiltonian, yielding results consistent with a vibrationally averaged planar radical and an unpaired electron in the out-of-plane p π orbital. Additionally, extensive satellite band structure from a vibrational hot band is observed and analyzed. The hot band data is compared to CFOUR/VPT2 (CCSD(T)cc-pVQZ) ab initio anharmonic predictions of the vibration rotation alpha matrix, which permits unambiguous assignment to CH 2 symmetric-stretch excitation built on the singly excited CH 2 out-of-plane bending mode (ν 1 + ν 4 ← ν 4 ). Longitudinal cooling of the Doppler width in the slit-jet expansion geometry also reveals partially resolved hyperfine structure on transitions out of the lowest angular momentum states in excellent agreement with predictions based on microwave studies. High level ab initio MOLPRO calculations [CCSD(T)-f12b/VnZ-f12 (n = 3, 4, CBS)] are also performed with explicitly correlated f12 electron methods for the out-of-plane CH 2 bending mode over the halogen series CH 2 X (X = F, Cl, Br, I), which clearly reveals a non-planar geometry for X = F (with a ΔE ≈ 0.3 kcal/mol barrier) and yet planar equilibrium geometries for X = Cl, Br, and I. Finally, a detailed Boltzmann analysis of the transition intensities provides support for negligible collisional equilibration of the entangled H atom nuclear spin states on the few hundred microsecond time scale and high collision densities of a slit supersonic expansion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparative Analysis of Direct and Indirect Cooling of Wide-Bandgap Power Modules and Performance Enhancement of Jet Impingement-Based Direct Substrate Cooling

With the development of high-power and high-torque machines, requirements for high-power density electronics are increasing. Thermal management of such systems requires high heat extraction. Conventional air cooling based heat sinks and cold plate based liquid cooling have their own benefits for various applications but has limitations for high power density applications. The current study explores a jet impingement based direct substrate cooling system that was implemented for a SiC based direct bonded Cu substrate for various power losses. Numerical comparison between jet impingement cooling and conventional horizontal/indirect cooling (pin fin heat sink and genetic algorithm-optimized heat sink) showed that the area weighted average of the heat transfer coefficient (HTC) is high for both horizontal cooling designs, and the local HTC is higher for jet impingement. Design iterations were undertaken to resolve the bottleneck of this cooling system. Increasing the number of nozzles helped to cover more area at the direct bonded Cu bottom plate, which drops the chip temperature considerably. With a constant flow rate, increasing the number of nozzles would decrease local jet velocity, which reduces the heat extraction by jet impingement. This issue can be addressed by reducing the diameter of nozzle but doing so results in a high pressure drop where the design constraint is 2 psi. A flared nozzle design is proposed, which has a higher spreading angle of the jet that increases the flow coverage and reduces the pressure drop of the coolant loop.

Barua, Himel↗

A prototype cooling blanket for mitigating occupant overheating risk in a hot indoor environment: Modeling and assessments

Conventional ways of cooling a room or an entire house for occupant thermal comfort during summer consume a significant amount of energy and are vulnerable to overheating risk during power outages that lead to loss of cooling system operations. This study investigates a low-power cooling blanket, as a Personal Cooling System (PCS), that covers the upper human body for direct cooling during a five-day heat wave in a single-family house. A modeling framework is developed for evaluating the thermal and energy performance of the cooling blanket, which builds upon the co-simulation of three models: a house energy model, a personal thermal comfort model, and a cooling blanket model. Simulation results show that under the power outage scenario, the cooling blanket can greatly reduce the occupant heat stress with a reduction of daily hours of exceedance (discomfort hours defined as TSV>2) by up to 17.2 h (a 95.3 % improvement from the baseline power outage without the blanket). The cooling blanket, equipped with an innovative electrocaloric heat pump (COP as high as 10.1) consumes 6.31 W and can be operated by a portable battery for several days. The cooling blanket consumes only 0.28 % of the electricity of a central air-conditioning system running to provide cooling for the whole house during the five-day heatwave period. The findings justify further research of electrocaloric wearable PCS as low-power effective cooling to ensure thermal survivability of occupants during extreme indoor environments.

Electrocaloric heat pump↗

Feasibility of Process Intensification of Water-Gas Shift Reaction Using a Microreactor with Integrated Cooling

Hydrogen is an increasingly attractive low-carbon energy carrier for a variety of stationary and mobile applications. The water-gas shift (WGS) reaction is a key processing step used for large-scale hydrogen production via the steam methane reforming process. However, the thermodynamics and kinetics of the reaction are such that standard two-stage adiabatic reactors used in these systems are large, increasing catalyst volume and cost. To intensify the process and realize the economical distributed production of hydrogen, adiabatic WGS microreactors with integrated cooling directly regulate the reaction temperature via integrated coolant channels to promote higher conversion within a smaller reactor volume. This study investigates the conversion efficiency of a single WGS microchannel operating under such cooling conditions. A COMSOL Multiphysics model is developed and validated with isothermal experimental data from the literature. The model is then used to evaluate improvements in conversion efficiency when the reaction is cooled via a specified wall temperature profile. Lastly, the model is modified to include cooling channels with a secondary fluid that can practically achieve a similar conversion profile as the specified wall temperature profile previously applied. Initial results show that reactor conversion can be significantly increased by the inclusion of appropriate cooling and that there is a potential for the recovery of energy from the reaction stream that can be used for other applications within the overall process.

energy recovery↗

Reaching the equilibrium state of the frustrated triangular Ising magnet Ca 3 Co 2 O 6

Ca 3 Co 2 O 6 is a frustrated magnet consisting of a triangular arrangement of chains of Ising spins. It shows regular magnetization steps versus magnetic field every 1.2 T that are metastable with very slow dynamics. This has puzzled the community for many years and given rise to numerous potential theories. Here we approach the problem by seeking the elusive magnetic equilibrium state at T=2 K. To this end, we explore two approaches: (1) bypassing the slow dynamics produced by changing fields by instead field-cooling directly to the target temperature and (2) quantum annealing in transverse magnetic fields. While we observe no measurable effect of the quantum annealing in fields up to 7 T, which is likely due to the large Ising anisotropy of Co spins in this material, we find that for the field cooling in longitudinal fields we achieve the predicted equilibrium 1/3 magnetization. We perform Monte Carlo simulations of the ground state phase diagram and we also simulate the quantum annealing process and find good agreement between experiment and theory. Thus we present an investigation of the elusive ground state properties of the canonical frustrated triangular system Ca 3 Co 2 O 6 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗