Search NASA⌕ Search

SEARCH · Search NASA

Results for “directional discharge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Radioisotope Analysis of Wastewater from Livermore Site Retention Tanks by Gel Laboratory Gross Alpha, Gross Beta and Tritium Sampling Method

Lawrence Livermore National Laboratory discharged approximately 4.4% of the City of Livermore’s total wastewater in 2022 (LLNL’s Annual Site Environmental Report, Chapter 5, 2022). This volume includes wastewater from Sandia National Laboratories (SNL) and some process wastewater from Site 300. Due to the high volume and constituents of the discharge, LLNL works alongside the City of Livermore under permit #1250, requiring wastewater generated to be monitored and sampled in accordance with permit limits. Process wastewater, from buildings with the highest risk to sewer, is collected by wastewater retention tanks throughout the Livermore Site and sampled prior to discharge. Domestic wastewater directly discharges to sanitary sewer. To maintain permit requirements and ensure proper wastewater discharge practices, an internal wastewater audit was conducted during the summer of 2023. Current wastewater practices, regulatory knowledge and risk management across various Livermore Site buildings were evaluated. Workspaces connected to a wastewater retention tank and sanitary sewer drains were major focus areas. Data collected from walk-throughs prompted further evaluation as many practices were reported to be done based on historical usage. A table of concerns was created to showcase reasons for auditing and proceeding action. An analysis of current and historical retention tank usage throughout LLNL Livermore Site buildings with radioisotope results over a 5-year period from 2019 to 2024, was done to assess building trends and any significant changes throughout the 5-year period. Analytes evaluated were Gross Alpha, Gross Beta and Tritium (GABT) of eleven buildings at the Livermore Site, posing the highest risk to sanitary sewer for radioisotopes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Negative Medium-Voltage Direct Current Discharges in Air under Simulated Sub-Atmospheric Pressures for All-Electric Aircraft

The increase in the global temperature due to greenhouse gas emissions is a major concern to the world. To achieve the goal of zero emissions by 2050 in the USA the practical realization of all-electric vehicles, particularly all-electric aircraft (AEA), is important. For the design of electrical power systems (EPSs) in all-electric aircraft, a bipolar medium-voltage direct current (MVDC) system of ±5 kV is being investigated. However, several challenges manifest when using such voltages in a low-pressure environment. One of the main challenges is the partial discharge (PD) behavior of the insulation. It is important to study the PD behavior of the insulation by simulating the aviation environment in the lab. This work aimed to study the partial discharge behavior of air under a negative DC voltage in a needle-to-plane electrode geometry by simulating the aviation pressures in the lab. The partial discharge inception voltage (PDIV) and the breakdown voltage (BDV) show an obvious pressure-dependent variation. Regression analysis was performed to better understand the relationship between the PDIV and pressures. Plots were drawn for the average discharge current at each voltage step until breakdown. This paper’s findings can provide valuable insight into the design of EPS for an AEA. To the best of our knowledge, such a study has not been carried out to date.

air discharge↗

Partial discharge testing under direct voltage conditions

DC partial discharge (PD) (corona) testing is performed using a multichannel analyzer for pulse storing, and data is collected during increase of voltage and at quiescent voltage levels. Thus high voltage ceramic disk capacitors were evaluated by obtaining PD data interspersed during an accelerated life test. Increased PD activity was found early in samples that later failed catastrophically. By this technique, trends of insulation behavior are revealed sensitively and nondestructively in high voltage dc components.

Bever, R. S.↗

Coherent High-Frequency Axial Oscillations in a Partially Magnetized Direct Current Magnetron Discharge

High-frequency oscillations are observed in a neon plasma of a direct current magnetron discharge. At low discharge currents, we see highly coherent 60 MHz fluctuations. Above a distinct current threshold, secondary 5–10 MHz fluctuations emerge in addition to turbulent fluctuations in the 60–100 MHz range. The oscillations in the total discharge current suggest axial wave propagation. A lower-hybrid wave theory is invoked to model the high-frequency oscillations. Here, we attribute the low-frequency modes to a turbulence-driven inverse cascade process, as suggested by recent simulations.

33 ADVANCED PROPULSION SYSTEMS↗

Soil Desiccation Treatability Testing at BC Waste Disposal Cribs

During Hanford’s production period, low-level waste products generated from chemical processing of uranium fuel rods were discharged directly to the ground through a system of cribs and trenches located in the 200-BC-1 Operable Unit (OU). The site consists of 6 cribs and 20 trenches that received more than 117,000 m3 of radioactive liquid waste discharged to the soil. These unlined infiltration galleries held volumes of liquid waste while it seeped into the ground, with the understanding that the 100 m (330 ft) thick vadose zone in the area would effectively capture the effluent and prevent groundwater impacts. A conceptual model showing the operation of cribs and trenches is shown in Figure 1. Data show effluent from the 26 cribs and trenches containing about 410 curies of Technetium-99 (Tc-99) is primarily located between 30 m and 70 m (98 ft and 230 ft) depth (Corbin et al., 2005; Ward et al., 2004). Despite no evidence indicating that the contamination has reached the groundwater at BC cribs and trenches, the mobility of Tc-99 had been demonstrated in laboratory tests and was recognized as a threat to groundwater at the site. Using data from numerical models, laboratory analyses, field investigations, and information on historical discharges, the EPA and Ecology identified Tc-99 and U contamination of the vadose zone as a remediation priority. The U.S. DOE was notified by EPA and Ecology regarding risks associated with Tc-99 contamination in a letter requesting development of a strategy for improved methods to understand the nature and extent of vadose zone contamination, specifically Tc-99, and to develop remedial options for addressing such contamination. To develop the appropriate technology for characterizing, remediating, and monitoring the deep vadose zone Tc-99 contamination, the U.S. DOE worked with the EPA and Ecology to create a Treatability Test Plan under a Remedial Investigation/Feasibility Study (RI/FS) for the Hanford 200 Areas. Under this RI/FS, it was determined that a treatability test for soil desiccation should be carried out as it was identified as a promising in-situ treatment technology for mitigating risks posed by Tc-99 contamination to the groundwater table. The BC Cribs and Trenches site was identified as a representative site for Tc-99 and U contamination and selected for the soil desiccation treatability test. In this chapter, we summarize the overlying regulatory framework of RI/FS and treatability tests and illustrate how development and experimentation supported the evaluation of selected remedies. We briefly discuss the RI/FS for the 200 Areas of the Hanford Site and focus on the soil desiccation treatability testing performed at the BC cribs and trenches site under the Deep Vadose Zone Treatability Test Plan for the Hanford Central Plateau (DVZ-TT). The DVZ-TT is one component of the remedial investigation/feasibility study for the Hanford 200 Areas and represents the underlying regulatory framework that drives site operations towards records of decision and site closure.

Mangel, Adam R.↗

Charge-exchange losses of beam ions in MAST Upgrade: experiments and modelling

Dedicated experiments were performed on MAST Upgrade to study beam-ion losses caused by charge exchange (CX) with edge neutrals. The fuelling was switched from the high-field side to the low-field side mid-discharge. Direct measurements suggest a strong increase in the neutral density around the plasma and a decrease in the beam-ion density, which is qualitatively explained by CX losses. Measurements by a resistive bolometer have suggested particle bombardment during neutral beam injection, providing a unique opportunity to separate CX from other loss mechanisms. To verify and quantify CX losses, the orbit-following code ASCOT, which accounts both for CX neutralization and reionization, was used to simulate beam-particle power loads on the bolometer. Simulations reproduce measured bolometer power loads during high-field-side fuelling, verifying CX losses of approximately 10% of the off-axis beam power. Toroidally symmetric simulations overestimate power loads on the bolometer during low-field-side fuelling, which is explained by toroidal asymmetry in the neutral density distribution, as is demonstrated by toroidally asymmetric simulations. Results suggest significantly higher CX losses during low-field-side fuelling, up to about 50% of off-axis beam power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Small, two-stage, partial-admission turbine

The Rocketdyne Orbital Transfer Vehicle (OTV) cryogenic, rocket engine system, high pressure, liquid hydrogen turbopump was designed with a two-stage, partial-admission axial turbine. The turbine is basically two single-stage, partial-admission, subsonic impulse stages designed so the kinetic energy leaving the first-stage rotor is discharged directly into the second-stage nozzle at nominal operation to minimize staging losses. Very little data were available in the literature for this type of turbine design. Therefore, it was decided to test a full-size model of the turbine design using ambient-temperature gaseous nitrogen as the working fluid. The tester design features a variable orientation second-stage nozzle to determine the optimum circumferential location for highest performance. The tester also features the capability to vary the nozzle arcs of admission and incorporates quartz windows to study the flowfield upstream of the second-stage nozzle using a laser velocimeter. The test operations will probe the efficiency and flow characteristics for three arcs of admission and the effects of second-stage nozzle circumferential orientations over wide ranges of speed and pressure ratios as well as the interstage pressure distributions.

Sutton, R. F.↗

Performance Characteristics of Plane-Wall Two-Dimensional Diffusers

Experiments have been made at Stanford University to determine the performance characteristics of plane-wall, two-dimensional diffusers which were so proportioned as to insure reasonable approximation of two-dimensional flow. All of the diffusers had identical entrance cross sections and discharged directly into a large plenum chamber; the test program included wide variations of divergence angle and length. During all tests a dynamic pressure of 60 pounds per square foOt was maintained at the diffuser entrance and the boundary layer there was thin and fully turbulent. The most interesting flow characteristics observed were the occasional appearance of steady, unseparated, asymmetric flow - which was correlated with the boundary-layer coalescence - and the rapid deterioration of flow steadiness - which occurred as soon as the divergence angle for maximum static pressure recovery was exceeded. Pressure efficiency was found to be controlled almost exclusively by divergence angle, whereas static pressure recovery was markedly influenced by area ratio (or length) as well as divergence angle. Volumetric efficiency. diminished as area ratio increased, and at a greater rate with small lengths than with large ones. Large values of the static-pressure-recovery coefficient were attained only with long diffusers of large area ratio; under these conditions pressure efficiency was high and. volumetric efficiency low. Auxiliary tests with asymmetric diffusers demonstrated that longitudinal pressure gradient, rather than wall divergence angle, controlled flow separation. Others showed that the addition of even a short exit duct of uniform section augmented pressure recovery. Finally, it was found that the installation of a thin, central, longitudinal partition suppressed flow separation in short diffusers and thereby improved pressure recovery

Reid, Elliott G↗

Pulsars Magnetospheres

Current density determines the plasma flow regime. Cascades are non-stationary. ALWAYS. All flow regimes look different: multiple components (?) Return current regions should have particle accelerating zones in the outer magnetosphere: y-ray pulsars (?) Plasma oscillations in discharges: direct radio emission (?)

Timokhin, Andrey↗

Growth of metal nanoparticles in hydrocarbon atmosphere of arc discharge

A direct current (DC) arc discharge is a widely used method for large-scale production of metal nanoparticles, core–shell particles, and carbon nanotubes. Here, the growth of iron nanoparticles is explored in a modified DC arc discharge. Iron particles are produced by the evaporation of an anode, made from low-carbon steel. Methane admixture into argon gas serves as a carbon source. Electron microscopy and elemental analysis suggest that methane and/or products of its decomposition adhere to iron clusters forming a carbon shell, which inhibits iron particle growth until its full encapsulation, at which point the iron core growth is ceased. Experimental observations are explained using an aerosol growth model. The results demonstrate the path to manipulate metal particle size in a hydrocarbon arc environment.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Hysteresis between gas breakdown and plasma discharge

In direct-current (DC) discharge, it is well known that hysteresis is observed between the Townsend (gas breakdown) and glow regimes. Forward and backward voltage sweep is performed using a one-dimensional particle-in-cell Monte Carlo collision (PIC-MCC) model considering a ballast resistor. When increasing the applied voltage after reaching the breakdown voltage (V b ), transition from Townsend to glow discharges is observed. When decreasing the applied voltage from the glow regime, the discharge voltage (V d ) between the anode–cathode gap can be smaller than the breakdown voltage, resulting in a hysteresis, which is consistent with experimental observations. Next, the PIC-MCC model is used to investigate the self-sustaining voltage (V s ) in the presence of finite initial plasma densities between the anode and cathode gap. It is observed that the self-sustaining voltage coincides with the discharge voltage obtained from the backward voltage sweep. In addition, the self-sustaining voltage decreases with increased initial plasma density and saturates above a certain initial plasma density, which indicates a change in plasma resistivity. The decrease in self-sustaining voltage is associated with the electron heat loss at the anode for the low pd (rarefied) regime. In the high pd (collisional) regime, the ion energy loss toward the cathode due to the cathode fall and the inelastic collision loss of electrons in the bulk discharge balance out. Finally, it is demonstrated that the self-sustaining voltage collapses to a singular value, despite the presence of a initial plasma, for microgaps when field emission is dominant, which is also consistent with experimental observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of ionization waves on dust chain formation in a DC discharge

An interesting aspect of complex plasma is its ability to self-organize into a variety of structural configurations and undergo transitions between these states. A striking phenomenon is the isotropic-to-string transition observed in electrorheological complex plasma under the influence of a symmetric ion wake field. Such transitions have been investigated using the Plasma Kristall-4 (PK-4) microgravity laboratory on the International Space Station. Recent experiments and numerical simulations have shown that, under PK-4-relevant discharge conditions, the seemingly homogeneous direct current discharge column is highly inhomogeneous, with large axial electric field oscillations associated with ionization waves occurring on microsecond time scales. here, a multi-scale numerical model of the dust–plasma interactions is employed to investigate the role of the electric field in the charge of individual dust grains, the ion wake field and the order of string-like structures. Results are compared with those for dust strings formed in similar conditions in the PK-4 experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3D Radio Frequency Mapping and Polarization Observations Show Lightning Flashes Were Ignited by Cosmic‐Ray Showers

Previous 2D radio frequency interferometric observations showed that lightning is commonly started with a positive fast discharge (+FD) before a normal negative leader continues from the origin of the +FD to the ensuing lightning flash. However, the inception and development of the +FD cannot be convincingly explained by existing discharge theories. With our new 3D broadband interferometric mapping and polarization system, we observed that the +FD was sometimes followed by an even faster and more extensive negative discharge (−FD) that propagated backward and overshoot the origin by a few hundred meters, as reported by an earlier 2D study. Surprisingly, the signal polarization, which measures the orientation of the discharge current, systematically slanted from the discharge propagation direction and rotated between the two opposite discharges, showing the +FD and −FD were driven by other storm-independent factors in addition to the storm electric field, or otherwise all would align in the same direction. Assuming a cosmic-ray shower (CRS) piercing through the cloud immediately before the +FD/−FD discharge, we found that their path is consistent with a pre-ionized path by the CRS, and the polarizations for the two opposite discharges are consistent with the respective deflected trajectories of high-energy positrons and electrons in the geomagnetic and an electric field. We further analyzed the more commonly observed +FD and showed that it is consistent with the CRS interpretation, suggesting these flashes in thunderstorms were ignited by cosmic-ray showers.

58 GEOSCIENCES↗

A direct-measurement technique for estimating discharge-chamber lifetime

The use of short-term measurement techniques for predicting the wearout of ion thrusters resulting from sputter-erosion damage is investigated. The laminar-thin-film technique is found to provide high precision erosion-rate data, although the erosion rates are generally substantially higher than those found during long-term erosion tests, so that the results must be interpreted in a relative sense. A technique for obtaining absolute measurements is developed using a masked-substrate arrangement. This new technique provides a means for estimating the lifetimes of critical discharge-chamber components based on direct measurements of sputter-erosion depths obtained during short-duration (approximately 1 hr) tests. Results obtained using the direct-measurement technique are shown to agree with sputter-erosion depths calculated for the plasma conditions of the test. The direct-measurement approach is found to be applicable to both mercury and argon discharge-plasma environments and will be useful for estimating the lifetimes of inert gas and extended performance mercury ion thrusters currently under development.

Beattie, J. R.↗