Search NASA⌕ Search

SEARCH · Search NASA

Results for “directional discharge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Partial discharge testing under direct voltage conditions

DC partial discharge (PD) (corona) testing is performed using a multichannel analyzer for pulse storing, and data is collected during increase of voltage and at quiescent voltage levels. Thus high voltage ceramic disk capacitors were evaluated by obtaining PD data interspersed during an accelerated life test. Increased PD activity was found early in samples that later failed catastrophically. By this technique, trends of insulation behavior are revealed sensitively and nondestructively in high voltage dc components.

Bever, R. S.↗

Small, two-stage, partial-admission turbine

The Rocketdyne Orbital Transfer Vehicle (OTV) cryogenic, rocket engine system, high pressure, liquid hydrogen turbopump was designed with a two-stage, partial-admission axial turbine. The turbine is basically two single-stage, partial-admission, subsonic impulse stages designed so the kinetic energy leaving the first-stage rotor is discharged directly into the second-stage nozzle at nominal operation to minimize staging losses. Very little data were available in the literature for this type of turbine design. Therefore, it was decided to test a full-size model of the turbine design using ambient-temperature gaseous nitrogen as the working fluid. The tester design features a variable orientation second-stage nozzle to determine the optimum circumferential location for highest performance. The tester also features the capability to vary the nozzle arcs of admission and incorporates quartz windows to study the flowfield upstream of the second-stage nozzle using a laser velocimeter. The test operations will probe the efficiency and flow characteristics for three arcs of admission and the effects of second-stage nozzle circumferential orientations over wide ranges of speed and pressure ratios as well as the interstage pressure distributions.

Sutton, R. F.↗

Performance Characteristics of Plane-Wall Two-Dimensional Diffusers

Experiments have been made at Stanford University to determine the performance characteristics of plane-wall, two-dimensional diffusers which were so proportioned as to insure reasonable approximation of two-dimensional flow. All of the diffusers had identical entrance cross sections and discharged directly into a large plenum chamber; the test program included wide variations of divergence angle and length. During all tests a dynamic pressure of 60 pounds per square foOt was maintained at the diffuser entrance and the boundary layer there was thin and fully turbulent. The most interesting flow characteristics observed were the occasional appearance of steady, unseparated, asymmetric flow - which was correlated with the boundary-layer coalescence - and the rapid deterioration of flow steadiness - which occurred as soon as the divergence angle for maximum static pressure recovery was exceeded. Pressure efficiency was found to be controlled almost exclusively by divergence angle, whereas static pressure recovery was markedly influenced by area ratio (or length) as well as divergence angle. Volumetric efficiency. diminished as area ratio increased, and at a greater rate with small lengths than with large ones. Large values of the static-pressure-recovery coefficient were attained only with long diffusers of large area ratio; under these conditions pressure efficiency was high and. volumetric efficiency low. Auxiliary tests with asymmetric diffusers demonstrated that longitudinal pressure gradient, rather than wall divergence angle, controlled flow separation. Others showed that the addition of even a short exit duct of uniform section augmented pressure recovery. Finally, it was found that the installation of a thin, central, longitudinal partition suppressed flow separation in short diffusers and thereby improved pressure recovery

Reid, Elliott G↗

Pulsars Magnetospheres

Current density determines the plasma flow regime. Cascades are non-stationary. ALWAYS. All flow regimes look different: multiple components (?) Return current regions should have particle accelerating zones in the outer magnetosphere: y-ray pulsars (?) Plasma oscillations in discharges: direct radio emission (?)

Timokhin, Andrey↗

A direct-measurement technique for estimating discharge-chamber lifetime

The use of short-term measurement techniques for predicting the wearout of ion thrusters resulting from sputter-erosion damage is investigated. The laminar-thin-film technique is found to provide high precision erosion-rate data, although the erosion rates are generally substantially higher than those found during long-term erosion tests, so that the results must be interpreted in a relative sense. A technique for obtaining absolute measurements is developed using a masked-substrate arrangement. This new technique provides a means for estimating the lifetimes of critical discharge-chamber components based on direct measurements of sputter-erosion depths obtained during short-duration (approximately 1 hr) tests. Results obtained using the direct-measurement technique are shown to agree with sputter-erosion depths calculated for the plasma conditions of the test. The direct-measurement approach is found to be applicable to both mercury and argon discharge-plasma environments and will be useful for estimating the lifetimes of inert gas and extended performance mercury ion thrusters currently under development.

Beattie, J. R.↗

Hypersonic Magneto-Fluid-Dynamic Compression in Cylindrical Inlet

Hypersonic magneto-fluid-dynamic interaction has been successfully performed as a virtual leading-edge strake and a virtual cowl of a cylindrical inlet. In a side-by-side experimental and computational study, the magnitude of the induced compression was found to be depended on configuration and electrode placement. To better understand the interacting phenomenon the present investigation is focused on a direct current discharge at the leading edge of a cylindrical inlet for which validating experimental data is available. The present computational result is obtained by solving the magneto-fluid-dynamics equations at the low magnetic Reynolds number limit and using a nonequilibrium weakly ionized gas model based on the drift-diffusion theory. The numerical simulation provides a detailed description of the intriguing physics. After validation with experimental measurements, the computed results further quantify the effectiveness of a magnet-fluid-dynamic compression for a hypersonic cylindrical inlet. At a minuscule power input to a direct current surface discharge of 8.14 watts per square centimeter of electrode area produces an additional compression of 6.7 percent for a constant cross-section cylindrical inlet.

Shang, Joseph S.↗

Economical synthesis of potassium superoxide

High-frequency discharge in oxygen can be used to prepare superoxides of alkali and alkaline-earth metals. Since no direct-current discharge at the electrodes is present, no sputtering can contaminate the product, hence a high conversion efficiency.

Bell, A. T.↗

Nondestructive Evaluation of the J-2X Direct Metal Laser Sintered Gas Generator Discharge Duct

The J-2X program at NASA's Marshall Space Flight Center (MSFC) procured a direct metal laser sintered (DMLS) gas generator discharge duct from Pratt & Whitney Rocketdyne and Morris Technologies for a test program that would evaluate the material properties and durability of the duct in an engine-like environment. DMLS technology was pursued as a manufacturing alternative to traditional techniques, which used off nominal practices to manufacture the gas generator duct's 180 degree turn geometry. MSFC's Nondestructive Evaluation (NDE) Team performed radiographic, ultrasonic, computed tomographic, and fluorescent penetrant examinations of the duct. Results from the NDE examinations reveal some shallow porosity but no major defects in the as-manufactured material. NDE examinations were also performed after hot-fire testing the gas generator duct and yielded similar results pre and post-test and showed no flaw growth or development.

Esther, Elizabeth A.↗

The Characterization of a DC Glow Discharge in a Tripped Hypersonic Boundary Layer

A direct current glow discharge plasma was generated on a canonical 2.75° half-angle wedge test article. Experiments were conducted in the Texas A&M University Actively Controlled Expansion tunnel at 𝑀 = 5.7 and 𝑅𝑒 = 6 × 10 6 /m. The effect of Reynolds number, polarity, and upstream perturbation were all independently studied via imaging, power measurements, and optical emission spectroscopy (OES). These measurements are the first to be conducted in a tripped hypersonic boundary layer and allow a deeper understanding of the electrohydrodynamics. The plasma, formally characterized as a normal glow discharge, had negligible Joule and cathode heating effects on the boundary layer. Analogously, the installation of trips upstream of the electrodes changed only the appearance of the plasma, creating periodic streaks corresponding to the wakes and vortices produced by each trip but not altering the power across the electrodes. The plasma power peaked at 47 W, which OES revealed was sufficient to generate NO in the positive column and negative glow.

Casey J. Broslawski↗

The Characterization of a DC Glow Discharge in a Tripped Hypersonic Boundary Layer

A direct current glow discharge plasma was generated on a canonical 2.75° half-angle wedge test article. Experiments were conducted in the Texas A&M University Actively Controlled Expansion tunnel at 𝑀 = 5.7 and 𝑅𝑒 = 6 × 10 6 /m. The effect of Reynolds number, polarity, and upstream perturbation were all independently studied via imaging, power measurements, and optical emission spectroscopy (OES). These measurements are the first to be conducted in a tripped hypersonic boundary layer and allow a deeper understanding of the electrohydrodynamics. The plasma, formally characterized as a normal glow discharge, had negligible Joule and cathode heating effects on the boundary layer. Analogously, the installation of trips upstream of the electrodes changed only the appearance of the plasma, creating periodic streaks corresponding to the wakes and vortices produced by each trip but not altering the power across the electrodes. The plasma power peaked at 47 W, which OES revealed was sufficient to generate NO in the positive column and negative glow.

Casey Broslawski↗