Search NASA⌕ Search

SEARCH · Search NASA

Results for “discharging method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Zero-Cost Closed-Loop Discharging Method for Modular Multilevel Converter Submodules Without External Circuits

A novel submodule capacitor discharging control strategy is introduced and implemented for modular multilevel converters (MMCs). By sequentially controlling the arm currents of anMMC,all submodule capacitors are discharged rapidly through internal arm resistors without additional devices and circuits, resulting in improved performance and reduced cost. A closed-loop control method is explored for the effectiveness of the new control strategy.Acomparison study is evaluated between the proposed method and the traditional methods using bleeding resistors, auxiliary resistors, and load resistors. Confirmed by the simulation and experiment, the proposed method has the maximum benefits including zero hardware cost, fast discharging time, and negligible load current impact

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Firearm discharge location systems and methods

Firearm discharge location systems and methods are described. According to one aspect, a firearm discharge location system includes a plurality of microphones spaced from one another, timing circuitry configured to generate a plurality of asynchronous timing references, wherein data capture operations with respect to the microphones of a first pair are synchronized with one another using a first of the timing references and data capture operations with respect to the microphones of a second pair are synchronized with one another using a second of the timing references, and processing circuitry configured to use outputs of the first and second pairs of the microphones to identify a location of a firearm discharge.

Gonzalez, Eric G.↗

Comparison of experimental and computational methods for discharge measurements from tidal wetlands

This short communication describes the use and comparison of three methods used to calculate the flow discharge from a tidal wetland stream. The techniques presented are a) bottom-mounted ADCP deployments, b) vessel-mounted ADCP transects, and c) a volume inundation spatial model that relies on a high-resolution LiDAR dataset and time-series of water surface elevation data. The relative agreement between these three methods is used to build confidence in the application of these techniques to the challenge of deducing flow discharge from tidal wetlands.

54 ENVIRONMENTAL SCIENCES↗

Post-Wildfire Peak Discharge Prediction Methods in Northern New Mexico

Recent changes in climate have resulted in a decrease in precipitation and snowpack amounts and increased temperatures in the western United States. As the climate warms, there are also changes to runoff amounts and water availability. Drier and warmer conditions coupled with forest management practices have led to an increase in the frequency and size of forest fires. The 2000 Cerro Grande fire in Los Alamos, New Mexico burned over 43,000 acres and 200 structures. Eleven years later, the Las Conchas fire burned over 156,000 acres and 100 structures, including areas previously burned in 2000, and was considered the largest fire in New Mexico’s history. Both fires burned ponderosa, juniper, piñon and mixed conifer forests, resulting in dramatic decreases in vegetation, changes to surface soils, and alterations to the hydrologic cycle (decreased evapotranspiration, decreased infiltration, increased runoff volume and peak discharge, and decreased time to peak discharge) in surrounding watersheds. The frequency of large, intense “mega-fires” are predicted to increase, thus there is a potential for more post-fire flood damage and more surface water resources to be altered due to water quality issues.

54 ENVIRONMENTAL SCIENCES↗

Experimental Investigation of Steel-Borne Acoustic Pulses for Fault Pinpointing in Pipe-Type Cable Systems: A Scaled-Down Model Approach

Pipe-type cable systems, including high-pressure fluid-filled (HPFF) and high-pressure gas-filled cables, are widely used for underground high-voltage transmission. These systems consist of insulated conductor cables within steel pipes, filled with pressurized fluids or gases for insulation and cooling. Despite their reliability, faults can occur due to insulation degradation, thermal expansion, and environmental factors. As many circuits exceed their 40-year design life, efficient fault localization becomes crucial. Fault location involves prelocation and pinpointing. Therefore, a novel pinpointing approach for pipe-type cable systems is proposed, utilizing accelerometers mounted on a steel pipe to capture fault-induced acoustic signals and employing the time difference of arrival method to accurately pinpoint the location of the fault. The experimental investigations utilized a scaled-down HPFF pipe-type cable system setup, featuring a carbon steel pipe, high-frequency accelerometers, and both mechanical and capacitive discharge methods for generating acoustic pulses. The tests evaluated the propagation velocity, attenuation, and pinpointing accuracy with the pipe in various embedment conditions. The experimental results demonstrated accurate fault pinpointing in the centimeter range, even when the pipe was fully embedded, with the acoustic pulse velocities aligning closely with the theoretical values. These experimental investigation findings highlight the potential of this novel acoustic pinpointing technique to improve fault localization in underground systems, enhance grid reliability, and reduce outage duration. Further research is recommended to validate this approach in full-scale systems.

Moutassem, Zaki↗

Non-invasive method of gas discharge detector recovery after degradation in intense radiation fields

A method of noninvasive recovery of gas-discharge detectors degraded due to operation in intense radiation fields is described. The plasma-chemical reactions are the basis of the presented techniques; these reactions take place during the detector training in a gas discharge of special recovering gas mixtures. The results of recovery of operating parameters for proportional chambers and counters are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A network analysis of the long-term quality of life and mental distress of COVID-19 survivors 1 year after hospital discharge

Objectives COVID-19 survivors suffer from persistent mental distress and impaired quality of life (QOL) after recovery from the infection. However, the symptom-symptom interaction between these psychological variables remained unexplored. The present study aimed to determine the symptom network of mental distress (depression, anxiety, sleep disturbance, fatigue, and post-traumatic stress disorder) and their association with QOL among 535 COVID-19 survivors 1 year after hospital discharge. Methods 9-item Patient Health Questionnaire, 7-item Generalized Anxiety Disorder Scale, Chalder fatigue scale, Impact of Event Scale-Revised, Pittsburgh Sleep Quality Index, and 36-Item Short-Form Health Survey were applied to measure depression, anxiety, fatigue, PTSD, sleep disturbances, and QOL, respectively. Two networks were estimated using Gaussian graphical model. Network 1 consisted of mental symptoms to determine the central and bridge symptoms. Network 2 additionally included QOL to determine which mental symptoms were mostly related to QOL. Results 60% of the COVID-19 survivors experienced mental distress 1 year after hospital discharge. Uncontrollable and excessive worry, psychomotor symptoms, intrusion, and daytime dysfunction were the most central symptoms. Daytime dysfunction and fatigue (especially mental fatigue and loss of energy) served as the bridge symptoms across the mental distress network and exhibited the most substantial association with QOL. Conclusion Our study demonstrated several key symptoms that played a vital role in mental distress and QOL among COVID-19 survivors. Prompt screening and targeted interventions for these symptoms might hold great promise in preventing mental distress and improving QOL in COVID-19 survivors.

Peng, Pu↗

Preparation of Nanosized Tungsten and Tungsten Oxide Powders

Nanopowder tungsten oxide and metallic tungsten are obtained via pyrolysis of ammonium metatungstate. Two methods are used for the synthesis of tungsten oxide: the use of a fibrous matrix and pyrolysis of aerosol particles. Tungsten oxide particles are formed during the pyrolysis in air. Metallic tungsten nanoparticles are obtained via subsequent thermal reduction of tungsten oxide in hydrogen. The structure and morphology of the samples are studied with X-ray diffraction and scanning electron microscopy. Tungsten nanopowders with average sizes from 7 to 30 nm are obtained depending on synthesis temperature. The electrochemical characteristics of electrodes coated with tungsten nanoparticles are studied with cyclic voltammetry, impedance spectroscopy, and galvanostatic charge–discharge methods. An electrode with W nanoparticles exhibited a specific low-frequency capacitance of about 90 F/g due to thin tungsten oxide film on the surface of tungsten nanoparticles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Influence of Bi addition on the property of Ag-Bi nano-composite coatings

Silver (Ag) coatings have been widely used in many industry areas due to their excellent conductivity. However, wider applications of Ag coatings have been hindered by their poor mechanical properties. In this research, to improve the mechanical performance, Ag-Bi nano-composite coatings were prepared by a novel ionic co-discharge method. A systematic study of the microstructure, mechanical properties, electrical conductivity and antibacterial behavior of the resulting coating was performed. The results indicated that after adding an appropriate amount of Bi containing solution into the Ag plating solution, Ag-Bi nanoparticles were in-situ formed and distributed uniformly throughout the coating matrix, resulting in a significant improvement in the mechanical properties. The hardness of Ag-Bi coating was increased by 60% compared to that of the pure Ag coating. The corrosion resistance of Ag-Bi coatings was also enhanced. The Ag-Bi coatings prepared in the current study will find a broader application in electronics, jewelry, aerospace and other industries.

36 MATERIALS SCIENCE↗

Mechanical and Tribological Behavior of Multiwalled Carbon Nanotubes-Reinforced AA7075 Composites Prepared by Powder Metallurgy and Hot Extrusion

Carbon nanotubes (CNT) are synthesized using arc discharge method in an open air. Various amounts of carbon nanotubes-reinforced AA7075 composites are prepared by powder metallurgy route and then hot extrusion at 450 °C. Hot-extruded composites are characterized, and mechanical properties are measured. Dry sliding wear properties of hot-extruded samples were evaluated using a pin-on-disk method for various loads (5-20 N) at room temperature and for various temperatures (100-400 °C) at the applied load 10 N as a function of CNT amount. Grain size of the composites is decreased compared with Al alloy matrix. Transmission electron microscopy of the composites revealed that the CNT are uniformly distributed in the composites. Mechanical properties of the hot-extruded composites are enhanced with an increase in CNT content. The wear performance is improved with an increased CNT amount, but decreases with an increase in the applied load and temperature as well. The wear damage is mild at lower applied loads and temperatures, whereas the damage is severe at 400 °C. The wear mechanism was plowing in the initial stages which is transformed to severe sliding and chipping with increasing load and temperature. The enhanced wear behavior of composites is attributed to self-lubricating nature of carbon nanotubes.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Impact of Li Addition in Al-Rich Alloys on Hydrogen Production in Water

In this study, three types of aluminum alloys (Al-Li, Al-Ga-In-Sn and Al-Li-Ga-In-Sn alloys) were prepared via vacuum arc melting technology. The microstructures of the alloys were examined by x-ray diffraction (XRD), scanning electron microscopy (SEM) and energy-dispersive spectroscopy (EDX). The water discharge method was used to evaluate the water–aluminum reaction. The results show that the Al-Li alloy is inert in aqueous ambience, whereas the Al-Ga-In-Sn alloy and Al-Li-Ga-In-Sn alloy rapidly react with water. Meanwhile, the Li addition hinders the aluminum–water reaction mainly due to the formation of AlLi and Li{sub 5}Sn{sub 2} intermetallic compounds, which causes a lower H{sub 2} generation rate and a lower H{sub 2} yield of the Al-Li-Ga-In-Sn alloy than those of the Al-Ga-In-Sn alloy.

36 MATERIALS SCIENCE↗

A diuranium carbide cluster stabilized inside a C 80 fullerene cage

Unsupported non-bridged uranium–carbon double bonds have long been sought after in actinide chemistry as fundamental synthetic targets in the study of actinide-ligand multiple bonding. Here we report that, utilizing I h (7)-C 80 fullerenes as nanocontainers, a diuranium carbide cluster, U=C=U, has been encapsulated and stabilized in the form of UCU@I h (7)-C 80 . This endohedral fullerene was prepared utilizing the Krätschmer–Huffman arc discharge method, and was then co-crystallized with nickel(II) octaethylporphyrin (Ni II -OEP) to produce UCU@I h (7)-C 80 ·[Ni II -OEP] as single crystals. X-ray diffraction analysis reveals a cage-stabilized, carbide-bridged, bent UCU cluster with unexpectedly short uranium–carbon distances (2.03 Å) indicative of covalent U=C double-bond character. The quantum-chemical results suggest that both U atoms in the UCU unit have formal oxidation state of +5. The structural features of UCU@I h (7)-C 80 and the covalent nature of the U(f 1 )=C double bonds were further affirmed through various spectroscopic and theoretical analyses.

36 MATERIALS SCIENCE↗

Novel Q-Carbon Anodes for Sodium-Ion Batteries

The lack of a standard anode for sodium-ion batteries (SIBs) has greatly hindered their applications. Herein, we show that a novel phase of carbon, namely Q-carbon, is an effective anode material for sodium-ion batteries. The Q-carbon, which is a metastable phase of carbon consisting of about 80% sp 3 - and 20% sp 2 -bonded carbon, is synthesized by nonequilibrium pulsed laser annealing and arc-discharge methods. Two types of Q-carbons, Q1 and Q2, were evaluated as anode material for SIBs. Q1 had a slow quench and was used as the control, whereas Q2 was Q-carbon with a rapid quenching. Q1 exhibits a high initial columbic efficiency of 81% and a low-capacity retention of less than 60%, whereas Q2 has a low initial columbic efficiency of 58% and a high-capacity retention of 81%. Q2 exhibits a stable capacity of 168 mAh·g −1 at a cycling rate of C/3 (124 mA·g −1 ), which is comparable to other hard carbon anodes reported in the literature. This unique synthesis method opens a pathway for the further tuning of Q-carbon with higher trapping/charging of Na + ions in improved SIBs.

25 ENERGY STORAGE↗

Apparatus and methods of detecting transient discharge modes and/or closed loop control of pulsed systems and method employing same

A system and method for differentiating between different modes of pulsed electrical discharges via of an amplitude to time (ATC) conversion circuit is described. A bipolar ATC circuit is used to add together the positive and negative portions of an attenuated and filtered signal derived either from the voltage or current of a pulse. Alternatively, a unipolar ATC circuit may be employed. The resulting processed signal is compared against a reference voltage to generate an output signal that is active for the amount of time that the processed signal exceeds the reference voltage. Discharge mode is determined based on three factors: did a pulse occur, if a pulse occurred when did the pulse start relative to the original pulse event, and what is the duty cycle of the pulse. Subsequent pulse generated may be controlled accordingly.

Fitzpatrick, Joseph F.↗

Electrostatic charge buildup and electrostatic discharge monitoring system and method

A system for monitoring electrostatic charge buildup and electrostatic discharge (ESD) remotely comprises a plurality of electrostatic charge measurement units and a data acquisition device. Each electrostatic charge measurement unit includes a primary charge plate, a static sensor device, a secondary charge plate, and a shielded cable. The primary charge plate is positioned proximal to an object. The static sensor device includes an input sensor at which an electric voltage is measured and outputs an electronic signal whose level varies according to the measured electric voltage. The secondary charge plate is positioned in proximity to the input sensor of the static sensor device. The shielded cable includes an inner conductor electrically connected to the primary charge plate and the secondary charge plate and an outer conductor electrically connected to electrical ground. The data acquisition device receives the electronic signal from the static sensor device of each electrostatic charge measurement unit.

Schantz, Eric T.↗

Systems and related methods for determining self-discharge currents and internal shorts in energy storage cells

Systems and methods for determining self-discharge currents in an energy storage cell and detecting internal shorts are disclosed. A system includes a DC voltage source configured to provide a constant test voltage selected to be less than an open-circuit voltage of an energy storage cell to the energy storage cell. The system also includes a current measuring device operably coupled between the DC voltage source and the energy storage cell, and control circuitry operably coupled to the current measuring device. A method includes applying the constant test voltage, and measuring the test current flowing between the DC voltage source and the energy storage cell until after the test current switches from a negative current to a positive current. The method also includes determining a self-discharge current of the energy storage cell by analyzing the measured test current with computational models that capture physical processes tied to the test methods.

25 ENERGY STORAGE↗

Glow Discharge Boronization and Real-Time Boronization Using an Impurity Powder Dropper in LHD

In the Large Helical Device (LHD), boronization is utilized for wall conditioning, employing two distinct methods: glow discharge using diborane gas and the injection of boron powder into the plasma via an impurity powder dropper (IPD). Glow discharge boronization is conducted after maintenance when the vacuum vessel is exposed to air and just before the start of an experimental campaign. In contrast, real-time boronization using the IPD is performed during discharges. The distribution of boron on plasma-facing components was assessed through long-term material probes in the case of glow discharge and through numerical simulations for the IPD method. Results indicated non-uniform boron distributions in both cases. The impact of these boronization techniques on impurity levels and the lifetime of their effects were also examined. Both methods effectively reduced oxygen and iron in the plasma, with the iron impurities originating from the first wall. For glow discharge boronization, the reduction in oxygen levels persisted until the end of the experimental campaign, whereas the reduction in iron levels only lasted a few days. In the case of boron injection during long pulse discharges exceeding 200 s, the suppression of oxygen and iron was observed. The effect on iron quickly diminished within several seconds after the injection ended, whereas the effect on oxygen lasted more than 100 s. The difference in the lifetimes of the boronization effects is further discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface Water: Stage, Temperature and Discharge, Teller Road Mile Marker 27, Seward Peninsula, Alaska, 2016-2021

Surface water data were collected at one location in the Teller Mile 27 (TL_MM27) Research Basin Site, Seward Peninsula (N64 43' 35.29649", W165 56' 48.42823"). The site was installed and measurements collected from April 2016 to September 2021. During the pandemic, a combination of environmental factors (both animals and climate) led to a gap in the data record from late 2019 to June 2021. Station restarted in June 2021 with the same basin outlet and instrumentation type. These data are being collected to better understand the hydrology of this research basin. The data could also be used as supporting measurements for other research and modeling activities. Stream stage and water temperature are measured every 10 minutes. Discharge in the stream is also measured every site visit using one of two different methods. Most discharge measurements in this data set use the classic US Geological Survey (USGS) style wading rod to measure water velocity at multiple points (every 5 or 10 centimeters) across a known cross-section (https://pubs.usgs.gov/tm/tm3-a8/pdf/tm3-a8.pdf). The second method is the salt-slug mass diffusion method (https://www.uvm.edu/bwrl/lab_docs/protocols/2005_Moore_Slug_salt_dilution_gauging_volumetric_method_Streamline.pdf). Combining the continuous data record with the discrete observations, a stage-discharge relationship was developed. Dataset contains 14 *.csv files including a data dictionary and file-level metadata plus one user guide *.pdf file. DATASET UPDATE: The 2016-2019 data were published in 2019. Data collection continued through 2021 and were added to the dataset in 2025. There were no changes to the 2016-2019 data. Data files now have all years for a measurement combined into one file; whereas before, each measurement and each year had an individual file. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗