Search NASA⌕ Search

SEARCH · Search NASA

Results for “disinfection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Surface Water Disinfection Byproducts and Organic Matter Characterization Data Associated with: “Disinfection byproducts formed during drinking water treatment reveal an export control point for dissolved organic matter in a subalpine headwater stream”

This dataset is associated with the publication “Disinfection byproducts formed during drinking water treatment reveal an export control point for dissolved organic matter in a subalpine headwater stream” published in Water Research X (Leonard et al. 2022; https://doi.org/10.1016/j.wroa.2022.100144). The associated study analyzed temporal trends from the Town of Crested Butte water treatment facility and synoptic sampling at Coal Creek in Crested Butte, Colorado, US. This work demonstrates how drinking water quality archives combined with synoptic sampling and targeted analyses can be used to identify and understand export control points for dissolved organic matter. This dataset is comprised of one main data folder containing (1) file-level metadata; (2) data dictionary; (3) metadata and international geo-sample number (IGSN) mapping file; (4) dissolved organic carbon (DOC), ultraviolet absorbance at 254 nanometers (UV254), total nitrogen (TN), and specific ultraviolet absorbance (SUVA) data; (5) disinfection bioproduct formation potential (DBP-FP) data; (6) readme; (7) methods codes; (8) water collection protocol; (9) folder of high resolution characterization of organic matter via 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory); and (10) folder of excitation emissions matrix (EEM) spectra. The FTICR folder contains a file of DOC (measured as non-purgeable organic carbon; NPOC) used for FTICR sample preparation. The FTICR folder also contains three subfolders: one subfolder containing the raw .xml data files, one containing the processed data, and the other containing instructions for using Formularity (https://omics.pnl.gov/software/formularity) and an R script to process the data based on the user's specific needs. All files are .csv, .pdf, .dat, .R, .ref, or .xml

54 ENVIRONMENTAL SCIENCES↗

A direct viable count method for the enumeration of attached bacteria and assessment of biofilm disinfection

This report describes the adaptation of an in situ direct viable count (in situ DVC) method in biofilm disinfection studies. The results obtained with this technique were compared to two other enumeration methods, the plate count (PC) and conventional direct viable count (c-DVC). An environmental isolate (Klebsiella pneumoniae Kp1) was used to form biofilms on stainless steel coupons in a stirred batch reactor. The in situ DVC method was applied to directly assess the viability of bacteria in biofilms without disturbing the integrity of the interfacial community. As additional advantages, the results were observed after 4 h instead of the 24 h incubation time required for colony formation and total cell numbers that remained on the substratum were enumerated. Chlorine and monochloramine were used to determine the susceptibilities of attached and planktonic bacteria to disinfection treatment using this novel analytical approach. The planktonic cells in the reactor showed no significant change in susceptibility to disinfectants during the period of biofilm formation. In addition, the attached cells did not reveal any more resistance to disinfection than planktonic cells. The disinfection studies of young biofilms indicated that 0.25 mg/l free chlorine (at pH 7.2) and 1 mg/l monochloramine (at pH 9.0) have comparable disinfection efficiencies at 25 degrees C. Although being a weaker disinfectant, monochloramine was more effective in removing attached bacteria from the substratum than free chlorine. The in situ DVC method always showed at least one log higher viable cell densities than the PC method, suggesting that the in situ DVC method is more efficient in the enumeration of biofilm bacteria. The results also indicated that the in situ DVC method can provide more accurate information regarding the cell numbers and viability of bacteria within biofilms following disinfection.

NASA Discipline Number 04-10↗

Durability of Disposable N95 Mask Material When Exposed to Improvised Ozone Gas Disinfection

The principle finding of this report is that both commercial and a novel material used for N95 mask filters can endure many cycles of disinfection by ozone gas (20 ppm for 30 minutes) without detectable degradation or loss of filtration efficiency. N95 masks and surgical masks (hereafter referred to as masks) typically use a filtration material fabricated from meltblown polypropylene. To achieve maximum filtration efficiency while maintaining a reasonable pressure drop, these nonwoven fabrics are also electrostatically charged (corona discharge is the most common method used), to maximize attraction and capture of aerosols and solid particulates. Under normal circumstances, the reuse of masks is generally discouraged, but in times of crisis has become a necessity, making disinfection after each use a necessity. To be acceptable, any disinfection procedure must cause minimal degradation to the performance of the filter material. Possible performance degradation mechanisms include mechanical damage, loss of electrostatic charge, or both. One of the most practical and direct ways to measure combined mechanical and electrostatic integrity, and the subsequent ability to reuse mask filter material, is by the direct measurement of filtration efficiency. In this paper, we report that small numbers of disinfection cycles at reasonable virucidal doses of ozone do not significantly degrade the filtration efficiency of meltblown polypropylene filter material. By comparison, laundering quickly results in a significant loss of filtration efficiency and requires subsequent recharging to restore the electrostatic charge and filtration efficiency. A common assumption among biomedical scientists that ozone is far too destructive for this application. However, these direct measurements show that mask materials, specifically the filtration material, can withstand dozens of ozone disinfection cycles without any measurable degradation of filtration efficiency, nor any visible discoloration or loss of fiber integrity. The data are clear: when subjected to a virucidal dose of ozone for a much longer duration than is required for viral inactivation, there was no degradation of N95 filtration efficiency. The specific dosages of ozone needed for ~99% viral inactivation are thought to be at least 10 ppm for up to 30 minutes based upon an extensive literature review, but to standardize our testing, we consider a dose of 20 ppm for 30 minutes to be a reasonable and conservatively high ozone disinfection cycle. Finally, the material tested in this study withstood dosages of up to 200 ppm for 90 minutes, or alternatively 20 ppm for up to 36 hours, without detectable degradation, and further testing suggests that up to 30 or more disinfection cycles (at 20 ppm for 30 minutes) would result in less than a 5% loss of filtration efficiency. This report does not address the effect of ozone cycling on other mask components, such as elastics.

60 APPLIED LIFE SCIENCES↗

Extended use of face masks during the COVID-19 pandemic - Thermal conditioning and spray-on surface disinfection

The current COVID-19 pandemic has resulted in globally constrained supplies for face masks and personal protective equipment (PPE). Production capacity is limited in many countries and the future course of the pandemic will likely continue with shortages for high quality masks and PPE in the foreseeable future. Therefore, expectations are that mask reuse, extended wear and similar approaches will enhance the availability of personal protective measures. Repeated thermal disinfection could be an important option and likely easier implemented in some situations, at least on the small scale, than UV illumination, irradiation or hydrogen peroxide vapor exposure. In this paper, an overview on thermal responses and ongoing filtration performance of multiple face mask types is provided. Most masks have adequate material properties to survive a few cycles (i.e. 30 min disinfection steps) of thermal exposure in the 75°C regime. Some are more easily affected, as seen by the fusing of plastic liner or warping, given that preferred conditioning temperatures are near the softening point for some of the plastics and fibers used in these masks. Hence adequate temperature control is equally important. As guidance, disinfectants sprayed via dilute solutions maintain a surface presence over extended time at 25 and 37°C. Some spray-on alcohol-based solutions containing disinfectants were gently applied to the top surface of masks. Neither moderate thermal aging (less than 24 h at 80 and 95°C) nor gentle application of surface disinfectant sprays resulted in measurable loss of mask filter performance. Subject to bio-medical concurrence (additional checks for virus kill efficiency) and the use of low risk non-toxic disinfectants, such strategies, either individually or combined, by offering additional anti-viral properties or short term refreshing, may complement reuse options of professional masks or the now ubiquitous custom-made face masks with their often unknown filtration effectiveness.

36 MATERIALS SCIENCE↗

Effect of simethicone on the bactericidal efficacy of a high-level disinfectant

Introduction.Simethicone is an over-the-counter product that is frequently used by clinicians during endoscopic procedures to reduce foaming and improve visualization. Published studies have found simethicone residue on endoscopes after cleaning and disinfecting the devices as per the manufacturer’s instructions. Some literature suggests that simethicone residue may reduce disinfection efficacy and increase the risk of patient infections. Gap Statement.However, there appears to be a lack of direct evidence in the literature to either disprove this or correlate simethicone presence with an increased microbial risk. Aim: Research was conducted to evaluate thein vitroimpact of simethicone on disinfection efficacy. Methodology.Bacteria were grown in a microtitre plate assay in the presence of a range of simethicone concentrations and then treated with a disinfectant. Bacterial growth was assessed by spotting each microtitre well onto an agar plate. Results.The results demonstrated that, under the conditions tested, simethicone did not reduce the efficacy of Cidex ortho-phthalaldehyde disinfectant, which demonstrated at least a 6-log unit reduction in bacterial viability. Additional experiments showed that direct exposure to 66 mg ml −1 of simethicone reduced bacterial viability. Conclusion.These results indicate that simethicone may not reduce the bactericidal efficacy of disinfectant during reprocessing, under certain conditions.

Microbiology↗

Influence of Application Method on Disinfectant Byproduct Formation during Indoor Bleach Cleaning: A Case Study on Phenol Chlorination

Modern disinfection methods increasingly utilize droplet dispersal as a means of delivering disinfectant within an indoor space. Such an application produces droplets over wide size ranges, some of which may remain airborne for minutes to hours while serving as small reaction environments. We report here the formation of chlorophenolic disinfection byproducts (DBPs) during the injection of bleach microdroplets into an environmental chamber. These reactions within airborne microdroplets are driven by phenol dissolution and availability, and the observed DBPs span multiple generations of chlorination chemistry. DBPs representing successive chlorine addition to the phenol ring are initially observed (mono-, di-, and trichlorophenol), followed by DBPs that lack aromaticity (2,6-dichlorobenzoquinone and 2,4,4,6-tetrachloro-2,5-cyclohexadienone, among others). Chlorophenolic DBPs have not been reported during prior work examining indoor bleach cleaning and we attribute their observation in this work to the dispersal of disinfectant microdroplets rather than traditional mopping or wiping with a bulk aqueous solution on an indoor surface. Airborne microdroplets represent unique reaction and volatilization environments and unique exposure pathways to DBPs, via direct compound inhalation as well as the inhalation of DBP-containing microdroplets. The observed DBPs (particularly 2,6-dichlorobenzoquinone) have previously been linked to adverse health effects in humans through either direct toxicity or as precursors to other DBPs with adverse health effects. In conclusion, these measurements suggest that more work is needed to understand potential DBP formation and human exposure within a variety of indoor environments where disinfection techniques that generate airborne microdroplets are used.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-Situ Electrochemical Generation and Utilization of Hydrogen Peroxide for Disinfection

Disinfection needs to meet personal hygiene requirements at the International Space Station (ISS) is currently accomplished through the use of pre-packaged, disposable, wetted wipes, which represent an appreciable carry-along mass and disposal burden. However, as human missions travel further into the solar system the availability of resources to resupply will be diminished. Therefore, next-generation system should use onboard utilities to create on demand disinfectants, thereby reducing the dependence on earth-based supplies and further eliminating storage and disposal problems. Accordingly, we are developing an in-situ approach to electrochemically generate hydrogen peroxide disinfecting solution utilizing onboard life support supplies (Air/Water) to neutralize surface microorganisms present in closed living systems. As discussed within our 2019 and 2021 ICES papers (ICES-2019-38 and ICES-2021-273), we have continued to improve our TRL by scaling the electrochemical generation production process and validating the system in a zero-gravity parabolic loop flight test. In this paper we will demonstrate a system that can achieve over 1 L of >2 w/w% peroxide per day with DI water and air feeds. The hydrogen peroxide solutions generated were sent to NASA for microbial control property characterization. Overall, the electrochemical peroxide generation system offers a more economical and practical alternative, with the disinfectant being generated on demand and in-situ (using available life support materials of Air/Water); and applied to reusable cloths. The specific application of interest to this program is crew contact surfaces in space vehicles, but this technology could be utilized for waste water disinfection, heat exchanger biofouling remediation, and laundry applications. The peroxide generation system will also be able to address Earth-based needs in various settings such as field hospitals, restaurants, military, warehouses, movie theatres, among many others.

hydrogen peroxide↗

New formaldehyde base disinfectants.

Preparations of formaldehyde in various organic liquids - ethylene glycol, glycerol, and propylene glycol - serve as effective disinfectants towards microbial vegetative cells and spores. This disinfection is a temperature-dependent process and is manifest when these formaldehyde base disinfectants are dissolved in water. The irritating vapors associated with formaldehyde disinfection are not present in either of these new formaldehyde base disinfectants or in aqueous solutions of them.

Trujillo, R.↗

Efficacy of Various Chemical Disinfectants on Biofilms Formed in Spacecraft Potable Water System Component

As the provision of potable water is critical for successful habitation of the International Space Station (ISS), life support systems were installed in December 2008 to recycle both humidity from the atmosphere and urine to conserve available water in the vehicle. Pre-consumption testing from the dispensing needle at the Potable Water Dispenser (PWD) indicated that bacterial concentrations exceeded the current ISS specifications of 50 colony forming units (CFU) per ml. Subsequent investigations revealed that a corrugated stainless steel flex hose upstream of the dispensing needle in the PWD was filled with non-sterile water and left at room temperature for over one month before launch. To simulate biofilm formation that was suspected in the flight system, sterile flex hoses were seeded with a consortium of bacterial isolates previously recovered from other ISS water systems, which included Ralstonia pickettii, Burkholderia multivorans, Caulobacter vibrioides., and Cupriavidus pauculus. After 5 days of incubation, these hoses were challenged with various chemical disinfectants including hydrogen peroxide, colloidal silver, and buffered pH solutions to determine the ability of the disinfectants to decrease and maintain bacterial concentrations below ISS specifications. Disinfection efficacy over time was measured by collecting daily heterotrophic plate counts following exposure to the disinfectants. A single flush with either 6% hydrogen peroxide solution or a mixture of 3% hydrogen peroxide and 400 ppb colloidal silver effectively reduced the bacterial concentrations to less than 1 CFU/ml for a period of up to 2 months. Testing results indicated that hydrogen peroxide and mixtures of hydrogen peroxide and colloidal silver have tremendous potential as alternative disinfectants for ISS water systems.

Wong, Willy↗

Evaluation of Electrochemically Generated Potable Water Disinfectants for Use on the International Space Station

Microbial contamination and subsequent growth in spacecraft water systems are constant concerns for missions involving human crews. The current potable water disinfectant is iodine; however, with the end of the Space Shuttle program, there is a need to develop redundant biocide systems which are less dependent on hardware that would need to be launched on a regular basis. Three systems for electrochemical production of potable water disinfectants are being assessed for use on the International Space Station (ISS). Since there is a wide variability in the literature with regards to efficacy in both concentration and exposure time of these disinfectants, there is a need to establish baseline efficacy values. This paper describes a series of tests performed in order to establish optimal concentrations and exposure times for four disinfectants against single and mixed species planktonic and biofilm bacteria and to determine whether these electrochemical disinfection devices are able to produce a sufficient amount of chemical in both concentration and volume to act as a biocide for potable water on ISS.

Vega, Leticia↗

Corrosion control and disinfection studies in spacecraft water systems

Disinfection and corrosion control in the water systems of the Saturn 5 Orbital Workshop Program are considered. Within this framework, the problem areas of concern are classified into four general areas: disinfection; corrosion; membrane-associated problems of disinfectant uptake and diffusion; and taste and odor problems arising from membrane-disinfectant interaction.

Shea, T. G.↗

Effects of Disinfectants in Water on Mir- and Earth-Grown Wheat

Iodine and silver fluoride are used to purify water onboard U. S. Shuttles and the Russian Space Station, Mir, respectively. In 1995, iodine-treated water, which ranged from 1.0-4.0 mg x kg(exp -1) with a mean of 2.9 mg x kg(exp -1), was applied to Super Dwarf wheat (Triticum aestivum L.) plants when Mir water (grey or tech grade) became scarce. The potential phytotoxicity of iodine on Super Dwarf wheat is an unknown. Since use of iodine-treated water was not part of the experiment, we sought to determine whether it accounted for the subsequent poor wheat seedling growth and floral development onboard the Mir. Super Dwarf wheat seeds were imbibed in iodine or silver fluoride concentrations of 0.0, 1.0, 2.0, 4.0, 8.0 or 16.0 mg x kg(exp -1) for 96 h at 4 C. Five seeds were then planted per 13.3 cm x 13.3 cm pots containing a granular clinoptilolite (Cp) zeolite (1 -2 mm dia.) and placed in Percival(TM) growth chambers programmed for 20/15 C and 18/6 h d/n regime. Plants were irrigated with distilled water, and Iodine- or silver fluoride-treated distilled water. In separate experiments, seeds were treated as above and germination and early seedling growth were determined by examining seedling responses to disinfectants in rolled paper towels. Silver fluoride had very little effect on wheat seed germination. By contrast, iodine reduced germination at all treatment levels. Seedlings exposed to 1.0, 2.0, and 4.0 mg x kg(exp -1) of iodine or silver fluoride levels exhibited a slight stimulation in shoot and root growth. Both disinfectants at 8 and 16 mg x kg(exp -1) showed significantly (p is less than or equal to 0.01) reduced seedling shoot and root lengths and fresh biomasses compared to the control and lower disinfectant levels. The number of spikelets per spike, florets per spikelet, seeds per spike and seed weight were also significantly reduced at the 8 and 16 mg x kg(exp -1) compared to the control and lower levels of disinfectant. Based on these ground-based post-flight analyses, the levels of iodine- and/or silver fluoride-treated water used on Mir-grown plants onboard the Mir did not cause the poor growth and development of the wheat plants.

Campbell, William .F.↗

Pilot Study for UVA-LED Disinfection of Escherichia coli in Water for Space and Earth Applications

To test the efficacy of UVA-LED disinfection, a solution of Escherichia coli was pumped through a modified drip flow reactor at a flow rate of 1 ml/min. The experiment was conducted in a controlled environment chamber to ensure that temperature did not cause disinfection. The reactor featured three wells with different treatments: UVA-LED irradiation, UVA-LEDs with Ti02, and UVA-LEDs with nanosilver. Samples from each well were taken throughout a 340 hour period, inactivated, assayed, and analyzed for E. coli disinfection. Results of the duplicate experiments indicated longer exposure times are needed for UVA-LED disinfection of E. coli in water. Further research would consider a longer sampling period and different test conditions, such as increased contact area and various flow rates.

Ragolta, Carolina↗

Disinfection of Spacecraft Potable Water Systems by Photocatalytic Oxidation Using UV-A Light Emitting Diodes

Ultraviolet (UV) light has long been used in terrestrial water treatment systems for photodisinfection and the removal of organic compounds by several processes including photoadsorption, photolysis, and photocatalytic oxidation/reduction. Despite its effectiveness for water treatment, UV has not been explored for spacecraft applications because of concerns about the safety and reliability of mercury-containing UV lamps. However, recent advances in ultraviolet light emitting diodes (UV LEDs) have enabled the utilization of nanomaterials that possess the appropriate optical properties for the manufacture of LEDs capable of producing monochromatic light at germicidal wavelengths. This report describes the testing of a commercial-off-the-shelf, high power Nichia UV-A LED (250mW A365nnJ for the excitation of titanium dioxide as a point-of-use (POD) disinfection device in a potable water system. The combination of an immobilized, high surface area photocatalyst with a UV-A LED is promising for potable water system disinfection since toxic chemicals and resupply requirements are reduced. No additional consumables like chemical biocides, absorption columns, or filters are required to disinfect and/or remove potentially toxic disinfectants from the potable water prior to use. Experiments were conducted in a static test stand consisting of a polypropylene microtiter plate containing 3mm glass balls coated with titanium dioxide. Wells filled with water were exposed to ultraviolet light from an actively-cooled UV-A LED positioned above each well and inoculated with six individual challenge microorganisms recovered from the International Space Station (ISS): Burkholderia cepacia, Cupriavidus metallidurans, Methylobacterium fujisawaense, Pseudomonas aeruginosa, Sphingomonas paucimobilis and Wautersia basilensis. Exposure to the Nichia UV-A LED with photocatalytic oxidation resulted in a complete (>7-log) reduction of each challenge bacteria population in <180 minutes of contact time. With continued advances in the design and manufacture of UV-A LEDs and semi-conducting photocatalysts, LED activated photochemical process technology promises to extend its application to spacecraft environmental systems.

Birmele, Michele N.↗

Evaluation of Electrochemically Generated Potable Water Disinfectants for Use on the International Space Station

Microbial contamination and subsequent growth in spacecraft water systems are constant concerns for missions involving human crews. The current potable water disinfectant for the International Space Station (ISS) is iodine; however, with the end of the Space Shuttle program, there is a need to develop redundant biocide systems that do not require regular up ]mass dependencies. Throughout the course of a year, four different electrochemical systems were investigated as a possible biocide for potable water on the ISS. Research has indicated that there is a wide variability with regards to efficacy in both concentration and exposure time of these disinfectants, therefore baseline efficacy values were established. This paper describes a series of tests performed in order to establish optimal concentrations and exposure times for four disinfectants against single and mixed species planktonic and biofilm bacteria. Results of the testing determined whether these electrochemical disinfection systems are able to produce a sufficient amount of chemical in both concentration and volume to act as a biocide for potable water on ISS.

Rodriquez, Branelle↗

Material Testing in Support of the ISS Electrochemical Disinfection Feasibility Study

Microbial contamination and subsequent growth in spacecraft water systems are constant concerns for missions involving human crews. The current potable water disinfectant for the International Space Station (ISS) is iodine; however, with the end of the Space Shuttle program, there is a need to develop redundant biocide systems that do not require regular up ]mass dependencies. Throughout the course of a year, four different electrochemical systems were investigated as a possible biocide for potable water on the ISS. Research has indicated that there is a wide variability with regards to efficacy in both concentration and exposure time of these disinfectants, therefore baseline efficacy values were established. This paper describes a series of tests performed in order to establish optimal concentrations and exposure times for four disinfectants against single and mixed species planktonic and biofilm bacteria. Results of the testing determined whether these electrochemical disinfection systems are able to produce a sufficient amount of chemical in both concentration and volume to act as a biocide for potable water on ISS.

Rodriquez, Branelle↗

Evaluation of Electrochemically Generated Potable Water Disinfectants for Use on the International Space Station

Microbial contamination and subsequent growth in spacecraft water systems are constant concerns for missions involving human crews. The current potable water disinfectant for the International Space Station (ISS) is iodine; however, with the end of the Space Shuttle Program, there is a need to develop redundant biocide systems that do not require regular up-mass dependencies. Throughout the course of a year, four different electrochemical systems were investigated as a possible biocide for potable water on the ISS. Research has indicated that a wide variability exists with regards to efficacy in both concentration and exposure time of these disinfectants; therefore, baseline efficacy values were established. This paper describes a series of tests performed to establish optimal concentrations and exposure times for four disinfectants against single and mixed species planktonic and biofilm bacteria. Results of the testing determined whether these electrochemical disinfection systems are able to produce a sufficient amount of chemical in both concentration and volume to act as a biocide for potable water on the ISS.

Rodriquez, Branelle↗

Literature Review of Disinfection Techniques For Water Treatment

Water treatment is a developing concern, both terrestrially and in spacecraft, as exploration missions extend in time and distance. Current biofilm control is limited for long-term applications. To optimize biocides for present and future space exploration vehicles, a thorough understanding of common and traditional disinfectant techniques is required. This review is focused on the three fundamental disinfection techniques: chemical, physical, and biological. Mechanisms, advantages, disadvantages, and specific properties of each major technique, as well as their studied effect on established biofilms, are also considered. This paper provides a general background on disinfectants and some information on effects on biofilms that can be useful to develop innovative ideas for state-of-the-art disinfection techniques for water treatment in specific environments, such as those currently posing mission risks as well as for future spacecraft water system development.

Nilab Azim↗