Search NASA⌕ Search

SEARCH · Search NASA

Results for “distance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

DISTANCES TO DARK CLOUDS: COMPARING EXTINCTION DISTANCES TO MASER PARALLAX DISTANCES

We test two different methods of using near-infrared extinction to estimate distances to dark clouds in the first quadrant of the Galaxy using large near-infrared (Two Micron All Sky Survey and UKIRT Infrared Deep Sky Survey) surveys. Very long baseline interferometry parallax measurements of masers around massive young stars provide the most direct and bias-free measurement of the distance to these dark clouds. We compare the extinction distance estimates to these maser parallax distances. We also compare these distances to kinematic distances, including recent re-calibrations of the Galactic rotation curve. The extinction distance methods agree with the maser parallax distances (within the errors) between 66% and 100% of the time (depending on method and input survey) and between 85% and 100% of the time outside of the crowded Galactic center. Although the sample size is small, extinction distance methods reproduce maser parallax distances better than kinematic distances; furthermore, extinction distance methods do not suffer from the kinematic distance ambiguity. This validation gives us confidence that these extinction methods may be extended to additional dark clouds where maser parallaxes are not available.

79 ASTRONOMY AND ASTROPHYSICS↗

Distance probes of dark energy

This document presents the results from the Distances subgroup of the Cosmic Frontier Community Planning Study (Snowmass 2013). We summarize the current state of the field as well as future prospects and challenges. In addition to the established probes using Type Ia supernovae and baryon acoustic oscillations, we also consider prospective methods based on clusters, active galactic nuclei, gravitational wave sirens and strong lensing time delays.

Cosmology↗

Spin Sum Rules and the Strong Coupling Constant at large distance

We present recent results on the Bjorken and the generalized forward spin polarizability sum rules from Jefferson Lab Hall A and CLAS experiments, focusing on the low Q{sup 2} part of the measurements. We then discuss the comparison of these results with Chiral Perturbation theory calculations. In the second part of this paper, we show how the Bjorken sum rule with its connection to the Gerasimov-Drell-Hearn sum, allows us to conveniently define an effective coupling for the strong force at all distances.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Rigorous force field optimization principles based on statistical distance minimization

We use the concept of statistical distance to define a measure of distinguishability between a pair of statistical mechanical systems, i.e., a model and its target, and show that its minimization leads to general convergence of the model’s static measurable properties to those of the target. We exploit this feature to define a rigorous basis for the development of accurate and robust effective molecular force fields that are inherently compatible with coarse-grained experimental data. The new model optimization principles and their efficient implementation are illustrated through selected examples, whose outcome demonstrates the higher robustness and predictive accuracy of the approach compared to other currently used methods, such as force matching and relative entropy minimization. We also discuss relations between the newly developed principles and established thermodynamic concepts, which include the Gibbs-Bogoliubov inequality and the thermodynamic length.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantifying cell migration distance as a contributing factor to the development of rectal toxicity after prostate radiotherapy

Purpose: Spatial information is usually neglected in mathematical models of radiation-induced toxicity. In the presence of inhomogeneous dose distributions produced by intensity modulated radiation therapy (IMRT) and volumetric arc therapy, this may be a limitation. We present a model to quantify the spatial characteristics of the dose distribution on the rectum through the quantification of the distribution of distances between dose points on the surface of the rectum in three-dimensions. The method allows us to evaluate the hypothesis that distances between lower and higher dose regions on the rectum influence radiation damage repair due to the migration of normal cells into damaged areas, and consequently, the development of radiation-induced toxicity in patients treated with radiation for prostate cancer. Methods: We present a method to compute distances between dose points on the surface of the rectum in three dimensions (3D) and to generate distance maps representing the distances between specific dose regions on the rectum. We introduce the concept of the distance dose surface histogram (DDSH), which is computed from the distance maps. The DDSH is a 2D histogram of rectum area on a grid defined by pairwise combinations of dose and distance. Each bin in the DDSH quantifies the area of the rectum exposed to a given dose and at a given distance from other another dose region on the rectum. By summing across the columns and rows of the DDSH, we can generate the dose surface histogram (DSH) and distance surface histogram (DiSH) for a particular dose region. The DiSH is a marginal histogram showing the distribution of distances for the dose points in a specific dose region from another region. We computed the DDSH, DiSH, and DSH for 33 patients treated with IMRT for prostate cancer, nine of whom developed late Grade 2 or higher late rectal toxicity. Results: We show how even though the total area of the rectum exposed to a given dose may be the same for different patients, the distribution of distances for points receiving that dose can be different depending on the shape and contiguity of the region(s) containing those dose points. We also show that area of the rectum in the region receiving more than 75 Gy and at a distance of 16 to 22 mm from the 50 Gy isodose line was significantly correlated to the development of toxicity (p = 0.004, two sided t-test). This suggests that examining the distance distribution of points in specific dose regions could provide valuable additional information in predicting the risk of a patient developing radiation-induced rectal toxicity. Conclusions: We present a new method to quantify the spatial distribution of points in a given region relative to other regions on the rectum. The method provides a means to evaluate the hypothesis that distances between lower and higher dose regions on the rectum influence radiation damage repair due to the migration of normal cells into damaged areas, and may be a contributing factor to the development of radiation-induced toxicity in patients treated with radiation for prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TYPE Ia SUPERNOVA PROPERTIES AS A FUNCTION OF THE DISTANCE TO THE HOST GALAXY IN THE SDSS-II SN SURVEY

We use Type Ia supernovae (SNe Ia) discovered by the Sloan Digital Sky Survey-II SN Survey to search for dependencies between SN Ia properties and the projected distance to the host-galaxy center, using the distance as a proxy for local galaxy properties (local star formation rate, local metallicity, etc.). The sample consists of almost 200 spectroscopically or photometrically confirmed SNe Ia at redshifts below 0.25. The sample is split into two groups depending on the morphology of the host galaxy. We fit light curves using both MLCS2K2 and SALT2, and determine color (A{sub V} , c) and light-curve shape ({Delta}, x{sub 1}) parameters for each SN Ia, as well as its residual in the Hubble diagram. We then correlate these parameters with both the physical and the normalized distances to the center of the host galaxy and look for trends in the mean values and scatters of these parameters with increasing distance. The most significant (at the 4{sigma} level) finding is that the average fitted A{sub V} from MLCS2K2 and c from SALT2 decrease with the projected distance for SNe Ia in spiral galaxies. We also find indications that supernovae (SNe) in elliptical galaxies tend to have narrower light curves if they explode at larger distances, although this may be due to selection effects in our sample. We do not find strong correlations between the residuals of the distance moduli with respect to the Hubble flow and the galactocentric distances, which indicates a limited correlation between SN magnitudes after standardization and local host metallicity.

79 ASTRONOMY AND ASTROPHYSICS↗

ESTIMATION OF DISTANCES TO STARS WITH STELLAR PARAMETERS FROM LAMOST

We present a method to estimate distances to stars with spectroscopically derived stellar parameters. The technique is a Bayesian approach with likelihood estimated via comparison of measured parameters to a grid of stellar isochrones, and returns a posterior probability density function for each star’s absolute magnitude. This technique is tailored specifically to data from the Large Sky Area Multi-object Fiber Spectroscopic Telescope (LAMOST) survey. Because LAMOST obtains roughly 3000 stellar spectra simultaneously within each ∼5° diameter “plate” that is observed, we can use the stellar parameters of the observed stars to account for the stellar luminosity function and target selection effects. This removes biasing assumptions about the underlying populations, both due to predictions of the luminosity function from stellar evolution modeling, and from Galactic models of stellar populations along each line of sight. Using calibration data of stars with known distances and stellar parameters, we show that our method recovers distances for most stars within ∼20%, but with some systematic overestimation of distances to halo giants. We apply our code to the LAMOST database, and show that the current precision of LAMOST stellar parameters permits measurements of distances with ∼40% error bars. This precision should improve as the LAMOST data pipelines continue to be refined.

79 ASTRONOMY AND ASTROPHYSICS↗

Distance-preserving rigidity penalty on deformable image registration of multiple skeletal components in the neck

Purpose: This study aims at developing and testing a novel rigidity penalty suitable for the deformable registration of tightly located skeletal components in the head and neck from planning computed tomography (CT) and daily cone-beam CT (CBCT) scans of patients undergoing radiotherapy. Methods: The proposed rigidity penalty is designed to preserve intervoxel distances within each bony structure. This penalty was tested in the intensity-based B-spline deformable registration of five cervical vertebral bodies (C1–C5). The displacement vector fields (DVFs) from the registrations were compared to the DVFs generated by using rigid body motions of the cervical vertebrae, measured by the surface registration of vertebrae delineated on CT and CBCT images. Twenty five pairs of planning CT (reference) and treatment CBCTs (target) from five patients were aligned without and with the penalty. An existing penalty based on the orthonormality of the deformation gradient tensor was also tested and the effects of the penalties compared. Results: The mean magnitude of the maximum registration error with the proposed distance-preserving penalty was (0.86, 1.12, 1.33) mm compared to (2.11, 2.49, 2.46) without penalty and (1.53, 1.64, 1.64) with the existing orthonormality-based penalty. The improvement in the accuracy of the deformable image registration was also verified by comparing the Procrustes distance between the DVFs. With the proposed penalty, the average distance was 0.11 (σ 0.03 mm) which is smaller than 0.53 (0.1 mm) without penalty and 0.28 (0.04 mm) with the orthonormality-based penalty. Conclusions: The accuracy of aligning multiple bony elements was improved by using the proposed distance-preserving rigidity penalty. The voxel-based statistical analysis of the registration error shows that the proposed penalty improved the integrity of the DVFs within the vertebral bodies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chiral dynamics and partonic structure at large transverse distances

In this paper, we study large-distance contributions to the nucleon’s parton densities in the transverse coordinate (impact parameter) representation based on generalized parton distributions (GPDs). Chiral dynamics generates a distinct component of the partonic structure, located at momentum fractions x≲M π /M N and transverse distances b~1/M π . We calculate this component using phenomenological pion exchange with a physical lower limit in b (the transverse “core” radius estimated from the nucleon’s axial form factor, R core =0.55 fm) and demonstrate its universal character. This formulation preserves the basic picture of the “pion cloud” model of the nucleon’s sea quark distributions, while restricting its application to the region actually governed by chiral dynamics. It is found that (a) the large-distance component accounts for only ~1/3 of the measured antiquark flavor asymmetry d¯-u¯ at x~0.1; (b) the strange sea quarks s and s¯ are significantly more localized than the light antiquark sea; (c) the nucleon’s singlet quark size for x<0.1 is larger than its gluonic size, (b 2 ) q+q¯ >(b 2 ) g , as suggested by the t-slopes of deeply-virtual Compton scattering and exclusive J/ψ production measured at HERA and FNAL. We show that our approach reproduces the general N c -scaling of parton densities in QCD, thanks to the degeneracy of N and Δ intermediate states in the large-N c limit. Finally, we also comment on the role of pionic configurations at large longitudinal distances and the limits of their applicability at small x.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The young and bright type ia supernova ASASSN-14lP: discovery, early-time observations, first-light time, distance to NGC 4666, and progenitor constraints

On 2014 December 9.61, the All-sky Automated Survey for SuperNovae (ASAS-SN or “Assassin”) discovered ASASSN-14lp just ∼2 days after first light using a global array of 14 cm diameter telescopes. ASASSN-14lp went on to become a bright supernova (V = 11.94 mag), second only to SN 2014J for the year. We present prediscovery photometry (with a detection less than a day after first light) and ultraviolet through near-infrared photometric and spectroscopic data covering the rise and fall of ASASSN-14lp for more than 100 days. We find that ASASSN-14lp had a broad light curve (Δm{sub 15}(B)=0.80±0.05), a B-band maximum at 2457015.82 ± 0.03, a rise time of 16.94{sub −0.10}{sup +0.11} days, and moderate host-galaxy extinction (E(B−V){sub host}=0.33±0.06). Using ASASSN-14lp, we derive a distance modulus for NGC 4666 of μ=30.8±0.2, corresponding to a distance of 14.7 ± 1.5 Mpc. However, adding ASASSN-14lp to the calibrating sample of Type Ia supernovae still requires an independent distance to the host galaxy. Finally, using our early-time photometric and spectroscopic observations, we rule out red giant secondaries and, assuming a favorable viewing angle and explosion time, any nondegenerate companion larger than 0.34 R{sub ⊙}.

79 ASTRONOMY AND ASTROPHYSICS↗

Bremsstrahlung versus Monoenergetic Photon Dose and Photonuclear Stimulation Comparisons at Long Standoff Distances

Energetic photon sources with energies greater than 6 MeV continue to be recognized as viable source for various types of inspection applications, especially those related to nuclear and/or explosive material detection. These energetic photons can be produced as a continuum of energies (i.e., bremsstrahlung) or as a set of one or more discrete photon energies (i.e., monoenergetic). This paper will provide a follow-on extension of the photon dose comparison presented at the 9th International Conference on Applications of Nuclear Techniques (June 2008). Our previous paper showed the comparative advantages and disadvantages of the photon doses provided by these two energetic interrogation sources and highlighted the higher energy advantage of the bremsstrahlung source, especially at long standoff distances (i.e., distance from source to the inspected object). This paper will pursue higher energy photon inspection advantage (up to 100 MeV) by providing dose and stimulated photonuclear interaction predictions in air and for an infinitely dilute interrogated material (used for comparative interaction rate assessments since it excludes material self-shielding) as the interrogation object positioned forward on the inspection beam axis at increasing standoff distances. In addition to the direct energetic photon-induced stimulation, the predictions will identify the importance of secondary downscattered/attenuated source-term effects arising from the photon transport in the intervening air environment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

VLBA DETERMINATION OF THE DISTANCE TO NEARBY STAR-FORMING REGIONS. V. DYNAMICAL MASS, DISTANCE, AND RADIO STRUCTURE OF V773 Tau A

We present multi-epoch Very Long Baseline Array (VLBA) observations of V773 Tau A, the 51 day binary subsystem in the multiple young stellar system V773 Tau. Combined with previous interferometric and radial velocity measurements, these new data enable us to improve the characterization of the physical orbit of the A subsystem. In particular, we infer updated dynamical masses for the primary and the secondary components of 1.55 {+-} 0.11 M{sub Sun} and 1.293 {+-} 0.068 M{sub Sun }, respectively, and an updated orbital parallax distance to the system of 135.7 {+-} 3.2 pc, all consistent with previous estimates. Using the improved orbit, we can calculate the absolute coordinates of the barycenter of V773 Tau A at each epoch of our VLBA observations, and fit for its trigonometric parallax and proper motion. This provides a direct measurement of the distance to the system almost entirely independent of the orbit modeling. The best fit yields a distance of 129.9 {+-} 3.2 pc, in good agreement (i.e., within 1{sigma}) with the distance estimate based on the orbital fit. Taking the mean value of the orbital and trigonometric parallaxes, we conclude that V773 Tau is located at d = 132.8 {+-} 2.3 pc. The accuracy of this determination is nearly one order of magnitude better than that of previous estimates. In projection, V773 Tau and two other young stars (Hubble 4 and HDE 283572) recently observed with the VLBA are located toward the dark cloud Lynds 1495, in the central region of Taurus. These three stars appear to have similar trigonometric parallaxes, radial velocities, and proper motions, and we argue that the weighted mean and dispersion of their distances (d = 131.4 pc and {sigma}{sub d} = 2.4 pc) provide a good estimate of the distance to and depth of Lynds 1495 and its associated stellar population. The radio emission from the two sources in V773 Tau A is largely of gyrosynchrotron origin. Interestingly, both sources are observed to become typically five times brighter near periastron than near apastron (presumably because of increased flaring activity), and the separation between the radio sources near periastron appears to be systematically smaller than the separation between the stars. While this clearly indicates some interaction between the individual magnetospheres, the exact mechanisms at play are unclear because even at periastron the separation between the stars ({approx}30 R{sub *}) remain much larger than the radius of the magnetospheres around these low-mass young stars ({approx}6 R{sub *}).

79 ASTRONOMY AND ASTROPHYSICS↗

A short working distance multiple crystal x-ray spectrometer

For x-ray spot sizes of a few tens of microns or smaller, a millimeter-sized flat analyzer crystal placed {approx}1 cm from the sample will exhibit high energy resolution while subtending a collection solid angle comparable to that of a typical spherically bent crystal analyzer (SBCA) at much larger working distances. Based on this observation and a nonfocusing geometry for the analyzer optic, we have constructed and tested a short working distance (SWD) multicrystal x-ray spectrometer. This prototype instrument has a maximum effective collection solid angle of 0.14 sr, comparable to that of 17 SBCA at 1 m working distance. We find good agreement with prior work for measurements of the Mn K{beta} x-ray emission and resonant inelastic x-ray scattering for MnO, and also for measurements of the x-ray absorption near-edge structure for Dy metal using L{alpha}{sub 2} partial-fluorescence yield detection. We discuss future applications at third- and fourth-generation light sources. For concentrated samples, the extremely large collection angle of SWD spectrometers will permit collection of high-resolution x-ray emission spectra with a single pulse of the Linac Coherent Light Source. The range of applications of SWD spectrometers and traditional multi-SBCA instruments has some overlap, but also is significantly complementary.

36 MATERIALS SCIENCE↗

On the Impact of Income, Age, and Travel Distance on the Value of Time

The value of time (VOT) is a fundamental component used in transportation modeling, policy analysis, and economic appraisal. Decades of research and practice have empirically estimated the VOT across many factors (e.g., mode, purpose, time, comfort, etc.), yet little is known about its underlying form. Although it is well established that VOT can vary, it is still unclear whether patterns exist in this variation. The objective of this paper is not to merely estimate the VOT, but to model the VOT across multiple continuous and interacting variables. The purpose is to reveal its functional form with respect to mode, age, gender, purpose, income, and time of day to provide a generalizable understanding for future research and practice. Such an understanding can help develop simpler models and reduce the need for bespoke estimations for every conceivable variable perturbation. This research utilized a household travel survey containing 14,159 reported trips with imputed travel time and costs for the alternative mode choices. The average overall estimated VOT is 40.32 $/h, with results showing VOT varying log-linearly with income and trip distance, but following a Gaussian function (normal curve) with age. Overall, the results show that travel distance dominates VOT variation, which increases exponentially at a rate that is 3.61 times higher per mile of distance than per $10,000 of income, and that VOT by age peaks at age 54. This basic understanding of how the VOT varies sets the foundation for answering the subsequent question for why it might vary.

Engineering↗

The Gould's Belt Distances Survey (GOBELINS). I. Trigonometric parallax distances and depth of the ophiuchus complex

We present the first results of the Gould’s Belt Distances Survey (GOBELINS), a project aimed at measuring the proper motion and trigonometric parallax of a large sample of young stars in nearby regions using multi-epoch Very Long Baseline Array (VLBA) radio observations. Enough VLBA detections have now been obtained for 16 stellar systems in Ophiuchus to derive their parallax and proper motion. This leads to distance determinations for individual stars with an accuracy of 0.3 to a few percent. In addition, the orbits of six multiple systems were modelled by combining absolute positions with VLBA (and, in some cases, near-infrared) angular separations. Twelve stellar systems are located in the dark cloud Lynds 1688; the individual distances for this sample are highly consistent with one another and yield a mean parallax for Lynds 1688 of ϖ=7.28±0.06 mas, corresponding to a distance d=137.3±1.2 pc. This represents an accuracy greater than 1%. Three systems for which astrometric elements could be measured are located in the eastern streamer (Lynds 1689) and yield an estimate of ϖ=6.79±0.16 mas, corresponding to a distance d=147.3±3.4 pc. This suggests that the eastern streamer is located about 10 pc farther than the core, but this conclusion needs to be confirmed by observations of additional sources in the eastern streamer (currently being collected). From the measured proper motions, we estimate the one-dimensional velocity dispersion in Lynds 1688 to be 2.8 ± 1.8 and 3.0 ± 2.0 km s{sup −1}, in R.A. and decl., respectively; these are larger than, but still consistent within 1σ of, those found in other studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Distance Restraints from Crosslinking Mass Spectrometry: Mining a Molecular Dynamics Simulation Database to Evaluate Lysine-Lysine Distances

Integrative structural biology models the structures of protein complexes that are intractable by classical structural methods (because of extreme size, dynamics, or heterogeneity) by combining computational structural modeling with data from experimental methods. One such method is chemical cross-linking mass spectrometry (XL-MS), in which cross-linked peptides, derived from a covalently cross-linked protein complex and identified by liquid chromatography-mass spectrometry, pinpoint protein residues close in three-dimensional space. The commonly used lysine-reactive N-hydroxysuccinimide ester reagents disuccinimidylsuberate (DSS) and bis(sulfosuccinimidyl)suberate (BS3) have a linker arm that is 11.4 Å long when fully extended. However, XL-MS studies on proteins of known structure frequently report cross-links that exceed this distance. Typically, a tolerance of ~3 Å is added to the theoretical maximum to account for this observation, with little justification for the value chosen. We used the Dynameomics database, a repository of high-quality molecular dynamics simulations of 807 proteins representative of all protein folds, to investigate the change in lysine-lysine distances resulting from native-state dynamics on the time-scale of tens of nanoseconds. We conclude that observed cross-links are consistent with a protein structure if the distance between cross-linked lysine Nζ atoms is less than the cross-linker length plus 11.3 Å. For DSS or BS3, this corresponds to a Cα to Cα distance of 30.4 Å. This analysis provides a theoretical basis for the widespread practice of adding a tolerance to the crosslinker length when comparing XL-MS results to structures, and indicates the appropriate values of an XLMS derived distance constraint to use in structural modeling.

Environmental Molecular Sciences Laboratory↗