Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed average tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Non-relativistic Free–Free Emission due to the n -distribution of Electrons—Radiative Cooling and Thermally Averaged and Total Gaunt Factors

Tracking the thermal evolution of plasmas, characterized by an n -distribution, using numerical simulations, requires the determination of the emission spectra and of the radiative losses due to free–free emission from the corresponding temperature-averaged and total Gaunt factors. Detailed calculations of the latter are presented and associated with n -distributed electrons with the parameter n ranging from 1 (corresponding to the Maxwell–Boltzmann distribution) to 100. The temperature-averaged and total Gaunt factors with decreasing n tend toward those obtained with the Maxwell–Boltzmann distribution. Radiative losses due to free–free emission in a plasma evolving under collisional ionization equilibrium conditions and composed by H, He, C, N, O, Ne, Mg, Si, S, and Fe ions, are presented. These losses decrease with a decrease in the parameter n , reaching a minimum when n = 1, and thus converge with the loss of thermal plasma. Tables of the thermal-averaged and total Gaunt factors calculated for n -distributions, and a wide range of electron and photon energies, are presented.

79 ASTRONOMY AND ASTROPHYSICS↗

Exosomes secreted by placental stem cells selectively inhibit growth of aggressive prostate cancer cells

Highlights: • Detailed characterization of exosomes secreted by human placental stem cells (PLSC{sup Exo}) . • Identified anti-cancer efficacy of PLSC{sup Exo} against aggressive prostate cancer cells. • Retinoic acid receptor/Liver x receptor pathway seems central to PLSC{sup Exo} biological effects. The current paradigm in the development of new cancer therapies is the ability to target tumor cells while avoiding harm to noncancerous cells. Furthermore, there is a need to develop novel therapeutic options against drug-resistant cancer cells. Herein, we characterized the placental-derived stem cell (PLSC) exosomes (PLSC{sup Exo}) and evaluated their anti-cancer efficacy in prostate cancer (PCa) cell lines. Nanoparticle tracking analyses revealed the size distribution (average size 131.4 ± 0.9 nm) and concentration of exosomes (5.23 × 10{sup 10}±1.99 × 10{sup 9} per ml) secreted by PLSC. PLSC{sup Exo} treatment strongly inhibited the viability of enzalutamide-sensitive and -resistant PCa cell lines (C4-2B, CWR-R1, and LNCaP cells). Interestingly, PLSC{sup Exo} treatment had no effect on the viability of a non-neoplastic human prostate cell line (PREC-1). Mass spectrometry (MS) analyses showed that PLSC{sup Exo} are loaded with 241 proteins and mainly with saturated fatty acids. Further, Ingenuity Pathway Analysis analyses of proteins loaded in PLSC{sup Exo} suggested the role of retinoic acid receptor/liver x receptor pathways in their biological effects. Together, these results suggest the novel selective anti-cancer effects of PLSC{sup Exo} against aggressive PCa cells.

60 APPLIED LIFE SCIENCES↗

Accurate Consensus-based Distributed Averaging with Variable Time Delay in Support of Distributed Secondary Control Algorithms

We report that distributed secondary control has been widely used in hierarchical control structures, where multiple distributed generators (DGs) need to coordinate to regulate system voltage and frequency. In these systems, consensus algorithms determine the average of a group of dynamic states (e.g. voltages measured by a group of DGs). To be useful, consensus algorithms must be computationally efficient, stable and accurate. In practice, numerous practical implementation challenges significantly affect the consensus equilibrium. In this paper, we quantify the accuracy deviations of the distributed average observer algorithms proposed in the literature to demonstrate the problems with the state-of-the-art distributed averaging techniques. A novel approach is proposed that achieves accurate average tracking in the presence of time-varying communication delays among agents. In our implementation, time synchronization of all distributed controllers is enabled by a novel software platform, called Resilient Information Architecture Platform for the Smart Grid (RIAPS). The proposed distributed average observer is implemented on hardware controllers and its effectiveness is validated in a controller hardware-in-the-loop testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Toward Online Adaptive Hyperthermia Treatment Planning: Correlation Between Measured and Simulated Specific Absorption Rate Changes Caused by Phase Steering in Patients

Purpose: Hyperthermia is the clinical application of heat, in which tumor temperatures are raised to 40°C to 45°C. This proven radiation and chemosensitizer significantly improves clinical outcome for several tumor sites. Earlier studies of the use of pre-treatment planning for hyperthermia showed good qualitative but disappointing quantitative reliability. The purpose of this study was to investigate whether hyperthermia treatment planning (HTP) can be used more reliably for online adaptive treatment planning during locoregional hyperthermia treatments. Methods and Materials: This study included 78 treatment sessions for 15 patients with non-muscle-invasive bladder cancer. At the start of treatments, temperature rise measurements were performed with 3 different antenna settings optimized for each patient, from which the absorbed power (specific absorption rate [SAR]) was derived. HTP was performed based on a computed tomography (CT) scan in treatment position with the bladder catheter in situ. The SAR along the thermocouple tracks was extracted from the simulated SAR distributions. Correlations between measured and simulated (average) SAR values were determined. To evaluate phase steering, correlations between the changes in simulated and measured SAR values averaged over the thermocouple probe were determined for all 3 combinations of antenna settings. Results: For 42% of the individual treatment sessions, the correlation coefficient between measured and simulated SAR profiles was higher than 0.5, whereas 58% showed a weak correlation (R of <0.5). The overall correlation coefficient between measured and simulated average SAR was weak (R=0.31; P<.001). The measured and simulated changes in average SAR after adapting antenna settings correlated much better (R=0.70; P<.001). The ratio between the measured and simulated quotients of maximum and average SARs was 1.03 ± 0.26 (mean ± SD), indicating that HTP can also correctly predict the relative amplitude of SAR peaks. Conclusions: HTP can correctly predict SAR changes after adapting antenna settings during hyperthermia treatments. This allows online adaptive treatment planning, assisting the operator in determining antenna settings resulting in increased tumor temperatures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electromagnetic-Guided Dynamic Multileaf Collimator Tracking Enables Motion Management for Intensity-Modulated Arc Therapy

Purpose: Intensity-modulated arc therapy (IMAT) is attractive because of high-dose conformality and efficient delivery. However, managing intrafraction motion is challenging for IMAT. The purpose of this research was to develop and investigate electromagnetically guided dynamic multileaf collimator (DMLC) tracking as an enabling technology to treat moving targets during IMAT. Methods and Materials: A real-time three-dimensional DMLC-based target tracking system was developed and integrated with a linear accelerator. The DMLC tracking software inputs a real-time electromagnetically measured target position and the IMAT plan, and dynamically creates new leaf positions directed at the moving target. Low- and high-modulation IMAT plans were created for lung and prostate cancer cases. The IMAT plans were delivered to a three-axis motion platform programmed with measured patient motion. Dosimetric measurements were acquired by placing an ion chamber array on the moving platform. Measurements were acquired with tracking, without tracking (current clinical practice), and with the phantom in a static position (reference). Analysis of dose distribution differences from the static reference used a {gamma}-test. Results: On average, 1.6% of dose points for the lung plans and 1.2% of points for the prostate plans failed the 3-mm/3% {gamma}-test with tracking; without tracking, 34% and 14% (respectively) of points failed the {gamma}-test. The delivery time was the same with and without tracking. Conclusions: Electromagnetic-guided DMLC target tracking with IMAT has been investigated for the first time. Dose distributions to moving targets with DMLC tracking were significantly superior to those without tracking. There was no loss of treatment efficiency with DMLC tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of a pretreatment delivery quality assurance method for the CyberKnife Synchrony system

Purpose: To evaluate the geometric and dosimetric accuracies of the CyberKnife Synchrony respiratory tracking system (RTS) and to validate a method for pretreatment patient-specific delivery quality assurance (DQA). Methods: An EasyCube phantom was mounted on the ExacTrac gating phantom, which can move along the superior–inferior (SI) axis of a patient to simulate a moving target. The authors compared dynamic and static measurements. For each case, a Gafchromic EBT3 film was positioned between two slabs of the EasyCube, while a PinPoint ionization chamber was placed in the appropriate space. There were three steps to their evaluation: (1) the field size, the penumbra, and the symmetry of six secondary collimators were measured along the two main orthogonal axes. Dynamic measurements with deliberately simulated errors were also taken. (2) The delivered dose distributions (from step 1) were compared with the planned ones, using the gamma analysis method. The local gamma passing rates were evaluated using three acceptance criteria: 3% local dose difference (LDD)/3 mm, 2%LDD/2 mm, and 3%LDD/1 mm. (3) The DQA plans for six clinical patients were irradiated in different dynamic conditions, to give a total of 19 cases. The measured and planned dose distributions were evaluated with the same gamma-index criteria used in step 2 and the measured chamber doses were compared with the planned mean doses in the sensitive volume of the chamber. Results: (1) A very slight enlargement of the field size and of the penumbra was observed in the SI direction (on average <1 mm), in line with the overall average CyberKnife system error for tracking treatments. (2) Comparison between the planned and the correctly delivered dose distributions confirmed the dosimetric accuracy of the RTS for simple plans. The multicriteria gamma analysis was able to detect the simulated errors, proving the robustness of their method of analysis. (3) All of the DQA clinical plans passed the tests, both in static and dynamic conditions. No statistically significant differences were found between static and dynamic cases, confirming the high degree of accuracy of the Synchrony RTS. Conclusions: The presented methods and measurements verified the mechanical and dosimetric accuracy of the Synchrony RTS. Their method confirms the fact that the RTS, if used properly, is able to treat a moving target with great precision. By combining PinPoint ion chamber, EBT3 films, and gamma evaluation of dose distributions, their DQA method robustly validated the effectiveness of CyberKnife and Synchrony system.

60 APPLIED LIFE SCIENCES↗

Simulating self-powered neutron detector responses to infer burnup-induced power distribution perturbations in next-generation light water reactors

Understanding how 3D power distribution will be monitored throughout reactor core volumetric space in next-generation nuclear power reactors is crucial to the design, deployment, and licensing of these reactors. Although numerous techniques exist for 3D power distribution monitoring based on the response of both in situ and ex situ sensors currently implemented or proposed for use in the US reactor fleet, crucial details about these techniques are often unclear. The publicly available documentation does not include information such as how well these techniques are characterized and optimized in their implementations and the levels of uncertainty in the inferred 3D power distribution. The work described herein investigated a recently developed 3D power distribution inferencing method as applied to two next-generation reactor simulations: (1) the NuScale small modular reactor design and (2) the Westinghouse AP1000 design, both of which contain in-core strings of vanadium self-powered neutron detectors (SPNDs). This investigation considered a range of SPND string sensor densities, as well as a range of 3D power distribution axial segment sizes. In this work, SPND response simulation is informed by neutron flux calculations in representative homogenized cores. For the different sensor densities and power distribution axial segment sizes in these simulations, the average solution error, solver iterations, and run time were tracked to parameterize the sensor-core configuration.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AN INTRIGUING CHROMOSPHERIC JET OBSERVED BY HINODE: FINE STRUCTURE KINEMATICS AND EVIDENCE OF UNWINDING TWISTS

We report a chromospheric jet lasting for more than 1 hr observed by the Hinode Solar Optical Telescope in unprecedented detail. The ejection occurred in three episodes separated by 12-14 minutes, with the amount and velocity of material decreasing with time. The upward velocities range from 438 to 33 km s{sup -1}, while the downward velocities of the material falling back have smaller values (mean: -56km s{sup -1}) and a narrower distribution (standard deviation: 14km s{sup -1}). The average acceleration inferred from parabolic spacetime tracks is 141 m s{sup -2}, a fraction of the solar gravitational acceleration. The jet consists of fine threads (0.''5-2'' wide), which exhibit coherent, oscillatory transverse motions perpendicular to the jet axis and about a common equilibrium position. These motions propagate upward along the jet, with the maximum phase speed of 744+-11 km s{sup -1}at the leading front of the jet. The transverse oscillation velocities range from 151 to 26 km s{sup -1}, amplitudes from 6.0 to 1.9 Mm, and periods from 250 to 536 s. The oscillations slow down with time and cease when the material starts to fall back. The falling material travels along almost straight lines in the original direction of ascent, showing no transverse motions. These observations are consistent with the scenario that the jet involves untwisting helical threads, which rotate about the axis of a single large cylinder and shed magnetic helicity into the upper atmosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

Numerical investigation of initial condition effects on Rayleigh-Taylor instability with acceleration reversals

The influence of initial conditions on miscible incompressible baroclinically driven Rayleigh-Taylor instability undergoing nonuniform acceleration is explored computationally using an implicit large eddy simulation (ILES) technique. We consider here the particular case of evolution during multiple reversals of acceleration direction, where the flow is alternately statically stable or unstable. In the unstable phase, the flow is driven by the baroclinic release of potential energy, whereas in the stable phase, work is done against the density stratification with the energy exchange taking place by wavelike mechanisms. These dynamics are fundamentally different; here, we track the evolution of volume-averaged turbulent statistics that are most sensitive to changes in the distribution of spectral power and bandwidth of the initial conditions as the flow alternates between dynamical regimes due to acceleration reversal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulation of Photovoltaic Power Output for the Salt River Project Integration Study

One year of power output was simulated at one-minute intervals for each of fourteen hypothetical utility-scale photovoltaic power plants and for the aggregate power output from a large number of distribution-connected photovoltaic systems. For utility-scale plants, the simulation first constructs one-year time series of global horizontal irradiance at one-minute intervals at each plant location, and a performance model translates irradiance and weather information to AC output power. Distribution-connected photovoltaic systems comprise a variety of system configurations: residential-scale rooftop systems at various tilts; commercial-scale flat-roof mounted systems; and commercial-scale ground-mounted tracked systems. For distribution-connected PV systems, the simulation estimates the time series of spatially-averaged irradiance for the region containing the systems, and the performance model is employed to estimate power aggregate power from all systems. The simulation results are validated by comparing statistics for the time series of irradiance with statistics for measured irradiance within the region.

14 SOLAR ENERGY↗

SU-G-JeP1-12: Head-To-Head Performance Characterization of Two Multileaf Collimator Tracking Algorithms for Radiotherapy

Purpose: Multi-leaf collimator (MLC) tracking is being clinically pioneered to continuously compensate for thoracic and abdominal motion during radiotherapy. The purpose of this work is to characterize the performance of two MLC tracking algorithms for cancer radiotherapy, based on a direct optimization and a piecewise leaf fitting approach respectively. Methods: To test the algorithms, both physical and in silico experiments were performed. Previously published high and low modulation VMAT plans for lung and prostate cancer cases were used along with eight patient-measured organ-specific trajectories. For both MLC tracking algorithm, the plans were run with their corresponding patient trajectories. The physical experiments were performed on a Trilogy Varian linac and a programmable phantom (HexaMotion platform). For each MLC tracking algorithm, plan and patient trajectory, the tracking accuracy was quantified as the difference in aperture area between ideal and fitted MLC. To compare algorithms, the average cumulative tracking error area for each experiment was calculated. The two-sample Kolmogorov-Smirnov (KS) test was used to evaluate the cumulative tracking errors between algorithms. Results: Comparison of tracking errors for the physical and in silico experiments showed minor differences between the two algorithms. The KS D-statistics for the physical experiments were below 0.05 denoting no significant differences between the two distributions pattern and the average error area (direct optimization/piecewise leaf-fitting) were comparable (66.64 cm2/65.65 cm2). For the in silico experiments, the KS D-statistics were below 0.05 and the average errors area were also equivalent (49.38 cm2/48.98 cm2). Conclusion: The comparison between the two leaf fittings algorithms demonstrated no significant differences in tracking errors, neither in a clinically realistic environment nor in silico. The similarities in the two independent algorithms give confidence in the use of either algorithm for clinical implementation.

60 APPLIED LIFE SCIENCES↗

Analysis of Prostate Patient Setup and Tracking Data: Potential Intervention Strategies

Purpose: To evaluate the setup, interfraction, and intrafraction organ motion error distributions and simulate intrafraction intervention strategies for prostate radiotherapy. Methods and Materials: A total of 17 patients underwent treatment setup and were monitored using the Calypso system during radiotherapy. On average, the prostate tracking measurements were performed for 8 min/fraction for 28 fractions for each patient. For both patient couch shift data and intrafraction organ motion data, the systematic and random errors were obtained from the patient population. The planning target volume margins were calculated using the van Herk formula. Two intervention strategies were simulated using the tracking data: the deviation threshold and period. The related planning target volume margins, time costs, and prostate position 'fluctuation' were presented. Results: The required treatment margin for the left-right, superoinferior, and anteroposterior axes was 8.4, 10.8, and 14.7 mm for skin mark-only setup and 1.3, 2.3, and 2.8 mm using the on-line setup correction, respectively. Prostate motion significantly correlated among the superoinferior and anteroposterior directions. Of the 17 patients, 14 had prostate motion within 5 mm of the initial setup position for {>=}91.6% of the total tracking time. The treatment margin decreased to 1.1, 1.8, and 2.3 mm with a 3-mm threshold correction and to 0.5, 1.0, and 1.5 mm with an every-2-min correction in the left-right, superoinferior, and anteroposterior directions, respectively. The periodic corrections significantly increase the treatment time and increased the number of instances when the setup correction was made during transient excursions. Conclusions: The residual systematic and random error due to intrafraction prostate motion is small after on-line setup correction. Threshold-based and time-based intervention strategies both reduced the planning target volume margins. The time-based strategies increased the treatment time and the in-fraction position fluctuation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diffusion–convection model of runaway electrons due to large magnetohydrodynamic perturbations in post-thermal quench plasmas

Systematic test particle tracing simulations for runaway electrons (REs) are performed for six post-thermal quench equilibria from DIII-D and ITER, where large scale, kink-like n = 1 (n is the toroidal mode number) magnetohydrodynamic (MHD) instabilities are found. The modeled particle guiding center orbits allow extraction of the effective diffusion–convection coefficients of REs in the presence of large three-dimensional (3D) perturbations up to 10% of the equilibrium toroidal field. With a fixed spatial distribution of the field perturbation, the RE transport coefficients along the plasma radial coordinate track reasonably well with the surface-averaged perturbation level. A substantial variation in the value of the transport coefficients—by three orders of magnitude in most cases, however, occurs with varying launching location of REs along the plasma radius. Large 3D perturbations almost always lead to comparable diffusion and convection processes, meaning that diffusion alone is insufficient to describe the particle motion. At lower (but still high) level of perturbation, the RE convection is found to be dominant over diffusion. A similar observation is made when the perturbation is too strong. In the presence of large perturbation, the dependence of the RE transport on the particle energy is sensitive to the spatial distribution of the perturbation. Based on numerically obtained RE transport coefficients, an analytic fitting model is proposed to quantify the particle diffusion and convection processes due to large MHD events in post-thermal quench plasmas. The model is shown to reasonably well reproduce the direct test particle tracing results for the RE loss fraction and can, thus, be useful for incorporating into other kinetic RE codes in order to simulate the RE beam evolution in the presence of large 3D perturbations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distributed Optimal Power Management for Battery Energy Storage Systems: A Novel Accelerated Tracking ADMM Approach

Optimal power management (OPM) is critical for large-scale battery energy storage systems. Today’s methods often require formidable computational effort due to the design based on centralized numerical optimization. Thus, this paper investigates computationally distributed OPM where the agents based on the cells communicate over a network to cooperatively solve the OPM problem. We propose an accelerated tracking alternating direction method of multipliers (ADMM) algorithm to solve the distributed OPM. The proposed algorithm embeds dynamic average consensus and Nesterov’s acceleration technique in the ADMM algorithm. Not only is the proposed algorithm fully distributed without a need for fusion or aggregating nodes, but it also accelerates convergence. The paper formulates the OPM in a model predictive control framework where it seeks to regulate the charging/discharging power of each battery cell to minimize the total power losses and promote balanced use of the constituent cells while complying with the safety constraints. The paper provides ample simulation results to demonstrate the effectiveness and advantages of the proposed distributed OPM in terms of computation and convergence.

Farakhor, Amir↗

An airfoil-based synthetic actuator disk model for wind turbine aerodynamic and structural analysis

Here, this study introduces an airfoil-based refinement technique to enhance the Actuator Disk Model (ADM) for improved wind turbine aerodynamic load prediction and structural simulation in conjunction with Large Eddy Simulations of the wind flow. While ADM offers higher computational efficiency than the more detailed but resource-intensive Actuator Line Model (ALM), it traditionally lacks the resolution needed to capture the localized blade forces accurately. To address this limitation, we introduce a refinement technique that uses airfoil-specific data and employs interpolation-based grid point refinement, achieving ALM-comparable accuracy while preserving ADM's efficiency. Unlike conventional ADM that provides only rotor-disk averaged forces, our synthetic method tracks transient aerodynamic load variations over multiple blade revolutions, allowing us to calculate the distributions of maximum and minimum loads during typical cycles. Applied to the NREL 5 MW reference turbine, our enhanced ADM accurately predicts key aerodynamic parameters (angle of attack, axial velocity, lift, drag, axial and tangential forces along the blades) as well as structural responses (blade tip deflection, maximum stress, and stress concentration). Our results show that the tip deflection ranges from 2.33m (3.69 % of blade length) to 4.28m (6.79 %), with maximum stress concentration occurring near the blade root. This research demonstrates that a refined synthetic ADM approach can serve as a computationally efficient alternative for both aerodynamic analysis and structural simulation of wind turbine blades subjected to realistic wind fields.

17 WIND ENERGY↗

Electromagnetic Detection and Real-Time DMLC Adaptation to Target Rotation During Radiotherapy

Purpose: Intrafraction rotation of more than 45 Degree-Sign and 25 Degree-Sign has been observed for lung and prostate tumors, respectively. Such rotation is not routinely adapted to during current radiotherapy, which may compromise tumor dose coverage. The aim of the study was to investigate the geometric and dosimetric performance of an electromagnetically guided real-time dynamic multileaf collimator (DMLC) tracking system to adapt to intrafractional tumor rotation. Materials/Methods: Target rotation was provided by changing the treatment couch angle. The target rotation was measured by a research Calypso system integrated with a real-time DMLC tracking system employed on a Varian linac. The geometric beam-target rotational alignment difference was measured using electronic portal images. The dosimetric accuracy was quantified using a two-dimensional ion chamber array. For each beam, the following five delivery modes were tested: 1) nonrotated target (reference); 2) fixed rotated target with tracking; 3) fixed rotated target without tracking; 4) actively rotating target with tracking; and 5) actively rotating target without tracking. Dosimetric performance of the latter four modes was measured and compared to the reference dose distribution using a 3 mm/3% {gamma}-test. Results: Geometrically, the beam-target rotational alignment difference was 0.3 Degree-Sign {+-} 0.6 Degree-Sign for fixed rotation and 0.3 Degree-Sign {+-} 1.3 Degree-Sign for active rotation. Dosimetrically, the average failure rate for the {gamma}-test for a fixed rotated target was 11% with tracking and 36% without tracking. The average failure rate for an actively rotating target was 9% with tracking and 35% without tracking. Conclusions: For the first time, real-time target rotation has been accurately detected and adapted to during radiation delivery via DMLC tracking. The beam-target rotational alignment difference was mostly within 1 Degree-Sign . Dose distributions to fixed and actively rotating targets with DMLC tracking were significantly superior to those without tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗