Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed control and estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of a Kalman filter estimator for simulation and control of particulate matter distribution of a diesel catalyzed particulate filter

The knowledge of the temperature and particulate matter mass distribution is essential for monitoring the performance and durability of a catalyzed particulate filter. A catalyzed particulate filter model was developed, and it showed capability to accurately predict temperature and particulate matter mass distribution and pressure drop across the catalyzed particulate filter. However, the high-fidelity model is computationally demanding. Therefore, a reduced order multi-zone particulate filter model was developed to reduce computational complexity with an acceptable level of accuracy. In order to develop a reduced order model, a parametric study was carried out to determine the number of zones necessary for aftertreatment control applications. The catalyzed particulate filter model was further reduced by carrying out a sensitivity study of the selected model assumptions. The reduced order multi-zone particulate filter model with 5 × 5 zones was selected to develop a catalyzed particulate filter state estimator considering its computational time and accuracy. Next, a Kalman filter–based catalyzed particulate filter estimator was developed to estimate unknown states of the catalyzed particulate filter such as temperature and particulate matter mass distribution and pressure drop (Δ P) using the sensor inputs to the engine electronic control unit and the reduced order multi-zone particulate filter model. A diesel oxidation catalyst estimator was also integrated with the catalyzed particulate filter estimator in order to provide estimates of diesel oxidation catalyst outlet concentrations of NO 2 and hydrocarbons and inlet temperature for the catalyzed particulate filter estimator. The combined diesel oxidation catalyst–catalyzed particulate filter estimator was validated for an active regeneration experiment. The validation results for catalyzed particulate filter temperature distribution showed that the root mean square temperature error by using the diesel oxidation catalyst–catalyzed particulate filter estimator is within 3.2 °C compared to the experimental data. Similarly, the Δ P estimator closely simulated the measured total Δ P and the estimated cake pressure drop error is within 0.2 kPa compared to the high-fidelity catalyzed particulate filter model.

Engineering↗

Consensus-Based Approach for Active Power Control and Reserve Estimation in Distributed PV Systems

With the increased adoption of distributed energy resources (DER), they are expected to contribute to power system reliability services and enhance power system stability. This paper presents a distributed consensus control approach for the real-time active power reserve estimation and power management in distributed PV (photovoltaic) systems. The proposed method estimates the cumulative active power reserve from numerous PV generators using only the sparse communication network for a DER aggregator to provide active power regulation services. The real-time active power reserve estimation using the proposed approach can be used by DER aggregators to manage curtailment in distributed PV systems to maintain stipulated reserves and further to provide power system frequency regulation. Using the proposed approach, the DER aggregator only requires measurements at the feeder substation and it does not require information from individual DER units, thereby improving system resiliency. The proposed distributed consensus control method is validated on IEEE 123 testbed using PSCAD simulations.

active power reserve↗

Consensus-Based Approach for Active Power Control and Reserve Estimation in Distributed PV Systems: Preprint

With the increased adoption of distributed energy resources (DER), they are expected to contribute to power system reliability services and enhance power system stability. This paper presents a distributed consensus control approach for the real-time active power reserve estimation and power management in distributed PV (photovoltaic) systems. The proposed method estimates the cumulative active power reserve from numerous PV generators using only the sparse communication network for a DER aggregator to provide active power regulation services. The real-time active power reserve estimation using the proposed approach can be used by DER aggregators to manage curtailment in distributed PV systems to maintain stipulated reserves and further to provide power system frequency regulation. Using the proposed approach, the DER aggregator only requires measurements at the feeder substation and it does not require information from individual DER units, thereby improving system resiliency. The proposed distributed consensus control method is validated on IEEE 123 testbed using PSCAD simulations.

active power reserve↗

Data-Driven Mean-Corrected Recursive Estimation-Based Optimal DER Dispatch for Distribution System Voltage Control

Recent advances in smart inverters offer opportunities to mitigate adverse grid impacts caused by high penetrations of distributed photovoltaics (PV) in distribution grids, such as voltage violations. Here, this paper proposes a novel measurement-driven optimal power flow (OPF)-based distributed energy resource management system (DERMS) voltage regulation via recursive sensitivity estimation informed coordinated control of distributed PV inverters. The proposed approach leverages available grid and controllable DER measurements, eliminating reliance on system model information while being adaptive and robust to volatile operating conditions. A mean-corrected recursive ridge regression (MCRRR) algorithm is proposed for sensitivity estimation, continuously refining the sensitivity model through a closed-form solution. It effectively manages varying grid operating conditions, such as changes in power injections and topology reconfiguration, to facilitate a time-varying update of the Load Sensitivity Factors (LSF). The proposed approach is formulated as a linear programming (LP) problem and is thus scalable to larger-scale distribution systems. Its effectiveness and efficiency are demonstrated on a realistic distribution feeder with high PV penetrations in Southern California, USA.

14 SOLAR ENERGY↗

OEDI—Solar Grid Integration Data and Analytics Library

As a part of the Open Energy Data Initiative, this effort aims to develop and demonstrate novel distribution state estimation, control optimization, and transient analysis as well as provide access to data, data integration, and mapping information. More specifically, the focus of the effort will be on physics-based distribution system state estimation, hybrid (physics-based and machine learning) distribution optimal power flow, and event detection/analysis for solar integration and analytics. This work will enable reproducible, robust, replicable, and generalizable R&D in simulation and emulation of solar system integration. These test models and datasets will provide an integrated library for developing and testing power system operation technologies. To make the library user-friendly, this project will provide data curation tools such as data translators, mapping scripts and APIs, database schemas and metadata, interfaces and user dashboard, source code for the reference algorithms, description of the use-cases/scenarios, and comprehensive information on all the assumptions.

14 SOLAR ENERGY↗

Optimal Power Flow With State Estimation in the Loop for Distribution Networks

Here in this article, we propose a framework for running optimal control-estimation synthesis in distribution networks. Our approach combines a primal-dual gradient-based optimal power flow solver with a state estimation feedback loop based on a limited set of sensors for system monitoring, instead of assuming exact knowledge of all states. The estimation algorithm reduces uncertainty on unmeasured grid states based on certain online state measurements and noisy "pseudomeasurements." We analyze the convergence of the proposed algorithm and quantify the statistical estimation errors based on a weighted least-squares estimator. The numerical results on a 4521-node network demonstrate that this approach can scale to extremely large networks and provide robustness to both large pseudomeasurement variability and inherent sensor measurement noise.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantifying Rates of Erosion Using Historical Aerial Photos - 19478

Erosion can play an important role in the fate and transport of waste at sites where disposal of long-lived waste is anticipated. The statistical characterization of key processes related to erosion is essential to the understanding of site stability through time. In this work multi-temporal historical aerial images are analyzed in conjunction with orthophotography and Lidar data to develop probability distributions for variables representing important erosion processes. Scans of photographic negatives were obtained for multiple photographs and several negatives were scanned with a calibrated photogrammetric scanner by Geomni (formerly Blue Skies Consulting) in Belen, New Mexico. Other negatives were provided by USDA or scanned on a high-resolution, large format media scanner in the United States National Archives Cartographic Research Room, College Park, Maryland (1939). An additional set of aerial photographs was obtained from the USGS EROS Data Center web site. For other years, photographic prints were available for aerial photography. Several prints were scanned with a large-format media scanner at 1200 dpi. Ground control points for selected digital images used in the stereoscopic analyses were identified in ArcMap. Ground control points were collected by matching features which could be identified in the aerial photography as well as the orthophotography or shaded relief imagery from the Lidar dataset. Such features included fence line intersections, road intersections, railroad bridges, and structures, depending on the age of the photography. Many old fence lines and abandoned roads remained visible in the shaded relief imagery while they were completely obscured by tree canopy in modern photography. Ground control elevations were sampled from the Lidar-based DEM or directly from point clouds. The image coordinates and matching three-dimensional projected coordinates of the ground control points were exported to IDL where parameters for a three-dimensional direct linear transformation (DLT) were obtained. Built-in singular value decomposition routines were used to solve an overdetermined set of equations for the eleven parameters of the DLT for a particular historical photograph. A solution to the DLT parameters was obtained for each historical aerial photograph in which features of interest were identified using the stereoscope. Ultimately, this process resulted in the identification of locations for features like gully heads using both the Lidar dataset and projection of the estimated location from the historical aerial photo under consideration back to the Lidar dataset. The distance between the estimate of the location from the historical image and that of the Lidar dataset was the estimated distance the feature has moved. This distance was then divided by the number of years between the Lidar dataset and the year of the historical aerial image of interest to get a rate of movement through time. This was done for several dozen points on each historical aerial image. There was inevitable uncertainty associated with the estimation of points from the historical aerial imagery. This includes estimation of changes in locations of features like gully heads through time. In this work a method to estimate the uncertainty associated with measurements of locations of features using the stereoscopic analysis is developed and applied. For features with locations in space that do not change (e.g., road intersections, etc.) the difference in measurements of locations from the Lidar dataset and that of the estimate from the historical aerial image provides an observation of the measurement error. These points used to estimate the measurement error are referred to as control points. For each of the historical aerial images, a different measurement error distribution is estimated using control points. These measurement errors are combined with the estimated distances from the stereoscopic analyses to produce distributions of gully retreat rates and hillslope erosion rates used along with output from Erosion Working Group (EWG) Landscape Evolution Models (LEMs) to provide statistical probability distributions for input into the PPA Model. Specifically, gully head retreat rate and gully widening rate were characterized using statistical probability distributions. The central limit theorem was then applied to develop rates that represent long-term averages that are used to inform a PPA Model built in GoldSim. The importance of these rates with respect to characterization of future risk can then assessed using sensitivity analyses. This provides an approach to determine if subsequent reduction of the uncertainty associated with the probability distributions of erosion rates will correspond to meaningful reduction in the estimation of future risk from the site. Ultimately this is a general method that utilizes historical aerial imagery to estimate rates of erosion with uncertainty. This information can be used to inform PPA models to project future risks from a given site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Power distribution estimation method for SMR using ex-core detectors: experimental demonstration by plural control rod patterns at KUCA

The power distribution estimation method based on the ex-core detectors, or PHOEBE, was demonstrated at Kyoto University Critical Assembly, KUCA. Generally, core monitoring systems use in-core neutron detectors. Since inside the core is a harsh environment, the maintainability and reliability of the detectors are deteriorated. On the other hand, the environment outside the core is milder: core monitoring by the ex-core detectors improves the maintainability and reliability especially for small modular reactors and micro-reactors. However, neutron information from the inner region of the core is lost at the ex-core detectors. To recover the information, the authors proposed to utilize the power correlation between the fuel regions. PHOEBE concept was demonstrated at KUCA with distorted power distributions simulated by control rod patterns. The relative power distribution estimated by PHOEBE agreed with that calculated by Monte Carlo simulation code MVP. PHOEBE approximately reproduced the trend of the distorted power distributions calculated by MVP code. By contrast, the case of without power correlation between fuel regions produced significant different power distributions. Therefore, the advantage of considering the power correlation between fuel regions was also demonstrated. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Gradient-Based Multi-Area Distribution System State Estimation

The increasing distributed and renewable energy resources and controllable devices in distribution systems make fast distribution system state estimation (DSSE) crucial in system monitoring and control. We consider a large multi-phase distribution system and formulate DSSE as a weighted least squares (WLS) problem. We divide the large distribution system into smaller areas of subtree structure, and by jointly exploring the linearized power flow model and the network topology, we propose a gradient-based multi-area algorithm to exactly and efficiently solve the WLS problem. The proposed algorithm enables distributed and parallel computation of the state estimation problem without compromising any performance. Numerical results on a 4,521-node test feeder show that the designed algorithm features fast convergence and accurate estimation results. Comparison with traditional Gauss-Newton method shows that the proposed method has much better performance in distribution systems with a limited amount of reliable measurement. The real-time implementation of the algorithm tracks time-varying system states with high accuracy.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Considerations for AMI-Based Operations for Distribution Feeders

More than $5 billion in investments in advanced metering infrastructure (AMI) technologies, AMI deployments, as pervasive secondary network voltage monitoring systems, provide opportunities for utility operations and controls. This paper focuses on the considerations for AMI-based tools and techniques as the industry moves toward operationalizing such large data sets. Phase identification is a first such tool. Numerous distribution network analysis, monitoring, and control applications - including volt/volt-ampere reactive control, state estimation, and distribution automation - require accurate phase connectivity information in the system models. The phase connectivity database maintained by utilities is inaccurate because of a significant amount of missing data, restoration activities, and network reconfiguration. Existing phase identification techniques that estimate phase connectivity work well in distribution feeders that have low or no photovoltaic (PV) generation; however, they fail to identify the phases accurately when considerable PV generation is present. This work addresses the phase identification problem in the presence of high PV generation using statistical analysis methods. Further, insights into the AMI data requirements for this application in terms of data window length and resolution are provided using sensitivity analysis performed on an actual distribution feeder model of San Diego Gas & Electric Company. The results of this study show that the phase connectivity, even in the presence of high PV generation, can be accurately identified using statistical analysis of AMI data of 1 day.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Considerations for AMI-Based Operations for Distribution Feeders: Preprint

More than $5 billion in investments in advanced metering infrastructure (AMI) technologies, AMI deployments, as pervasive secondary network voltage monitoring systems, provide opportunities for utility operations and controls. This paper focuses on the considerations for AMI-based tools and techniques as the industry moves toward operationalizing such large data sets. Phase identification is a first such tool. Numerous distribution network analysis, monitoring, and control applications - including volt/volt-ampere reactive control, state estimation, and distribution automation - require accurate phase connectivity information in the system models. The phase connectivity database maintained by utilities is inaccurate because of a significant amount of missing data, restoration activities, and network reconfiguration. Existing phase identification techniques that estimate phase connectivity work well in distribution feeders that have low or no photovoltaic (PV) generation; however, they fail to identify the phases accurately when considerable PV generation is present. This work addresses the phase identification problem in the presence of high PV generation using statistical analysis methods. Further, insights into the AMI data requirements for this application in terms of data window length and resolution are provided using sensitivity analysis performed on an actual distribution feeder model of San Diego Gas & Electric Company. The results of this study show that the phase connectivity, even in the presence of high PV generation, can be accurately identified using statistical analysis of AMI data of 1 day.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A First-order Prediction-Correction Algorithm for Time-varying (Constrained) Optimization: Preprint

This paper focuses on the design of online algorithms based on prediction-correction steps to track the optimal solution of a time-varying constrained problem. Existing prediction-correction methods have been shown to work well for unconstrained convex problems and for settings where obtaining the inverse of the Hessian of the cost function can be computationally affordable. The prediction-correction algorithm proposed in this paper addresses the limitations of existing methods by tackling constrained problems and by designing a first-order prediction step that relies on the Hessian of the cost function (and do not require the computation of its inverse). Analytical results are established to quantify the tracking error. Numerical simulations corroborate the analytical results and showcase performance and benefits of the algorithms.

97 MATHEMATICS AND COMPUTING↗

Distribution System Behind-the-Meter DERs: Estimation, Uncertainty Quantification, and Control

This paper summarizes the three-year technical activities of the IEEE Task Force (TF) on behind-the-meter (BTM) distributed energy resources (DERs): estimation, uncertainty quantification, and control. The potential grid services from BTM DERs are discussed in detail. The paper also reviews the state-of-the-art for BTM DERs visibility, uncertainty quantification, and, optimization and control. Furthermore, different aspects of the market structures associated with BTM DERs are covered, including emerging market and business models. Finally, needs and recommendations are provided for additional areas such as system protection, computing capabilities, algorithm development, market structure design, cyberinfrastructure and security, and hardware and software developments.

behind-the-meter↗

Fault isolation and fault-tolerant control for Takagi-Sugeno fuzzy time-varying delay stochastic distribution systems

A fault isolation, estimation, and fault-tolerant control (FTC) scheme for nonlinear time-varying delay stochastic distribution control systems was presented in this paper. The Takagi-Sugeno fuzzy model was adopted to approach the nonlinear dynamics of time-varying delay systems. According to the output equivalence principle and Laplace transformation, an augmented state vector was given to solve the time-varying delay problem. When multiple actuator faults and interference occur simultaneously, fault detection, isolation and fault estimation was designed to obtained the fault information. To decouple faults and obtain the value and location information of the fault, the system was separated into two parts through the designed multiple conversion matrices, in which one subsystem was only affected by one actuator fault. This has simplified the design of fault isolation and estimation. A adaptive observer for fault estimation was given. Then, fault information such as the time, location, and size was determined. The observer gain matrices were calculated using linear matrix inequality (LMI). When a fault was detected and diagnosed, a FTC algorithm was devised using the proportional-integral control scheme to compensate the fault as much as possible. It has been shown that even if multiple faults actuator occurred simultaneously, the FTC controller still ensured the output probability density function of the system traced the desired probability density function when a fault occurred. Finally, the expected results were obtained through the simulation example, which confirmed the effectiveness of the method.

42 ENGINEERING↗

Aqueous Bromide Discharges from U.S. Coal-Fired Power Plants: Points of Origin, Concentration Ranges, and Effluent Treatment Costs

Bromide discharges from coal-fired power plants have received increased attention from regulatory bodies due to their contribution to the formation of disinfection byproducts (DBPs) in downstream drinking water treatment plants. Here, this paper characterizes the relative contributions of bromide from coal feedstocks and bromine-based mercury control processes, estimates the distribution of bromide concentrations at 85 active coal-fired power plants across the United States (U.S.) with wet flue gas desulfurization units, and estimates the cost of bromide removal from wastewater discharge using year 2020 data. Bromide discharges are estimated at the plant level using a combination of the reported coal rank and composition combusted, estimates of bromide addition in mercury control techniques under multiple halogen addition scenarios, and the estimated flue gas desulfurization (FGD) wastewater flow rate. The median, simulated plant-level estimation of total FGD wastewater flow is 18.3 gallons/min at a bromide concentration of 319 mg/L, equivalent to ~11.6 tonnes/year of bromide discharges to the environment. Next, we evaluated the expected cost of employing the best available technology (BAT) to control bromide discharges in FGD wastewater to prevent contributions to DBP formation. Treatment would need to remove more than 99.8% of bromide to reach the 0.2 mg/L voluntary incentive program (VIP) limit. The total cost of treatment depends on whether disposal is on- or off-site; the average costs for all plants combined come to an average of $110 million ($95.2/kgal) in 2021 U.S. dollars for on-site disposal, or $134 million ($115/kgal) for off-site disposal.

01 COAL, LIGNITE, AND PEAT↗

Enhanced Tensor Completion Based Approaches for State Estimation in Distribution Systems

Grid state estimation is essential for effective control and management of distribution systems. While weighted least squares has been the conventional method for state estimation, sparsity-aware methods have become popular due to their superior performance with limited data. Matrix completion and compressed sensing-based state estimation approaches exploit the underlying smoothness in the state variables. However, classic matrix completion methods do not take into account the temporal correlation of system states. Compressed sensing methods, on the other hand, require an appropriate choice of sparsifying basis that may not be easy to identify. This paper proposes a blocktensor completion based framework which uses an alternative approach to estimate voltage phasor, power injections and branch currents. This approach utilizes the temporal correlation of the system states in a tensor trace-norm minimization formulation with power flow equations as constraints. Herein, feature scaling is introduced in the problem formulation to benefit from the improved sensitivity of the tensor trace norm to the matrix columns in the scaled unfoldings of the tensor. Weighted tensor norm is utilized to exploit the structures of the different unfoldings of the state measurement tensor to improve the voltage estimation. The estimation accuracy is further improved by alternatively estimating the tensor columns and increasing the available data at each stage in the tensor completion process. The proposed methods are evaluated on the IEEE-33, 37 test systems and a 100- node test system. The proposed methods are shown to provide significant performance gains relative to the classic matrix and tensor completion based approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decentralized State Estimation and Remedial Control Action for Minimum Wind Curtailment Using Distributed Computing Platform

Intermittency of wind energy poses a great challenge for power system operation and control. Wind curtailment might be necessary at the certain operating condition to keep the line flow within the limit. Remedial Action Scheme (RAS) offers quick control action mechanism to keep reliability and security of the power system operation with high wind energy integration. In this paper, a new RAS is developed to maximize the wind energy integration without compromising the security and reliability of the power system based on specific utility requirements. A new Distributed Linear State Estimation (DLSE) is also developed to provide the fast and accurate input data for the proposed RAS. A distributed computational architecture is designed to guarantee the robustness of the cyber system to support RAS and DLSE implementation. The proposed RAS and DLSE is validated using the modified IEEE-118 Bus system. Simulation results demonstrate the satisfactory performance of the DLSE and the effectiveness of RAS. Real-time cyber-physical testbed has been utilized to validate the cyber-resiliency of the developed RAS against computational node failure.

17 WIND ENERGY↗