Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed feedback (DFB) laser”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Application of a diode-laser-based ultraviolet absorption sensor for in situ measurements of atomic mercury in coal-combustion exhaust

A diode-laser-based ultraviolet absorption sensor was successfully demonstrated for both in situ and extractive sampling atomic mercury measurements in a laboratory-scale 29.3 kWt (100 000 BTU/h) coal combustor and in situ measurements in a flow reactor at Texas A&M University. Laser sensor measurements were compared to measurements from a commercial mercury analyzer (CMA). A 375 nm single-mode laser and a 784 nm distributed feedback (DFB) laser are sum-frequency-mixed in a nonlinear {beta}-barium borate crystal to generate a 254 nm beam. By tuning the frequency of the DFB laser, the ultraviolet beam frequency was tuned across the transition frequency of mercury at 253.7 nm. The tuning range was large enough that an off-resonant baseline was clearly visible on both sides of the Hg transition. No pretreatment is required for elemental mercury measurements, and the effects of broadband absorption can be effectively eliminated during data analysis. Extractive sampling was demonstrated to improve the detection limit of the sensor and demonstrate the feasibility of total mercury concentration measurements in the future through extractive sampling. Significant variation in the atomic mercury concentration of coal-combustion exhaust was observed over short time periods during our in situ measurements. The sensor detection limits for in situ and extractive sampling are 0.3 and 0.1 parts per billion over a 1 m path length, respectively. 34 refs., 11 figs., 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

Development of New Optical Sensors for Measurements of Mercury Concentrations, Speciation, and Chemistry

A diode-laser-based ultraviolet absorption sensor for elemental mercury was developed and applied for measurements in a high-temperature flow reactor and in the exhaust stream of a coal-fired combustor. The final version of the sensor incorporates a 375-nm single-mode laser and a 784-nm distributed feedback (DFB) laser. The output of these lasers is sum-frequency mixed in a non-linear beta-barium borate crystal to generate a 254-nm beam. By tuning the frequency of the DFB laser, the ultraviolet beam frequency is tuned across the transition frequency of mercury at 253.7-nm. The tuning range is large enough that an off-resonant baseline was clearly visible on both sides of the Hg transition. Because of this large tuning range, the effects of broadband absorption can be effectively eliminated during data analysis. Broadband absorption is a major concern for lamp-based mercury sensor, and the sample to be monitored must be chemically treated prior to analysis to remove species such as SO{sub 2} that absorb near 253.7 nm. No pretreatment is required when our diode-laser-based sensor is used for elemental mercury measurements. Our laser sensor measurements were compared to measurements from a commercial mercury analyzer (CMA), and were generally in good agreement except that the insitu diode-laser-based sensor measurements tended to give somewhat higher concentrations than the CMA measurements, presumably due to absorption of elemental mercury in the sampling lines needed for the CMA measurements. At Texas A&M University, the homogeneous oxidation of elemental mercury was studied using a high-temperature flow reactor.

01 COAL, LIGNITE, AND PEAT↗

Experimental studies of 1.5 – 1.6 μm high-power single-frequency semiconductor lasers

High-power semiconductor laser systems based on 1.5 – 1.6 μm single-frequency distributed feedback (DFB) lasers with a sidewall Bragg diffraction grating are developed and their current – voltage, light – current, and spectral characteristics are experimentally studied. The characteristics of conventional lasers with a Fabry – Perot cavity and DFB lasers fabricated from one and the same heterostructure are compared. At a pump current not exceeding 700 mA, a conventional laser with a cavity length of 1.6 mm and a mesa-stripe width of 3 μm emits a power no lower than 200 mW versus 150 mW of the DFB laser; both lasers are mounted in a housing 11 mm in diameter. The DFB laser mounted in a butterfly housing emits a power no lower than 100 mW at the exit of the single-mode cable at a pump current not exceeding 500 mA, which, at a 60 % coupling efficiency, corresponds to a power no lower than 165 mW; the side-mode suppression ratio in this case is no lower than 53 dB. It is shown that the wavelength deviation with changing pump current and temperature is almost an order of magnitude lower for the DFB laser than for the conventional laser. (paper)

36 MATERIALS SCIENCE↗

High power surface emitting terahertz laser with hybrid second- and fourth-order Bragg gratings

A surface-emitting distributed feedback (DFB) laser with second-order gratings typically excites an antisymmetric mode that has low radiative efficiency and a double-lobed far-field beam. The radiative efficiency could be increased by using curved and chirped gratings for infrared diode lasers, plasmon-assisted mode selection for mid-infrared quantum cascade lasers (QCLs), and graded photonic structures for terahertz QCLs. Here, we demonstrate a new hybrid grating scheme that uses a superposition of second and fourth-order Bragg gratings that excite a symmetric mode with much greater radiative efficiency. The scheme is implemented for terahertz QCLs with metallic waveguides. Peak power output of 170 mW with a slope-efficiency of 993 mW A -1 is detected with robust single-mode single-lobed emission for a 3.4 THz QCL operating at 62 K. Finally, the hybrid grating scheme is arguably simpler to implement than aforementioned DFB schemes and could be used to increase power output for surface-emitting DFB lasers at any wavelength.

36 MATERIALS SCIENCE↗

Publisher Correction: High power surface emitting terahertz laser with hybrid second- and fourth-order Bragg gratings

A surface-emitting distributed feedback (DFB) laser with second-order gratings typically excites an antisymmetric mode that has low radiative efficiency and a double-lobed far-field beam. The radiative efficiency could be increased by using curved and chirped gratings for infrared diode lasers, plasmon-assisted mode selection for mid-infrared quantum cascade lasers (QCLs), and graded photonic structures for terahertz QCLs. Here, we demonstrate a new hybrid grating scheme that uses a superposition of second and fourth-order Bragg gratings that excite a symmetric mode with much greater radiative efficiency. The scheme is implemented for terahertz QCLs with metallic waveguides. Peak power output of 70 mW with a slope-efficiency of 993 mW A -1 is detected with robust single-mode single-lobed emission for a 3.4 THz QCL operating at 62 K. The hybrid grating scheme is arguably simpler to implement than aforementioned DFB schemes and could be used to increase power output for surface-emitting DFB lasers at any wavelength.

Jin, Yuan↗

Mid Infra-Red Laser Sensor for Continuous Sulfur Trioxide Monitoring to Improve Coal-Fired Power Plant Performance during Flexible Operations

During the course of this project, we performed exhaustive research and development of SO3/H2SO4 sensing technology for coal-fired power plant applications (Figure 1). The development culminated in a successful field campaign of a prototype continuous real-time H2SO4 monitor at a coal-fired power plant (TRL 6) accomplishing the primary goal of the project. The developed sensors utilize tunable laser absorption spectroscopy (TLAS) operating in the mid-infrared (Mid-IR) wavelength region, which is the so-called “molecular fingerprint” region. Systems operating in the Mid-IR have orders of magnitude more sensitivity than systems operating at shorter wavelengths, such as near-infrared (NIR). However, NIR systems are more widespread due to more mature supporting technology (e.g., fiber optics, optical components, etc.). In this project, we not only produced a specific Mid-IR sensor, we also advanced Mid-IR sensor technology in general through the development and demonstration of such supporting technology. In this project, we also developed proprietary broad tuning lasers enabling the ability to effectively measure SO3, H2SO4, H2O, and SO2. Different molecular species have unique spectral signatures that can be probed with lasers operating at different wavelengths. Standard TLAS uses relatively narrow wavelength tuning distributed feedback (DFB) lasers, which can typically only target a single species with narrow features, and are not appropriate for species with broad features, such as SO3 or H2SO4. In contrast, by developing unique, broad-tuning laser technology, we were able to measure these species, as well as SO2 and H2O simultaneously. Furthermore, to enable real-time analysis at a power plant, we modified a commercially available heated gas cell to operate in the Mid-IR wavelength range and fiber coupled the lasers to enable remote delivery of the beams. To generate reference data (library spectra), our collaborators at the University of California Irvine (UCI) developed a catalytic SO3 generation facility. It is worth mentioning that representative H2SO4 and SO3 Mid-IR spectra are not a part of any publicly available database and the data generated under this project is a valuable resource in and of itself. In addition, based on the UCI study we determined that detection of SO3 is complicated by the very strong SO2 absorption. For that reason, we concentrated on H2SO4 detection. Since SO3 and H2SO4 exist in a flue gas in a state of equilibrium, which depends on temperature and humidity, by measuring water concentration and controlling the temperature of the gas cell, we developed an approach to determine SO3 concentration from the H2SO4 measurement. During the development phase of the project, we performed three testing campaigns at our collaborator’s FERCo flue gas facility with conditions representative of the coal-fired power plant (~ 40ppm SO3, 1700ppm to 2800 ppm SO2, 10% water) with the exception of particulate matter. After three test campaigns at FERCo we performed field testing at Harrison Power Station. The final system was mounted on a duct and measured H2SO4, SO2 and water. The tests were highly successful with a demonstrated real-time H2SO4 precision of 1 ppm with a 1 second update. Our collaborators at EPRI conducted an industry survey and determined that there is a very high interest for the SO3/H2SO4 monitoring in the power generation industry as well as in heavy industries in general. Furthermore, work performed by OptoKnowledge beyond the scope of this project under a synergistic DOE SBIR determined another approach to SO3 detection. We applied for Phase II on this SBIR for development a of versatile SO3/H2SO4 sensor but were not selected. We are currently looking for another opportunity to leverage all the technological advancements produced by this project including but not limited to the flue gas facility at UCI, the hardware and software developed, and relationships with FERCo, EPRI CEMTEK, and Harrison Station.

01 COAL, LIGNITE, AND PEAT↗

High-coupling distributed feedback lasers for the 1.55 μm spectral region

A technique for the development of high-coupling distributed-feedback (DFB) lasers for the 1.55 μm spectral region is described. The lasers demonstrate stable single-frequency generation in a broad temperature range with a maximum side-mode suppression ratio of more than 30 dB. (letters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

2 {mu}m laterally coupled distributed-feedback GaSb-based metamorphic laser grown on a GaAs substrate

We report a type-I GaSb-based laterally coupled distributed-feedback (DFB) laser grown on a GaAs substrate operating continuous wave at room temperature. The laser structure was designed to operate near a wavelength of 2 {mu}m and was grown metamorphically with solid-source molecular beam epitaxy. The device was fabricated using a 6th-order deep etch grating structure as part of the sidewalls of the narrow ridge waveguide. The DFB laser emits total output power of up to 40 mW in a single longitudinal mode operation at a heat-sink temperature of 20 Degree-Sign C.

36 MATERIALS SCIENCE↗

Output characteristics of organic distributed feedback lasers with varying grating heights

In this study, we examine the influence of the corrugation height of surface relief gratings on the output characteristics of organic distributed feedback (DFB) lasers. A series of surface relief gratings with a constant corrugation period (410 nm) and variable corrugation heights ranging from 20 and 80 nm are fabricated by the illumination of a new developed photosensitive azobenzene containing material with an interference pattern. A blend of poly[(9,9-dioctylfluorenyl-2,7-diyl)-co-(1,4-benzo(2,1′,3)-thiadiazol)] and poly[2-methoxy-5-(2′-ethyl-hexyloxy)-1,4-phenylene vinylene] is used as organic laser active material which is deposited by spin-coating onto the grating array. The investigation of the laser output characteristics reveals an increase of the slope efficiency by a factor of 4 from 0.8% to 3.7% due to an increase of the grating height. The laser threshold decreases only slightly from 8.5 μJ/cm{sup 2} to 6.0 μJ/cm{sup 2} with increasing corrugation height. We interpret this as a result of the change of coupling between light mode and grating. The study helps to relate this to loss mechanisms of the DFB lasing process. This enables a further optimization of the DFB laser design.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Combined TDLAS and chemiluminescence imaging in a flat flame burner operated with NH3/H2 blends

Ammonia is viewed as a viable hydrogen carrier due to favorable storage and transport characteristics. While it can be re-converted to hydrogen at point-of-use via thermal catalytic cracking, direct utilization in combustion systems can result in reduced costs and improved efficiency. A major barrier to this approach is the low flammability and potential for high nitrogen oxide emissions, driven by fuel-bound nitrogen and complex kinetic pathways. While a number of kinetic mechanisms currently exist for simulating ammonia combustion, a major need continues to be direct information about species profiles in easy-to-model systems capable of isolating chemical kinetics from multi-dimensional fluid dynamic effects. This paper reports on recent species measurements made in a flat flame burner using a combined tunable-diode-laser-absorption-spectroscopy (TDLAS) and chemiluminescence imaging approach. Three flame conditions were included representative of NH3/H2 blends, partially cracked NH3 (inc. N2), and 100% NH3 with enhanced air (30% oxygen). Two NIR distributed feedback (DFB) laser diodes were used to determine H2O concentration and temperature (via ratio thermometry) at various radial and axial positions, after which an inverse Abel transform was used to infer centerline values. Companion images were collected using a Princeton Instrument PI-MAX intensified camera equipped with a 105mm UV lens and multiple filter sets targeting OH*, NH*, and NH2* emission. Results were compared to companion Cantera burner-stabilized flame simulations using various kinetic mechanisms. A recent mechanism including excited species chemistry was also included, to investigate whether excited and ground state profiles exhibit significant differences.

ammonia combustion↗

Tunable diode laser absorption spectroscopy-based tomography system for on-line monitoring of two-dimensional distributions of temperature and H{sub 2}O mole fraction

To monitor two-dimensional (2D) distributions of temperature and H{sub 2}O mole fraction, an on-line tomography system based on tunable diode laser absorption spectroscopy (TDLAS) was developed. To the best of the authors’ knowledge, this is the first report on a multi-view TDLAS-based system for simultaneous tomographic visualization of temperature and H{sub 2}O mole fraction in real time. The system consists of two distributed feedback (DFB) laser diodes, a tomographic sensor, electronic circuits, and a computer. The central frequencies of the two DFB laser diodes are at 7444.36 cm{sup −1} (1343.3 nm) and 7185.6 cm{sup −1} (1391.67 nm), respectively. The tomographic sensor is used to generate fan-beam illumination from five views and to produce 60 ray measurements. The electronic circuits not only provide stable temperature and precise current controlling signals for the laser diodes but also can accurately sample the transmitted laser intensities and extract integrated absorbances in real time. Finally, the integrated absorbances are transferred to the computer, in which the 2D distributions of temperature and H{sub 2}O mole fraction are reconstructed by using a modified Landweber algorithm. In the experiments, the TDLAS-based tomography system was validated by using asymmetric premixed flames with fixed and time-varying equivalent ratios, respectively. The results demonstrate that the system is able to reconstruct the profiles of the 2D distributions of temperature and H{sub 2}O mole fraction of the flame and effectively capture the dynamics of the combustion process, which exhibits good potential for flame monitoring and on-line combustion diagnosis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Frequency combs in optically injected terahertz ring quantum cascade lasers

Quantum cascade lasers (QCLs) have emerged as promising candidates for generating chip-scale frequency combs in mid-infrared and terahertz wavelengths. In this work, we demonstrate frequency comb formation in ring terahertz QCLs using the injection of light from a distributed feedback (DFB) laser. The DFB design frequency is chosen to match the modes of the ring cavity (near 3.3 THz), and light from the DFB is injected into the ring QCL via a bus waveguide. By controlling the power and frequency of the optical injection, we show that combs can be selectively formed and controlled in the ring cavity. Numerical modeling suggests that this comb is primarily frequency-modulated in character, with the injection serving to trigger comb formation. We also show that the ring can be used as a filter to control the output of the DFB QCL, potentially being of interest in terahertz photonic integrated circuits. Our work demonstrates that waveguide couplers are a compelling approach for injecting and extracting radiation from ring terahertz combs and offer exciting possibilities for the generation of new comb states in terahertz, such as frequency-modulated waves, solitons, and more.

47 OTHER INSTRUMENTATION↗

Simulation Analysis of Mode Hopping Impacts on OFDR Sensing Performance

This article examines the impacts of mode hopping on the sensing performance of optical frequency domain reflectometry (OFDR) and explores the potential for developing economical OFDR interrogators employing low-cost distributed feedback (DFB) lasers. By conducting numerical simulations, this study reveals that mode hopping has minimal effects on distance sensing measurements in free space due to the limited duration of beat interference signal at the incorrect frequency within the coherence length. Additionally, the simulations indicate that mode hopping only slightly affects the distributed strain sensing of OFDR, resulting in an error range of less than ±1µε when 100µε is applied to the sensing fiber. These findings highlight the potential of using low-cost DFB lasers with a 1-nm wavelength sweep range and a 1-MHz linewidth as tunable laser sources in OFDR while maintaining reliable and accurate sensing performance.

Wang, Qirui (ORCID:0000000336532984)↗

Phase-shifted Bragg gratings in a foundry silicon nitride platform

Bragg gratings are key optical elements for applications in communications, sensing, and lasers. Phase-shifted Bragg gratings are a special case where the simple periodic structure is altered to allow a narrow spectral passband within the optical bandgap. Here, we demonstrate phase-shifted silicon nitride gratings fabricated using 193 nm deep ultraviolet lithography (DUV) on the AIM Photonics 300 mm silicon photonics foundry line. We measure the grating properties and verify the results with a transfer-matrix method (TMM) model. The standard grating expressions for extracting the coupling coefficient κ and bandwidth do not apply and are updated to account for the phase shift. These results inform future designs for on-chip grating filters and distributed feedback (DFB) lasers.

Husko, Chad (ORCID:0000000271252518)↗

Monolithically integrated mid-infrared sensor using narrow mode operation and temperature feedback

A method to improve the sensitivity and selectivity of a monolithically integrated mid-infrared sensor using a distributed feedback laser (DFB) is presented in this paper. The sensor is based on a quantum cascade laser/detector system built from the same epitaxial structure and with the same fabrication approach. The devices are connected via a dielectric-loaded surface plasmon polariton waveguide with a twofold function: it provides high light coupling efficiency and a strong interaction of the light with the environment (e.g., a surrounding fluid). The weakly coupled DFB quantum cascade laser emits narrow mode light with a FWHM of 2 cm{sup −1} at 1586 cm{sup −1}. The room temperature laser threshold current density is 3 kA∕cm{sup 2} and a pulsed output power of around 200 mW was measured. With the superior laser noise performance, due to narrow mode emission and the compensation of thermal fluctuations, the lower limit of detection was expanded by one order of magnitude to the 10 ppm range.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated tuning of a ring-assisted MZI-based interleaver for Kerr frequency combs

We demonstrate a compact ring-assisted Mach–Zehnder interferometer (RAMZI)-based silicon photonic interleaver with a 400 GHz free spectral range (FSR), featuring flat passbands exceeding a spectral range of 50 nm. Additionally, we introduce a novel, to the best of our knowledge, add-on structure and tuning method enabling automated compensation for fabrication imperfections, precise shaping of the RAMZI flat-top passbands, and alignment with Kerr comb lines. Experimental results have shown successful interleaving of eight channels of distributed-feedback (DFB) lasers as well as a 200 GHz Kerr comb, both achieving an extinction ratio of approximately 20 dB.

Wang, Songli (ORCID:0009000626380795)↗

Development of a 1 x N Fiber Optic Sensor Array for Carbon Sequestration Site Monitoring

A fiber sensor array for sub-surface CO 2 concentrations measurements was developed for monitoring geologic carbon sequestration sites. The fiber sensor array uses a single temperature tunable distributed feedback (DFB) laser operating with a nominal wavelength of 2.004 μm. Light from this DFB laser is direct to one of the 4 probes via an in-line 1 x 4 fiber optic switch. Each of the 4 probes are buried and allow the sub-surface CO 2 to enter the probe through Millipore filters that allow the soil gas to enter the probe but keeps out the soil and water. Light from the DFB laser interacts with the CO 2 before it is directed back through the in-line fiber optic switch. The DFB laser is tuned across two CO 2 absorption features where a transmission measurement is made allowing the CO 2 concentration to be retrieved. The fiber optic switch then directs the light to the next probe where this process is repeated allowing sub-surface CO 2 concentration measurements at each of the probes to be made as a function of time. The fiber sensor array was deployed for fifty-eight days beginning June 19, 2012 at the Zero Emission Research Technology (ZERT) field site where sub-surface CO 2 concentrations were monitored. Background measurements indicate the fiber sensor array can monitor background levels as low as 1,000 parts per million (ppm). A thirty four day sub-surface release of 0.15 tones CO 2 /day began on July 10, 2012. The elevated subsurface CO 2 concentration was easily detected by each of the four probes with values ranging to over 60,000 ppm, a factor of greater than 6 higher than background measurements. The fiber sensor array was also deploy at the Big Sky Carbon Sequestration Partnership (BSCSP) site in north-central Montana between July 9th and August 7th, 2013 where background measurements were made in a remote sequestration site with minimal infrastructure. The project provided opportunities for two graduate students to participate in research directly related to geologic carbon sequestration. Furthermore, commercialization of the technology developed is being pursued with five different companies via the Department of energy SBIR/STTR program

47 OTHER INSTRUMENTATION↗