SEARCH · Search NASA
Results for “distributed feedback devices”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Real time feedback-based optimization of distributed energy resources
An example device includes a processor configured to receive a plurality of voltage values representing respective voltage magnitudes at voltage nodes in a first portion of a power system and determine, for each voltage node, a respective value of first and second voltage-constraint coefficients. The processor is also configured to receive a power value corresponding to a connection point of the first portion of the power system with a second portion of the power system and determine for the connection point, a respective value of first and second power-constraint coefficients. The processor is also configured to cause at least one energy resource connected to the first portion of the power system to modify an output power of the at least one energy resource based on the value of the first and second voltage-constraint coefficients for each voltage node and the value of the first and second power-constraint coefficients.
Real time feedback-based optimization of distributed energy resources
An example device includes a processor configured to receive a plurality of voltage values representing respective voltage magnitudes at voltage nodes in a first portion of a power system and determine, for each voltage node, a respective value of first and second voltage-constraint coefficients. The processor is also configured to receive a power value corresponding to a connection point of the first portion of the power system with a second portion of the power system and determine for the connection point, a respective value of first and second power-constraint coefficients. The processor is also configured to cause at least one energy resource connected to the first portion of the power system to modify an output power of the at least one energy resource based on the value of the first and second voltage-constraint coefficients for each voltage node and the value of the first and second power-constraint coefficients.
Faster-than-real-time Simulation with Demonstration for Resilient DER Integration
The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.
Feedback Control Strategy for Transient Stability Application
Power systems are subjected to a wide range of disturbances during daily operations. Severe disturbances, such as a loss of a large generator, a three-phase bolted fault on a generator bus, or a loss of a transmission line, can lead to the loss of synchronism of a generator or group of generators. The ability of a power system to maintain synchronism during the few seconds after being subjected to a severe disturbance is known as transient stability. Most of the modern methods of controlling transient stability involve special protection schemes or remedial action schemes. These special protection schemes sense predetermined system conditions and take corrective actions, such as generator tripping or generation re-dispatch, in real time to maintain transient stability. Another method is the use of a real-time feedback control system to modulate the output of an actuator in response to a signal. This paper provides a fundamental evaluation of the use of feedback control strategies to improve transient stability in a power system. An optimal feedback control strategy that modulates the real power injected and absorbed by distributed energy-storage devices is proposed. Its performance is evaluated on a four-machine power system and on a 34-machine reduced-order model of the Western North American Power System. The result shows that the feedback control strategy can increase the critical fault clearing time by 60%, thereby improving the transient stability of the power system.
Thin film lithium niobate electric field sensors
We present our results for using thin film lithium niobate devices for electric field sensing applications. Micro-ring modulator and Mach–Zehnder modulator-based electric field sensors are demonstrated. Micro-ring resonator sensors can be used for low frequency (up to several GHz) electric field sensing applications and achieve a high sensitivity of 80 mV/(m Hz 1/2 ) with a very compact size of 300 μm, as limited by the intensity and phase noise of the used distributed feedback laser. A measurement bandwidth of 2.5 GHz is measured for these sensors and is limited by the detector bandwidth. Alternatively, Mach–Zehnder modulators allow for perfect phase matching between the radio frequency signals and optical signals, and they can be used for electric field sensing up to several THz. A sensitivity of 2.2 V/(m Hz 1/2 ) was obtained using our Mach–Zehnder electric field sensor with an interaction length of 600 μm. The Mach–Zehnder sensor can sense electric fields with frequencies reaching 0.6 THz based on the calculated results.
Improved Line Outage Detection in Transmission Systems with Few PMUs
Unlike transmission systems, distribution systems historically lack enough measurements, making their real-time monitoring almost impossible. Recent deployment of diverse types of devices such as phasor measurement units (PMUs), smart meters, solar inverters and weather information sensors opens up new ways of monitoring these systems, with the assistance of customized machine learning (ML) applications. The paper describes a grid-model-informed machine learning (ML) tool which integrates heterogeneous data streams and creates synchronous measurement snapshots to be used by a hybrid robust state estimator (SE) which provides not only accurate state estimates but also real-time feedback for ML model refinement. Improved monitoring performance due to the use of developed computational framework is experimentally observed by simulated scenarios on an electric utility’s distribution system.
Overview of ASDEX upgrade results in view of ITER and DEMO
Experiments on ASDEX Upgrade (AUG) in 2021 and 2022 have addressed a number of critical issues for ITER and EU DEMO. A major objective of the AUG programme is to shed light on the underlying physics of confinement, stability, and plasma exhaust in order to allow reliable extrapolation of results obtained on present day machines to these reactor-grade devices. Concerning pedestal physics, the mitigation of edge localised modes (ELMs) using resonant magnetic perturbations (RMPs) was found to be consistent with a reduction of the linear peeling-ballooning stability threshold due to the helical deformation of the plasma. Conversely, ELM suppression by RMPs is ascribed to an increased pedestal transport that keeps the plasma away from this boundary. Candidates for this increased transport are locally enhanced turbulence and a locked magnetic island in the pedestal. The enhanced D-alpha (EDA) and quasi-continuous exhaust (QCE) regimes have been established as promising ELM-free scenarios. Here, the pressure gradient at the foot of the H-mode pedestal is reduced by a quasi-coherent mode, consistent with violation of the high-n ballooning mode stability limit there. This is suggestive that the EDA and QCE regimes have a common underlying physics origin. In the area of transport physics, full radius models for both L- and H-modes have been developed. These models predict energy confinement in AUG better than the commonly used global scaling laws, representing a large step towards the goal of predictive capability. A new momentum transport analysis framework has been developed that provides access to the intrinsic torque in the plasma core. In the field of exhaust, the X-Point Radiator (XPR), a cold and dense plasma region on closed flux surfaces close to the X-point, was described by an analytical model that provides an understanding of its formation as well as its stability, i.e., the conditions under which it transitions into a deleterious MARFE with the potential to result in a disruptive termination. With the XPR close to the divertor target, a new detached divertor concept, the compact radiative divertor, was developed. Here, the exhaust power is radiated before reaching the target, allowing close proximity of the X-point to the target. No limitations by the shallow field line angle due to the large flux expansion were observed, and sufficient compression of neutral density was demonstrated. With respect to the pumping of non-recycling impurities, the divertor enrichment was found to mainly depend on the ionisation energy of the impurity under consideration. In the area of MHD physics, analysis of the hot plasma core motion in sawtooth crashes showed good agreement with nonlinear 2-fluid simulations. This indicates that the fast reconnection observed in these events is adequately described including the pressure gradient and the electron inertia in the parallel Ohm’s law. Concerning disruption physics, a shattered pellet injection system was installed in collaboration with the ITER International Organisation. Thanks to the ability to vary the shard size distribution independently of the injection velocity, as well as its impurity admixture, it was possible to tailor the current quench rate, which is an important requirement for future large devices such as ITER. Progress was also made modelling the force reduction of VDEs induced by massive gas injection on AUG. The H-mode density limit was characterised in terms of safe operational space with a newly developed active feedback control method that allowed the stability boundary to be probed several times within a single discharge without inducing a disruptive termination. Regarding integrated operation scenarios, the role of density peaking in the confinement of the ITER baseline scenario (high plasma current) was clarified. The usual energy confinement scaling ITER98(p,y) does not capture this effect, but the more recent H20 scaling does, highlighting again the importance of developing adequate physics based models. Advanced tokamak scenarios, aiming at large non-inductive current fraction due to non-standard profiles of the safety factor in combination with high normalised plasma pressure were studied with a focus on their access conditions. A method to guide the approach of the targeted safety factor profiles was developed, and the conditions for achieving good confinement were clarified. Based on this, two types of advanced scenarios (‘hybrid’ and ‘elevated’
Unified ELM Suppression on KSTAR and DIII-D via Adaptive Feedback Control Strategies
This paper reports on the extension of our amplitude-based resonant magnetic perturbation (RMP) edge localized mode (ELM) controller to support phasing control (relative toroidal phases of RMP waveforms between rows of coils), multiple toroidal mode numbers, and new ‘jump’ and ‘probing’ strategies, all deployed on KSTAR and DIII-D. By treating the control algorithm as device-independent and adjusting only the real-time interfaces to sensors and power supplies, we have confirmed that the same finite state machine—based feedback logic can be ported between machines with minor modifications. In experiments using n = 2 RMPs on KSTAR and n = 3 on DIII-D, the controller successfully modulated RMP amplitudes in real time to sustain ELM suppression while minimizing confinement degradation. Phasing control broadened the suppression window, as it permitted the system to avoid locked-mode regions and safely access ELM-free conditions. A rotating RMP phasing scheme, integrated into the same framework, distributes divertor heat loads more uniformly, making it a promising strategy for protecting plasma-facing components during long discharges. New ‘jump’ and ‘probing’ techniques demonstrate the possibility for the controller to preempt imminent ELMs and refine the minimum required RMP amplitude without returning to ELMy conditions. Taken together, these upgrades enable extended ELM-free operation while mitigating confinement degradation, providing a practical framework for real-time ELM control in future high-performance tokamaks.
Experiences and Lessons from Field Demonstration of Grid-forming Inverter in An AC Microgrid
The validation of GFM control strategies through simulation and hardware demonstration is important before their large-scale deployments in the real grid. Considering the importance of testing and validation, several works have explored the GFM inverter’s capability to blackstart a microgrid, synchronize and share loads, and interact with various types of generation sources and loads present in the grid. Herein, this paper complements the existing works by presenting the results and analysis of a field demonstration in an actual AC microgrid. The capability of a three-level neutral point clamped (NPC) GFM inverter equipped with a recursive feedback type of non-linear device level control to operate with PV source on its DC input and off-the-shelf PVGFL inverters and EV chargers of different kinds on the AC side is explored. The analysis and conclusions drawn would inform the readers to make better decisions during the field demonstration process.
Performance of a large area photon detector for rare event search applications
We present the design and characterization of a large-area Cryogenic PhotoDetector designed for active particle identification in rare event searches, such as neutrinoless double beta decay and dark matter experiments. The detector consists of a 45.6 cm 2 surface area by a 1-mm-thick 10.6 g Si wafer. It is instrumented with a distributed network of Quasiparticle-trap-assisted Electrothermal feedback Transition-edge sensors with superconducting critical temperature T c = 41.5 mK to measure a thermal phonons released from interactions with photons.
On-PIC Light Source Integration & Micro-dispensing of Solder Paste for Flip Chip Application
To reach the next level benefits of photonic integrated circuits (PICs), the Integrated Photonic Systems Roadmap-International describes the necessity of either heterogeneous or hybrid integration of light sources [1]. A new approach for hybrid integration is Photonic Wire Bonding where 3D nanolithography is used to pattern a polymer waveguide that connects light sources to PIC waveguides. The waveguides resemble electrical wire bonds and essentially do the same as their electrical counterpart for packaging photonic chips together. In order to reap the full benefits of a photonic wire bonds, the light source must be carefully packaged. In this work I seek to expand RIT’s photonic packaging capability by establishing a packaging process to integrate light sources, specifically an Indium Phosphide distributed feedback lasers and a reflective semiconductor optical amplifiers, directly onto a photonic integrated circuits. Another necessary requirement for PIC packaging is densely integrated electrical connectivity. In this thesis I developed a fine pitch flip chip interconnect technique demonstrated using gold stud bumps in conjunction with micro-dispensed solder paste. This work opens the door to high density photonic flip chip applications. The micro-dispensed solder paste dots having diameters 50-125 µm are currently being tested at a pitch of 150 µm . The gold stud bumps are formed with 1mil gold wire creating bumps with a diameter of 40-60 µm depending on specific parameter values. These capabilities will allow RIT to assemble and test novel photonic integrated devices, cutting down on the time and cost associated with third party assembly and tests facilities. Thereby keeping RIT at the forefront of photonic research.
Securing Inverter Communication: Proactive Intrusion Detection and Mitigation System to Tap, Analyze, and Act
The electric grid has undergone rapid, revolutionary changes in recent years; from the addition of advanced smart technologies to the growing penetration of distributed energy resources (DERs) to increased interconnectivity and communications. However, these added communications, access interfaces, and third-party software to enable autonomous control schemes and interconnectivity also expand the attack surface of the grid. To address the gap of DER cybersecurity and secure the grid-edge to motivate a holistic, defense-in-depth approach, a proactive intrusion detection and mitigation system (PIDMS) device was developed to secure PV smart inverter communications. The PIDMS was developed as a distributed, flexible bump-in-the-wire (BITW) solution for protecting PV smart inverter communications. Both cyber (network traffic) and physical (power system measurements) are processed using network intrusion monitoring tools and custom machinelearning algorithms for deep packet analysis and cyber-physical event correlation. The PIDMS not only detects abnormal events but also deploys mitigations to limit or eliminate system impact; the PIDMS communicates with peer PIDMSs at different locations using the MQTT protocol for increased situational awareness and alerting. The details of the PIDMS methodology and prototype development are detailed in this report as well as the evaluation results within a cyber-physical emulation environment and subsequent industry feedback.
Enabling Modular Autonomous Feedback‐Loops in Materials Science through Hierarchical Experimental Laboratory Automation and Orchestration
Abstract Materials acceleration platforms (MAPs) operate on the paradigm of integrating combinatorial synthesis, high‐throughput characterization, automatic analysis, and machine learning. Within a MAP, one or multiple autonomous feedback loops may aim to optimize materials for certain functional properties or to generate new insights. The scope of a given experiment campaign is defined by the range of experiment and analysis actions that are integrated into the experiment framework. Herein, the authors present a method for integrating many actions within a hierarchical experimental laboratory automation and orchestration (HELAO) framework. They demonstrate the capability of orchestrating distributed research instruments that can incorporate data from experiments, simulations, and databases. HELAO interfaces laboratory hardware and software distributed across several computers and operating systems for executing experiments, data analysis, provenance tracking, and autonomous planning. Parallelization is an effective approach for accelerating knowledge generation provided that multiple instruments can be effectively coordinated, which the authors demonstrate with parallel electrochemistry experiments orchestrated by HELAO. Efficient implementation of autonomous research strategies requires device sharing, asynchronous multithreading, and full integration of data management in experimental orchestration, which to the best of the authors’ knowledge, is demonstrated for the first time herein.
IoT-Based Comfort Control and Fault Diagnostics System for Energy-Efficient Homes
This project studies an Internet of Things (IoT)-based comfort control and fault diagnostics system (referred as iComfort in this report) for energy-efficient homes. The system delivers an occupant-comfort-oriented thermal environment adaptive to fault scenarios and achieves HVAC energy savings in a cost-effective and straightforward way. This smart iComfort home system consists of the following key features. 1) Cost-effectiveness and scalability of the entire hardware and software system: The system includes low-cost temperature, humidity, and airflow sensors, and a Raspberry Pi-based local hub that interfaces with the cloud and IoT-enabled devices. The cost is low, not only for sensors, but also the costs associated with sensor installation, system setup and commissioning, data communication and storage, and data analytics (e.g., the development of automated fault detection and diagnosis (AFDD), as well as adaptive control strategies that are both computationally efficient and practical to implement). 2) Energy performance and user satisfaction: The system delivers user satisfaction and energy savings. This includes a) ease of use, b) optimal occupant thermal comfort, and c) accurate system feedback (e.g., low false alarm of AFDD strategies). 3) Favorable demonstrated prototype performance: The prototype tested at the Pacific Northwest National Laboratory (PNNL) Lab Homes demonstrates the accuracy of fault detections and diagnoses and shows thermal comfort improvement and energy savings through adaptive and optimal HVAC operations.