Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed wind turbine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Integration of Storage in the DC Link of a Full Converter-Based Distributed Wind Turbine

Energy storage is known to support the dispatchability of variable renewable resources. In this paper, we model a battery energy storage system (BESS) integrated with the DC link of a Type IV full converter-based wind turbine and the necessary controls to achieve efficient dispatch. To support the validation of control methodologies, we build a detailed model of a Type IV research wind turbine at the National Renewable Energy Laboratory (NREL), the Controls Advanced Research Turbine (CART 3), and we integrated a lithium-ion BESS model in grid-following mode into the model. The simulation results illustrate the sizing and control of the DC link-integrated BESS for a given variable wind resource and varying dispatch strategies (i.e., under constant, uncertain, and ramping wind scenarios). The integrated storage can smooth variabilities in distributed wind output, hedge against uncertainties, provide the ramping capability, as well as support stability under voltage and frequency transients. All of these have been illustrated in MATLAB/Simulink.

DC-link voltage↗

An Evaluation of Advanced Tools for Distributed Wind Turbine Performance Estimation

We evaluate various classes of distributed wind turbine performance tools across two sites in the United States. The class of tools ranges from the simple mass conservation model to the coupled Reynolds-averaged Navier-Stokes model, all initiated by the WIND Toolkit data set. The resource estimation at the site is evaluated against measured data at the mast location. Taking a sample 100-kW wind turbine and constant losses, we evaluate Openwind, Continuum, and WindNinja tools and document annual energy production (AEP) and time-series statistics associated with the performance estimation of the wind turbine. Using a methodology that is consistent and unbiased across the three options currently available in the industry, we elaborate results at the two sample locations and discuss the probable sources of discrepancy in the AEP estimates. Two main sources of the discrepancy come from the input WIND Toolkit data and the spatial modeling techniques of the tools to capture atmospheric physics. The discussion includes additional values that these tools may bring into the energy assessment process to enhance the owners' confidence over the distributed wind power systems.

17 WIND ENERGY↗

An Evaluation of Advanced Tools for Distributed Wind Turbine Performance Estimation: Preprint

We evaluate various classes of distributed wind turbine performance tools across two sites in the USA. The tools class ranges from the simple mass conservation model to coupled Reynolds Averaged Navier-Stokes (RANS) model, all initiated by the WIND Toolkit dataset. The resource estimation at the site is evaluated against measured data at the mast location. Taking a sample 100 kW wind turbine and constant losses, we evaluate Openwind, Continuum, and WindNinja tools and document Annual Energy Production (AEP) and time series statistics associated with the performance estimation of the wind turbine. Using a methodology that is consistent and unbiased across the three advance options currently available in the industry, we elaborate results at the two sample locations and discuss the probable sources of discrepancy in the AEP estimates. The discussion includes additional values these tools may bring into the energy assessment process to enhance the owners' confidence over the distributed wind power systems.

17 WIND ENERGY↗

Design Load Basis Guidance for Distributed Wind Turbines

Aeroelastic modeling (AM) is the primary methodology for structural and performance assessment of any wind turbine. Nonetheless, the use of AM in the distributed wind (DW) industry sector is limited due to several challenges (Damiani, Davis, & Summerville, 2022). One of these challenges lies in the perceived complexity of generating a proper set of numerical simulations to extract and process the key outputs for component design and verification, and, ultimately, achieve certification. This makes it difficult to reliably predict the structural and performance response of small wind turbines. From the investigation carried out in (Damiani & Davis, 2022), it is apparent that many stakeholders in this sector believe that a comprehensive guide for developing a design load basis (DLB) for distributed wind turbines (DWTs) is necessary.

17 WIND ENERGY↗

Advanced Distributed Wind Turbine Controls Series: Part 3-Wind Energy in Grid-Connected Deployments – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In recent years the technical ability and requirement for distributed wind turbines to provide grid support services beyond maximum energy production has increased. Ancillary services leveraged through advance controls of a wind turbine support grid reliability and resilience. One ancillary service that is significant to a grid-connected wind turbine deployment is fault ride through (FRT) in response to the voltage and frequency events in the power system. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) this paper demonstrates, through desktop simulations, the wind turbine's FRT capabilities to support stable grid operation. We establish that the wind turbine models exceed FRT performance requirements stipulated in IEEE 1547-2018, regarding interconnection and interoperability of distributed energy resources. Utilizing a standalone CART2 (600 kW) wind turbine connected to the NREL's Flatirons Campus grid, we study voltage and frequency FRT utilizing various test cases. One of the test cases under study is a Category III voltage fault defined in IEEE 1547-2018 and derived from CA Rule 21. Some distributed wind turbines were unable to connect to the grid following the Rule 21 enforcement in California. Even if this is not a general requirement elsewhere, the grid codes might evolve in this direction. This study illustrates how a distributed wind turbine can provide some of these FRT services and enable a pathway toward a higher contribution of renewable energy in a distribution grid.

17 WIND ENERGY↗

Advanced Distributed Wind Turbine Controls Series: Part 1-Flatirons Campus Model Overview – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

Wind turbines are typically deployed to provide energy, reduce diesel-fuel consumption, reduce carbon emissions, and reduce costs for energy and fuel transportation. However, in addition to solely providing energy to the power system, wind turbines contain rotating masses and inverter-based controls that can enable various reliability and resilience services through advance controls. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL), it is demonstrated that advanced wind turbine controls can be employed to support higher contributions of wind, and to demonstrate ways that wind can play a role in supporting grid stability in islanded or grid-connected configurations. This paper documents models of various subsystem comprising a portion of NREL's Flatirons campus that will be used in three subsequent reports to demonstrate capabilities of advanced wind turbine controls. The series of reports will detail advanced capabilities of distributed wind turbines to provide support to isolated grids, distribution grids, and microgrids. We developed models to simulate a wind turbine (600 kW), solar PV (430 kW), battery energy storage system (1 MW/1MWh), a diesel generator (2 MW) and various types of loads (critical, dynamic). The model of the subsystems in MATLAB/Simulink are validated with available data from real-world components on NREL's Flatirons Campus. These validated models can be configured for various studies including four MIRACL use cases: 1) isolated grids, 2) microgrids, and 3) behind-the-meter, and 4) front-of-the-meter wind turbine deployments.

17 WIND ENERGY↗

Loss Factors for Small Distributed Wind Turbines Based on Field Data in the United States

While wind energy production loss due to unavailability, environmental impacts, curtailment, and other causes has been studied and characterized at the utility-scale wind farm level, observation-based characterization of project loss is lacking for distributed wind energy, particularly for projects involving small wind turbines. Contemporary tools and research that support pre-construction distributed wind energy characterization present a wide range of default loss factors to convert gross energy estimates to net: 7-18%. We hypothesize that we can use generation observations from operational distributed wind projects to develop more accurate representations of loss. Using a density-based filtering technique on distributed wind power generation timeseries, we determine periods of typical performance and use them with regression algorithms in a measure-correlate-predict fashion to simulate what the generation would have been during periods of atypical or unreported performance. From there, the actual versus predicted generation leads to the establishment of observation-informed loss factors (median = 17%) for small, single turbine installation distributed wind projects.

17 WIND ENERGY↗

Valuation of Distributed Wind Turbines Providing Multiple Market Services

The role of wind turbines has traditionally been limited to providing energy capacity to the grid, but the availability of smart inverters and recent regulatory changes provide the technical and policy capability for wind turbines to also provide ancillary services. However, in contrast to the technical and policy aspects, the valuation of distributed wind turbines providing such services has not been thoroughly studied. This paper presents an optimal market-participation method for distributed wind turbines and valuates different strategies in California Independent System Operator’s balancing area. The services include energy capacity, regulation up and down, and reserves. An optimization problem is formulated to determine optimal power output for each service and demonstrated using historical data for one complete year. The revenues from multiple services are quantified, and a sensitivity analysis is performed to relate market prices with revenues. It is found that the optimal strategy generates 6% more revenue compared to the revenue from participating in the energy market only. Also, the reduced energy prices in future scenarios increase the relative importance of market participation in ancillary services.

Bhatti, Bilal Ahmad↗

Advanced Distributed Wind Turbine Controls Series: Part 4-Wind Energy in Microgrids – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In recent years, the technical capabilities and requirements for distributed wind turbines to provide ancillary services beyond maximum energy production has increased. Ancillary services, leveraged through advanced wind turbine controls, can support grid stability, reliability, and resilience. In the context of a microgrid, wind turbines can provide ancillary services that are useful in both islanded and grid-connected modes, as demonstrated in previous parts of this report series. This report focuses on how wind turbines with advanced controls and power electronics can support the stability of the microgrid during transitions from grid-connected to island mode, and back. This report documents simulation results from a model of the National Renewable Energy Laboratory (NREL) Flatirons Campus containing NREL's 600-kilowatt Controls Advanced Research Turbine. Using this turbine, we demonstrate through desktop simulation how a wind turbine can support the voltage and frequency of a microgrid during transitions - from making planned transitions seamless to keeping all loads online during some unplanned transitions to supporting black start in the event of an open transition (blackout).

17 WIND ENERGY↗

Aeroelastic Modeling for Distributed Wind Turbines: March 11, 2021 - November 10, 2021

Aeroelastic modeling (AM) is the primary methodology for structural and performance assessment of any wind turbine whereby providing an understanding of the impact of design parameters on its loading and power response before witnessing it in the field. Despite these advantages, the use of AM in the Distributed Wind Technology (DWT) sector is limited, especially within the less established manufacturers. This project represents an in-depth assessment of the status of AM and its role within the Standards for the DWT industry. The study gathered input and feedback from a large number of national and international stakeholders, reviewed technical strengths and weaknesses of the current edition of the design standards, analyzed recent industry workshops' and meetings' minutes, collected publicly available AM templates, and provided an evaluation of the existing AM codes. The study achieved several goals including providing strategies for the load assessment categorization of turbines based on rotor swept area and archetype, and guidance for AM verification and validation (V&V), which includes discussions of measurement requirements and a sample test-plan useful for future V&V campaigns and design standard development. This document summarizes the different tasks conducted in the course of the project and highlights the steps required to improve the AM adoption based on a multifaceted approach that encompasses: 1) augmenting AM software capabilities, 2) publishing AM best-practices and design-basis, 3) creating new model templates, 4) providing guidance for V&V of codes and specific turbine models leveraging field testing best-practice, and 5) addressing weaknesses in the current standards. Many of the future objectives identified in this study could leverage NREL's upcoming testing campaigns of three modern distributed wind turbines. Recommendations within this study will advance the value and the ease-of-use of AM, thereby allowing the industry to better capitalize this underutilized tool resulting in a more efficient design process, an easier path to certification, and overall better and more distributed reliable wind turbine products.

17 WIND ENERGY↗

Advanced Distributed Wind Turbine Controls Series: Part 2-Wind Energy in Isolated Grids – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In an isolated grid, wind turbines are typically deployed to provide energy to maximize energy production, reduce diesel-fuel consumption, reduce carbon emissions, and reduce costs for energy and fuel transportation. However, in addition to solely providing energy to the power system, wind turbines contain rotating masses and inverter-based controls that can enable various reliability and resilience services through advance controls. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) this paper demonstrates, through desktop simulations, advanced wind turbine controls that can be employed to support higher contributions of wind in isolated grids, and to demonstrate ways that wind can play a role in supporting stability of an isolated grid. This isolated grid used in these desktop simulations is comprised of a wind turbine (600 kW), solar PV (430 kW), battery energy storage system (1 MW/1MWh), a simulated diesel generator (2 MW) and various types of loads (critical, dynamic). We developed a model of the subsystems in MATLAB/Simulink and validated them with available data from real-world components on NREL's Flatirons Campus. These validated models are then configured for various case studies. We compare the output of the desktop simulation with a baseline case with the diesel generator. Active and reactive power control of the wind turbine can help improve frequency and voltage responses in the isolated grid, respectively. By utilizing a small integrated battery energy storage system in the DC-link of the wind turbine, we also demonstrate that wind turbines can help blackstart a critical load comparable to its rated power and support other renewables (e.g. solar PV) come online and pick up an additional load. This report illustrates some of these reliability and resilience services a wind turbine can provide in an isolated grid.

17 WIND ENERGY↗

NREL 15-kW: An Advanced Horizontal-Axis Reference Turbine for Distributed Wind

Distributed wind energy can play a significant role in the renewable energy landscape. A recent study conducted by the National Renewable Energy Laboratory (NREL) identified the lack of availability and utilization of reference wind turbine models as a major hindrance in the development of the distributed wind energy technology sector, even though such models are widely used in offshore and land-based wind research. Therefore, NREL is developing three reference wind turbine architectures, also called archetypes, for distributed wind energy applications. This paper describes the detailed design and modeling of the first of the three reference turbine archetypes, called the NREL 15-kW turbine. It is a passive-yaw, upwind turbine with a rated power of 15 kW.

17 WIND ENERGY↗

2021 Prototype Manufacture and Installation Awardee: Pecos Wind Power, Inc.

Through the 2021 Competitiveness Improvement Project (CIP), Pecos Wind Power will manufacture a prototype of its 85-kilowatt (kW) horizontal-axis distributed wind turbine, the PW85, a new wind turbine that began development in 2017 when the company was founded. The PW85 wind turbine includes an industry-leading rotor diameter (30 meters) and full-span variable pitch blades to target a levelized cost of energy (LCOE) of $0.103/kilowatt-hour in low annual wind speeds (6 meters per second). This is 55% lower than the average small wind turbine project installed in 2018. The goal of this project is to spur the development of increasingly lower-cost, high-capacity-factor distributed wind turbines. As a result, Pecos Wind Power will manufacture and install wind turbines that increase the geographic area in which distributed wind power is cost competitive with retail-priced electricity and other distributed energy resources - primarily solar energy.

CIP↗

2021 Small Turbine Certification Awardee: Intergrid LLC

Currently, there are no U.S., fully certified inverters for wind turbines in the 10-15-kilowatt (kW) range. The federal government's Competitiveness Improvement Project (CIP) and Small Business Innovation Research programs present the most viable paths for manufacturers in the distributed wind energy industry to conduct research, develop their products, and, ultimately, commercialize them. Through CIP, Intergrid LLC is reducing the cost, size, and weight of its legacy inverter for distributed wind turbines while increasing efficiency, reliability, and serviceability. To accomplish this, Intergrid will address three areas related to power electronics for distributed wind turbines: (1) Software verification and functional safety certification; (2) Simulation for grid-interconnecting testing; (3) Component alternatives that reduce cost and improve reliability and serviceability. The first two areas relate to long-term management of inverter software, which, for grid-connected inverters, must comply with three standards - one issued by Underwriters Laboratories (UL) and two issued by the Institute of Electrical and Electronics Engineers.

CIP↗

Data-Driven Generic Turbines for Distributed Wind Modeling, Optimization, and Economic Studies

As distributed energy resources (DER) become less expensive and more popular, utilities, project developers, and customers have an increasing need to model the performance of existing and proposed DER systems. Distributed wind has been shown to have widespread economic potential but is often represented by a simplified model in - or excluded from - DER modeling tools and studies. There is often no economic imperative to extend models and studies to give full consideration to distributed wind. We present a set of data-driven generic turbines derived from 16 years of annual distributed wind market survey data. The proposed methodology can be used to derive generic turbines from separate or updated data sets. Finally, a mixed-integer linear programming approach to optimal distributed wind project sizing is used to demonstrate the generic turbine models. Combined, these models and methods can reduce barriers to considering distributed wind in modeling tools and studies.

Reiman, Andrew P.↗

Hybrid Power Plants for Energy Resilience: A Case Study

As renewable energy technologies are increasingly adopted, they pose an opportunity to improve the sustainability and resilience of distributed grids, especially when their design and operation is coordinated as a hybrid power plant. When included in hybrid power plants, distributed wind turbines in particular have the potential to enhance the resilience of distributed grids in areas with good wind resource, due to their ability to provide more consistent generation and ancillary services as compared to photo-voltaic (PV) solar panels. Despite this benefit, U.S. distributed wind adoption is lower than other comparable renewable energy technologies. In this study, we seek to demonstrate how hybrid power plants that include distributed wind turbines can contribute to distribution grid resilience by meeting loads (especially critical loads) more consistently, increasing reserve capacity, and providing value to customers during outages. To demonstrate these contributions, we integrate three separate frameworks and apply them to a case study in a rural electric cooperative in Iowa. Through this case study, we simulate and compare hybrid power plant design and operation during two hazard events: a tornado that causes a 48-hour distribution outage and a winter weather event that causes a 6-hour generation outage. The inclusion of a hybrid power plant that leverages 1) increased battery duration and 2) advanced forecasting and dispatch strategies that reserve capacity leading up to a hazard event best reduce lost loads as well as diesel consumption that would otherwise be used to meet those loads during short- and long-duration hazard events. Depending on the hybrid power plant capacity and operation, we find that the outage mitigation value of a hybrid power plant (measured in value to customers to avoid an outage and avoided lost revenues for the utility) is significant in both hazard events; adding wind, solar, and battery assets to the existing system adds about $50-$100M in avoided lost load and at least $4-$8k in utility value in the tornado hazard event, and $570k-$2.2M in avoided lost load and at least $220-$650 in utility value in the winter hazard scenario. In both the tornado and winter hazard scenarios, optimizing the operation of the hybrid system for resilience can lend similar value as increasing battery duration by 5 MWh for the lower capacity systems considered.

17 WIND ENERGY↗