Search NASASearch

SEARCH · Search NASA

Results for “distribution network”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Enabling Grid-Forming Control with Fault Ride-Through in Unbalanced Distribution Networks

Distribution networks are often unbalanced, causing oscillatory responses in inverter control designed for balanced conditions. Here, to address this problem, this paper proposes a novel time-domain transformation appropriate for inverter control and enables the decomposition of three-phase unbalanced signals into constant positive and negative components. Relations useful for calculating unbalanced active and reactive power are derived from first principle, providing insight into vector products of unbalanced three-phase signals. Furthermore, a grid-forming control effective under unbalanced conditions is developed, which delivers superior performance while meeting UNIFI1 specifications for grid-forming control under unbalanced conditions. specifications applicable to category 4 inverter-based resource, like setting and regulating frequency/voltage, providing voltage support, sharing active power, injecting negative sequence current, and riding through faults. A current limiter is proposed for safe fault ride-through and integrates with the grid-forming control featuring frequency/voltage droop controllers and current and voltage control loops. The transformation of interconnected inverters is formulated and stability of the proposed control analyzed to support robust parameter selections. The effectiveness of the proposed transformation and grid-forming control is demonstrated through analytical results and real-time simulation of a IEEE 123 distribution network on the Real-Time Digital Simulator. Comparison with existing methods shows that the proposed strategy satisfies the UNIFI specifications with a much better performance.

24 - POWER TRANSMISSION AND DISTRIBUTION

Predicting Large‐Scale Systematic Missing Pipe Attributes in Water Distribution Networks

Water distribution network (WDN) models are an essential tool used by water utilities for hydraulic analysis. Unfortunately, missing data and insufficient resources often make creating and maintaining these models unfeasible. Existing methods to address missing pipe properties, like sequential imputation for missing values and reconstruction using graph metrics, are designed to accommodate random patterns of missing information and require a significant percentage of the system's attributes to be known. However, these data completeness assumptions do not always align with real‐world scenarios where large sections of the WDN model have missing data. To address this challenge, this study proposes a data‐driven approach for estimating pipe diameter when considering different spatial patterns and degrees of data completeness (i.e., 0%–90%). Using data from 16 WDNs in Kentucky, this study compares the use of machine learning (ML) using topological and geospatial features against an existing deterministic approach. Results demonstrate that WDN models with pipe diameters predicted by the proposed ML method had comparable hydraulic performance to the ground truth models. Moreover, results showed that ML method performance varies between WDNs of differing topological classification. Insights from this study help advance the ability to leverage partial data to create and maintain WDN models amid uncertainty and inadequate resources.

Poff, Jason W. [Oregon State Univ., Corvallis, OR

Joint scheduling of energy, fast and primary frequency response reserves in integrated transmission–distribution networks

Inverter-based distributed energy resources (DERs) connected to distribution networks (DNs) can provide fast frequency support, but their reserve deliverability depends on feeder constraints and differs from synchronous primary frequency response (PFR). Existing transmission–distribution coordination studies usually treat reserve generically or neglect feeder-level feasibility, while frequency-security scheduling studies rarely represent distribution feeders explicitly. This paper develops a bi-level day-ahead scheduling framework for integrated transmission–distribution networks that jointly clears energy, transmission-side PFR, and distribution-side fast frequency response (FFR) under exogenous hourly inertia and largest-loss inputs from an external unit commitment (UC) schedule. The transmission problem is modeled with DC-optimal power flow (OPF) and closed-form second-order cone (SOC) frequency-security constraints, whereas each DN is represented by a reserve-aware branch-flow AC-OPF so that scheduled fast reserves remain deliverable during activation. The bi-level problem is reformulated through Karush–Kuhn–Tucker (KKT) conditions into a mixed-integer SOC program, and a penalty term is used to tighten the distribution-network relaxation. In the reduced test system, lower exogenous inertia increased the required primary response from 179.64 MW to 191.08 MW, distribution-side fast response reduced total frequency-response procurement by up to 4.9%, and neglecting distribution constraints overstated the combined distribution-side energy and reserve award by up to 18%. In the expanded study, the largest case was solved in 2.02 s with a 0.00% optimality gap. Time-domain simulations kept the frequency nadir above 59.0 Hz in all tested hours. These results demonstrate the value of fast-response modeling and distribution-feasible reserve delivery in coordinated market clearing.

Noh, Seung-Gil

Surrogate Model for Distribution Networks Influenced by Weather

Here, we propose a method for generating reduced representations of time series and for constructing low dimensional surrogate models for time dependent calculations of power and voltage in distribution networks. We employ Fourier polynomials. The surrogate model strategy is aimed at reducing the computational cost of time dependent simulations, albeit, at the expense of fidelity. The reduced representation is achieved by identifying a small and most consequential subset of degrees of freedom. In power and voltage distribution networks dynamics that are heavily influenced by strong cyclic weather events, e.g., the hourly, diurnal and seasonal cycles, the weather/climate time series spectrum exposes these most energetic components. Once the degrees of freedom are identified their amplitudes are optimized using training data. The key challenge in using spectral methods in power network surrogates is addressing the computation of quotients. For this we propose a numerically-stable deconvolution strategy.

Weather events

Use of Digital Real-Time Simulation and Optimization to Identify Maximum Real Power Injection on Banshee Distribution Network

This study investigates the hosting capacity of the Banshee Distribution Network by optimizing the real power injection at carefully selected Distributed Energy Resource (DER) locations. The analysis is conducted within the framework of power system operational constraints, including bus voltage ranges, thermal line ratings, and transformer loading limits. A Python-based Genetic Algorithm (GA), implemented using the PyGAD library, is employed to iteratively identify the optimal power injection configuration that maximizes network utilization while preserving system reliability. The methodology integrates a real-time simulation environment using the Real-Time Digital Simulator (RTDS), allowing high-fidelity evaluation of power flow and voltage behavior under each proposed injection scenario. By coupling the optimization algorithm with real-time simulation feedback, this approach ensures that both static and dynamic constraints are enforced during the evaluation process. The GA leverages evolutionary operators such as selection, crossover, and mutation to navigate the nonlinear search space efficiently. The results of the study delineate the feasible hosting capacity at three targeted buses, reflecting maximum real power levels that can be injected without causing voltage violations, transformer overloading, or line congestion. These findings provide a decision- support tool for distribution planners and utilities aiming to integrate higher penetrations of DERs in existing infrastructure. Additionally, the work lays the foundation for extending such optimization techniques to multi-objective formulations, including economic dispatch and reactive power coordination, in future studies.

24 POWER TRANSMISSION AND DISTRIBUTION

Distributed Online Voltage Control in Distribution Network: A Two-Stage Real-Time Implementation

The increasing integration of renewable-based distributed generation (DG) brings growing challenges to distribution network (DN) voltage control. To address this issue, a two-stage distributed online voltage control framework (TDO-VC) is proposed in this paper. In the proposed method, legacy voltage control devices are controlled in the upper stage on an hourly timescale, while DGs operate autonomously online in the lower stage to remove instantaneous voltage violations. The idea of receding horizon control is applied in the upper stage to comprehensively consider the current and future renewable generation, and the generalized fast dual ascent (Gf-DA) is employed in the lower stage to effectively manage DGs through near real-time optimization. The effectiveness of the proposed TDO-VC is demonstrated by rigorous theoretical analysis and case studies on IEEE-123 bus system.

Distributed generation

Performance Evaluation of a Novel Sequence-Based Directional Detection Strategy for Protection of Active Distribution Networks

Directional elements are relied on to achieve selectivity in fault detection in power systems. Although such elements have been deployed successfully for many years, there is an increased need for novel methods to deal with the unique challenges of directional protection in modern distribution networks. This article analyzes the impact of inverter-based resources (IBRs) on existing directional protection methods in distribution systems. It identifies parts of such elements that pose a risk of misoperation when IBRs are used in distribution networks. The authors have developed a new directional detection method for unbalanced faults in such networks using superimposed symmetrical sequence quantities. The phase angle of the superimposed negative sequence admittance is used to determine fault direction. The paper also presents a real-time co-simulation platform between a simulated distribution system and physical protection relay, using OPAL-RT. An SEL-411L relay is used to program the detection algorithm. This hardware-in-the-loop (HIL) setup is used to verify the performance of the method and the results are compared with existing directional methods

24 POWER TRANSMISSION AND DISTRIBUTION

Use of Digital Real-Time Simulation and Optimization to Identify Maximum Real Power Injection on the Banshee Distribution Network: Preprint

This study investigates the hosting capacity of the Banshee Distribution Network by optimizing the real power injection at carefully selected Distributed Energy Resource (DER) locations. The analysis is conducted within the framework of power system operational constraints, including bus voltage ranges, thermal line ratings, and transformer loading limits. A Python-based Genetic Algorithm (GA), implemented using the PyGAD library, is employed to iteratively identify the optimal power injection configuration that maximizes network utilization while preserving system reliability. The methodology integrates a real-time simulation environment using the Real-Time Digital Simulator (RTDS), allowing high-fidelity evaluation of power flow and voltage behavior under each proposed injection scenario. By coupling the optimization algorithm with real-time simulation feedback, this approach ensures that both static and dynamic constraints are enforced during the evaluation process. The GA leverages evolutionary operators such as selection, crossover, and mutation to navigate the nonlinear search space efficiently. The results of the study delineate the feasible hosting capacity at three targeted buses, reflecting maximum real power levels that can be injected without causing voltage violations, transformer overloading, or line congestion. These findings provide a decision- support tool for distribution planners and utilities aiming to integrate higher penetrations of DERs in existing infrastructure. Additionally, the work lays the foundation for extending such optimization techniques to multi-objective formulations, including economic dispatch and reactive power coordination, in future studies.

24 POWER TRANSMISSION AND DISTRIBUTION

Improving photovoltaic hosting capacity of distribution networks with coordinated inverter control: A case study of the EPRI J1 feeder

Abstract Adding photovoltaic (PV) systems in distribution networks, while desirable for reducing the carbon footprint, can lead to voltage violations under high solar‐low load conditions. The inability of traditional volt‐VAr control in eliminating all the violations is also well‐known. This article presents a novel coordinated inverter control methodology that leverages system‐wide situational awareness to significantly improve hosting capacity (HC). The methodology employs a real‐time voltage‐reactive power (VQ) sensitivity matrix in an iterative linear optimizer to calculate the minimum reactive power intervention from PV inverters needed for mitigating over‐voltage without resorting to active power curtailing or requiring step voltage regulator setting changes. The algorithm is validated using the EPRI J1 feeder under an extensive set of realistic use cases and is shown to provide 3x improvement in HC under all scenarios.

Dalal, Dhaval [School of Electrical, Computer, and

Study on Application of Distributed Network of Sensors with List Mode for NMAC Literature Review

Nuclear material accounting and control (NMAC) for nuclear security detects, deters, and resolves questions related to unauthorized removal (i.e. theft) or misuse of nuclear material. NMAC also serves as a key insider threat mitigation measure and aids in recovery of nuclear material that is missing. Effective nuclear security depends on NMAC for timely and accurate information about nuclear material types, quantities, and locations. Bulk nuclear material processing facilities, however, present unique challenges for effective NMAC due to the presence of large quantities of material in-process and the accumulation of residual material holdup within process equipment. These holdup accumulations can obscure accurate physical inventory taking and complicate efforts to resolve NMAC irregularities at the facility level. Bulk material monitoring systems often rely on material balance calculations and indirect measurement techniques, which may mask protracted theft of smaller amounts of nuclear material. These monitoring limitations have generated increased interest in continuous monitoring technologies, including distributed non-destructive assay (NDA) sensor networks capable of providing real-time or near-real-time measurement of material movement and accumulation within bulk processing environments. Recent advancements in distributed networks of NDA radiation detectors and sensing technologies provide an opportunity to address these limitations. Although such distributed sensor networks have been implemented in select facilities for IAEA Safeguards applications, their potential for supporting NMAC functions specifically tailored to nuclear security objectives remains largely unexplored. Furthermore, emerging list-mode data acquisition technologies have reached high technology readiness levels, enabling time-correlated detection of nuclear events across multiple temporal scales. These capabilities provide enhanced opportunities for accurate holdup measurement, continuous process monitoring, and improved detection of material theft or misuse over time. The increasing global expansion of civil nuclear power and development of related bulk material processing facilities, including those supporting high-assay low-enriched uranium (HALEU) and other advanced reactor fuel fabrication, further increases the need for advanced measurement and monitoring strategies for NMAC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

An Nginx-based Content Distribution Network for HEP

With the move to HTTP/WebDAV and JSON Web Tokens as a standard protocol for transfers within the WLCG distributed storage network, a large amount of off-the-shelf technologies become viable for meeting the requirements of a Storage Element (SE). In this work, we explore the capabilities and performance of the OpenResty framework, which extends the nginx server with the LuaJIT scripting language, to recreate the feature set of a SE. We demonstrate token-authenticated HTTP read, write, and WebDAV third-party copy features, as well as a storage federation with HTTP redirect, proxy, and caching capabilities. We further explore the performance scaling in terms of throughput and requests per second.

Aarora, Aashay [UC, San Diego]

How Distributed Energy Resources Can Support Resilience in Utility Distribution Networks

The goal of this webinar is to engage with electric utilities in the Midwest, particularly small public utilities, to understand the industry's needs for science tools to plan for winter resilience in the future, designing tools that will benefit electric power resilience in all communities. Michigan Tech leads this project with partners from multiple academic, government, and industry groups and asked NLR to present on DERs and laboratory tools and resources.

24 POWER TRANSMISSION AND DISTRIBUTION

Combined Effects of Electric Vehicle Charging and Rooftop Solar Integration on Voltage Imbalance in Residential Distribution Networks

Residential electric vehicle (EV) chargers, as single phase loads, contribute to unbalanced voltage drops across phases, while rooftop solar systems, as single phase generators, can exacerbate voltage imbalance by causing unbalanced voltage increases. This paper investigates combined effects of residential EV charging and rooftop solar generation on voltage imbalance in residential distribution grids. The study examines these simultaneous impacts using the IEEE 8500-node test system, enhanced with a secondary network to realistically model the EV chargers and rooftop solar integration. To account for the variability and uncertainty in the EV charging loads and solar generation, a Monte Carlo approach is employed to capture and quantify the simultaneous impact of the EV charging and rooftop solar integration. In this approach, multiple influencing factors are considered, including state-of-charge (SOC), maximum charging power levels, and geographic distribution of chargers. The results provide practical insights for utilities and stakeholders, offering expectations for planning and operating strategies that effectively manage the increasing adoption of EVs and solar power while maintaining grid reliability.

Choi, Jongchan [ORNL] (ORCID:000000025952455X)

Graph-based Simulation Framework for Power Resilience Estimation and Enhancement

The increasing frequency of extreme weather events poses significant risks to power distribution systems, leading to widespread outages and severe economic and social consequences. This paper presents a novel simulation framework for assessing and enhancing the resilience of power distribution networks under such conditions. Resilience is estimated through Monte Carlo simulations, which simulate extreme weather scenarios and evaluate the impact on infrastructure fragility. Due to the proprietary nature of power network topology, a distribution network is synthesized using publicly available data. To generate the weather scenarios, an extreme weather generation method is developed. To enhance resilience, renewable resources such as solar panels and energy storage systems (batteries in this study) are incorporated. A customized Genetic Algorithm is proposed to determine the optimal locations and capacities for solar panels and battery installations, maximizing resilience while balancing cost constraints. Experiment results demonstrate that on a large-scale synthetic distribution network with more than 300,000 nodes and 300,000 edges, the proposed framework can efficiently evaluate the resilience, and enhance the resilience through the installations of distributed energy resources (DERs), providing utilities with valuable insights for community-level power system resilience estimation and enhancement.

Wang, Xuesong [Wayne State Univ., Detroit, MI (Uni

Machine Learning-Assisted Distribution System Network Reconfiguration Problem

High penetration from volatile renewable energy resources in the grid and the varying nature of loads raise the need for frequent line switching to ensure the efficient operation of electrical distribution networks. Operators must ensure maximum load delivery, reduced losses, and the operation between voltage limits. However, computations to decide the optimal feeder configuration are often computationally expensive and intractable, making it unfavorable for real-time operations. This is mainly due to the existence of binary variables in the network reconfiguration optimization problem. To tackle this issue, we have devised an approach that leverages machine learning techniques to reshape distribution networks featuring multiple substations. This involves predicting the substation responsible for serving each part of the network. Hence, it leaves simple and more tractable Optimal Power Flow problems to be solved. This method can produce accurate results in a significantly faster time, as demonstrated using the IEEE 37-bus distribution feeder. Compared to the traditional optimization-based approaches, a feasible solution is achieved approximately ten times faster for all the tested scenarios.

deep neural networks