Search NASA⌕ Search

SEARCH · Search NASA

Results for “district”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a Sizing and Modeling Platform for District Energy Systems with Geothermal Heat Pumps

Existing tools for community or urban scale energy system modeling and simulation are often limited in their capabilities and require expert-level modeling proficiency to develop system models. To fill this gap, this paper proposes an integrated sizing and modeling platform for district energy systems with geothermal heat pumps. The proposed platform takes in geometric and non-geometric user inputs related to the buildings, borefield, and district energy loop. Then, the platform sizes the geothermal heat exchanger, generates a corresponding district energy system model, and runs an annual simulation automatically. We validated the simulation performance of the borefield in our tool against EnergyPlus. A case study is provided in this paper to demonstrate the workflow and simulation result plausibility of the proposed platform.

decarbonization↗

Hybrid Solar Thermal Energy System for District Heating Application

Solar district heating (SDH) systems can be good alternatives to conventional systems when they are optimized with hybrid configurations and thermal energy storage (TES). In this scope, a hybrid renewable thermal energy system (RTES) model has been built combining flat plate collector (FPC) solar system with parabolic trough collector (PTC) system via a heat exchanger and coupled with TES. To undertake the hybridization of the system, System Advisor Model (SAM) software was modified, which allowed control over configurations and more accurate modelling of heat transfer between the collectors. The model is first compared to an existing hybrid solar district heating systems (DHS) system in Taars, Denmark. The results showed a good correlation with an overestimation of only 6.4% compared to most recent heat output. Then the same system configuration was modeled in different geographic locations to investigate the impact of changes in direct normal irradiance (DNI) to the heat sink thermal output of the hybrid system. The results showed that the annual net thermal power output in California, USA can be three times more than the annual net thermal power output in Taars, Denmark. Finally, multiple hybrid configurations with varying solar field sizes were simulated based on the heat demand of two different university campuses DHS. The results showed that, retrofit applications of this hybrid DHS system coupled with TES could reduce the natural gas consumption of the existing systems between 25% and 41%. The use of hybrid RTES highlighted in this paper can be extended to many more opportunities.

district heating↗

Overview of NLR Automated Mobility District Implementation Research - Phases I, II, and III. The Convergence of Automation, Electrification, and On-Demand Services: Enabling Resilient Automated Mobility Districts

A research program by the National Renewable Energy Laboratory has been investigating the implementation prospects for fully automated passenger transport systems that are deployed to operate within dense urban settings, referred to as Automated Mobility Districts (AMDs). An AMD emphasizes the deployment of automated vehicles (AV) passenger transport services within a dense urban setting and other major activity centers with intense passenger origin-destination demand patterns, such as those found in large business districts, airports, and university and medical campuses. Phase I and II surveyed 10 early deployment sites and subsequently collected and evaluated the lessons learned from these early deployment sites, with particular attention to fleet operations, impacts of service reliability, and vehicle technology evolution as the field of companies was being progressively winnowed by the challenges of full automation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Architectural Survey of the U12G Tunnel Historic District, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), in conjunction with the National Nuclear Security Administration Nevada Field Office (NNSA/NFO), proposes to demolish six buildings and three storage areas located at the U12g Tunnel portal area in Area 12 of the Nevada National Security Site (NNSS). The buildings are 12-358 (Signal Vault); 12-201800 (Storage Quonset Hut); 12-202555 (Walker Shack); 12-868 (Pipe Assembly); 12-B100933 (Electrical Shop); 12-B100944 (Conference Room); and Storage Area 1; Storage Area 2; and Storage Area 3. The buildings and storage areas were selected for demolition as part of the DOE’s Real Property Efficiency Plan to reduce the footprint of unused and non-operational facilities on the NNSS. They are all vacant and have no proposed uses for current or upcoming NNSS missions. Demolition activities constitute an undertaking subject to review under Section 106 of the National Historic Preservation Act (NHPA) (54 United States Code [USC] § 306101) and its implementing regulations, 36 Code of Federal Regulations (CFR) Part 800. Identification efforts began with resources proposed for demolition in federal Fiscal Year (FY) 23. Four buildings were proposed to be demolished in FY23 (12-358, 12-868, 12-201800, and 12-202555). These buildings and the U12g Tunnel Historic District (SHPO No. D444) were recorded in Identification, Evaluation, and Finding of Adverse Effect for the Proposed Demolition of Five Buildings in Area 12, Nevada National Security Site, Nye County, Nevada (Menocal et al. 2023). Identification efforts indicated three buildings (12-358, 12-201800, and 12-868) supported nuclear testing in the U12g Tunnel. The fourth building post-dated the use of U12g Tunnel for nuclear testing activities. The report recommended that three of the four buildings (12-358, 12-201800, 12-868) and the U12g Tunnel Historic District may be eligible for the National Register of Historic Places (NRHP). The report also found that the undertaking would have an adverse effect on the three buildings and on the historic district. The Nevada State Historic Preservation Office (SHPO) concurred with the report’s findings (Reed 2023). The U12g Tunnel was determined eligible as a historic district under the Secretary of the Interior’s (SOI) Significance Criterion A, at the local level, in the context of the Cold War as an underground testing environment for the development of nuclear weapons and to assess the effects of a nuclear explosion on materials and equipment with a period of significance from 1959 to 1971. It was also determined eligible under Significance Criterion C for embodying the distinctive characters of a horizontal tunnel complex used for nuclear testing and as a significant and distinguishable entity. The three buildings were determined to be contributing elements of the district. The undertaking was expanded with the addition of two buildings and three storage areas proposed to be demolished and located within U12g Tunnel Historic District in FY24. These five resources (12-B100933, 12-B100944, and Storage Areas 1, 2, and 3) were recorded in Supplemental Identification, Evaluation, and Finding of Effect for Additional Proposed Demolition at U12g Tunnel, Area 12, Nevada national Security Site, Nye County, Nevada (Brannan et al. 2024). Identification efforts indicated that the two buildings and Storage Area 1 supported nuclear testing in the U12g Tunnel. Storage Area 1 and Storage Area 2 post-dated the nuclear testing activities at U12g Tunnel and were not recommended as contributing elements to the district. The report also found that the undertaking would have an adverse effect on the newly identified buildings and one storage area and on the historic district. The SHPO concurred that the expanded undertaking would result in adverse effects to historic properties (Reed 2025). To resolve these adverse effects, NNSA/NFO, in consultation with the SHPO, is following standard mitigation as stipulated in the 2024 Programmatic Agreement DE-GM58-22NA25554 Among the U.S. Department of Energy and the Nevada State Historic Preservation Officer and the Advisory Council on Historic Preservation Concerning the Protection of Historic Properties on the Nevada National Security Site, Nye County, Nevada (hereafter referred to as the NNSS PA). The standard mitigation measures are outlined in Appendix D of the NNSS PA. As such, this architectural survey has been prepared in accordance with Appendix D of the NNSS PA and follows the report format outlined in Appendix F. It includes a historic context that describes the district’s origin, history, and support functions, its significance in the context of nuclear testing on the NNSS, and identifies contributing and non-contributing elements within the district. The report is accompanied by Architectural Resource Assessment (ARA) forms for individual resources and a Historic District Resource Assessment (HDRA) for the U12g Tunnel Historic District. In total, this architectural report identified 32 primary resources within the district boundary. Six of the primary resources were previously identified as contributing elements. An additional 17 resources are recommended as contributing elements to the district for a total of 23 contributing elements. The other nine resources identified are recommended as non-contributing elements to the district.

12-201800↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

Development of Prototypical District-Scale Models

The U.S. has set the climate goal to achieve net-zero greenhouse gas emissions by 2050. District-scale solutions, which include scale-specific opportunities for energy and emissions savings, can be investigated and implemented to help accelerate decarbonization and progress toward this goal. However, there is currently a lack of district-scale models of buildings and community energy systems that can be used to evaluate potential district-scale technologies and strategies across a range of representative community types. This initial work aims to define and develop prototype district models that can be adapted to support the planning, design, and operation of buildings and energy systems in districts considering the complexity and interactions of diverse building loads, weather impacts, distributed energy resources (e.g., PV, EV, electric and thermal energy storage), electric and thermal grid systems, and pricing signals. An overall workflow for developing these prototype district models is established. Stakeholders and potential users of the prototype district models provided technical feedback. The specifications of the selected high priority districts were defined and documented in a scorecard format. An example prototype district model was implemented with the URBANopt platform workflows. A case study was performed to demonstrate the model application.

building energy modeling↗

Optimizing district energy systems under uncertainty: Insights from a case study from Washington D.C., USA

This study investigates solutions for delivering affordable heating and cooling to a brownfield site, focusing on a case study in Washington, DC. Moving towards more diverse and resilient energy systems, we identify the optimal portfolio for a district energy system with diverse energy sources to meet the area’s energy demands. Our methodological approach integrates two detailed models: one calculating building-level energy demand and the other optimizing district energy technology choices based on their demand profiles, accounting for uncertainties in energy prices, policies, and other parameters. The results provide an economic comparison of district and individual supply options at the building level, emphasizing the flexibility district systems can offer to the electricity sector. District energy systems demonstrate cost-stabilization benefits amidst volatile energy prices and external uncertainties. For heating, district systems yield significant cost savings compared to individual solutions, driven by fuel flexibility and the use of local renewable energy sources. For cooling, district systems also show advantages, though individual systems may remain more cost-effective for smaller buildings. Additionally, district systems exhibit considerable flexibility on the heating side, as evidenced by variations in electricity consumption. We recommend future research to explore the relationship between the economics of district energy systems, particularly at the building level, and their flexibility potential for the electricity sector across diverse geographic contexts to reduce overall grid costs and promote grid reliability. This includes areas with distinct zoning laws, municipal priorities, utility structures, and funding mechanisms, such as the United States, and regions like Europe with pronounced electricity price volatility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of Prototypical District-Scale Models: Preprint

The U.S. has set the climate goal to achieve net-zero greenhouse gas emissions by 2050. District-scale solutions, which include scale-specific opportunities for energy and emissions savings, can be investigated and implemented to help accelerate decarbonization and progress toward this goal. However, there is currently a lack of district-scale models of buildings and community energy systems that can be used to evaluate potential district-scale technologies and strategies across a range of representative community types. This initial work aims to define and develop prototype district models that can be adapted to support the planning, design, and operation of buildings and energy systems in districts considering the complexity and interactions of diverse building loads, weather impacts, distributed energy resources (e.g., PV, EV, electric and thermal energy storage), electric and thermal grid systems, and pricing signals. An overall workflow for developing these prototype district models is established. Stakeholders and potential users of the prototype district models provided technical feedback. The specifications of the selected high priority districts were defined and documented in a scorecard format. An example prototype district model was implemented with the URBANoptTM platform workflows. A case study was performed to demonstrate the model application.

district↗

Nexus of electrification and energy efficiency retrofit of commercial buildings at the district scale

Rapid electrification of buildings at the district scale is needed for cities to achieve climate change mitigation goals. However, most electrification studies focus on either the single building level or the city/region building stock level, and depend on the slow and uncertain process of requesting personally identifiable customer energy usage data from utilities. To answer a key question facing local policymakers: “Where can electrification proceed at scale without first upgrading the grid?” this study aims to quantify and inform building electrification impacts at the district scale using detailed building energy modeling and based on public records datasets. We explore how energy efficiency retrofits can help mitigate increased peak electric demand, and quantify impacts to energy use and carbon emissions. Building energy models of a baseline, and scenarios of simple electrification, energy retrofits, and electrification in combination with retrofits were created and simulated for 54 commercial buildings in two contiguous districts of San Francisco. A simple electrification scenario increased annual electricity consumption but reduced annual site energy usage by 15% to 17%, mainly due to replacing inefficient gas furnaces and boilers with more efficient heat pumps. Peak demand increased 7.4% for Fisherman's Wharf (e.g. within the capacity of the existing power grid), while the Design District showed a marginal decrease. Annual carbon emissions were reduced by 46% and 37%. Combining electrification with efficiency upgrades reduced peak demand by 26% and 40%, and annual carbon emissions by 63% and 64% for the two districts. Furthermore, these results indicate that impacts of electrification depend on the mix of building uses within a district, and coupling electrification with energy efficiency upgrades is an effective strategy to decarbonize buildings while maintaining or reducing the peak electric demand.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Energy Topics for Hill District Community Leaders [Slides]

Through Communities LEAP, a community coalition focused on the Hill District neighborhood of Pittsburgh is working with a technical assistance provider network led by the National Renewable Energy Laboratory (NREL). The coalition includes community organizations, nonprofits, the city government, and the utility. Technical assistance provides analysis and information to support Hill District stakeholders in their goals to create informed residential energy efficiency and renewable energy transition strategies that improve housing conditions and lower energy bills, incorporate energy efficiency and renewable energy strategies into existing, community-driven development efforts, and generate quality local jobs. The Advanced Energy Topics resource is intended to support Hill District community leaders with strategic planning on energy-related topics. The topics included are intended to serve as a technical reference for community leaders to help inform decision-making around energy. The Advanced Energy Topics resource was informed by engagement through the Communities LEAP pilot program with three Hill District Registered Community Organizations: the Hill District Collaborative, the Hill District Consensus Group, and the Hill Community Development Corporation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

District heating utilizing waste heat of a data center: High-temperature heat pumps

Data centers are energy-intensive facilities with substantial low-grade waste heat. High-temperature heat pumps can be critical in boosting the data center’s waste heat for district heating, improving the system-level energy efficiency of data centers, and reducing CO 2 emissions in district heating. This study built thermodynamic models to assess high-temperature heat pumps with six configurations using low global warming potential refrigerants to supply heat up to 120 °C. The heat pump configurations include single-stage or two-stage cycles with advanced components, such as internal heat exchanger, economizer, flash tank, or parallel compressor. The refrigerants include R1234ze(Z), R1233ed(E), R1224yd(Z), R600, and R600a, and R245fa is used as a reference. A case study was carried out to recover the waste heat from the Frontier high-performance computing data center and provide hot water for district heating at the US Department of Energy’s Oak Ridge National Laboratory campus. The optimized performance of high-temperature heat pumps is characterized with various effectiveness of internal heat exchangers, and the operating parameters of economizer or flash tank, as well as their combination. The results show that the configurations of two-stage cycles with internal heat exchanger + flash tank and internal heat exchanger + economizer/parallel-compressor provide the highest coefficient of performance under scenarios of the maximum allowable value and a fixed value (0.3) of the internal heat exchangers’ effectiveness, respectively. R1234ze(Z) and R600a are the most promising refrigerants, considering trade-offs between the coefficient of performance and the volumetric heating capacity. The single-stage cycle with internal heat exchanger + economizer/parallel-compressor using R1234ze(Z) is recommended for utilizing Fronter’s waste heat in district heating. A one mega-watt high-temperature heat pump will reduce 33,100–33,200 metric tons of CO2 emission annually, corresponding to 85.4 %–85.6 % of equivalent CO2 emissions from natural gas boilers. Here, this study provides good guidelines for designing and deploying high-temperature heat pumps to support sustainable data centers and decarbonize district heating in the US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Techno-economic feasibility of geothermal energy production using inactive oil and gas wells for district heating and cooling systems in Tuttle, Oklahoma

Oil and gas wells have been drilled in the United States and often encounter hot co-produced water possibly suitable for geothermal direct-use applications. Here this study evaluated geothermal resources, heating and cooling demand, and techno-economic potential of four oil and gas wells repurposed for geothermal energy production to serve two public schools and 250 nearby houses in Tuttle, Oklahoma, USA. Subsurface geology in the study area primarily consists of Permian to Mississippian sandstone and limestone formations approximately from 2 km to 3.5 km depth. With a geothermal gradient of 25.3 °C/km, the temperature of geothermal energy production was estimated as 68.2 °C at 2.1 km. The potential of calcite scaling within boreholes and pipes was minimal. Using the characterized reservoir properties, techno-economic analyses were conducted for evaluating levelized costs of geothermal energy production for direct-use heating and cooling and district heating systems with five different production scenarios. Heating and cooling demand in two schools and 250 houses and additional 0.3 MW and 0.6 MW base heating loads for potential geothermal direct-use applications in the study area were also incorporated in the modeling. Results indicated that the levelized cost of heating of geothermal district heating systems utilizing existing wells were significantly lower than those of conventional geothermal energy systems that include well drillings. The geothermal energy production with doublet and quartet configurations was generally sufficient to supply total annual heating demand in the district, while a peaking boiler was used to supply peak loads. Doublet configurations showed higher production temperature with a lower thermal drawdown than the quartet configurations. The doublet system at 2.1 km production depth with 9.3 kg/s flow rate represented the optimal levelized cost of $71/MWh and 91.2% utilization factor. These results imply that the Tuttle geothermal district heating system is techno-economically feasible and comparable to geothermal district heating systems in the United States and the regional natural gas rate for residentials by recycling inactive oil and gas wells with no drillings.

15 GEOTHERMAL ENERGY↗

Optimal operation of multi-plant steam district heating systems for enhanced efficiency and sustainability

Despite their crucial role in supplying heat and power to universities, industries, and healthcare facilities, many steam-based district heating systems rely on outdated control methods. Among these, multi-central plant districts are particularly challenging due to the complexities of coordinating multiple plants, optimizing load distributions, and managing system downtime. In response, new operational strategies are developed to enhance the efficiency and sustainability of steam districts while utilizing existing resources. These strategies include reducing plant operational pressure without compromising the reliable supply to buildings and optimizing load allocation across multiple plants. The load allocation considers boiler part-load efficiency, runtime, network losses, and building pressure set points, and is compared with traditional multi-boiler controls. To support this exploration, new dynamic Modelica models are developed. In addition, methods to reduce modeling complexities are incorporated, enhancing their suitability for practical applications. A holistic district-wide analysis using a real university case study demonstrates a 4.7% fuel savings by lowering boiler operational pressure from 900 kPa to 600 kPa, along with a 13.3% reduction in condensation losses across the distribution network. Furthermore, the load allocation approach results in a 13.1% reduction in fuel consumption during peak winter periods and 15.3% during shoulder periods, with corresponding decreases in carbon emissions and fuel costs. This approach can also save maintenance costs by reducing the boiler runtime by 49.6%. In conclusion, this research underscores the benefits of retrofitting aging steam district heating systems, offering immediate operational improvements by enhancing efficiency, meeting regulatory compliance, and extending infrastructure lifespans while delaying costly overhauls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Life Cycle Assessment for Evaluating the Global Warming Potential of Geothermal Energy Production Using Inactive Oil and Gas Wells for District Heating in Tuttle, Oklahoma

Repurposing abandoned oil and gas infrastructure for geothermal energy production has great potential to reduce greenhouse gas (GHG) emissions. This study quantified the life cycle global warming potential of geothermal energy production using four inactive oil and gas wells repurposed for district heating in Tuttle, Oklahoma. A cradle-to-grave prospective life cycle assessment was performed to compare GHG emissions between the geothermal district heating system and conventional natural gas-fired heating system from 2020 to 2050. For initial implementation of the geothermal system, we investigated two approaches: 1) repurposing abandoned infrastructure from a nearby oil and gas well site, and 2) production and injection well drillings including new construction of a central heat exchange station. Environmental impacts from the geothermal system were estimated for five scenarios where a natural gas peaking boiler is incorporated to supply peak heat demand. The prospective results indicated that cumulative reduction in GHG emissions from transitioning to the geothermal district heating system increase over time as a function of future renewable resource penetration and technological advancements within electricity, fuel, and steel production. Over 30 years, the global warming potential associated with the district heating demand will have been reduced by up to 24 % with the repurposed system. These results imply that repurposing existing oil and gas infrastructure for geothermal energy systems of district heating will bring future climate benefits.

abandoned oil and gas wells↗

Winnett Public School District Energy Improvements

The Winnett Public School District Energy Improvement Project was funded through the U.S. Department of Energy's Renew America's Schools Program, which supports rural and underserved school districts in upgrading aging facilities and improving energy performance. The completed improvements directly advance the program's objectives by replacing the District's outdated coal-fired heating system with a modern, high-efficiency propane boiler system, while also enhancing ventilation systems and building envelope performance throughout the school. These upgrades provide a more reliable heating system and improved indoor air quality, creating a healthier and more comfortable environment for students and staff. In addition, replacing the aging boiler system has reduced long-term maintenance demands for one of Montana's most rural school districts, allowing the District to redirect limited financial resources toward other critical needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Clean Energy Workforce and Employment Gap Analysis in the Hill District of Pittsburgh, PA [Slides]

Through Communities LEAP, a community coalition focused on the Hill District neighborhood of Pittsburgh is working with a technical assistance provider network led by the National Renewable Energy Laboratory (NREL). The coalition includes community organizations, nonprofits, the city government, and the utility. Technical assistance provides analysis and information to support Hill District stakeholders in their goals to create informed residential energy efficiency and renewable energy transition strategies that improve housing conditions and lower energy bills, incorporate energy efficiency and renewable energy strategies into existing, community-driven development efforts; and generate quality local jobs. This presentation provides a summary of potential employment impacts of residential energy efficiency investments in the Hill District, aligned with NREL's housing stock analysis; a scan of existing energy efficiency and clean energy workforce and education stakeholders in and around the Hill District; and gaps and potential opportunities for new or expanded training to align with energy efficiency and clean energy goals.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Geothermal Direct-Use Applications for the District Energy System in Bucharest, Romania

The city of Bucharest, Romania, hosts the second-largest district energy system (DES) in the world. Geothermal resources can be considered as a supplementary heat source to support the demand for domestic hot water and space heating in the winter and shoulder seasons. The National Laboratory of the Rockies (NLR) has conducted a study that considers geothermal energy to serve a fraction of the existing district heating network operated by Electrocentrale Bucure?ti (ELCEN), the utility operating the DES. Lower Cretaceous and Jurassic limestones make up the main geothermal aquifer underlying Bucharest, which hosts temperatures suitable for district heating (up to 90 degrees C to the north of the city). Anomalous geothermal gradients have been observed to the north of the city, where a pumped well has produced 82 degrees C brine at the wellhead to feed the Therme Bucharest Spa. An anomalous gradient has also been reported to the southeast of the city (35 degrees C/km). NLR modeled the building heating loads of a small portion of the DES (a block of nine prototypical buildings) in its Urban Renewable Building and Neighborhood Optimization (URBANopt ) platform. To simulate meeting a baseload benchmark of 20 MWth deliverable to a small portion of the DES, the NLR team used GEOPHIRES to model production scenarios for (1) hydrothermal systems coupled with heat pumps targeting the main geothermal aquifer in the north, (2) enhanced geothermal systems targeting hot dry rock in the southeast, and (3) huff-and-puff systems targeting a gradient of 25 degrees C/km. Finally, NLR conducted a high-level sensitivity study around the techno-economics of these systems. The outcomes of this work indicate that hot dry rock geothermal resources that can deliver at least 90 degrees C hot water to the Geothermal District Energy System (GeoDES) offer a possible solution for supplemental geothermal heat delivered to the existing DES.

15 GEOTHERMAL ENERGY↗