Search NASA⌕ Search

SEARCH · Search NASA

Results for “disturbance rejection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Multilevel Conditional Disturbance Rejection Control for Satellite Attitude Tracking

Recently, the conditional disturbance rejection controller (CDRC) was proposed to improve control performance by leveraging disturbances that have beneficial effects on the system. However, it only considers disturbances acting on the state variable directly influenced by them. Although fast convergence of this state can be achieved with the CDRC, it may unintentionally affect the convergence of the output (i.e., the primary state). Here, in this article, a multilevel CDRC is proposed to enhance satellite attitude control performance by accounting for the effect of disturbances on both attitude (output) and angular velocity. The extended state observer is employed to estimate the lumped disturbance, including the modeling errors and external disturbances. Then, a backstepping-based controller with the multilevel disturbance rejection law (ML-DRL) is designed for attitude tracking. The ML-DRL is developed to improve the control performance by using a disturbance with a damping effect on both attitude and velocity. Faster convergence of attitude and velocity can be achieved by conditionally compensating for the disturbance. The stability of the proposed control method is analyzed by demonstrating that the errors are bounded as time tends to infinity. The attitude control performance of the proposed method is evaluated through numerical examples conducted using the MATLAB/Simulink Multibody tool.

Active disturbance rejection control (ADRC)↗

Robust Disturbance Rejection Rotor Current Control of Doubly-Fed Induction Generators

This article proposes a robust transient disturbance rejection current controller (TDRCC) to improve the transient performance of doubly-fed induction generators (DFIGs) in wind turbines during grid disturbances, such as short circuits. Here, the proposed robust TDRCC replaces the proportional-integral-derivative (PID) current controllers conventionally used in the vector control scheme of the DFIG rotor side converter (RSC). The TDRCC estimates the transient disturbances caused by grid faults or other external disturbances and provides compensation to the DFIG rotor voltage in the current control loops of the RSC to improve the robustness of the controller to disturbance. A sliding-mode current controller (SMCC) is also designed to highlight the transient performance improvement of the DFIG using the TDRCC over the state-of-the-art control methods during grid short circuit faults. Simulation studies are conducted in PSCAD/EMTDC for a 3.6-MW DFIG wind turbine with the proposed TDRCC, the conventional PI controller, and the SMCC, respectively during the most severe balanced three-phase grid short circuit fault specified by the U.S. grid code as well as an unbalance single-phase grid short circuit fault. Hardware experiments are conducted on a 200-W DFIG wind turbine emulator with the three different controllers for the same three-phase short circuit fault. Simulation and hardware experiment results show that the TDRCC reduces the peak rotor current significantly when compared with the PI and SMCC controlled DFIG system and, therefore, would help prolong the lifespan of the DFIG's power electronics and reduce maintenance costs.

42 ENGINEERING↗

A Reinforcement Learning Approach to Augment Conventional PID Control in Nuclear Power Plant Transient Operation

The ability of nuclear reactors to operate their power conversion cycles more flexibly will enhance their value to energy grids with variable pricing. Current nuclear control systems are typically classical controllers that are often based on proportional-integral-derivative (PID) control. This paper presents a method of augmenting the existing PID control for difficult transient operations in nuclear power plants using a reinforcement learning–derived feedforward signal applied in real time. The agents, which are trained on a test thermal load-following problem, are designed to improve steam generator outlet temperature control for a range of fast load-following scenarios covering ramp rates from 9%/min to 15%/min. Several reinforcement learning algorithms were initially investigated for the training of the feedforward agents with deep Q-learning (DQN) and proximal policy optimization (PPO) networks, which were found to be the most promising. The DQN controllers utilize discrete actions, giving them a better disturbance rejection at steady state but inconsistent response to initial temperature deviations. In contrast, PPO-trained agents, which take continuous actions except for a dead zone around zero, were shown to have the best combination of high disturbance rejection at steady state and good tracking of the desired temperature value. The ability of the PPO agent was also examined, with the average time of decision making found to be on the order of 1 ms. The fault properties of the controller under the loss of the reinforcement learning agent feedforward signal were also examined. The controller showed strong performance in situations of “no-signal” faults. but was less good at handling “stuck-at” faults, where the feedforward signal remains at a set value. In both cases, however, the PID was able to successfully maintain stability, eventually returning the system to a steady state. It is hoped that this work will allow for the proposed control architecture to be examined for more difficult control problems such that it may eventually be used to adapt existing nuclear plants for more aggressive load-following on grids of the future.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental Performance of a Nonlinear Control Strategy to Regulate Temperature of a High-Temperature Solar Reactor

Abstract Despite the significant potential of solar thermochemical process technology for storing solar energy as solid-state solar fuel, several challenges have made its industrial application difficult. It is important to note that solar energy has a transient nature that causes instability and reduces process efficiency. Therefore, it is crucial to implement a robust control system to regulate the process temperature and tackle the shortage of incoming solar energy during cloudy weather. In our previous works, different model-based control strategies were developed namely a proportional integral derivative controller (PID) with gain scheduling and adaptive model predictive control (MPC). These methods were tested numerically to regulate the temperature inside a high-temperature tubular solar reactor. In this work, the proposed control strategies were experimentally tested under various operation conditions. The controllers were challenged to track different setpoints (500 °C, 1000 °C, and 1450 °C) with different amounts of gas/particle flowrates. Additionally, the flow controller was tested to regulate the reactor temperature under a cloudy weather scenario. The ultimate goal was to produce 5 kg of reduced solar fuel magnesium manganese oxide (MgMn2O4) successfully, and the controllers were able to track the required process temperature and reject disturbances despite the system's strong nonlinearity. The experimental results showed a maximum error in the temperature setpoint of less than 0.5% (6 °C), and the MPC controller demonstrated superior performance in reducing the control effort and rejecting disturbances.

Energy & Fuels↗

A Single-Stage Multilevel AC-DC Bidirectional Converter With Natural Grid Harmonic Elimination

Generally, AC-DC converters have an AC-DC stage followed by a DC-DC stage. In these two stage approaches, the AC-DC stage is hard-switched, whereas the DC-DC stage is soft-switched. Therefore, the devices in the AC-DC stage can be switched only at tens of kHz to avoid excessive switching losses, thus limiting the bandwidth of the current control loop. Hence, the control of these converters with distorted grid voltages requires multiple harmonic compensation loops or other complex control algorithms in order for the grid currents to comply with IEEE standards. By integrating both the stages, the devices in the AC-DC stage can also be soft-switched, thus facilitating higher switching frequency, and thereby higher current control bandwidth. This paper proposes an integrated multilevel bidirectional AC-DC converter with improved control bandwidth and disturbance rejection. It is shown experimentally that the high bandwidth current control loop of the converter can reject grid harmonic current disturbances, without the need for any compensation loops or complex control techniques, and comply with IEEE standards.

30 DIRECT ENERGY CONVERSION↗

Model predictive combustion control of a Gasoline Compression Ignition engine

Gasoline Compression Ignition is a novel combustion concept that derives its superiority from the high compression ratio of a compression ignition engine as well as the properties of gasoline fuel, such as longer ignition delay and higher volatility compared to diesel. Here, this combustion concept was experimentally tested on a 12.4L Class 8 truck engine. Based on these experimental data, prior efforts by the authors focused on the development of an engine model for a heavy-duty engine operating on a low-reactivity fuel. This engine model was leveraged within this study to investigate a combustion control strategy at different engine conditions and injection methods and was augmented to incorporate cycle-to-cycle combustion variations. State estimation is performed by means of a Kalman filter which feeds into a model predictive controller. The model predictive controller chooses control actions based on a predefined cost function under consideration of bounds reflecting physical constraints. The engine model was utilized to establish a state-space model that serves the Kalman filter and model predictive controller for estimation and prediction. A comparative study investigating control actions and engine behavior was performed with and without limiting in-cylinder peak pressure as well as combustion noise, which is of particular interest for early pilot injection strategies. In addition, the proposed control architecture was investigated at two different levels of cycle-to-cycle variations and compared to the performance of a control structure with input disturbance rejection. For increased cycle-to-cycle variations, disturbance estimation reduces state fluctuations and control effort. In general, this investigation highlights control aspects specific to a compression-ignited combustion regime with low-reactivity fuel. The control algorithm is able to maintain the desired references for brake mean effective pressure and combustion phasing while controlling peak in-cylinder pressure and combustion noise.

42 ENGINEERING↗

Transient Optimization of the Cryogenic Moderator System Controller at the Spallation Neutron Source for Improved Performance

The high-energy neutron beam generated at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is moderated to use cold (slow) neutrons for scientific discoveries. The Cryogenic Moderator System (CMS) removes heat from the neutron beam using cryogenic hydrogen (H 2 ) moderators connected via heat exchangers to a helium (He) refrigeration loop that dissipates heat using a compressor-brake system. However, the CMS is affected by sporadic losses in beam power, referred to as "beam trips," as these events generate significant disturbances in cooling requirements. To accommodate the heat load transients during beam trips, the CMS uses a decentralized control strategy consisting of four flow valves and one electric heater adjusted by independent proportional-integral (PI) controllers. During the CMS’s initial commissioning, the PI gains were calibrated based only on tracking performance, overlooking their effectiveness in disturbance rejection. A data-driven, control-oriented closed-loop model was developed to recalibrate the PI gains and minimize the transient disturbances caused by beam trips. The model consists of three main components: (1) a physics-based model of the He refrigeration loop, (2) a machine-learning model of the cryogenic H 2 cooling trains, and (3) the control logic used for feedback set-point tracking. Experimental results showed that the recalibrated gains obtained in this study improved the CMS’s transient response during beam trips.

Maldonado Puente, Bryan↗

Robust constrained tension control for high-precision roll-to-roll processes

Tension control is critical for maintaining good product quality in most roll-to-roll (R2R) production systems. Previous work has primarily focused on improving the disturbance rejection performance of tension controllers. Here, a robust linear parameter-varying model predictive control (LPV-MPC) scheme is designed to enhance the tension tracking performance of a pilot R2R system for deposition of materials used in flexible thin film applications. The performance of a tension controller may degrade due to disturbances associated with model uncertainties and the slowly-changing dynamics in R2R systems. We introduce a method that separately treats these two sources of disturbance. The controller utilizes an incremental model to eliminate the errors caused by the mismatch between the nominal model and the actual system. A tube-based MPC formulation combined with scheduled parameters adequately updates models and corrects for the time-varying dynamics. Constraints on the rated motor torque are incorporated in the MPC to maintain the controller reliability and avoid machine failures. We illustrate the operation of our control algorithm through simulation of an actual R2R system. The controller outperforms the benchmarks in terms of fast transient response and offset-free tension tracking. Furthermore, it also demonstrates immunity from variations due to parametric uncertainties.

42 ENGINEERING↗

The Ponderomotive Effects of Narrow-band, Superconducting Resonators in Open and Closed Loop

In this work, we present measurements of ponderomotive instabilities in narrow-band, coaxial resonators in open and closed control loop systems. We show an analytical scheme we will use in future studies to examine the dependency of open loop stability on mechanical parameters. Analytical and simulation models are used to predict the onset of the oscillatory instability in half wave resonators with active disturbance rejection control for amplitude and phase stabilization. We demonstrate that for high amplitude controller bandwidths, ponderomotive oscillations can couple with the controller frequency response via higher harmonics and lower the threshold for the oscillatory instability. We reaffirm the superiority of in-phase/quadrature $(I/Q)$ component control in regards to preventing the oscillatory instability, and show how the phase controller can amplify the crosstalk of disturbances in amplitude and phase control. In cases with large disturbances, this effect can lead to instabilities not present in $I/Q$ control.

Brown, Jacob [Michigan State U.; Fermilab] (ORCID:↗

Real-time estimation of the electron temperature profile in DIII-D by leveraging neural-network surrogate models

Control of both the magnitude and the shape of tokamak profiles will be necessary to achieve stable, high-performance plasmas. In order to reject disturbances in real time, feedback-control algorithms rely on accurate real-time knowledge of the plasma state. When diagnostics alone are insufficient, either because they are limited in number or their measurements are too noisy, observers can be used to combine diagnostic data with a response model to provide a better estimation of different plasma properties. An observer has been developed to estimate the electron temperature profile in real time using both diagnostic data from the Thomson scattering system and a model based on the electron heat transport equation describing the evolution of the electron temperature profile. Here, neural network surrogate models are leveraged to help improve the overall model prediction while staying within computation time constraints for real-time use. The observer algorithm is shown in offline tests to produce smooth profiles that are consistent with both the diagnostic data and the electron heat transport equation. When implemented into the real-time plasma control system, this observer will provide valuable information on the electron temperature profile to many potential feedback-control applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Robust Data-Driven Approach for Mechanical Serial Sectioning

Mechanical serial sectioning (MSS) provides detailed microstructural information across large length scales. By repeatedly removing thin layers of material and imaging the exposed surface, a 3D representation of a specimen’s internal structure can be constructed, enabling failure analysis and feature identification that are otherwise inaccessible via conventional 2D or nondestructive evaluation techniques. Achieving consistent and accurate material removal can be challenging due to system variability, requiring an experienced operator to manually adjust parameters, prolonging data collection times and necessitating post-processing routines to standardize the data. Here, to address these challenges, this paper presents the employment of a one-step model predictive control (MPC) framework tailored to a run-to-run (R2R) controller. The R2R-MPC controller automates the parameter selection process, improving the consistency of material removal through iterative feedback for disturbance rejection and accurate tracking of the target removal rate. Using a data-driven approach, the controller robustly adapts to changing material characteristics. The effectiveness of the R2R-MPC controller is demonstrated through simulation and experimental results and compared to previous data collection procedures.

3D Materials Science↗

Data-Driven Modeling of a High Capacity Cryogenic System for Control Optimization

The Cryogenic Moderator System (CMS) is responsible for maintaining a steady flow of cold neutrons for numerous physics experiments at the Spallation Neutron Source (SNS) in Oak Ridge National Laboratory (ORNL). Sudden losses in beam power, known as beam trips, cause a major disturbance to the CMS due to large step changes in cooling demands. Ongoing efforts on upgrading the neutron beam power from 1.4 to 2.0MW are expected to generate larger transients that can further strain the CMS subsystems if they are not properly controlled. To manage such disturbances, four flow valves and one electric heater are adjusted by five decentralized proportional-integral-derivative (PID) controllers. However, the original PID gains were calibrated empirically based only on tracking performance and not based on disturbance rejection. To address this issue without compromising current CMS operations, a control-oriented model was developed to recalibrate the PID controllers offline. The zero-dimensional (0-D) model was based on simple physics-based principles and data-driven system identification techniques. The CMS was broken into several subsystems for analysis, each of which corresponds to a parametric model tied to the thermodynamic states of the working fluid. The model parameters were identified using the nonlinear least squares method where the residuals were calculated from available sensor data. Simulation results show that the proposed model can capture the dynamics of the CMS at steady state and during beam trips.

Maldonado Puente, Bryan↗

Dynamic Modeling and Simulation of a Subcritical Coal-Fired Power Plant under Load-Following Conditions

Dynamic models for power plants that capture realistic general process trends and effects of manipulated variables are needed to improve load-following, while minimizing carbon footprint. In this work, a dynamic modeling approach and simulation results for subcritical coal-fired power plant components are presented. These encompass simulation of the dynamics in the fireside, including the effects of fuel, air combustion, and the dynamics of the entire waterside and power generation sections. This model development enables the simulation and analysis of the important short and long-time scale dynamics of components such as heaters, evaporative loop, and power generation units. Furthermore, additional variables in the power generation section are introduced to improve model accuracy, extending the prediction capability of subcritical power plant models and opening new opportunities for research in operator training, optimization, and advanced model-based controller design that are based on these models. The change in process gain for different ramp rates associated with disturbance signals that affect process variables is also explored and a correlation developed. This provides opportunities to study disturbance rejection control implementation and adaptation for scenarios with such variations in ramp rates. The prediction capabilities of selected components are compared to data available in literature, with the obtained root mean squared error ranges that reflect the model performance and quality of predictions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hierarchical Power Flow Control in Smart Grids: Enhancing Rotor Angle and Frequency Stability with Demand-Side Flexibility

Large-scale integration of renewables in power systems gives rise to new challenges for keeping synchronization and frequency stability in volatile and uncertain power flow states. To ensure the safety of operation, the system must maintain adequate disturbance rejection capability at the time scales of both rotor angle and system frequency dynamics. This calls for flexibility to be exploited on both the generation and demand sides, compensating volatility and ensuring stability at the two separate time scales. This article proposes a hierarchical power flow control architecture that involves both transmission and distribution networks as well as individual buildings to enhance both small-signal rotor angle stability and frequency stability of the transmission network. The proposed architecture consists of a transmission-level optimizer enhancing system damping ratios, a distribution-level controller following transmission commands and providing frequency support, and a building-level scheduler accounting for quality of service and following the distribution-level targets. Furthermore, we validate the feasibility and performance of the whole control architecture through real-time hardware-in-loop tests involving real-world transmission and distribution network models along with real devices at the Stone Edge Farm Microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Virtual Self-Excited Induction Generator-Based Grid-Forming Inverter Control for Robust Voltage Regulation Under Nonideal Loading

This paper presents a generator-inspired control methodology for grid-forming (GFM) inverters that deliberately emulates a self-excited induction generator so that the inverter can hold its voltage and frequency under difficult loading and severe terminal disturbances across wide voltage and frequency ranges. The design integrates a Lyapunov energy function-based inner loop to provide high bandwidth and strong disturbance rejection, and it complements this with a passivity-based argument that furnishes a coherent large-signal stability guarantee beyond small-signal limits. Analytical insights are developed via the Krylov-Bogoliubov-Mitropolsky averaging method, which reveals an intrinsic resistive droop characteristic; these closed-form relations both explain the observed dynamics and yield simple, decentralized tuning rules. The methodology is validated on a controller-hardware-in-the-loop platform and exercised in real time across balanced, unbalanced, and nonlinear loads, as well as during parallel operation. Across these scenarios, the inverter maintains balanced three-phase voltages, limits harmonic content, settles quickly with well-damped transients, and remains resilient when multiple units operate in parallel. The contributions are a self-excited-machine-inspired GFM controller with enhanced dynamic performance and robustness, a single stability rationale grounded in passivity, closed-form expressions that guide tuning, and comprehensive hardware-in-the-loop validations demonstrating effectiveness and superiority under challenging operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nonlinear Multiple Models Adaptive Secondary Voltage Control of Microgrids

This article proposes a model-free secondary voltage control (SVC) for microgrids (MG) using nonlinear multiple models adaptive control. Firstly, a linear robust adaptive controller is designed to guarantee the voltage stability in the bounded-input- bounded-output (BIBO) manner so as to meet the operation requirements of MGs. Secondly, a nonlinear adaptive controller is developed to improve the voltage tracking performance with the help of artificial neural networks (ANNs). A switching mechanism for coordinating such two controllers is designed to guarantee the closed-loop stability while achieving accurate voltage tracking. Here, by an online identification based on the input and output data of MGs, the proposed method does not resort to any apriori information of system model and primary control, thus exhibiting good robustness, ease of deployment and disturbance rejection.

17 WIND ENERGY↗