Search NASA⌕ Search

SEARCH · Search NASA

Results for “dose assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Fukushima Containment Dose Assessment

Dose calculations for a BWR Mark I containment are conducted to complement source term research on the meltdowns at Fukushima Daiichi. These efforts are a primary component of Phase II of the OECD/NEA's Benchmark Study on the Accident at Fukushima Daiichi Nuclear Power Station (BSAF). Phase II of BSAF aims to evaluate radionuclide source terms to the containment and to the environment, radionuclide transport behavior, and dose rates inside and near the plant. The radionuclide-focused goals of Phase II make use of thermal-hydraulic and severe accident insights from Phase I of BSAF, which concentrated on severe accident thermal-hydraulics, core degradation and fuel relocation, reactor pressure vessel (RPV) lower head failure, and containment response. The details and assumptions involved in the severe accident progression have first-order impacts on radionuclide transport and consequent dose rates. An MCNP6 model is created to support the BSAF Phase II investigations. The MCNP6 input represents a boiling water reactor (BWR) Mark I containment and pertinent surrounding structures such the reactor building. This paper examines photon dose rates inside and adjacent to the containment. The spatial distribution and energy spectrum of the source, as well as the overall source magnitude, are informed by MELCOR radionuclide transport calculations in conjunction with ORIGEN-S decay calculations. Initial mesh and ring tally calculations are discussed in relation to plant data. Despite the simplified geometry model and uncertainties of the severe accident source, the preliminary calculations yield impressive agreement with the measured data. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-F-J-104: Weekly MRI for Dose Assessment of Organs at Risk During Treatment of HN Cancer of the Oropharynx

Purpose: Investigate the feasibility of using weekly MRI to assess dose to organs at risk utilizing deformable image registration. Methods: Sixteen H&N patients with oropharyngeal cancer were imaged on a 3T MR scanner using T2W and mDIXON sequence. Patients were imaged on a weekly basis in treatment position. Parotids (LP & RP), submandibular glands (LS, RS), and oral cavity (OC) were delineated on the weekly MR and reviewed by a board certified radiation oncologist. The original planning CT (pCT), RT-Dose, and RT-Structures were deformed and registered to each weekly MRIs. The deformed CTs and RT-Structures were imported to the treatment planning system (TPS) and rigidly registered to the pCT. Forward dose calculation of the original RT-Plan was used to estimate the delivered dose on the deformed CT. The dose volume histograms (DVH) statistics were performed to compare planned dose, deformed dose, and forward calculated dose. In addition, Dice similarity metric (DSM) was used to compare deformed and reference structures. Results: The average (min,max) DSM between deformed and reference structures was 0.71 (0.69,0.93); 0.70 (0.64,0.89); 0.65 (0.48,0.86); 0.63 (0.37,0.89); and 0.63 (0.58,0.87); for LP, RP, LS, RS, and OC respectively. The respective average relative structures volumes changed at a weekly rate of −4.99%; −4.40%; +3.45%; +1.46%; −1.39%, respectively. The percentage difference %(min,max) between estimated delivered dose and planned dose was +3.94 (−51.3,+30.5); +6.33 (−58.6,+82.7); +2.46 (−38.9,+37.6,); +2.38(−49.0,+28.9); +3.55(−17.0,+43.1). Conclusion: The recalculated dose based on weekly MRI deviated from planned dose for all OARs. Meanwhile, the deformed dose did not reflect the subtle changes in OARs as compared to the recalculated dose. This study demonstrates the feasibility of using weekly MRI to monitor volumetric changes which has important implications on actual delivered dose.

60 APPLIED LIFE SCIENCES↗

Radiological environmental dose assessment methods and compliance dose results for 2015 operations at the Savannah River Site

This report presents the environmental dose assessment methods and the estimated potential doses to the offsite public from 2015 Savannah River Site (SRS) atmospheric and liquid radioactive releases. Also documented are potential doses from special-case exposure scenarios - such as the consumption of deer meat, fish, and goat milk.

61 RADIATION PROTECTION AND DOSIMETRY↗

When Is the Simple Radiotoxicity Approach Useful for Advanced Fuel Cycle System Assessments Given the Existence of Complex Performance Dose Assessments?

Engineers often face the general question of which approximations are appropriate for a given analytical task. In particular, when is a simpler model useful if a more complex model also exists? This paper explores this question in the domain of radiotoxicity relative to geologic disposal performance dose assessments. Criterion 1 requires that the simpler approach, radiotoxicity, must be calculated correctly. The concept of ingestion radiotoxic inventories is analogous to the inventory of toxic chemicals in other industries. From a decision analysis perspective, it is also somewhat analogous to the nuclear reactor safety concept of “passive safety.” This paper explains some of the issues in calculating radiotoxicity, motivated by the author’s observations of errors in the literature: not accounting for radioactive progeny, misunderstanding natural “ore,” and focusing on transuranic (TRU) isotopes without adequate attention to actinide decay products. For example, Th/233U fuel cycles do have lower amounts of TRU isotopes than U/239Pu fuel cycles, but that does not necessarily mean lower long-term hazard. Criterion 2 requires that the uncertainties in the more complex approach, performance dose assessments, must raise issues for the assessments’ intended purposes—in which case, radiotoxic inventory may be of assistance until those issues are resolved. Performance dose assessments were developed for, and are legally the way to show, compliance with regulations, but the uncertainties are large. Less obvious is the degree to which dose assessments are applicable to other purposes—comparing fuel cycle options prior to site selection and showing the safety of a fuel cycle and waste management approach to the public. In the last sense especially, performance dose assessments are analogous to probabilistic risk assessments for nuclear reactor safety. The United States lacks a selected consensus site, selected fuel cycle approach (direct disposal versus recycling), and selected waste form. Thus, the paper does not intend to discuss all the issues with performance dose assessments but rather intends to focus on only those performance dose uncertainties that raise issues when comparing fuel cycles. Uncertainties associated with whether a generic geological environment is attractive or a specific location meets requirements are beyond the scope of this paper. Ingestion radiotoxicity correlates with heat, gamma, and inhalation radiotoxicity. Thus, options that are relatively high in ingestion radiotoxicity tend to be high in other parameters. Therefore, reduction in ingestion radiotoxicity means both that the potential source term for release is lower but also that one driving force for release (heat) is also lower. However, the most important time frames differ as heat is mainly an issue in decades and centuries after reactor discharge, but ingestion radiotoxicity is mainly an issue during longer time periods. Ingestion radiotoxicity points to the importance of actinides in long-term waste management, followed by specific fission products such as 99Tc, 129I, 93Zr, 135Cs, and 79Se.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

EMP Attachment 3 Dose Assessment Guidance

This Dose Assessment Guidance (DAG) describes methods used to comply with the reporting requirements for individual receptor and collective dose for radionuclide air emissions under the U.S. Department of Energy, Office of Science, Pacific Northwest National Laboratory (PNNL) Environmental Monitoring Plan (EMP). The National Emission Standards for Hazardous Air Pollutants (40 CFR 61), Subpart H, is the greatest driver for the requirements. This DAG applies to public dose from radioactive material releases to the air from PNNL Richland Campus and Marine Sciences Laboratory (Sequim, Washington). The application of Richland Campus ambient external dose results is also briefly discussed. The methods used to perform the biota dose assessment reported in the Site Environmental Report are discussed. This guidance is Attachment 3 to PNNL’s EMP (PNNL-20919) and addresses a discrete, vital subject area of the EMP that is subject to revision independent of the main text of the EMP document.

40 CFR 61 Subpart H↗

EMP, Attachment 3: Dose Assessment Guidance

This Dose Assessment Guidance (DAG) describes methods used to comply with the reporting requirements for dose to an individual member of the public receptor, collective dose, and biota dose for radionuclide air emissions under the U.S. Department of Energy, Office of Science, Pacific Northwest National Laboratory (PNNL) Environmental Monitoring Plan (EMP). The National Emission Standards for Hazardous Air Pollutants (40 CFR 61), Subpart H, is the greatest driver for the requirements. This DAG applies to public dose from radioactive material releases to the air from PNNL Richland Campus and PNNL Sequim Campus. Dose determinations from Richland Campus surveillance of ambient external dose and ambient air particulates is also briefly discussed. This guidance is Attachment 3 to PNNL’s EMP (PNNL-20919) and addresses a discrete, vital subject area of the EMP that is subject to revision independent of the main text of the EMP document.

40 CFR 61 Subpart H↗

EMP Attachment 3: DOE-SC PNNL Site Dose Assessment Guidance

This Dose Assessment Guidance (DAG) describes methods to use to determine the maximally exposed individual (MEI) location and estimate dose impact to that individual under the U.S. Department of Energy (DOE) Office of Science (DOE-SC) Pacific Northwest National Laboratory (PNNL) Site Environmental Monitoring Plan (EMP). This guidance applies to public dose from radioactive material releases to the air from DOC-SC PNNL Site operations. This guidance is an attachment to PNNL’s EMP (PNNL-20919) and addresses a discrete, vital subject area of the EMP that is subject to revision independent of the main text of the EMP document.

54 ENVIRONMENTAL SCIENCES↗

EMP Attachment 3: Dose Assessment Guidance (Rev.3)

This Dose Assessment Guidance (DAG) describes methods used to comply with the reporting requirements for dose to an individual member of the public receptor, collective dose, and biota dose for radionuclide air emissions under the U.S. Department of Energy, Office of Science, Pacific Northwest National Laboratory (PNNL) Environmental Monitoring Plan (EMP). The National Emission Standards for Hazardous Air Pollutants (40 CFR 61), Subpart H, is the greatest driver for the requirements. This DAG applies to public dose from radioactive material releases to the air from PNNL-Richland Campus and PNNL Marine and Coastal Research Laboratory. Dose determinations from Richland Campus surveillance of ambient external dose and ambient air particulates is also briefly discussed. This guidance is Attachment 3 to PNNL’s EMP (PNNL-20919) and addresses a discrete, vital subject area of the EMP that is subject to revision independent of the main text of the EMP document.

40 CFR 61 Subpart H↗

EMP, Attachment 3: Dose Assessment Guidance (Rev.4)

This Dose Assessment Guidance (DAG) describes methods used to comply with the reporting requirements for dose to an individual member of the public receptor, collective dose, and biota dose for radionuclide air emissions under the U.S. Department of Energy, Office of Science, Pacific Northwest National Laboratory (PNNL) Environmental Monitoring Plan (EMP). The National Emission Standards for Hazardous Air Pollutants (40 CFR 61), Subpart H, is the greatest driver for the requirements. This DAG applies to public dose from radioactive material releases to the air from PNNL-Richland campus and PNNL-Sequim campus. Dose determinations from Richland campus surveillance of ambient external dose and ambient air particulates is also discussed. This guidance is Attachment 3 to PNNL’s EMP (PNNL-20919) and addresses a discrete, vital subject area of the EMP that is subject to revision independent of the main text of the EMP document.

40 CFR 61 Subpart H↗

Post-Remediation Radiological Dose Assessment, Painesville Site, Painesville, Ohio

A post-remediation radiological dose assessment was conducted for the Formerly Utilized Sites Remedial Action Program (FUSRAP) Painesville Site by using the measured residual concentrations of the radionuclides of concern following the completion of remedial action. The site’s FUSRAP-related constituents of concern (COCs) are radionuclides associated with past activities conducted by the Manhattan Engineer District (MED) and Atomic Energy Commission (AEC) in support of the Nation’s early atomic energy and weapons program, and include radium-226 (Ra-226), thorium-230 (Th-230), thorium-232 (Th-232), and total uranium (Total U). Remedial actions were conducted at the site in accordance with the Final Record of Decision for the Painesville Site, Painesville, Ohio (ROD) (USACE 2006). In the ROD, the U.S. Army Corps of Engineers (USACE) determined that the U.S. Nuclear Regulatory Commission (NRC) standards for decommissioning of licensed facilities found in Title 10, Part 20.1402 of the Code of Federal Regulations (10 CFR 20.1402) and in the Ohio Administrative Code (OAC) 3701:1-38-22(B) are applicable or relevant and appropriate requirements (ARARs) for the site. On the basis of the ARAR analysis, a total effective dose equivalent (TEDE) goal of 25 millirem per year (mrem/yr) was assumed for the site with a construction worker considered as the average member of the critical group. Derived concentration guideline levels (DCGLs) for residual radioactivity of the COCs in soil were developed for the Painesville Site using the RESRAD (Version 6.22) computer code (Yu et al. 2001), which was designed to estimate radiation doses and risks from RESidual RADioactive materials. The DCGLs represent activity levels above site average background activity corresponding to the 25-mrem/yr criterion for a construction worker scenario. The DCGLs are above the background activity concentrations and represent average concentration guidelines. The DCGLs and average background activity concentrations are provided in Table 1. The Final Feasibility Study Addendum (USACE 2005) provides a complete description of the derivation of the DCGLs for the Painesville Site. A post-remediation radiological dose assessment was performed to determine the potential radiation doses to a construction worker, consistent with the approach used to develop the DCGLs for the Painesville Site given in the Final Feasibility Study Addendum (USACE 2005) and ROD (USACE 2006). A second more conservative dose assessment was performed to determine the potential radiation doses to an urban resident who is assumed to live and garden on the site. To further evaluate the long-term protectiveness of the remedial action, a third dose assessment was conducted to determine the potential radiation doses to a hypothetical subsistence farmer. The primary difference between exposure to an urban resident versus a conservative subsistence farmer would be an increase in the amount of foodstuffs (homegrown produce, milk, and beef) produced/cultivated and consumed on-site.

54 ENVIRONMENTAL SCIENCES↗

US EPA Superfund Radiation Risk Assessment Update: Superfund Update: Revisions to Risk and Dose Assessment Tools - 19057

The U.S. Environmental Protection Agency (EPA) Superfund remedial program is finishing up a significant number of revisions to its guidance for the risk assessment process at radioactively contaminated Superfund sites. The six Preliminary Remediation Goal (PRG) and Dose Compliance Concentration (DCC) internet-based calculators for radiation risk and dose assessment at Superfund sites are being revised to reflect better science, revisions to existing exposure scenarios and new scenarios, and changes to match up more closely with the EPA chemical Regional Screening Level calculator. A comprehensive set of revisions to the PRG calculator was finished in November 2014. Additional revisions to the other 5 calculators were made in 2015. A set of further revisions are expected to be finalized prior to December 2018 and will be discussed in this abstract. A new Radon Vapor Intrusion Screening Level (RVISL) calculator is expected to be finished in 2019, similar to the Vapor Intrusion Screening Level (VISL) for chemical calculator that was finished in 2018. There are several additional revisions that may be finished prior to WM 2019 and will be presented if finished or discussed in more general terms if still underway. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a New Chelation Model: Bioassay Data Interpretation and Dose Assessment after Plutonium Intake via Wound and Treatment with DTPA

The administration of chelation therapy to treat significant intakes of actinides, such as plutonium, affects the actinide’s normal biokinetics. In particular, it enhances the actinide’s rate of excretion, such that the standard biokinetic models cannot be applied directly to the chelation-affected bioassay data in order to estimate the intake and assess the radiation dose. Here we propose a new chelation model that can be applied to the chelation-affected bioassay data after plutonium intake via wound and treatment with DTPA. In the proposed model, chelation is assumed to occur in the blood, liver, and parts of the skeleton. Ten datasets, consisting of measurements of 14 C-DTPA, 238 Pu, and 239 Pu involving humans given radiolabeled DTPA and humans occupationally exposed to plutonium via wound and treated with chelation therapy, were used for model development. The combined dataset consisted of daily and cumulative excretion (urine and feces), wound counts, measurements of excised tissue, blood, and post-mortem tissue analyses of liver and skeleton. The combined data were simultaneously fit using the chelation model linked with a plutonium systemic model, which was linked to an ad hoc wound model. The proposed chelation model was used for dose assessment of the wound cases used in this study.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 06: Dose assessment of cone beam CT imaging protocols as part of SPECT/CT examinations

Purpose: To assess radiation dose from the cone beam CT (CBCT) component of SPECT/CT studies and to compare with other CT examinations performed in our institution. Methods: We used an anthropomorphic chest phantom and the 6 cc ion chamber to measure entrance breast dose for several CBCT and diagnostic CT acquisition protocols. The CBCT effective dose was calculated with ImPACT software; the CT effective dose was evaluated from the DLP value and conversion factor, dependent on the anatomic region. The RADAR medical procedure radiation dose calculator was used to assess the nuclear medicine component of exam dose. Results: The entrance dose to the breast measured with the anthropomorphic phantom was 0.48 mGy and 9.41 mGy for cardiac and chest CBCT scans; and 4.59 mGy for diagnostic thoracic CT. The effective doses were 0.2 mSv, 3.2 mSv and 2.8 mSv respectively. For a small patient represented by the anthropomorphic phantom, the dose from the diagnostic CT was lower than from the CBCT scan, as a result of the exposure reduction options available on modern CT scanners. The CBCT protocols used the same fixed scanning techniques. The diagnostic CT dose based on the patient data was 35% higher than the phantom dose. For most SPECT/CT studies the dose from the CBCT component was comparable with the dose from the radiopharmaceutical. Conclusions: The patient radiation dose from the cone beam CT scan can be higher than that from a diagnostic CT and should be taken into consideration in evaluating total SPECT/CT patient dose.

60 APPLIED LIFE SCIENCES↗

US EPA Superfund Radiation Risk Assessment Update: Superfund Update: Revisions to Risk and Dose Assessment Tools - 18232

The U.S. Environmental Protection Agency (EPA) Superfund remedial program is finishing up a significant number of revisions to its guidance for the risk assessment process at radioactively contaminated Superfund sites. The six Preliminary Remediation Goal (PRG) and Dose Compliance Concentration (DCC) internet based calculators for risk and dose assessment at Superfund sites are being revised to reflect better science, revisions to existing exposure scenarios and new scenarios, and changes to match up more closely with the EPA chemical regional screening level calculator. A comprehensive set of revisions to the PRG calculator was finished in November 2014. Additional revisions to the other 5 calculators were made in 2015. A set of further revisions are expected to be finalized prior to December 2016 and will be discussed in this abstract. There are several additional revisions that may be finished prior to WM 2017 and will be presented if finished or discussed in more general terms if still underway. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Peak Dose Assessment for Proposed DOE-PPPO Authorized Limits

The Oak Ridge Institute for Science and Education (ORISE), a U.S. Department of Energy (DOE) prime contractor, was contracted by the DOE Portsmouth/Paducah Project Office (DOE-PPPO) to conduct a peak dose assessment in support of the Authorized Limits Request for Solid Waste Disposal at Landfill C-746-U at the Paducah Gaseous Diffusion Plant (DOE-PPPO 2011a). The peak doses were calculated based on the DOE-PPPO Proposed Single Radionuclides Soil Guidelines and the DOE-PPPO Proposed Authorized Limits (AL) Volumetric Concentrations available in DOE-PPPO 2011a. This work is provided as an appendix to the Dose Modeling Evaluations and Technical Support Document for the Authorized Limits Request for the C-746-U Landfill at the Paducah Gaseous Diffusion Plant, Paducah, Kentucky (ORISE 2012). The receptors evaluated in ORISE 2012 were selected by the DOE-PPPO for the additional peak dose evaluations. These receptors included a Landfill Worker, Trespasser, Resident Farmer (onsite), Resident Gardener, Recreational User, Outdoor Worker and an Offsite Resident Farmer. The RESRAD (Version 6.5) and RESRAD-OFFSITE (Version 2.5) computer codes were used for the peak dose assessments. Deterministic peak dose assessments were performed for all the receptors and a probabilistic dose assessment was performed only for the Offsite Resident Farmer at the request of the DOE-PPPO. In a deterministic analysis, a single input value results in a single output value. In other words, a deterministic analysis uses single parameter values for every variable in the code. By contrast, a probabilistic approach assigns parameter ranges to certain variables, and the code randomly selects the values for each variable from the parameter range each time it calculates the dose (NRC 2006). The receptor scenarios, computer codes and parameter input files were previously used in ORISE 2012. A few modifications were made to the parameter input files as appropriate for this effort. Some of these changes included increasing the time horizon beyond 1,050 years (yr), and using the radionuclide concentrations provided by the DOE-PPPO as inputs into the codes. The deterministic peak doses were evaluated within time horizons of 70 yr (for the Landfill Worker and Trespasser), 1,050 yr, 10,000 yr and 100,000 yr (for the Resident Farmer [onsite], Resident Gardener, Recreational User, Outdoor Worker and Offsite Resident Farmer) at the request of the DOE-PPPO. The time horizons of 10,000 yr and 100,000 yr were used at the request of the DOE-PPPO for informational purposes only. The probabilistic peak of the mean dose assessment was performed for the Offsite Resident Farmer using Technetium-99 (Tc-99) and a time horizon of 1,050 yr. The results of the deterministic analyses indicate that among all receptors and time horizons evaluated, the highest projected dose, 2,700 mrem/yr, occurred for the Resident Farmer (onsite) at 12,773 yr. The exposure pathways contributing to the peak dose are ingestion of plants, external gamma, and ingestion of milk, meat and soil. However, this receptor is considered an implausible receptor. The only receptors considered plausible are the Landfill Worker, Recreational User, Outdoor Worker and the Offsite Resident Farmer. The maximum projected dose among the plausible receptors is 220 mrem/yr for the Outdoor Worker and it occurs at 19,045 yr. The exposure pathways contributing to the dose for this receptor are external gamma and soil ingestion. The results of the probabilistic peak of the mean dose analysis for the Offsite Resident Farmer indicate that the average (arithmetic mean) of the peak of the mean doses for this receptor is 0.98 mrem/yr and it occurs at 1,050 yr. This dose corresponds to Tc-99 within the time horizon of 1,050 yr.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evolving Adjustments to External (Gamma) Slope Factors for CERCLA Risk and Dose Assessments - 12290

To model the external exposure pathway in risk and dose assessments of radioactive contamination at Superfund sites, the U.S. Environmental Protection Agency (EPA) uses slope factors (SFs), also known as risk coefficients, and dose conversion factors (DCFs). Without any adjustment these external radiation exposure pathways effectively assumes that an individual is exposed to a source geometry that is effectively an infinite slab. The concept of an 'infinite slab' means that the thickness of the contaminated zone and its aerial extent are so large that it behaves as if it were infinite in its physical dimensions. EPA has been making increasingly complex adjustments to account for the extent of the contamination and its corresponding radiation field to provide more accurate risk and dose assessment modeling when using its calculators. In most instances, the more accurate modeling results derived from these gamma adjustments are less conservative. The notable exception are for some radionuclides in rooms with contaminated walls, ceiling, and floors, and the receptor is in location of the room with the highest amount of radiation exposure, usually the corner of small rooms and the center of large conference rooms. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dosimetry concepts for scanner quality assurance and tissue dose assessment in micro-CT

Purpose: At present, no established methods exist for dosimetry in micro computed tomography (micro-CT). The purpose of this study was therefore to investigate practical concepts for both dosimetric scanner quality assurance and tissue dose assessment for micro-CT. Methods: The computed tomography dose index (CTDI) was adapted to micro-CT and measurements of the CTDI both free in air and in the center of cylindrical polymethyl methacrylate (PMMA) phantoms of 20 and 32 mm diameter were performed in a 6 month interval with a 100 mm pencil ionization chamber calibrated for low tube voltages. For tissue dose assessment, z-profile measurements using thermoluminescence dosimeters (TLDs) were performed and both profile and CTDI measurements were compared to Monte Carlo (MC) dose calculations to validate an existing MC tool for use in micro-CT. The consistency of MC calculations and TLD measurements was further investigated in two mice cadavers. Results: CTDI was found to be a reproducible quantity for constancy tests on the micro-CT system under study, showing a linear dependence on tube voltage and being by definition proportional to mAs setting and z-collimation. The CTDI measured free in air showed larger systematic deviations after the 6 month interval compared to the CTDI measured in PMMA phantoms. MC calculations were found to match CTDI measurements within 3% when using x-ray spectra measured at our micro-CT installation and better than 10% when using x-ray spectra calculated from semi-empirical models. Visual inspection revealed good agreement for all z-profiles. The consistency of MC calculations and TLD measurements in mice was found to be better than 10% with a mean deviation of 4.5%. Conclusions: Our results show the CTDI implemented for micro-CT to be a promising candidate for dosimetric quality assurance measurements as it linearly reflects changes in tube voltage, mAs setting, and collimation used during the scan, encouraging further studies on a variety of systems. For tissue dose assessment, MC calculations offer an accurate and fast alternative to TLD measurements allowing for dose calculations specific to any geometry and scan protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗