Search NASA⌕ Search

SEARCH · Search NASA

Results for “dosimetry modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A mixture parameterized biologically based dosimetry model to predict body burdens of polycyclic aromatic hydrocarbons in developmental zebrafish toxicity assays

Polycyclic aromatic hydrocarbons (PAHs) are a group of environmental toxicants found ubiquitously as complex mixtures in human-impacted environments. Developmental zebrafish exposures have been used widely to study PAH toxicity, but most studies report nominal exposure concentrations. Nominal exposure concentrations can be unreliable dose metrics due to differences in toxicant bioavailability resulting from disparate exposure methodologies and chemical properties. Toxicokinetic modeling can predict toxicant tissue doses to facilitate comparison between exposures of different chemicals, methodologies, and biological models. We parameterize a biologically based dosimetry model for developmental zebrafish toxicity assays for 9 PAHs. The model was optimized with measurements from media, tissue, and plastic plate walls throughout a static developmental exposure to a mixture of 10 PAHs of high abundance within the Portland Harbor Superfund Site. Plate binding, volatilization, zebrafish permeability, and tissue—media partitioning coefficients vary widely between PAHs. Model predictions accounted for 83% and 54% of 48 hpf body burdens within a factor of 2 resulting from exposures to mixtures and individual PAHs, respectively. Accounting for solubility significantly improves model performance. Competition for active sites in metabolizing enzymes may change biotransformation kinetics between individual PAH and mixture exposures. Area under the curve estimations of concentrations in zebrafish resulted in altered hazard rankings from nominal exposure concentrations. Future work will be oriented to generalizing the model to other PAHs. This PAH dosimetry model improves the interpretability of developmental zebrafish toxicity assays by providing time-resolved body burdens from nominal exposure concentrations.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Godiva IV Thermal Neutron Dosimetry Modeling and Variance Reduction

The transfer of the Godiva IV experiment from the Los Alamos Critical Experiments Facility (LACEF) to the National Critical Experiments Research Center (NCERC) introduced a vastly different experiment room return to the neutron flux. The contribution of the background to the burst neutron energy spectrum is significant in the thermal and epithermal neutron energies. Target materials may be placed in various locations in the Godiva room, or outside of the room, for thermal neutron activation. Modeling of this dosimetry problem in Monte Carlo N-Particle (MCNP) presented a novel challenge compared to previous Godiva IV glory hole irradiation simulations. An advanced dosimetry modeling framework for high efficiency calculations in locations far from the Godiva IV fission source was desired. The mesh-based weight windows and point detector advanced variance reduction techniques in MCNP were implemented and tested using adaptations of the critical experiment benchmark model of the Godiva IV problem. The models were validated against measured activations of Nickel, Indium, Scandium, and Cobalt foils at locations 2 meters from the Godiva IV core. Dosimetry measurements were performed in collaboration with Sandia National Laboratory. The weight windows and point detector variance reduction coupled method resulted in the highest problem efficiency.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Stochastic parametric skeletal dosimetry model for humans: General approach and application to active marrow exposure from bone-seeking beta-particle emitters

The objective of this study is to develop a skeleton model for assessing active marrow dose from bone-seeking beta-emitting radionuclides. This article explains the modeling methodology which accounts for individual variability of the macro- and microstructure of bone tissue. Bone sites with active hematopoiesis are assessed by dividing them into small segments described by simple geometric shapes. Spongiosa, which fills the segments, is modeled as an isotropic three-dimensional grid (framework) of rod-like trabeculae that “run through” the bone marrow. Randomized multiple framework deformations are simulated by changing the positions of the grid nodes and the thickness of the rods. Model grid parameters are selected in accordance with the parameters of spongiosa microstructures taken from the published papers. Stochastic modeling of radiation transport in heterogeneous media simulating the distribution of bone tissue and marrow in each of the segments is performed by Monte Carlo methods. Model output for the human femur at different ages is provided as an example. The uncertainty of dosimetric characteristics associated with individual variability of bone structure was evaluated. An advantage of this methodology for the calculation of doses absorbed in the marrow from bone-seeking radionuclides is that it does not require additional studies of autopsy material. The biokinetic model results will be used in the future to calculate individual doses to members of a cohort exposed to 89,90 Sr from liquid radioactive waste discharged to the Techa River by the Mayak Production Association in 1949–1956. Further study of these unique cohorts provides an opportunity to gain more in-depth knowledge about the effects of chronic radiation on the hematopoietic system. In addition, the proposed model can be used to assess the doses to active marrow under any other scenarios of 90 Sr and 89 Sr intake to humans.

59 BASIC BIOLOGICAL SCIENCES↗

Stochastic parametric skeletal dosimetry model for humans: Pediatric and adult computational skeleton phantoms for internal bone marrow dosimetry

Currently, computational phantoms that simulate skeletal tissues are used in active red bone marrow (AM) internal dosimetry. Up-to-date reference computational phantoms recommended by the ICRP are based on the analysis of CT-images of cadavers. Such phantoms have significant disadvantages. One disadvantage is that the assessment of uncertainty due to the population variability of skeleton dimensions and microstructure results from the limited availability of autopsy material. Another disadvantage is the simplified modelling of cortical layer and bone microarchitecture. A method of stochastic parametric skeletal dosimetry modelling of the bone structures – SPSD modelling – has been developed as an alternative to the ICRP reference phantoms. In the framework of this approach, skeletal phantom parameters are evaluated based on extensively reviewed results of published measurements of real bones. The SPSD approach allows for the assessment of both population-average values and their variability. SPSD-phantoms of the skeleton are modelled in voxel representation. They consist of smaller phantoms of the bone sites – segments – described by simple geometric shapes with uniform microarchitecture parameters. Such segmentation makes it possible to account for non-homogeneous skeletal microarchitecture and to model the bone structure with the required voxel resolution to elaborate suitable skeletal phantoms. The current study presents the parameters of the SPSD skeletal phantoms for the following age-groups: newborn, 1-year-old, 5-year-old, 10-year-old, 15-year-old (male and female), and adult (male and female). This skeletal phantom can be used for dosimetry as an alternative to available reference phantoms for bone-seeking radionuclides. The above-mentioned age- and sex-specific skeletal phantoms are comprised of 289 unique segments. The characteristics of the SPSD phantoms do not contradict published data and are in good agreement with the measurement results of real bones.

Science & Technology - Other Topics↗

Stochastic parametric skeletal dosimetry model for humans: Anatomical-morphological basis and parameter evaluation

Radiation exposure of the hematopoietic system that results in a radiation dose to bone marrow of more than 100 mGy leads to an increase in the risk of leukemia in humans. Excess relative risk of leukemia was observed in cohorts whose members lived in the territories of the Southern Urals that were radioactively contaminated in the 1950s. As part of the dosimetric support of epidemiological studies of these cohorts, an original methodology for stochastic bone dosimetric modeling was developed, termed the Stochastic Parametric Skeletal Dosimetry (SPSD) model. The purpose of this work was to present the anatomical and morphological bases of the SPSD model, which includes an assessment of the parameters of the microstructure of the trabecular bone in the hematopoietic areas of the human skeleton, as well as a description of the macrostructural division (segmentation) of hematopoietic areas into simple bone segments. As a result, an anatomical-morphological basis of the SPSD model was created based on published data. Data collection work included the analysis of original articles, atlases, manuals, monographs and the formation of primary data files. Data on the duration of hematopoiesis in various parts of the skeleton; and data on age-related changes in the microstructure and linear dimensions of human bones and their segments were analyzed. The paper describes the full set of parameters to be used for the dosimetric model for newborns, children aged 1, 5 and 10 years, as well as for adolescents aged 15 years and adults; for the latter, sex differences in bone size were considered. In total, the SPSD model includes 289 unique basic (bone) phantom segments, each of which is described by 7 or more parameters describing the microstructure, thickness of the cortical layer and linear dimensions. Population variability was estimated for each parameter. The approach to SPSD modeling, i.e., the use of simple geometric shapes, was successfully verified using independent datasets on bone masses and volumes.

Science & Technology - Other Topics↗

New Approach Methodology for Assessing Inhalation Risks of a Contact Respiratory Cytotoxicant: Computational Fluid Dynamics-Based Aerosol Dosimetry Modeling for Cross-Species and In Vitro Comparisons

Regulatory agencies are considering alternative approaches to assessing inhalation toxicity that utilizes in vitro studies with human cells and in silico modeling in lieu of additional animal studies. In support of this goal, computational fluid-particle dynamics models were developed to estimate site-specific deposition of inhaled aerosols containing the fungicide, chlorothalonil, in the rat and human for comparisons to prior rat inhalation studies and new human in vitro studies. Under bioassay conditions, the deposition was predicted to be greatest at the front of the rat nose followed by the anterior transitional epithelium and larynx corresponding to regions most sensitive to local contact irritation and cytotoxicity. For humans, simulations of aerosol deposition covering potential occupational or residential exposures (1–50 µm diameter) were conducted using nasal and oral breathing. Aerosols in the 1–5 µm range readily penetrated the deep region of the human lung following both oral and nasal breathing. Under actual use conditions (aerosol formulations >10 µm), the majority of deposited doses were in the upper conducting airways. Beyond the nose or mouth, the greatest deposition in the pharynx, larynx, trachea, and bronchi was predicted for aerosols in the 10–20 µm size range. Only small amounts of aerosols >20 µm penetrated past the pharyngeal region. Using the ICRP clearance model, local retained tissue dose metrics including maximal concentrations and areas under the curve were calculated for each airway region following repeated occupational exposures. These results are directly comparable with benchmark doses from in vitro toxicity studies in human cells leading to estimated human equivalent concentrations that reduce the reliance on animals for risk assessments.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Efficient bi-directional coupling of 3D computational fluid-particle dynamics and 1D Multiple Path Particle Dosimetry lung models for multiscale modeling of aerosol dosimetry

The development of predictive aerosol dosimetry models has been a major focus of environmental toxicology and pharmaceutical health research for decades. One-dimensional (1D) models successfully predict overall deposition averages but fail to accurately predict local deposition. Computational fluid-particle dynamics (CFPD) models provide site-specific predictions but at a computational cost that prohibits whole lung predictions. Thus, there is a need for developing multiscale strategies to provide a realistic subject-specific picture of the fate of inhaled aerosol in the lungs. CT-based 3D/CFPD models of the large airways were bidirectionally coupled with individualized 1D Navier-Stokes airflow and particle transport based upon the widely used Multiple Path Particle Dosimetry Model (MPPD). Distribution of airflows among lobes was adjusted by measured lobar volume changes observed in CT images between FRC and FRC + 1.5 L. Additionally, as a test of the effectiveness of the coupling procedures, deposition modeling of previous 1 µm aerosol exposure studies was performed. The complete coupled model was run for 3 breaths, with the computation-intense portion being the 3D CFD Lagrangian particle tracking calculation. The average deposition per breath was 11% in the combined multiscale model with site-specific doses available in the CFPD portion of the model and airway- or region-specific deposition available for the MPPD portion. In conclusion, the key methods developed in this study enable predictions of ventilation heterogeneities and aerosol deposition across the lungs that are not captured by 3D or 1D models alone. Overall, these methods can be used as the foundation for multi-scale modeling of the full respiratory system.

60 APPLIED LIFE SCIENCES↗

Human in vitro metabolism of an environmental mixture of polycyclic aromatic hydrocarbons (PAH) found at the Portland Harbor Superfund Site

Polycyclic aromatic hydrocarbons (PAHs) are widespread environmental contaminants that pose health risks to humans. Toxicity testing approaches of PAHs have evolved from traditional rodent models to New Approach Methodologies (NAMs), such as high-throughput screening in zebrafish, enabling rapid evaluation of chemical hazards. However, translating toxicity findings from laboratory systems to humans remains difficult due to complexity and species-specific differences. Chemical dosimetry modeling offers a quantitative framework to bridge this gap, but its accuracy depends on robust knowledge of PAH metabolism. The objective of this study was to measure human metabolism rates of Supermix-10, the ten most abundant PAHs found at the Portland Harbor Superfund Site, to support development of human pharmacokinetic models. We incubated individual PAHs from Supermix-10 in pooled human liver microsomes and quantified parent PAH disappearance using high-performance liquid chromatography (HPLC) with UV and florescent detection. To assess the potential of mixture interactions, we also measured metabolism of all 10 compounds in an equimolar mixture and compared rates of parent disappearance to those observed for individual PAHs. All Supermix-10 PAHs demonstrated rapid parent compound disappearance in human hepatic microsomes. PAHs grouped into three metabolism patterns: high metabolism rates and capacity (2-methylnaphthalene, acenaphthylene, fluorene, naphthalene), high affinity metabolism that rapidly achieves low-level saturation (benzo[a]anthracene, chrysene), and moderate metabolism rates and capacity (fluoranthene, pyrene, retene, phenanthrene). Smaller PAHs exhibited faster metabolism, and higher metabolism rates correlated inversely with molecular weight. When incubated in an equimolar mixture, Supermix-10 demonstrated significantly slower metabolism (47–89 %) compared to metabolism of individual PAHs at the same concentration. These findings enhance our understanding of PAH metabolism in humans and demonstrate significant mixture interactions under the conditions tested. Furthermore, our findings offer insights into the metabolic behavior of Supermix-10 and provide critical metabolism rate data to support the development of physiological based pharmacokinetic (PBPK) models. Dosimetry models can translate PAH chemical dosimetry from high-throughput testing platforms, like zebrafish and cellular system assays, to human exposures enhancing the accuracy and reliability of PAH risk assessments.

2-methylnaphthalene↗

A Review of the Resuspension of Radioactively Contaminated Particles by Vehicle and Pedestrian Traffic—Current Theory, Practice, Gaps, and Needs

Here, the resuspension of radioactively contaminated particles in a built environment, such as from urban surfaces like foliage, building exteriors, and roadways, is described empirically by current plume and dosimetry models used for hazard assessment and long-term risk purposes. When applying these models to radiological contamination emergencies affecting urban areas, the accuracy of the results for recent contamination deposition is impacted in two main ways. First, the data supporting the underlying resuspension equations was acquired for open, quiescent conditions with no vehicle traffic or human activities, so it is not necessarily representative of the urban environment. Second, mechanical disturbance by winds in urban canyons and during emergency operations caused by vehicle traffic and human activities are not directly considered by the equations. Accordingly, plume and dosimetry models allow the user to input certain compensating values, but the models do not necessarily supply users instructions on what values to use. This manuscript reviews the available literature to comprehensively and consistently pool data for resuspension due to mechanically induced resuspension applicable to urban contamination. Because there are few studies that directly measured radioactive resuspension due to vehicles and pedestrians, this review novelly draws on a range of other studies involving non-radioactive particles, ranging from outdoor air pollution emissions to indoor allergen transport. The results lead to tabulated, recommended values for specific conditions in the emergency phase to help users of plume and dosimetry models maintain the conservativeness needed to properly capture the potential radiation dose posed by mechanically induced resuspension. These values are of benefit to model users until better data are available. The results also suggest the types of data that may result in improved plume and dose modeling.

61 RADIATION PROTECTION AND DOSIMETRY↗

Influence of alveolar mixing and multiple breaths of aerosol intake on particle deposition in the human lungs

Predictive dosimetry models play an important role in assessing health effect of inhaled particulate matter and in optimizing delivery of inhaled pharmaceutical aerosols. Here, in this study, the commonly used 1D Multiple-Path Particle Dosimetry model (MPPD) was improved by including a mechanistically based model component for alveolar mixing of particles and by extending the model capabilities to account for multiple breaths of aerosol intake. These modifications increased the retained fraction of particles and consequently particle deposition predictions in the deep lung during tidal breathing. Comparison with an existing dataset (J. Aerosol Sci., 99:27-39, 2016) obtained under two breathing conditions referred to as slow and fast breathing showed significant differences in 1 µm particle deposition between predictions (slow: 30±1%, fast: 21±1%) and measurements (slow: 43±9%, fast: 30±5%) when the prior version of MPPD (single breath and no mixing, J. Aerosol Sci., 151:105647, 2021) was used. Adding a mixing model and multiple breaths moved the predictions (slow: 34±2%, fast:25±2%) closer to the range of deposition measurements. For 2.9 µm particles, predictions from both the original (slow: 70±2%, fast: 57±2%) and the revised MPPD model (slow: 71±2%, fast: 59±3%) compared well with experiments (slow: 67±8%, fast: 58±10%). This was expected as suspended fraction of 2.9 µm particles was small and thus the addition of alveolar mixing and multi breath capability only slightly increased the retained fraction for particles of this size and greater. The revised 1D model improves dose predictions in the deep lung and support human risk assessment from exposure to airborne particles.

60 APPLIED LIFE SCIENCES↗

Internal Radiation Dose Evaluation For An Unruptured Post Release Tristructural Istropic Fuel Particle for Advanced and Micro-reactor Applications

There are unique benefits from advanced/micro reactor designs and fuel types that offer safety features in the case of an accident that may reduce environmental consequences compared to conventional reactors and fuels. Several micro reactor designs, for both civilian and military applications, are proposed using tristructural-isotropic (TRISO) fuel. TRISO particles are a robust advanced nuclear fuel type that leads to the unique question of how unruptured, activated TRISO particles will interact with humans. Human exposure to nuclear fuel, or radionuclides, includes all pathways of exposure. However, TRISO particles are 0.9 mm in size, and that particle size restricts internal dose assessment to the ingestion pathway; eliminating the inhalation and dermal absorption pathways. Furthermore, activity of the TRISO particle was established by High Temperature Engineering Test Reactor simulations assuming the TRISO particle was one day post-release from the reactor. International Commission of Radiological Protection publications 100 and 133 were used to develop the internal dosimetry model for an unruptured TRISO particle for the International Commission of Radiological Protection reference male and female dose assessment. The rectosigmoid colon had the highest internal organ dose for both reference male (2.1 Sv) and reference female (2.3 Sv). The internal dose from ingestion of the scenario-defined TRISO particle was 0.25 Sv for the reference male and 0.29 Sv for the refence female, which exceeds the annual occupational effective dose limit of 0.05 Sv in the code of federal regulations, 10.CFR.20 Subpart C.

61 RADIATION PROTECTION AND DOSIMETRY↗

Secondhand Exposure to Simulated Cannabis Vaping Aerosols

Emissions from cannabis vaping degrade indoor air quality and expose non-users to secondhand pollutants. We investigated how the vaping mixture composition affects indoor aerosol characteristics and exposures. Simulated cannabis vaping aerosol was produced by flash evaporation in a 20 m3 chamber of mixtures containing terpenoids, cannabinoids, cannabis extract constituents, and the adulterant vitamin E acetate (VEA). Aerosol time- and size-resolved concentrations (8 nm-2.5 μm at 1 Hz) were measured, and a dosimetry model was used to evaluate the intake of secondhand aerosols. The results showed peak particle number (PN) concentrations between 0.7 × 106 and 13 × 106 cm-3 and peak mass concentration (PM1.0) between 65 and 1191 μg m-3 at t = 5 min after emission. Concentrations decreased to 21-57% of peak PN and 33-69% of peak PM1.0 at t = 60 min. The PM1.0 yield was 0.06 for a terpenoid-only mixture, 0.22-0.36 for tetrahydrocannabinol (THC)-terpenoid mixtures, and >1 for mixtures containing high concentrations of cannabidiol (CBD) or VEA. For intake deposition, the highest aerosol fraction was deposited in the pulmonary region, followed by the tracheobronchial and head regions. Deposition increased in the presence of THC, CBD, or VEA, with aerosols <100 nm contributing the majority of particles deposited in all regions.

Tang, Xiaochen↗

Evaluation of Dose Coefficients Implemented in MACCS

A variety of dose conversion factor files (DCF files) have been supplied for use with the MACCS code since it was initially released. For MACCS 4.2, the MACCS DCF files have been updated to include coefficients used in the computation of acute skin doses from within the MACCS software to increase functionality and to add a pseudo-organ to represent the total effective dose equivalent (TEDE) (as defined in 10 CFR 20.1003) based on International Commission on Radiological Protection (ICRP) Publication 30. This report provides a description of how these changes have been implemented and a summary of the various DCF files supplied with MACCS 4.2. The report also provides supplemental discussions to assist the reader in understanding the technical basis for the MACCS DCFs. These supplemental discussions include a summary of basic dosimetry modeling concepts and a brief review of the Federal Guidance Reports (FGRs) upon which MACCS dose coefficients have historically been based.

97 MATHEMATICS AND COMPUTING↗

Automated bidirectional coupling of multiscale models of aerosol dosimetry: Validation with subject-specific deposition data

Assessing the toxicity of airborne particulate matter or the efficacy of inhaled drug depends upon accurate estimates of deposited fraction of inhaled materials. In silico approaches can provide important insights into site- or airway-specific deposition of inhaled aerosols in the respiratory system. In this study, we improved on our recently developed 3D/1D model that simulate aerosol transport and deposition in the whole lung over multiple breath cycles. A subject-specific multiscale lung model of a healthy male subject using computational fluid-particle dynamics (CFPD) in a 3D model of the oral cavity through the large bronchial airways entering each lobe was bidirectionally coupled with a recently improved Multiple Path Particle Dosimetry (MPPD) model to predict aerosol deposition over the entire respiratory tract over multiple breaths for four conditions matching experimental aerosol exposures in the same subject from which the model was developed. These include two particle sizes (1 and 2.9 μm) and two subject-specific breathing rates of ~300 ml/s (slow breathing) and ~750 ml/s (fast breathing) at a target tidal volume of 1 L. In silico predictions of retained fraction were 0.31 and 0.29 for 1 μm and 0.66 and 0.62 for 2.9 μm during slow and fast breathing, respectively, and compared well with experimental data (1 μm: 0.31 ± 0.01 (slow) and 0.27 ± 0.01 (fast), 2.9 μm: 0.63 ± 0.03 (slow) and 0.68 ± 0.02 (fast)). Furthermore, these results provide a great deal of confidence in the validity and reliability of our approach.

60 APPLIED LIFE SCIENCES↗

A physiologically based pharmacokinetic (PBPK) model to align dosimetry of the isobutyl metabolic series in rats and humans

Here, we developed a physiologically based pharmacokinetic (PBPK) model in rats and humans for the isobutyl metabolic series including isobutyl acetate, isobutanol, isobutyraldehyde, and isobutyric acid. Chemical manufactures routinely use these compounds as solvents, for chemical synthesis, as potential biofuels, de-icing fluids, and additives for food and/or fragrance in consumer products. Human exposure to isobutyl compounds can occur through inhalation or oral routes. We previously developed a PBPK model for the propyl metabolic series and utilized it as a framework to create the isobutyl PBPK model due to the chemical similarities between the two series. To support model development, we measured in vitro metabolism of isobutyl acetate in rat and human blood and liver S9 fractions. Compared to rats, humans demonstrated faster isobutyl acetate hydrolysis in liver S9 fractions, while the hydrolysis rates in blood were similar between the two species. We used concentrations of isobutyl compounds measured in air and blood from rats exposed to isobutyl acetate and isobutanol as well as other published data to further parameterize the model. Following exposure to either isobutyl acetate or isobutanol, we observed isobutanol concentrations highest among the isobutyl compounds in the blood of rats. Overall, the model accurately predicts measured time course concentrations of isobutyl acetate, isobutanol, and isobutyric acid in available data in rats and humans. Sensitivity analyses identified alveolar ventilation rates, isobutyl metabolism rates, and cardiac output as the most sensitive parameters affecting concentrations of isobutyl compounds in blood. The isobutyl PBPK model enables comparisons of internal dose metrics across various isobutyl compound exposures and species and allows for calculation of equivalent external exposures that result in the same dose metric. Regulators can employ this PBPK model to predict and align internal dose metrics of isobutyl compounds for risk assessment purposes.

2-methyl-1-propanol↗

Building a predictive model for polycyclic aromatic hydrocarbon dosimetry in organotypically cultured human bronchial epithelial cells using benzo[ a ]pyrene

The airway epithelium is a primary route of exposure for inhaled toxicants, and organotypic culture models represent an important advancement for toxicity testing compared to simple in vitro models that may lack metabolic capability and multicellular structure/communication associated with the bronchial epithelium in vivo. A quantitative understanding of chemical dosimetry is key for interpreting and extrapolating study results; however, dosimetry is understudied in organotypic models limiting ability to predict toxicity. We developed a dosimetry model for primary human bronchial epithelial cells (HBECs) cultured at the air-liquid interface (ALI) using benzo[a]pyrene (BAP), a representative polycyclic aromatic hydrocarbon. Dose and time course evaluation of metabolite formation and enzyme activity and expression were utilized to parameterize a cellular dosimetry model to improve the utility of ALI-HBECs for assessing chemical risk. Dosimetry analysis demonstrated absorption of BAP into cells and an increase in Phase 1 and 2 metabolites over time that correlated with regulation of metabolizing enzymes. BAP was cleared from cells by 48 h after exposure, and the primary metabolites generated in ALI-HBECs were BAP-3-phenol, BAP-4,5-dihydrodiol, BAP-7,8-dihydrodiol, BAP-9,10-dihydrodiol, BAP-7,8,9,10-tetrol, BAP-3-phenol-glucuronide, BAP-4,5-dihydrodiol-glucuronide, and BAP-9,10-dihydrodiol-glucuronide. The resulting dosimetry model described BAP and 7,8-dihydrodiol toxicokinetics in ALI-HBECs and suggested active excretion of 7,8-dihydrodiol. Overall, this study demonstrates metabolic competency of ALI-HBECs for BAP metabolism, demonstrates the usefulness of complex in vitro systems for human-relevant toxicity data, and exhibits how in silico models can be utilized for understanding the dosimetry of test compounds to aid in in vitro to human extrapolation of toxicity data for risk assessments.

Benzo[a]pyrene↗

X-ray Inspection Model Validation with Physical Dosimetry

A non-functional printed circuit board assembly was developed using ULTIboard and a simple computational transport model was created for use with the Monte Carlo software MCNP. EBT 3 film radiography was used to compare with Monte Carlo simulation to validate the board representation. The computational transport model was then revised to include connection pins, solder balls, highly attenuating internal structures, and copper trace distribution. Results from the revised model were compared to the EBT 3 films to observe improvements to dose profiles. It was found that this method was useful in verifying the placement of components, as the dose profiles were observed to follow the same trends. The experiment was then repeated using XRQA 2 films to achieve the same level of contrast with 1% the dose of EBT 3 films. It was found that high contrast may be achieved using these films to identify major issues with the model geometry, at a cost of dose profile accuracy. A second validation method was applied to the model using 37 CaF 2 thermoluminescent dosimeters (TLDs). TLD measurements were compared with the simplified and complex transport models to identify the features that have the greatest impact on simulation accuracy. The TLD calibration to CaF 2 was found to be accurate within 5.6%, while calibration to dose in Si was found to be accurate within 4.7%. Finally, it was observed that the accurate representation of solder balls and proper modeling of highly attenuating internal structures had the greatest impact on simulation accuracy.

61 RADIATION PROTECTION AND DOSIMETRY↗