Search NASA⌕ Search

SEARCH · Search NASA

Results for “doubly-fed induction generator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Robust Disturbance Rejection Rotor Current Control of Doubly-Fed Induction Generators

This article proposes a robust transient disturbance rejection current controller (TDRCC) to improve the transient performance of doubly-fed induction generators (DFIGs) in wind turbines during grid disturbances, such as short circuits. Here, the proposed robust TDRCC replaces the proportional-integral-derivative (PID) current controllers conventionally used in the vector control scheme of the DFIG rotor side converter (RSC). The TDRCC estimates the transient disturbances caused by grid faults or other external disturbances and provides compensation to the DFIG rotor voltage in the current control loops of the RSC to improve the robustness of the controller to disturbance. A sliding-mode current controller (SMCC) is also designed to highlight the transient performance improvement of the DFIG using the TDRCC over the state-of-the-art control methods during grid short circuit faults. Simulation studies are conducted in PSCAD/EMTDC for a 3.6-MW DFIG wind turbine with the proposed TDRCC, the conventional PI controller, and the SMCC, respectively during the most severe balanced three-phase grid short circuit fault specified by the U.S. grid code as well as an unbalance single-phase grid short circuit fault. Hardware experiments are conducted on a 200-W DFIG wind turbine emulator with the three different controllers for the same three-phase short circuit fault. Simulation and hardware experiment results show that the TDRCC reduces the peak rotor current significantly when compared with the PI and SMCC controlled DFIG system and, therefore, would help prolong the lifespan of the DFIG's power electronics and reduce maintenance costs.

42 ENGINEERING↗

Data-Driven Adaptive Damping Controller for Wind Power Plants with Doubly-Fed Induction Generators

This paper presents an adaptive damping controller for wind power plants in which the turbines are equipped with doubly-fed induction generators. The controller is designed to respond to an input control signal that is triggered according to the system operating conditions. A processing unit continuously estimates the electromechanical modes of oscillation based on real-time streaming data acquired from a phasor measurement unit that is strategically positioned on the grid. The decision to trigger (or not trigger) the control signal is automatic, based on the relative damping of the dominant mode. The modes are estimated using the dynamic mode decomposition algorithm with time-delay embedding. Numerical simulations performed on the two-area system demonstrate that the proposed controller enhances the rotor angle stability for both small-signal and large disturbances, and is adaptive to changing grid conditions.

damping controller↗

Characterization of Impedance and Stability for Doubly-Fed Induction Generator Based on Voltage-Modulated Direct Power Control

Voltage-modulated direct power control (VM-DPC) applied to the doubly-fed induction generator (DFIG) offers superior steady-state and transient performance but remains underexplored for suppressing wideband oscillations. Here, this article proposes a comprehensive impedance for the VM-DPC-based DFIG, analyzing its impedance characteristics and stability mechanisms compared with the DFIG based on vector-oriented control (VOC). The unified power transfer function is defined for DFIGs employing VM-DPC or VOC to ensure consistent comparison benchmarks. The comprehensive impedance of VM-DPC-based DFIG, incorporating mechanical and grid-side converter (GSC) dynamics, is derived using complex vector modeling in the αβ -frame. Furthermore, the influence of VM-DPC parameters and grid strength on the stability of grid-connected DFIG systems is assessed through eigenvalue trajectory analysis. Impedance analysis reveals the significant contributions of mechanical and GSC dynamics to DFIG impedance, as well as the narrower frequency range of negative resistance in the VM-DPC-based DFIG compared to the VOC-based DFIG. Stability analysis identifies the VM-DPC parameters of the rotor-side converter as dominant factors affecting system stability and confirms that the VM-DPC-based DFIG achieves better stability under weak grid conditions than its VOC-based counterpart. These findings are validated through simulations and experiments.

42 ENGINEERING↗

Dynamic P-Q Capability and Abnormal Operation Analysis of a Wind Turbine with Doubly-Fed Induction Generator

After several accidents occurred in wind farms in the United States and around the world, the subsynchronous oscillation (SSO) issues in grid-connected wind farms have gained serious attention. Particularly, these issues have caused significant challenges to wind turbines with a doubly fed induction generator (DFIG) because it is connected to the grid via both its stator and rotor paths. Traditionally, a P-Q capability chart is utilized to assure the safe operation boundary for a synchronous generator. But the energy conversion characteristics of a DFIG wind turbine are completely different. A critical factor to affect the reliable operation of a DFIG wind turbine is the rated current and pulse-width modulation (PWM) saturation constraints of its power converters. These constraint conditions can be affected by the wind turbine rotating speed and grid conditions. However, a detailed study of DFIG P-Q capability from these perspectives has not been conducted, which has hindered adequate understanding of many abnormal wind turbine operations reported in the literature and the development of advanced control technologies to overcome the challenges. The proposed study in this paper considers vector control implementation to DFIG power electronic converters in the dq reference frame, and the models and algorithms developed for the P-Q capability study have addressed specific DFIG power converter constraints that are different from those of a traditional synchronous generator. The paper especially focuses on exploring the dynamic natures of DFIG P-Q capability under uncertain and variable conditions to explore the root causes of many abnormal operations of DFIG wind turbines reported in the literature. The proposed study is validated through an electromagnetic transient simulation model of a grid-connected DFIG wind turbine. The proposed study has the potential to lead to the development of new DFIG control technologies that can help overcome the challenges for many abnormal operations of DFIG wind turbines.

17 WIND ENERGY↗

Reduced Switching Frequency Finite Control Set Model Predictive Control (FCS-MPC) for DFIG

An enhanced Finite Control Set Model Predictive Control (FCS-MPC) strategy with a two-step prediction horizon for a Doubly-Fed Induction Generator (DFIG) is the focus of this paper. The DFIG and RL filter's discrete-time model is used in the proposed control scheme for a two-step prediction horizon of rotor and filter currents for the converter's eight possible switching states. Afterward, the control algorithm selects the ideal switching state, which minimizes currents' objective function. The proposed control scheme does not require a modulation stage for internal controllers. We use Lagrange extrapolations to predict the dynamic changes in currents. The switching frequency reduction is achieved by integrating an optimization constraint in the algorithm's cost function. Furthermore, the Total Harmonic Distortion level of currents is kept below 5%, according to IEEE Std 519-14. Obtained results reveal that the switching frequency of the DFIG converters is considerably reduced without losing control; it is reduced by 13.89KHz for the Grid Side Converter (GSC) and by 1.78KHz for the Rotor Side Converter (RSC).

doubly-fed induction generator↗

Cooperative fault management for resilient integration of renewable energy

Cooperative fault management (CFM) is designed herein to control different types of renewable energy resources cooperatively during electrical faults. This paper studies systems with a high penetration of photovoltaic (PV) energy and wind energy. First, CFM leverages power converters of PV farms to boost the ride-through capability of nearby doubly-fed induction generators (DFIGs). By controlling PV farms’ output voltages to change smoothly during both fault initiation and fault clearance, the widely used crowbar in DFIGs is less likely to be activated. Crowbar activation adversely makes DFIGs lose controllability and absorb reactive power. The second contribution is the development of a software-defined CFM controller and a controller in-the-loop demonstration of the real-time performance of this optimization-based CFM. CFM capitalizes on distributed optimization formulation to enable flexibility, plug-and-play, and privacy-preserving. Computation time, however, is a major concern for optimization-based dynamics control. Here, real-time controller-in-the-loop simulation results show optimization-based CFM can output reference values around 60 ms and is quick enough for dynamic control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Integrated Reference Region Analysis for Parallel DFIGs’ Interfacing Inductors

Although the traditional design of doubly-fed induction generators (DFIGs)’ interfacing inductors consider the peak ripple of the grid-side converter (GSC)’s output current, it does not consider the inductors’ impact on DFIGs’ smallsignal stability. Located in series between the GSC and the stator, the inappropriate selection of the interfacing inductor can easily result to system instability. Therefore, this paper first proposes the integrated reference region analysis for small wind farm's interfacing inductors to improve the traditional design method. Firstly, a new detailed parallel DFIGs’ smallsignal model that considers output currents’ coupling is built in d-q coordinate system with state-space approach. The model focuses on representing the operating states of parallel DFIGs in wind farm. Secondly, the linearized state-space matrix of parallel DFIGs is decomposed into nominal-value matrix and location matrix. Considering the traditional design requirements, the integrated reference region for interfacing inductor is proposed through spectral radius and bialternate matrix sum (BMS). Furthermore, it can provide better guidance for parameter selecting and stabilization method researches. Finally, the simulation and experimental results show that the proposed integrated reference region for parallel DFIGs’ interfacing inductors is accurate and instructive.

47 OTHER INSTRUMENTATION↗

Blackstart and Fault Ride-Through Capability of DFIG-Based Wind Turbines

Grid-forming wind turbines must be able to re-energize transmission branches, motor loads, unbalanced loads, and power electronics loads following a blackout. Further, they must ride through faults that can arise during restoration. To tackle these challenges, this paper sets forth a grid-forming control strategy for wind turbines using doubly-fed induction generators (DFIGs). In particular, a special set of feedforward control loops are engineered to mitigate the impacts of restoration transients as well as symmetrical and asymmetrical faults on the regulation of DFIG rotor currents and stator voltages. This paper also leverages two-axis anti-windup regulators to bound two-axis voltage and current commands within ratings. As a result, the controller performance is demonstrated via a high-fidelity simulation model of a notional wind-dominant grid.

17 WIND ENERGY↗

Proposal and Development of a High Voltage Variable Frequency Alternating Current Power System for Hybrid Electric Aircraft

The development of ultra-efficient commercial vehicles and the transition to low-carbon emission propulsion are seen as strategic thrust paths within NASA Aeronautics. A critical enabler to these paths comes in the form of hybrid electric propulsion systems. For megawatt-class systems, the best power system topology for these hybrid electric propulsion systems is debatable. Current proposals within NASA and the Aero community suggest using a combination of alternating current (AC) and direct current (DC) for power generation, transmission, and distribution. This paper proposes an alternative to the current thought model through the use of a primarily high voltage AC power system, supported by the Convergent Aeronautics Solutions (CAS) Project. This system relies heavily on the use of doubly-fed induction machines (DFIMs), which provide high power densities, minimal power conversion, and variable speed operation. The paper presents background on the activity along with the system architecture, development status, and preliminary results.

Sadey, David J.↗