Search NASA⌕ Search

SEARCH · Search NASA

Results for “drift tube”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Upgrade to Fixed and Translating Scintillation-based Loss Detector System in the Fermilab Drift Tube Linac

The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and operational assessment of Drift Tube Linac performance, scintillator-based loss monitors were previously installed along the exterior of the first two accelerating cavities to assess low energy beam losses. Here we present a recent upgrade to the loss monitor system, including significant improvements in analog signal processing to address baseline-interfering noise; digitization of the signals to enable regular operational use and tuning; and a new remote operation upgrade of the translating loss monitor with precise positioning of the loss monitor along its nine-foot track. Data from the fixed and translating detectors collected under varying beam conditions validate the utility of the upgrade.

Chen, E. V. [Fermilab]↗

Upgrade to Fixed and Translating Scintillation-Based Loss Detector System in the Fermilab Drift Tube Linac

The closed-off structure of the Fermilab Drift Tube Linac precludes a robust array of instrumentation from directly monitoring the H- beam that is accelerated from 750 keV to 116 MeV. To improve beam tuning and op-erational assessment of Drift Tube Linac performance, scintillator-based loss monitors were previously installed along the exterior of the first two accelerating cavities to assess low energy beam losses. Here we present a recent upgrade to the loss monitor system, including significant improvements in analog signal processing to address baseline-interfering noise; digitization of the signals to enable regular operational use and tuning; and a new remote operation upgrade of the translating loss monitor with precise positioning of the loss monitor along its nine-foot track. Data from the fixed and translating de-tectors collected under varying beam conditions validate the utility of the upgrade.

Chen, Erin V. [Fermilab] (ORCID:0000000215467899)↗

Beam Tuning Setups for Drift Tube Linacs

Various matching methods for tuning Drift Tube Linacs are overviewed. Special emphasis is on the methods utilizing signature phase scans with single and pairs of Beam Position Monitors (BPM) placed inside or outside of the tuned-up cavity, and that using a combination of phase scans with energy scans.

43 PARTICLE ACCELERATORS↗

Proportional drift tubes for large area muon detectors

A proportional drift chamber which consists of eight rectangular drift tubes with cross section of 10 cm x 5 cm, a sense wire of 100 micron phi gold-plated tungsten wire and the length of 6 m, was tested using cosmic ray muons. Spatial resolution (rms) is between 0.5 and 1 mm over drift space of 50 mm, depending on incident angle and distance from sense wire.

Cho, C.↗

A 24-channel ultra-low-noise preamplifier for dN/dx measurements with drift tube detectors

Cluster counting $(dN/dx)$ is a promising method to enhance particle identification for gaseous detectors, especially in next-generation collider experiments like the FCC-ee, where good $π/K$ separation over a broad momentum range is essential. However, its implementation in large-scale systems has been limited by the challenging requirements for high-resolution signal amplification and readout. This paper presents a 24-channel ultra-low-noise preamplifier board designed for drift tube detectors to enable $dN/dx$ measurements. The three-stage amplification topology employs SiGe transistors and integrates dedicated noise-minimization techniques, achieving a charge gain of 21.11 mV/fC from 0.3 fC to 50 fC, a bandwidth of 542 MHz, and a voltage gain of 47.8 dB. The measured voltage noise density is 0.35 nV/$\sqrt{\textrm{Hz}}$ , surpassing most of the state-of-the-art preamplifiers for gaseous and silicon detectors. Validation tests conducted on the sMDT chambers at the CERN Proton Synchrotron test beam facility demonstrate that the proposed design meets the stringent preamplifier requirements for implementing the $dN/dx$ method in drift-tube detector systems, achieving an equivalent noise charge of 0.14 fC and a signal-to-noise ratio of 73 when operated with a He:iC 4 H 10 (90:10) gas mixture. The design also shows promise for broader application in other gaseous or semiconductor detectors.

Drift tube detector↗

Beam Loss Monitoring with Fixed and Translating Scintillation Detectors Along the Fermilab Drift-tube Linac

The Fermilab Linac is a roughly 145 meter linear accelerator that accelerates H- beam from 750 keV to 400 MeV and provides beam for the Booster and the rest of the accelerator chain. The first section of the Linac is a Drift-Tube Linac (DTL), which in its current state, suffers from a lack of instrumentation along its length. As a result, operational staff do not have access to the diagnostic information needed to tune the critical components of this accelerator, such as the quadrupole magnets within the drift tubes. This work presents an effort to utilize both fixed and translating scintillation detectors to investigate beam loss along the first two cavities of the DTL.

43 PARTICLE ACCELERATORS↗

RF Power Estimates for LAMP Drift-Tube Linac

The LANSCE Modernization Project (LAMP) concept includes a drift-tube proton linac (DTL) from 3 MeV to 100 MeV consisting of 6 tanks. This technical note provides estimates of RF power required for the LAMP DTL tanks using DTLfish modeling.

43 PARTICLE ACCELERATORS↗

Design and fabrication of the waveguide Iris couplers for the Spallation Neutron Source drift tube linac

The Spallation Neutron Source (SNS) employs six cavities in the Drift Tube Linac (DTL) section to accelerate the H- ion beam to 87MeV. Each cavity is energized by a 2.5MW peak power klystron at 402.5MHz using rapid tapered waveguide iris couplers. All six original iris couplers have been in operation without replacement for over two decades. The increased RF power demands of the Proton Power Upgrade (PPU) project and operational problems, including arcing, temperature excursions, and vacuum bursts, have prompted the development of new iris coupler spares. The original iris couplers were made of GlidCop material, which is known to be mechanically strong and thermally stable, but is porous, expensive, and difficult to use in fabrication. To overcome these problems, the new spare couplers use Oxygen-Free Copper (OFC) and stainless steel (SS). This paper will discuss the mechanical, thermal and RF design, as well as challenges in the final coupler fabrication.

Lee, Sung-Woo↗

Development and test of a mini-Data Acquisition system for the High-Luminosity LHC upgrade of the ATLAS Monitored Drift Tube detector

New front-end electronics including ASICs and FPGA boards are under development for the ATLAS Monitored Drift Tube (MDT) detector to handle the large data rates and harsh environment expected at high-luminosity LHC runs. A mobile Data Acquisition (miniDAQ) system is designed to perform integration tests of these front-end electronics. In addition, it will be used for surface commissioning of 96 small-radius MDT (sMDT) chambers and for integration and commissioning of new front-end electronics on the present ATLAS MDT chambers. Details of the miniDAQ hardware and firmware are described in this article. Here, the miniDAQ system is also used to read out new front-end electronics on an sMDT prototype chamber using cosmic muons and results obtained are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using dimethylether as a drift gas in a high precision drift tube detector

Excellent spatial resolution (34 microns) has been obtained using dimethylether, (CH3)2O at 1 atm in a small drift tube detector. This is better by at least a factor of 2 compared to previous work (about 80 microns) with a conventional gas (a 50-50 argon-ethane mixture) in the same detector. The Lorentz angle and the gas amplification have been measured over a wide range of electric and magnetic fields.

Zhou, B.↗

Design of a Time-to-Digital Converter ASIC and a mini-DAQ system for the Phase-2 upgrade of the ATLAS Monitored Drift Tube detector

We present the second prototype of a time-to-digital (TDC) ASIC for the upgrade of the ATLAS Monitored Drift Tube (MDT) detector for High-Luminosity LHC operations. Compared to the first prototype, triple modular redundancy has been implemented for the configuration and flow control logic. Here, the total power consumption is increased by less than 10 mW while achieving the same time resolution and channel uniformity. A mini-DAQ system has been built to verify the front-end electronics chain with the new prototype together with other ASICs and boards in triggered mode. Cosmic ray tests with a small-diameter MDT chamber indicate that the configuration and data transmission of the readout electronics perform well. It is expected that this prototype design will be used in the final production.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multipacting analysis of the SNS drift tube linac (DTL) RF vacuum window using Spark3d

An ongoing study at the Spallation Neutron Source (SNS) seeks to better understand and address potential multipacting issues associated with the Drift Tube Linac (DTL) RF vacuum windows. An analysis of several failed operational windows showed indications of excessive RF heating on the TiN-coated alumina ceramics. Coupled with vacuum bursts and arcing during conditioning and/or operational periods, these problems have been attributed to electron activity likely caused by multipacting. The status of the study, 3-D electromagnetic simulation results, mitigating techniques and a future experimental plan for studying multipacting in the SNS DTL vacuum windows are presented.

Toby, George↗

A low-frequency buncher field-variation study on a 750 keV H – beam to increase Drift Tube Linac capture

We report low-frequency (such as 16.77 MHz) RF bunchers are widely used in RF accelerator systems for longitudinal compression of pulses into a single RF bucket, which increases instantaneous beam intensity for time-dependent studies. In this study, the dependency of capture into a 201.25 MHz Drift Tube Linac (DTL) was measured as a function of gap voltage for a 16.77 MHz buncher on chopped H - beam (approximately 25 ns at 750 keV, 10 mA peak current). The multiparticle code PARMILA was used to simulate the phase-space distribution of the 10 mA, 750 keV, H - beam at the entrance to DTL with a wide range of the Low-Frequency Buncher (LFB) field (10 kV to 35 kV). The measurement and simulation indicated that the DTL capture could be dilute (reduced) for a non-optimized buncher field to a pre-configured beamline geometry. The data shows that changing the bunch field while keeping the incoming beam current and energy constant does not significantly alter the beam’s emittance. However, downstream beam capture into the DTL is changed for a non-optimized phase-space bunching distance with the buncher field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of Benzene, Toluene, and Xylene by means of an ion mobility spectrometer device using photoionization

The continuous monitoring of changes on the quality of ambient air is a field of advantage of ion mobility spectrometry. Benzene, Toluene, and Xylene are substances of special interest because of their toxicity. We present an optimized drift tube for ion mobility spectrometers, which uses photo-ionization tubes to produce the ions to be analyzed. The actual version of this drift tube has a length of 45 mm, an electric field strength established within the drift tube of about 180 V/cm and a shutter-opening-time of 400 mus. With the hydrogen tube used for ionisation a mean flux of 10(exp 12) photons/sq cm s was established for the experiments described. We discuss the results of investigations on Benzene, Toluene, and Xylene in normal used gasoline SUPER. The detection limits obtained with the ion mobility spectrometer developed in co-operation are in the range of 10 ppbv in this case. Normally, charge transfer from Benzene ions to Toluene takes place. Nevertheless the simultaneous determination in mixtures is possible by a data evaluation procedure developed for this case. The interferences found between Xylene and others are rather weak. The ion mobility spectra of different concentrations of gasoline SUPER are attached as an example for the resolution and the detection limit of the instrument developed. Resolution and sensitivity of the system are well demonstrated. A hand-held portable device produced just now is to be tested for special environmental analytical problems in some industrial and scientific laboratories in Germany.

Leonhardt, J. W.↗

Hypervelocity impact facility for simulating materials exposure to impact by space debris

The Space Power Institute at Auburn University has constructed an electromagnetically driven particle accelerator for simulating the effects of space debris on the materials for use in advanced spacecraft. The facility consists of a capacitively driven accelerator section, a drift tube and a specimen impact chamber. The drift tube is sufficiently long that all electrical activity has ceased prior to impact in the specimen chamber. The impact chamber is large enough to allow a wide range of specimen geometries, ranging from small coupons to active portions of advanced spacecraft. The electric drive for the accelerator consists of a 67 kJ, 50 k capacitor bank arranged in a low inductance configuration. The bank is discharged through an aluminum armature/plastic ablator plate/projectile load in roughly 1.2 microsec. The evaporation of the ablaitor plate produces an expanding gas slug, mostly H2, traveling at a velocity of some 60 km/sec. Because of the pressure and local density, the expanding gas cloud accelerates projectiles due to plasma drag. To date, we have utilized projectiles consisting of 100 micron SiC, 100 and 400 micron Al2O3, 100 and 145 micron olivines. Since many particles are accelerated in a given experiment, there is a range of velocities for each shot as well as some particle breakup. Advanced diagnostics techniques allow determination of impact coordinates, velocity, and approximate size for as many as 50 individual impacts in a given experiment. We routinely measure velocities in the range 1-15 km/sec. We have used this facility to study a variety of impact generated phenomena on coated surfaces, both paint and plastic, thermal blanket material, solar cell arrays, and optical materials such as glass and quartz lenses. The operating characteristics of the gun, the advanced diagnostic scheme, and the results of studies of crater morphology are described in detail. Projectile residue analysis, as a function of impact velocity for the materials listed above, is also discussed. Wherever possible, these results are compared to those obtained by LDEF investigators and future experiments suggested which could help to explain unique features associated with LDEF impacts.

Rose, M. Frank↗

Active Divertor Heat Flux Control using Impurity Powder Dropper

Divertor plasma-facing components (PFCs) in a tokamak are typically designed to withstand average steady-state heat loads of about 5–10 MW/m 2 , a limit that applies to both solid and liquid lithium (LL) PFCs. Exceeding these design values can result in surface damage to tungsten PFCs or excessive lithium (Li) evaporation in liquid lithium divertor (LLD) PFCs. Since exceeding the divertor heat load limits has serious consequences, it is therefore prudent to develop a tool to reduce the divertor heat load and bring the heat load to within the design limit without affecting the plasma performance. Active low Z impurity injection such as Li has been suggested as a potential solution to mitigate excess heat flux as suggested previously, given that non-coronal radiation can be quite large ~ 20–30 MJ per mole of injected Li. Li is considered desirable for reducing the edge neutral recycling helping to improve plasma energy confinement. In this paper, we model the Impurity Power Dropper (IPD) to investigate its potential of divertor heat flux control. The IPD is typically located at the top of the tokamak device and uses a vertical drift tube of a few meters. In the 2 m drift tube case, the IPD powder is accelerated to ~ 6 m/sec before reaching the plasma with the upper divertor configuration, matching the condition for the in-board side pellet injection case. By modeling the IPD geometry we determined the IPD powder deposition profile, and thus the non-coronal radiation and ionization profiles in time as well. From the enhanced radiation power loss, it is therefore possible to reduce the divertor heat load using the divertor simulation code. In conclusion, the IPD divertor heat flux control can be tested in the facilities with IPD including ST-40, DIII-D, EAST, WEST and NSTX-U.

Active lithium injection↗