Search NASA⌕ Search

SEARCH · Search NASA

Results for “drop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Drop clustering and drop size correlations from holographic imagery suggest cloud droplet spectral broadening via entrainment-mixing

The question of how droplets rapidly grow large enough to initiate collision-coalescence has persisted for decades. Many theories explaining the production of sufficiently large drops (i.e., those in the “bottleneck” size range; ∼ 25–50 µm diameters) involve drop clustering on millimeter scales. A novel method is introduced to evaluate drop clustering trends particle-by-particle (i.e., the number/proximity of neighboring drops for given droplets; defined as drop clustering fields) which are diagnosed relative to drops within their shared drop environments – in contrast to previous studies which diagnose drop clustering of defined sample volumes, or in terms of absolute length scales. Specifically, this study evaluates the statistical likelihood that drops of a given size are associated with either a significant number of neighboring drops, or are significantly isolated from neighboring drops. Observations are acquired from the HOLODEC during the Cloud System Evolution in the Trades campaign, which sampled subtropical marine clouds. The HOLODEC measures drop size distributions and the 3D spatial coordinates of droplets. Results show drops within the bottleneck size range (diameters of ∼ 25–50 µm) are most likely to be significantly isolated from neighboring drops. This “isolated large drop trend” is primarily observed at subsaturated conditions, suggesting entrainment is the contributing factor. Holograms associated with this trend are more likely to have broader drop size distributions, larger maximum drop sizes and overly regions where precipitation reaches the lowest altitudes from the sampled cloud, suggesting entrainment-mixing drop size distribution broadening is a relevant precipitation-initiation mechanism.

D'Alessandro, John J. [Univ. of Washington, Seattl↗

Evaluating Entrainment–Mixing Characteristics through Direct Comparisons of Drop Size Distributions Using In Situ Observations from ACE-ENA

Abstract Constraining the impacts of entrainment and associated mixing (i.e., entrainment–mixing) on cloud properties continues to be difficult, partly due to observational uncertainties as well as a lacking consensus of which methodologies for diagnosing entrainment–mixing are most appropriate. This study introduces a novel method to evaluate the presence and degree of inhomogeneous and homogeneous mixing using ∼100 h of in situ observations from a research aircraft over the northeastern Atlantic. Specifically, drop size distributions are compared between regions containing negligible and significant entrainment for select flight legs, making a direct characterization of the degree of homogeneous and inhomogeneous mixing possible. A measure of drop concentration variance is used as a proxy variable to diagnose entrainment–mixing. Results correspond well with entrainment–mixing metrics, showing lower Damköhler numbers where drop size distributions shift toward smaller drop sizes (i.e., inhomogeneous mixing) and greater transition length scales where drop size distributions do not (i.e., homogeneous mixing). Inhomogeneous mixing occurs in most samples from Aerosol and Cloud Experiment in the Eastern North Atlantic (ACE-ENA) (regardless of homogeneous mixing frequencies increasing with increasing spatial resolution from ∼100 to ∼10 m) and is associated with decreased drop size relative dispersion and both greater aerosol and drop concentrations compared with homogeneous mixing. Precipitating clouds have a greater frequency of homogeneous mixing compared with nonprecipitating clouds. The proposed methodology is similarly applied to in situ observations of southeast Pacific stratocumulus, shallow convective clouds over central Oklahoma and low-level clouds over the Southern Ocean. All four locations are primarily dominated by inhomogeneous mixing with minimal variability among each region.

Clouds↗

Impulse-driven release of gas-encapsulated drops

Gas-encapsulated drops, much like antibubbles, are drops enclosed in a bubble within a liquid. They show potential as payload carriers in fluid transport and mixing techniques where sound waves can be leveraged to induce the collapse of the gas core and the subsequent release of the drop. Here, the interaction of millimetre-sized gas-encapsulated drops with impulsive laser-induced shock waves is investigated to gain fundamental insights into the release process. Experimental synchrotron X-ray phase contrast imaging, which allows the drop dynamics to be visualised inside the encapsulating bubble, is complemented by numerical simulations to study the intricate physics at play. Three drop dynamical release regimes are discovered, namely the drop impact , partial deposition and jet impact regimes. The regime type is mainly dependent on the shape of the bubble interface impacting the drop and the associated Weber and Reynolds numbers. The drop dynamics of the drop impact and partial deposition regimes show similarities with the canonical configuration of drops impacting flat liquid surfaces, whereas the jet impact regime resembles binary drop collisions, which allows existing scaling laws to be applied to describe the underlying processes. The release of the drop is investigated numerically. The time evolution of the drop dissemination within the surrounding liquid discloses enhanced mixing for dynamics involving high Weber and Reynolds numbers such as the drop impact and jet impact regimes.

42 ENGINEERING↗

SAVY-4000 Finite-Element Drop Test Analysis

PFE Auxiliary Systems conducted drop testing on SAVY-4000 containers to evaluate structural response under 12-foot drop conditions. In support of that effort, a finite-element modeling capability was developed to simulate drop response across multiple container sizes and impact orientations. The purpose of this work was to provide a consistent analysis framework that could support interpretation of testing, compare response trends across multiple configurations, and generate quantities of interest for later comparison with experimental data. More broadly, the analysis and testing were intended to assess whether the containers continued to perform their primary function after a 12-foot drop, namely maintaining structural integrity and containment of the contents. The modeling approach combined an implicit preload analysis with an explicit drop simulation so that each drop event began from a mechanically realistic assembled condition, including compression of the silicone O-ring. Separate models were developed for 2-quart, 5-quart, 12-quart, and 10-gallon containers. The results were evaluated in terms of strain-gauge response, collar-lid gap behavior, and accumulated plastic strain. In addition, parametric studies were performed on the 2-quart container to assess sensitivity to O-ring stiffness, friction, canister thickness, geometry tolerance, and mesh density. The simulations showed that predicted drop responses depended strongly on both container size and drop orientation. Gap metrics identified cases in which the predicted collar-lid opening exceeded the nominal O-ring cross-section threshold, while plastic strain metrics identified localized regions of elevated permanent deformation. Parametric studies showed that the predicted response was especially sensitive to the assumed O-ring stiffness and contact friction, while the geometry tolerance study produced smaller changes in the cases examined. The main value of this work was that it established a repeatable modeling and simulation workflow to support drop-test implementation, evaluate effects of future configuration changes, and understand modeling assumptions that most influenced predicted response. At the current stage, the results were viewed as preliminary model predictions rather than validated predictions. The next step would be to compare drop-test data to the model so that predictive values of the workflow could be refined and used with greater confidence to assess whether the containers maintained structural integrity and containment of the contents after a 12-foot drop.

42 ENGINEERING↗

DROP DURABILITY ASSESSMENT OF ELECTRONIC ASSEMBLIES UNDER OFF-AXIS LOADING WITH SKEWED FIXTURES

This thesis studies drop durability of electronic assemblies when the acceleration vector is oriented at 45° to the out-of-plane direction of the circuit card. The off-axis drop tests are accomplished with a skewed fixture and are conducted as a proxy for multiaxial drop testing. Advanced shock testing and vibration test methods have been developed over the last few decades to better represent real-world field environments during ground-based laboratory testing. However, many of these test methods require expensive and specialized equipment not available in most laboratories. An alternative approach for approximating simultaneous loading along multiple axes on conventional equipment utilizes skewed fixtures which have seen use in off-axis random vibration and drop impact testing. These methods generally rely on the conversion of a uniaxial input load from the test equipment (using a uniaxial drop tower or shaker) into a multiaxial load when resolved in the reference frame of the test article (mounted on a skewed fixture). Skewed fixture design is presented and recommendations for conducting skewed angle drop testing are introduced based on local measurements along the skewed face of the fixture to accurately monitor the impact event. Characterization tests were performed with a skewed fixture, at simultaneous acceleration loads from 500 to 3,000 g in two (in-plane and out-of-plane) directions, while meeting standard time domain tolerances. Upon experimental characterization, drop shock durability tests were conducted on a printed circuit assembly (PCA). Mean drops-to-failure were measured and quantified with Weibull statistics. Dominant solder joint failure modes were identified via failure analysis. Prior work on inclined angle impact testing is limited, and the majority of solder joint interconnect level fatigue studies are conducted considering perpendicular loading normal the circuit card. Low-cycle fatigue curves are generated based on plastic strain and plastic work density within the solder joint. A multiscale nonlinear finite element model is used to relate board-level flexure to solder joint interconnect level plastic strain. A high strain rate solder constitutive model allows for accurate modeling of solder plasticity resulting from high-impact drop shock. Fatigue parameters are computed from the Coffin-Manson relation and Palmgren-Miner damage accumulation. This work serves to apply established low-cycle fatigue methods for conventional drop shock loading (impact normal to circuit card) to non-perpendicular loading with a skewed fixture.

Hower, Jonathan [Kansas City National Security Cam↗

Overview of the SCEC/USGS Community Stress Drop Validation Study Using the 2019 Ridgecrest Earthquake Sequence

We present initial findings from the ongoing Community Stress Drop Validation Study to compare spectral stress-drop estimates for earthquakes in the 2019 Ridgecrest, California, sequence. This study uses a unified dataset to independently estimate earthquake source parameters through various methods. Stress drop, which denotes the change in average shear stress along a fault during earthquake rupture, is a critical parameter in earthquake science, impacting ground motion, rupture simulation, and source physics. Spectral stress drop is commonly derived by fitting the amplitude-spectrum shape, but estimates can vary substantially across studies for individual earthquakes. Sponsored jointly by the U.S. Geological Survey and the Statewide (previously, Southern) California Earthquake Center our community study aims to elucidate sources of variability and uncertainty in earthquake spectral stress-drop estimates through quantitative comparison of submitted results from independent analyses. The dataset includes nearly 13,000 earthquakes ranging from M 1 to 7 during a two-week period of the 2019 Ridgecrest sequence, recorded within a 1° radius. Here, in this article, we report on 56 unique submissions received from 20 different groups, detailing spectral corner frequencies (or source durations), moment magnitudes, and estimated spectral stress drops. Methods employed encompass spectral ratio analysis, spectral decomposition and inversion, finite-fault modeling, ground-motion-based approaches, and combined methods. Initial analysis reveals significant scatter across submitted spectral stress drops spanning over six orders of magnitude. However, we can identify between-method trends and offsets within the data to mitigate this variability. Averaging submissions for a prioritized subset of 56 events shows reduced variability of spectral stress drop, indicating overall consistency in recovered spectral stress-drop values.

58 GEOSCIENCES↗

Experimental and Computational Study of Weld Drop-Through Hydraulic Effects in Multi-Layer Concentric Pipes Servicing Cryogenic Liquid Hydrogen

The Cryogenic Moderator System (CMS) at the Oak Ridge National Laboratory (ORNL)-Spallation Neutron Source (SNS) supplies liquid hydrogen, through vacuum insulated transfer lines to the moderators. The welding process used to make the transfer lines produces weld drop-through, which can constrict the flow of hydrogen and/or cause thermal bridges between adjacent layers. To ensure proper operation of the CMS it is therefore necessary to conduct a flow test to verify the pressure drop caused by the welds. Measurements in as-built piping sections intended to provide liquid hydrogen service to the SNS-CMS system were performed to test the effect of weld penetrations into the fluid flow area focusing on pressure drop effects. The reference test sections were designed using prototypical piping dimensions, materials and expected penetration welds. A numerical study using Computational Fluid Dynamics (CFD) tools in the transfer lines provided a conversion factor from the pressure drop measured in the lines with water to the expected pressure drop using liquid cryogenic hydrogen. The results show evidence of a maximum pressure drop modification in water of 78 KPa in the tested parts, which scales to liquid hydrogen as PHydrogen = 5.2 KPa. The maximum measured equivalent blockage area percentage was found in the as-built TDM transfer line spool 2 with a value of 31%. The measured values obtained in the as-built transfer lines provided accurate values to estimate the expected total pressure drop in the CMS system providing operational limits for the current recirculatory capacity. The effect of the weld drop-through in hydrogen evacuation capacity scenarios was better evaluated as a result of this study.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

Construction of 3D MHD pressure drop correlation and flow characterization in the contraction region of a fusion blanket manifold

Inlet and outlet manifolds are typical components of liquid metal (LM) blanket designs of a fusion power reactor to be used to distribute the LM flow into breeding channels and collect it at the exit of the blanket. High pressure loss in the magnetohydrodynamic (MHD) flows featuring abrupt geometrical changes is one of the main feasibility issues of such designs. Recently, optimization studies were conducted to construct 3D MHD pressure drop correlations for a LM flow in an electrically insulating manifold with gradual expansion. Here, the 3D computational approach developed in that study is applied to the outlet manifold featuring gradual contraction. A systematic analysis was performed with a total number of 135 flow cases computed with COMSOL Multiphysics for Hartmann numbers 1000 < Ha < 10,000, Reynolds numbers 100 < Re < 12,000, and contraction angles 45° < θ < 75° for a fixed contraction ratio of 4. The effects of Ha, Re and θ on the flow recirculation, development length and the total pressure drop were carefully examined. A linear regression analysis was used to determine the power rule of pressure drop coefficient k related to Ha and Re, demonstrating a good match with the Ludford layer theory. Eventually, a correlation for the 3D MHD pressure drop coefficient was constructed as a function of Ha, Re and θ. Further, the results were compared against the inlet manifold. It was found that the flow in the inlet manifold exhibits larger recirculation zones. In the investigated range of Ha, Re and θ, the pressure drop coefficient k of the LM MHD flow in the gradual contraction is only slightly lower (< 8 %) than that in the gradual expansion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation and optimization of flow boiling frictional pressure drop correlations using the data from traditional and next-generation refrigerants in a micro-fin tube

This study presents an experimental evaluation and optimization of flow boiling frictional pressure drop correlations for conventional and next-generation refrigerants in a horizontal micro-fin tube, with particular emphasis on the newly emerging refrigerant blends R-454C and R-455A, for which pressure-drop data in enhanced tubes remain limited. Experiments were conducted with R-410A, R-454C, R-455A, R-134a, R-1234yf, and R-1234ze(E) in a copper micro-fin tube with an inner diameter of 8.468 mm, over mass fluxes ranging from 100 to 300 kg/(m²·s) depending on the refrigerant, and evaporation temperatures of 7, 12, and 14 °C. Frictional pressure gradients were determined from measured total pressure drops after subtracting acceleration pressure drop, and the resulting database was used to assess four existing models: Kuo and Wang (1996), Cavallini et al. (1997), Goto et al. (2001), and Diani et al. (2014). The measured frictional pressure gradient increased with vapor quality and mass flux for all refrigerants and increased further at lower evaporation temperatures, with the overall trend strongly related to liquid viscosity. Among the four correlations, the Goto et al. (2001) model provided the best overall agreement with the measured data before optimization. To further improve prediction accuracy, the Kuo and Wang (1996) and Goto et al. (2001) models were optimized using the complete experimental database. After optimization, both models reduced the overall mean absolute deviation to below 15%, while the optimized Goto et al. (2001) model maintained the best and most consistent overall performance. The results provide new pressure-drop data for next-generation refrigerants and demonstrate that parameter optimization can significantly enhance the applicability of existing micro-fin-tube correlations.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Density drop at the divertor target in the prototype material plasma exposure eXperiment (Proto-MPEX)

The steady-state linear device “Material Plasma Exposure eXperiment” (MPEX) is currently under construction at Oak Ridge National Laboratory with the goal of enabling Plasma-Material Interaction studies at future fusion reactor relevant plasma conditions. In this work, a newly in-house developed hybrid Particle-In-Cell code-PICOS++ is applied to understand the experimental results obtained from the prototype of MPEX referred to as the “Proto-MPEX” during its helicon-only and helicon with ion cyclotron resonance heating (ICRH) experiments. This study explains the physics of the experimentally observed plasma density-drop at the divertor target in Proto-MPEX device during ICRH. In contrast to previous work on ICRH in MPEX, this study demonstrates that the mirror force plays a central role in the Proto-MPEX plasma transport during ICRH, which has new features not previously explored. Force balance analyses reveal that the temperature anisotropy produced by ICRH leads to a significant increase in the mirror force downstream of the resonance where the magnetic field is diverging. This force accelerates ions toward the target and leads to a drop in plasma density to ensure conservation of particle flux. Simulations with ICRH where the magnetic field divergence downstream of the resonance has been removed, do not produce plasma acceleration nor density drop at the target despite efficient ion heating at the resonance. Moreover, simulation results demonstrate that for a given ICRH power, lowering the source rate produces ions with increased perpendicular energy which interact with the mirror force to produce higher plasma acceleration which increases the strength of the density-drop at the target. The strength of the density drop appears to reach an asymptotic limit at a certain threshold ICRH power. Simulations show that this threshold power increases with increasing particle source rate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Factors That Influence Variability in Stress-Drop Measurements Using Spectral Decomposition and Spectral-Ratio Methods for the 2019 Ridgecrest Earthquake Sequence

Stress drop is a fundamental parameter related to earthquake source physics, but is hard to measure accurately. To better understand how different factors influence stress-drop measurements, we compare two different methods using the Ridgecrest stress-drop validation data set: spectral decomposition (SD) and spectral ratio (SR), each with different processing options. Here, we also examine the influence of spectral complexity on source parameter measurement. Applying the SD method, we find that frequency bandwidth and time-window length could influence spectral magnitude calibration, while depth-dependent attenuation is important to correctly map stress-drop variations. For the SR method, we find that the selected source model has limited influence on the measurements; however, the Boatwright model tends to produce smaller standard deviation and larger magnitude dependence than the Brune model. Variance reduction threshold, frequency bandwidth, and time-window length, if chosen within an appropriate parameter range, have limited influence on source parameter measurement. For both methods, wave type, attenuation correction, and spectral complexity strongly influence the result. The scale factor that quantifies the magnitude dependence of stress drop show large variations with different processing options, and earthquakes with complex source spectra deviating from the Brune-type source models tend to have larger scale factor than earthquakes without complexity. Based on these detailed comparisons, we make a few specific suggestions for data processing workflows that could help future studies of source parameters and interpretations.

58 GEOSCIENCES↗

The Role of Normal Stress and Shear Stress Heterogeneity in the Inferred Depth‐Independence of Stress Drop

Earthquake stress drops are inferred to be independent of source depth, contradicting linear scaling predictions for earthquakes as frictional stick‐slip instabilities that assume increasing fault normal stress due to overburden. Here, we examine the scaling between averaged stress drops and increasing normal stress for simulated earthquake sequences in continuum rate‐and‐state fault models. The models produce a weaker dependence of stress drop on normal stress than the linearity of simple friction, which can be well‐fit by a sublinear power‐law. This result is more prominent when the fault dimension is much larger than nucleation scales. In such cases, the averaged behavior of ruptures is dominated by rupture propagation conditions, reflecting more heterogeneous shear stress conditions. As natural faults can be considerably larger than the smallest earthquakes they host, such a weaker scaling between averaged rupture conditions and normal stress may partially explain the lack of an inferred depth‐dependence of earthquake stress drops.

earthquake source↗

Lifetime extension drop-test of real-world corroded 5 Quart Hagan nuclear material storage container

A 5Qt Hagan container with a 20-year history of nuclear material storage was challenged with three successive drop tests at a height of 3.7 meters. The total mass of the test package was 12.1 kg. The 1st and 2nd drop tests (center of gravity over the container bottom corner but 180 degrees apart on the container bottom face) passed the pre- and post- impact helium leak criterion at less than 1.00E-6 atm-cc/sec (ambient cubic centimeters per second). The 3rd and final test (center of gravity over top corner) failed with a post-impact gross leak of 1.1E-1 atmcc/sec. The RRFMC (Respirable Release Fraction Measurement Chamber) is a drop tower test system that is critical for the sustainability of the SAVY-4000™ series and Hagan-type (NFT Inc. Golden CO) nuclear material storage containers. These are the primary in-use nuclear material storage container types at the Los Alamos National Laboratory TA-55 facility. Results are presented to expand the technical knowledge basis for container lifetime, regarding actual exposure to corrosive gas species on the container inner surfaces. The primary source of general corrosion throughout the container is gaseous hydrogen chloride (HCl). This gas is generated by the degradation of the polyvinylchloride (PVC) bag-out bag. Additionally, in most cases, the nuclear material itself also releases HCl gas (due to residual chemical components associated with the material formation). The RRFMC drop tower gives the end-user the ability record and analyze high-speed video and photography and if needed aerosol mass release measurements. In this report the principal issue is the physical deformation of the 5Qt Hagan container. There were no mass release experiments of test aerosol mass in the present study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improvement of Drop‐Hammer Impact Testing for Safety Assessment of High Explosives Using 10‐mg Samples

Here, in this study, we established an improved method for drop-hammer impact testing of small quantities of high explosives (10 mg). We performed about seven hundred impact tests under various experimental conditions (e.g., sandpaper vs bare anvil, different sample masses, drop-weights, and striker diameters) to determine an optimal set of conditions and reaction detection methods (e.g., gas analysis, video, and sound recordings) that give the most statistically reliable results with 10 mg samples. We used both Frequentist and Bayesian statistical approaches to compare estimates of the drop height (DH50) that initiates a reaction 50% of the time, and to quantify the associated uncertainty. Gas analysis proved to be the most reliable reaction detection method, showing unambiguous rises in HE decomposition products (e.g., CO 2 ) even when the other indicators (e.g., sound, video) were inconclusive. The impact tests performed with a bare anvil showed much better reproducibility than those conducted with sandpaper, reducing the largest uncertainty observed in the data sets by a factor of 1.7. The DH 50 values obtained from three different sample masses (10, 20, and 35 mg) fell within the uncertainties of the measurements. We demonstrated the improved procedure (i.e., 10-mg samples, gas analysis, bare anvil, and Bayesian approach) on a variety of PETN samples having different surface areas and thermal histories.

PETN↗

Ultra-low thermal resistance and pressure drop copper and copper-tungsten diamond-shaped pin fin cold plates for liquid cooling of electronics

Modern and future data centers face increasing cooling challenges due to increasing chip thermal design power and die size, along with the need to reduce energy consumption used for cooling. High performance cooling solutions that maintain a low chip junction temperature are needed to ensure electronics reliability. This work develops an ultra-low thermal resistance and low pressure drop 75 mm × 75 mm cold plate, intended for next-generation electronics cooling. The cold plate features an array of diamond-shaped pin fins and integrated copper tungsten heat spreader, selected for its low coefficient of thermal expansion which reduces thermomechanical deformation and allows for closer integration of the cold plate with silicon dies. Starting with 300 candidate designs, three-dimensional computational fluid dynamics simulations predict the thermal-hydraulic performance of cold plate subsections. The highest performing geometries are evaluated with high fidelity simulations. Four cold plates are manufactured for experiments: three with diamond-shaped pin fins and one with straights fins for comparison purposes. The cold plates are fabricated from copper-tungsten (CuW), copper (Cu), or aluminum-silicon-magnesium alloy (AlSi10Mg). The diamond-shaped pin fins achieve a roughly 15 % lower thermal resistance compared to the conventional straight fin microchannel. The highest performing design achieves a chip-to-coolant (including thermal interface material) thermal resistance of 9.0 K/kW in CuW and 6.9 K/kW in Cu under a 1 kW heat load with an inlet-to-outlet pressure drop of 9.0 kPa and water as the working fluid. This work demonstrates ultra-low thermal resistance and pressure drop cold plates for large die, high heat load applications, and shows that CuW is an attractive cold plate material for improved reliability in next generation data center cooling.

Coefficient of thermal expansion↗

Enhancement of mid-/high-Z impurity transport by continuous Li-granule dropping in a stellarator plasma

An enhancement of core impurity transport is observed in high-density plasmas of the stellarator large helical device, heated by neutral beam injection, when continuous lithium (Li) granule dropping is performed. In the reported experiments, in which the tracer-encapsulated solid pellet is employed to inject trace amounts of titanium (Ti) and molybdenum (Mo) into the plasma core, confinement times for these impurities are seen to reduce significantly when Li dropping is applied, this reduction being more notable for Mo. To gain some initial insight into these observations, simulations are performed using the drift-kinetic transport code SFINCS for the Mo case. These simulations indicate that, while neoclassical transport prevails for the main plasma components (electrons, majority ions, and low-Z impurities), the classical contribution appears dominant for transporting Mo impurities. In summary, this work reports the first experimental observation of the degradation of mid-Z and high-Z impurity confinement induced by the continuous dropping of Li granules into a high-density stellarator plasma. In the case of the Mo impurity, simulations suggest that classical transport is the key mechanism underlying the enhanced impurity transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Drop Tower Statement of Work

This document details the needs and requirements for a propulsion-assisted drop tower system (further referenced simply as Drop Tower) to perform hardware testing at Lawrence Livermore National Laboratory (LLNL). LLNL is managed and operated by Lawrence Livermore National Security, LLC (LLNS) for the Department of Energy (DOE). LLNL requires a robust testing platform that will allow for the characterization of interactions between objects of interest. The initial siting of the equipment will be located in an existing test facility (B191). When another test facility becomes online, the objective will be to move the test capability to the new facility as a final location (B132N). The Drop Tower will be a cornerstone capability for testing and model validation for LLNL interested programs.

42 ENGINEERING↗

Optimization of Triply Periodic Minimal Surface Heat Exchanger to Achieve Compactness, High Efficiency, and Low-Pressure Drop

With advancements in additive manufacturing (AM) techniques, high-quality triply periodic minimal surface (TPMS) structures can now be produced. TPMS walled heat exchangers (HX) hold significant potential for industrial applications and are receiving increasing attention. This paper explores the impact of various TPMS design variables on flow and thermal performance to optimize TPMS heat exchangers for compactness, high efficiency, and low pressure drop. The design variables examined include the type of TPMS lattice, unit cell size, wall thickness, aspect ratio, TPMS orientation, and equivalent thickness. The study reveals that the flow and heat transfer performance of TPMS structures are significantly affected by these design variables. For the Gyroid, Diamond, and SplitP lattices, performance is nearly identical when the surface-to-volume ratio is kept constant. The average velocity of the fluid in the TPMS HX should be 0.3 m/s. The corresponding Re is between 300~800. Thin wall thickness, small equivalent thickness, and flat lattice configurations can significantly reduce pressure drop while maintaining the overall heat transfer coefficient. Additionally, the angle between the flow direction and TPMS orientation can increase pressure drop. Three aluminum heat exchangers were successfully printed using an AM machine, and testing results are comparable with theoretical prediction.

42 ENGINEERING↗