Developing a Feasible Pathway from Wet Cooling to Dry Cooling for Thermoelectric Power Generation via Engineered Fluids.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
This study (completed by US Department of Energy, National Energy Technology Laboratory) investigates the performance, cost, and generating capacity impacts of switching from wet cooling towers to dry cooling systems to reduce consumptive water use at existing fossil fuel-fired power plants in a water-stressed region. Here, retrofit analysis of dry cooling is conducted on a unit-by-unit basis for both coal-fired and gas-fired power plants in several western U.S. states. Based on regional averages, retrofitting dry cooling systems in lieu of wet cooling towers decreases total annual plant water consumption at existing coal- and gas-fired power plants by 93% and 100%, respectively, while increasing the levelized cost of electricity generation by approximately 12% and 18%, respectively. Over the year, the change in monthly net regional generating capacity from dry cooling retrofits exhibits a seasonal pattern, with the largest shortfalls occurring in July. Dry cooling retrofits thus lead to tradeoffs in water savings, cost, and capacity shortfalls, which vary with power plant characteristics. The tradeoffs identified here can inform electric power industry water management plans and decision-making for alternative cooling options in water-stressed regions.
Not Available
A seasonal process that captures stores and uses water in an ambient temperature-dependent manner to improve the efficiency of a natural gas power plant, comprising: (a) providing a natural gas power plant, the natural gas power plant having a flue gas stream, a cooling tower, and a gas turbine; (b) providing a water collection system; (c) providing a water storage facility; wherein the flue gas stream comprises uncondensed water vapor; wherein the water collection system is operably connected to the flue gas stream and the flue gas stream is directed to flow, at least in part, into the water collection system; wherein the water collection system is operably connected to the water storage facility; wherein the water storage facility is operably connected to the cooling tower and the water storage facility is operably connected to the gas turbine; wherein the process comprises the following steps of condensing flue gas water or using water that has been condensed from the flue gas stream based on outdoor ambient dry bulb temperature: (I) Only condensing water from the flue gas stream to produce a condensed water stream if outdoor ambient dry bulb temperature is less than 85° F.; (II) Only using condensed water to spray cool the cooling tower if outdoor ambient dry bulb temperature is at least 85° F.; (III) Only using condensed water to fog cool the gas turbine if outdoor ambient dry bulb temperature is at least 55° F.; wherein condensed water that is not immediately used to cool the cooling tower or to fog cool the gas turbine is stored in the water storage facility; and wherein the process uses a total amount of water on an annual basis to cool the cooling tower and to fog cool the gas turbine that does not exceed the annual amount of water condensed from the flue gas stream. Optionally, the process has a cooling tower that is a dry cooling tower and condensed water is used to spray cool the dry cooling tower, or the cooling tower is a wet cooling tower, or the cooling tower is a hybrid wet-dry cooling tower. The process may further comprise a water collection system having a three stage desiccant cycle and a calcium chloride desiccant that recovers at least about 60 wt % of the water from the flue gas, operates at or above ambient pressure or comprises plastic piping or plastic vessels. Or the process may further comprise using a water collection system having at least one direct contact condensing column that recovers at least about 60 wt % of the water from the flue gas, operates at or above ambient pressure or comprises plastic piping or plastic vessels. Or the process may further comprise using a water collection system having at least one direct contact condenser and a rotating wheel heat exchanger that recovers at least about 60 wt % of the water from the flue gas, operates at or above ambient pressure, or further comprises plastic piping or plastic vessels. The coefficient of performance for the cooling process is optionally at least 2.0.
Cooling systems in power plants account for approximately 40% of total freshwater withdrawals in the U.S. Due to dwindling access to freshwater resources worldwide, continued operation of wet cooling systems poses a significant engineering challenge. To reduce water consumption, a novel air-cooled heat exchanger has been developed using encapsulated phase change material (EPCM) for dry cooling of power plants. Compared to traditional finned-tube air-cooled condensers, this novel EPCM heat exchanger improves the heat transfer coefficient and power plant efficiency while reducing the pressure drop and cooling system cost. Life cycle assessment (LCA) and techno-economic analysis (TEA) are used to evaluate the environmental and economic performance of EPCM heat exchangers from cradle-to-grave and to compare them to wet cooling and traditional air-cooled condensers. A thermodynamic model is developed to predict the EPCM heat exchanger performance for plant-scale operations. Equipment and construction costs for heat exchangers are estimated based on design parameters obtained from the thermodynamic model. Both process-LCA and economic-input–output LCA are used to simulate and test the sensitivity of EPCM alternatives with commercial wet and dry cooling technologies. We investigate options for EPCM end-of-life management upon retiring the heat exchanger and construct a process-based LCA model to estimate a greenhouse gas (GHG) emissions credit for recycling the EPCM. The life cycle GHG emission of the novel dry cooling technology is 1.16 kg CO 2 eq. /MWh compared with the 1.1–4.3 kg CO 2 eq. /MWh reported for commercial dry cooling technologies and consumes 9.5 L/MWh e of water for cradle-to-gate life cycle, which is significantly lower than that of wet cooling systems. The TEA shows many advantages of EPCM cooling technology over the state-of-art dry cooling solutions. Overall, the EPCM heat exchanger provides a better alternative compared to existing dry cooling and wet cooling technologies.
The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.
The University of North Dakota’s Energy & Environmental Research Center (EERC) is developing a market-focused dry cooling technology that is intended to address the key shortcomings of conventional dry cooling technologies: high capital cost and degraded cooling performance during daytime temperature peaks. The unique aspect of desiccant dry cooling (DDC) is the use of a hygroscopic working fluid—a liquid desiccant—as a heat-transfer medium between a power plant’s steam condenser and the atmosphere. This configuration enables a number of beneficial features for large-scale heat dissipation to the atmosphere, without the consumptive use of cooling water. The overall goal of this project was to accurately define the performance and cost characteristics of DDC to determine if further development of the concept is warranted. A balanced approach of modeling grounded in applied experimentation was pursued to substantiate DDC-modeling efforts and outline the potential for this technology to cool full-scale power plants. The resulting analysis shows that DDC can be a lower-cost dry cooling alternative to an air-cooled condenser (ACC) and can even be competitive with conventional wet recirculating cooling under certain circumstances. This project has also highlighted the key technological steps that must be taken in order to transfer DDC into the marketplace. To address these issues and to offer an extended demonstration of DDC technology, a next-stage project should include the opportunity for outdoor ambient testing of a small DDC cooling cell. This subtask was funded through the EERC–U.S. Department of Energy (DOE) Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FC26-08NT43291. Nonfederal funding was provided by the Wyoming State Legislature under an award made through the Wyoming Clean Coal Technologies Research Program.
This report concludes the LDRD entitled "Advanced SMRs using S-CO2 Power Conversion with Dry Cooling." The goal of this project was to demonstrate the feasibility of using sCO 2 as the working fluid in a dry-cooled natural circulation loop. The reason for doing this is to demonstrate that such a loop could be utilized in small modular reactors (SMRs) as a method for (a) passively removing decay heat from the reactor and (b) cooling the reactor without using the copious amounts of water needed for wet-cooled reactors. The dry-cooling aspect of this work is possible due to the working conditions of a sCO 2 Brayton power conversion cycle. The loop was designed, built, and operated over the three-year life of the LDRD project. This report outlines some of the key accomplishments and some of the future work that we are continuing to try to complete in the future. A more comprehensive report will be completed and submitted in the Fall of 2015.
Water scarcity and climate change are dual challenges that could potentially threaten energy security. Yet, integrated water–carbon management frameworks coupling diverse water- and carbon-mitigation technologies at high spatial heterogeneity are largely underdeveloped. Here we build a global unit-level framework to investigate the CO 2 emission and energy penalty due to the deployment of dry cooling—a critical water mitigation strategy—together with alternative water sourcing and carbon capture and storage under climate scenarios. We find that CO 2 emission and energy penalty for dry cooling units are location and climate specific (for example, 1–15% of power output), often demonstrating notably faster efficiency losses than rising temperature, especially under the high climate change scenario. Despite energy and CO 2 penalties associated with alternative water treatment and carbon capture and storage utilization, increasing wastewater and brine water accessibility provide potential alternatives to dry cooling for water scarcity alleviation, whereas CO 2 storage can help to mitigate dry cooling-associated CO 2 emission tradeoffs when alternative water supply is insufficient. By demonstrating an integrative planning framework, our study highlights the importance of integrated power sector planning under interconnected dual water–carbon challenges.
The attached cost and performance spreadsheet model is for an indirect dry cooling system, one of four cooling system models developed for use in optimizing indirectly-heated supercritical CO2 (sCO2) power cycles. Running the model requires that the user has REFPROP version 9 or below installed, as well as the Microsoft Excel REFPROP Add-In. Upon opening, use Excel’s Edit Links feature to link to the user’s installed REFPROP.xla or REFPROP.xlam file. For the spreadsheet model compatible with REFPROP version 10 and above, contact Nathan Weiland at nathan.weiland@netl.doe.gov. Technical documentation for the model can be found here: https://www.netl.doe.gov/energy-analysis/details?id=3199.
The attached cost and performance spreadsheet model is for a direct dry cooling system, one of four cooling system models developed for use in optimizing indirectly-heated supercritical CO 2 (sCO 2 ) power cycles. Running the model requires that the user has REFPROP version 9 or below installed, as well as the Microsoft Excel REFPROP Add-In. Upon opening, use Excel’s Edit Links feature to link to the user’s installed REFPROP.xla or REFPROP.xlam file. For the spreadsheet model compatible with REFPROP version 10 and above, contact Nathan Weiland at nathan.weiland@netl.doe.gov. Technical documentation for the model can be found here: https://www.netl.doe.gov/energy-analysis/details?id=3199.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Here, the work presented in this paper focuses on the design and thermal characterization of a novel polymer composite heat exchanger (HX) produced by an innovative additive manufacturing process. The heat exchanger represents a gas to liquid configuration in which the gas side removes heat from the liquid side in a cross-flow arrangement. The novel HX utilizes a cross media approach in which, unlike the conventional HXs, the hot and cold sides are directly connected to each other through high conductivity metal fiber fins on the gas side protruding through the walls of the liquid side, thus eliminating the wall resistance separating the hot and cold sides. The HX demonstrates superior thermal performance at reduced pressure drops while also benefiting from the lighter weight and the lower cost that the polymer structure introduces. A 350-W water-to-air heat exchanger was fabricated using a fused filament fabrication (FFF) technique with a novel/patent pending printer head which was developed to produce the metal fiber composite structure of the heat exchanger. The results of the heat exchanger characterization tests show that it yields up to 220% and 125% improvement in heat flow rate over mass ($Q/m$) and heat flow rate over volume ($Q/V$), respectively, when compared to comparable state-of-the-art plate fins HX configurations. This study in particular demonstrates the impact of additive manufacturing in realizing potentially transformative heat exchanger technologies that may otherwise be very difficult to achieve with conventional fabrication methods.
The second-generation particle size velocity (Parsivel2, Figure 1) disdrometer, or laser disdrometer, referred to as “LDIS” within the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) User Facility, is a modern, laser-based disdrometer designed for comprehensive and reliable measurement of all types of precipitation. LDIS captures detailed information on the size and velocity of individual hydrometeors that fall to the ground, classifying them into a range of 32 categories. These raw measurements are processed by a fast signal processor (provided by the vendor) to calculate various parameters, including precipitation type, amount, intensity, kinetic energy, visibility in the precipitation, and equivalent radar reflectivity. These measurements have served as the primary data set and a valuable reference for a variety of studies, ranging from observational analyses of precipitation processes and climate model evaluations to monitoring or validating radar/satellite retrievals (e.g., Wang et al. 2018, Giangrande et al. 2019, Jackson et al. 2020).
Abstract not provided.