Search NASA⌕ Search

SEARCH · Search NASA

Results for “dry zone”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Pressure falloff testing to characterize CO 2 plume and dry-out zone during CO 2 injection in saline aquifers

The fluid mobilities and the lateral extent of the CO 2 plume and the dry-out zone are among important unknowns required to effectively manage CO 2 storage in saline aquifers projects. These unknowns can be derived from pressure falloff testing which has been widely used to characterize the subsurface. This paper provides a three-region analytical solution for falloff pressure during the infinite-acting period of CO 2 injection in saline aquifers. The solution is derived using Laplace transformation technique of the governing diffusivity equations and the accompanying initial and boundary conditions. The exact solution is validated against numerical results obtained from a black-oil reservoir simulator for two cases. The solution is approximated into simple forms in real-time domain considering different time periods. Then, a graphical semi-log analysis technique based on the approximate solutions is provided as an interpretation tool of falloff tests where the fluid mobilities and the extents of dry-out zone and CO 2 plume can be inferred. The interpretation technique is applied to synthetic falloff test data to investigate its potential and reliability.

02 PETROLEUM↗

Experimental and computational design tools for industrial drying processes: Challenges in process‐limit prediction

Abstract The coating and drying of inks and slurries are important steps to manufacture a plethora of products. Drying processes, particularly, comprise energy‐intensive steps that affect product cost and quality. Prior work has highlighted failures of various multicomponent diffusivity models to conserve mass in dryer modeling and challenges in predicting process limits given variability in published values of key thermodynamic parameters. Herein, we develop a computational model and benchtop drying experiments to investigate these concerns for drying polymer‐laden coatings. Model predictions of process limits in a single‐zone drying oven demonstrate that published variability in Flory–Huggins parameter yields large variations in predicted operating temperatures above which blistering occurs. This indicates that caution should be exercised when choosing approaches to obtain or predict the Flory–Huggins parameter, and that both benchtop drying experiments and a set of additional experiments, such as sorption experiments, are needed to fully characterize and optimize a given drying process.

Parrish, Chance↗

Modeling and analysis of solvent removal during Li-ion battery electrode drying

In this paper, we study the design aspects and process dynamics of solvent removal from Lithium-ion battery electrode coatings. For this, we use a continuum level mathematical model to describe the physical phenomenon of cathode drying involving coupled simultaneous heat and mass transfer with phase change. Our results indicate that around 90% of solvent is removed in less than half of the overall drying time. We study the effect of varying temperature and air velocity on the drying process. We show that the overall drying energy can be reduced by at least 50% by using a multi-zone drying process. Also, the peak solvent flux can be reduced by at least 40%. We further present the effect of using an aqueous solvent instead of N-Methyl-2-pyrrolidone (NMP) in electrode drying. Our results indicate that Water dries nearly 4.5 times faster as compared to NMP and requires nearly 10 times less overall drying energy per kg of solvent.

25 ENERGY STORAGE↗

Climate Conundrum: A Wet or Dry European and Northern African Climate During the Middle Miocene

Abstract End of 21st‐century hydroclimate projections suggest an expansion of subtropical dry zones, with Mediterranean and Sahel regions becoming much drier. However, paleobotanical assemblage evidence from the middle Miocene (17‐12 Ma), suggests both regions were instead humid environments. Here we show that by modifying regional sea surface temperatures (SST) in an Earth System Model (CESM1.2) simulation of the middle Miocene, the increased ocean evaporation and integrated water vapor flux overrides any drying effects associated with warming‐induced land‐surface evaporation driven by atmospheric CO 2 concentrations. These modifications markedly reduce the bias in the model‐data comparison for this period. A vegetation model (BIOME4) forced with simulated climatologies predicts both regions were dominated by mixed forest, which is largely consistent with the paleobotanical record. This study unveils the potential for wetter subtropical Mediterranean climates associated with warming, presenting an alternative scenario from future drying projections with localized SST warming governing regional climate change.

Acosta, R. P.↗

Numerical Investigation of Novel Oxygen Blast Furnace Ironmaking Processes

Oxygen blast furnace (OBF) ironmaking process has the potential to realize “zero carbon footprint” production, but suffers from the “thermal shortage” problem. This paper presents three novel OBF processes, featured by belly injection of reformed coke oven gas, burden hot-charge operation, and their combination, respectively. These processes were studied by a multifluid process model. The applicability of the model was confirmed by comparing the numerical results against the measured key performance indicators of an experimental OBF operated with or without injection of reformed coke oven gas. Then, these different OBF processes together with a pure OBF were numerically examined in aspects of in-furnace states and global performance, assuming that the burden quality can be maintained during the hot-charge operation. The numerical results show that under the present conditions, belly injection and hot charge, as auxiliary measures, are useful for reducing the fuel rate and increasing the productivity for OBFs but in different manners. Hot charge should be more suitable for OBFs of different sizes because it improves the thermochemical states throughout the dry zone rather than within a narrow region in the case of belly injection. The simultaneous application of belly injection and hot charge leads to the best process performance, at the same time, lowering down hot-charge temperature to achieve the same carbon consumption and hot metal temperature as that achieved when applying the hot charge alone. This feature will be practically beneficial in the application of hot-charge operation. In addition, a systematic study of hot-charge temperature reveals that optimal hot-charge temperatures can be identified according to the utilization efficiency of the sensible heat of hot burden.

36 MATERIALS SCIENCE↗

Dynamic Amplification of Subtropical Extreme Precipitation in a Warming Climate

Projected precipitation changes in a warming climate vary considerably, spatially, and between intensities. The changes can be greater or less than the ~7% K -1 Clausius-Clapeyron (CC) prediction, owing to dynamic effects. Using two global-climate-model large ensembles, we quantify the dynamically induced changes to precipitation extremes from the present (1996–2005) to late-21st-century (2071–2080) climates, as a function of recurrence interval, focusing on the subtropics. We separate non-CC changes into a term proportional to the present-day vertical-velocity spatial pattern (i.e., an amplification or damping thereof by a constant factor) and a residual. The amplitude term varies with recurrence interval, approximately canceling (doubling) CC for moderate (large) extremes, increasing precipitation variability. Contrastingly, the residual is quasi-uniform across recurrence intervals but spatially heterogeneous, weakening extremes over dry zones. This residual may be related to Hadley cell expansion, although this explanation is insufficient to explain many features, and other possible mechanisms are discussed.

54 ENVIRONMENTAL SCIENCES↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the combined influence of fluid-rock interactions on reservoir properties and injectivity during CO 2 storage in saline aquifers

Complex fluid-rock interactions can occur during the injection of carbon dioxide (CO 2 ) into saline aquifers for sequestration, which may affect CO 2 injectivity and storage capacity. A comprehensive reactive transport model is established to analyze salt precipitation, CO 2 -water-rock geochemical reactions, and their effects on reservoir physical properties and injectivity. In addition, sensitivity analyses are conducted to investigate the main factors that affect fluid-rock interactions and injectivity with relevance for site selection for CO 2 storage. Results show that the back flow of formation water not only affects the salt precipitation but also affects the CO 2 -water-rock geochemical reactions, resulting in salt and calcite precipitations mainly occurring in the dry-out zone. However, most of the mineral dissolution/precipitation caused by CO 2 -water-rock reaction occurs in the two-phase and aqueous-phase zones, and their effect on reservoir porosity and permeability are small. A considerable amount of sodium chloride precipitates in the dry-out zone as brine is drawn by capillary action into this zone, with significant consequences for porosity, permeability and injectivity. The injection rate, salinity, capillary pressure–saturation relationships, and reservoir permeability strongly affect the distribution of salt precipitation. Finally, moderate injection rates, salinities, capillary pressures, and permeabilities all lead to favorable CO 2 injectivity.

54 ENVIRONMENTAL SCIENCES↗

Chemical and isotopic evolution of flowback fluids from the Utica Gas Shale Play, Eastern Ohio USA

For this work, hydraulic fracturing flowback fluids were collected from two Utica/Point Pleasant well pads in eastern Ohio. One site was in the wet gas zone (UPPW), while the site ~50 km south consisted of four wells on the same pad in the dry gas zone (UPPS). Samples of input fluids also were collected before and during hydraulic fracturing. Flowback fluids are Na-Ca-Cl brines with total dissolved salt (TDS) concentrations that increase over several months from ~100 to 200 g/L. The slightly higher TDS of the dry gas fluids are in part due to recycled flowback used as input fluids, and in part due to lower volume of water used in hydraulic fracturing. Concentrations of most major ions (Ca 2+ , Mg 2+ , Na + , Sr2 + , Fe, Mn, Cl – , Br – ) are similar for the five wells sampled, although small but systematic changes occur in the major element ratios over time. Most notably, an increase in the Sr/Cl ratio corresponds to an increase in the 87 Sr/ 86 Sr ratio in the fluids, suggesting interactions with a more radiogenic Sr source in the subsurface. Dissolved Ba concentrations and Ra activities were different between the two sites, reflecting a high SO 4 2– fluid used at the UPPW site, and water-rock reactions occurring during hydraulic fracturing at the UPPS site. Water oxygen (δ 18 O) and hydrogen (δD) isotopes for input fluids used in the UPPW4 well and fresh water used for the UPPS wells fall on the Global Meteoric waterline (GMWL). Flowback fluids from both sites are relatively enriched in δ 18 O and δD compared to the input, but do not appear to follow a simple mixing trend, suggesting reaction and isotopic exchange with carbonates and fractionation due to imbibition in the rock. Cl isotopes, δ 37 Cl in the FP fluids varied from ~ –0.43 to +0.13‰, the largest variation was observed in the earlier stages of flowback, while in the later stages δ 37 Cl exhibited a small but systematic increase over time, suggesting diffusion control of isotopic composition. Some of the trace species measured (dissolved Fe, Mn, thiosulfate and organic acids) do not follow the same trends as the major ions, suggesting contributions from input fluids, or microbially mediated reactions are exerting control on their concentrations. Input water chemistry exerts an important control on the Sr and Ba concentrations in flowback water. High SO 4 2– in the input fluids used for hydraulically fracturing the wet gas well leads to precipitation of barite-celestite in flowback fluids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uranium storage mechanisms in wet-dry redox cycled sediments

Biogeochemical redox processes that govern radionuclide mobility in sediments are highly sensitive to forcing by the water cycle. For example, episodic draining and intrusion of oxidants into reduced zones during dry seasons can create biogeochemical hot moments that change microbial activity, affect redox status of minerals, initiate changes in sediment gas and water transport, and stimulate release of organic carbon, iron, and sulfur. In the upper Colorado River Basin, water-saturation of organic-enriched sediments locally creates reducing conditions that accumulate U. Subsequently, fluctuating hydrological conditions introduce oxidants which may reach internal portions of these sediments and reverse their role to become secondary sources of U. Knowledge of the impact of hydrological variability on the alternating import and export of contaminants, including U, is required to predict contaminant mobility and short- and long-term impacts on water quality. In this study, we tracked U, Fe, and S oxidation state and speciation to characterize the variability in redox processes and related U solubility within a shallow fine-textured organic-enriched sediment at the legacy U ore processing site at Shiprock, NM. Previous studies have reported uranium speciation and behavior in permanently saturated fine-grained naturally reduced sediments. This is the first report of U behavior in fine-grained reduced sediments that are experience cyclic redox cycling due to seasonal fluctuations in moisture content. Our results support previous observations that reducing conditions are needed to accumulate U in sediments, but they dispute the expectation that U predominantly accumulates as U(IV); our data reveal that U may accumulate as U(VI) in equal proportion to U(IV). Surprisingly, high abundances of U(VI) confined in the reduced sediments suggests that redox cycling is needed to promote its accumulation. We propose a new process model, where redox oscillations driven by annual water table fluctuations, accompanied by strong evapotranspiration in low permeability sediments, promote conversion of U(IV) to relatively immobile U(VI), which suggests long-term U immobilization resistant to redox perturbations. This observation contradicts the common idea that U(IV) accumulated in reducing conditions is systematically solubilized and transported to groundwater during re-oxidation.

54 ENVIRONMENTAL SCIENCES↗

Performance assessment of active insulation systems in residential buildings for energy savings and peak demand reduction

Active insulation systems (AISs) in buildings are envelopes that integrate thermal insulation, thermal energy storage, and controls. Although different designs for AISs have been proposed in the literature, a comprehensive analysis of feasible AISs is lacking. This paper discusses the energy performance, peak demand reduction potential, and performance characteristics of an AIS that uses a concrete wall as thermal mass sandwiched between two solid-state thermal switches (STSs). These STSs change their thermal conductivity using an on/off metal switch to create or break a thermal bridge across the STS. This paper first describes the experimental setup, used to determine the ratio of thermal resistance during R-high (low thermal conductivity) and R-low (high thermal conductivity) states of the STSs. This ratio was then used in whole-building energy simulations to evaluate the performance of AIS walls across different climate zones with/without a freeze timer of 60 min. The timer was added to reduce the number of switches of STSs from one state to another, and hence the energy needed for these switches. Analysis of the switching frequency and interval of STSs, thermal conductivity of walls, impact of wall orientation, and heat transfer through the wall from the use of AIS at different climate zones/locations were performed. The simulation results show that the AIS can achieve energy savings ranging from ~980 to 2,290 kWh in a single-family home with a floor area of ~220 m 2 compared with an IECC 2018 baseline. We found the energy savings was higher in dry climate zones which represent 17% of residential buildings in the United States, compared to humid or marine climate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating indoor thermal resilience of passive and low-power cooling shelters for outdoor workers in India

India’s 231 million outdoor workers are exposed to deadly heat during heat waves. We report results from a simulation-based study that focuses on passive design of cooling shelters for the hot and dry climate zone of India. The goal is to design a cooler-than-outdoor shelter for outdoor workers’ intermittent rest and recovery from heat stress during their arduous outdoor work, to avoid heat-related morbidities and mortality. Expected indoor thermal conditions in low-cost cooling shelters deploying a range of passive designs and low-power active measures are investigated, consistent with the current Indian standards and practices, located in the city of Jodhpur in western India. Heat resilience of the shelter was measured with the predicted reduction of hazardous hours inside the shelter based on the wet-bulb globe temperature (WBGT) and extended heat index. These measures include improving the building envelope, installing cool roofs, using internal thermal mass, and natural ventilation. Additionally, a low-power active measure of using ventilation fans and ceiling fans is explored. EnergyPlus-based simulation results show that simple, commonly available measures, particularly natural ventilation and ceiling fans, achieve the most significant reductions in overheating danger hours, by 22% and 21%, respectively, while more complex or costly passive strategies yield only marginal additional benefits. Moreover, combined measure packages are identified that can reduce the indoor WBGT by 8 to 10 °C, eliminating overheating danger hours. These findings highlight the critical importance of scalable, low-cost, and easily deployable cooling solutions for developing resilient cooling shelters for vulnerable outdoor workers during heat waves in India.

building performance↗

Passive Antifrosting Surfaces Using Microscopic Ice Patterns

Despite exceptional recent advances in tailoring the wettability of surfaces, to date, no engineered surface can passively suppress the in-plane growth of frost that invariably occurs in humid, subfreezing environments. Here, we show that up to 90% of a surface can exhibit passive antifrosting by using chemical or physical wettability patterns to template “ice stripes” across the surface. As ice exhibits a depressed vapor pressure relative to liquid water, these sacrificial ice stripes siphon the supersaturated water vapor to keep the intermediate surface areas dry from dew and frost. Further, we show that when these sacrificial ice stripes are elevated atop microfins, they diffusively coarsen in a suspended state above the surface. As a result, the suspended state of the coarsening ice results in a diffusive growth rate an order of magnitude slower than frost coarsening directly on a solid substrate and should also minimize its adhesive strength to the surface.

36 MATERIALS SCIENCE↗

Calculating the Effects of Solids Input and Removal as a Temperature Control in the Advanced Scale Up Reactor Experiment (ASURE) Facility at NETL Using Aspen

The Advanced Scale Up Reactor Experiment (ASURE) facility at NETL is being designed to be a fuel-flexible multi-purpose reactor that can be used for pyrolysis/gasification or evaluation of other high pressure “circulating fluidized bed” (CFB) chemical processes. The initial system design calculations for pyrolysis/gasification are presented in this work showing the expected performance of the ASURE facility when used as a biomass conversion reactor. Several other areas of application include gasification of any carbonaceous fuel including biomass, coal, plastics, and other waste materials. The reactor can therefore be used to produce SYNGAS of various compositions and hydrogen as well as other high value chemicals resulting from a typical tuned gasification process. This paper discusses an ASPEN model of the facility, focusing on the riser of the CFB reactor and the solids recirculation loop. The ASPEN model divides the riser into two sections. A bottom section which receives ash, char and sand which have been recirculated from a return loop. In this section an inert fluidization gas, (N2 or CO2), is introduced which acts as the primary mover of the solids through the system. The bottom section is equipped with a restricted air feed so that the recirculated char can be partially oxidized. This oxidation process along with the inventory of recirculating sand are used to effectively control the temperature in the following two chemical conversion sections of the reactor which are the pyrolysis zone followed by a tar cracking zone. Fresh fuel is added to the pyrolysis zone and undergoes drying and devolatilization. The products ash, char, volatile matter, and water vapor exit the pyrolysis zone and enter the reaction block for tar cracking. Steam and CO2 gasification reactions will be incorporated into the tar cracking zone, however at the design operating temperature, conversion from these reactions is expected to be essentially zero. The unit when completed in 2026 will test mixtures of biomass, plastics, and waste coal. This presentation discusses the basic ASPEN engineering design model for this project and provides preliminary sensitivity studies to determine how the various parts of the reactor will perform.

ASSURE↗

Calculating the Effects of Solids Input and Removal as a Temperature Control in the Advanced Scale Up Reactor Experiment (ASURE) Facility at NETL Using Aspen

The Advanced Scale Up Reactor Experiment (ASURE) facility at NETL is being designed to be a fuel-flexible multi-purpose reactor that can be used for pyrolysis/gasification or evaluation of other high pressure “circulating fluidized bed” (CFB) chemical processes. The initial system design calculations for pyrolysis/gasification are presented in this work showing the expected performance of the ASURE facility when used as a biomass conversion reactor. Several other areas of application include gasification of any carbonaceous fuel including biomass, coal, plastics, and other waste materials. The reactor can therefore be used to produce SYNGAS of various compositions and hydrogen as well as other high value chemicals resulting from a typical tuned gasification process. This paper discusses an ASPEN model of the facility, focusing on the riser of the CFB reactor and the solids recirculation loop. The ASPEN model divides the riser into two sections. A bottom section which receives ash, char and sand which have been recirculated from a return loop. In this section an inert fluidization gas, (N2 or CO2), is introduced which acts as the primary mover of the solids through the system. The bottom section is equipped with a restricted air feed so that the recirculated char can be partially oxidized. This oxidation process along with the inventory of recirculating sand are used to effectively control the temperature in the following two chemical conversion sections of the reactor which are the pyrolysis zone followed by a tar cracking zone. Fresh fuel is added to the pyrolysis zone and undergoes drying and devolatilization. The products ash, char, volatile matter, and water vapor exit the pyrolysis zone and enter the reaction block for tar cracking. Steam and CO2 gasification reactions will be incorporated into the tar cracking zone, however at the design operating temperature, conversion from these reactions is expected to be essentially zero. The unit when completed in 2026 will test mixtures of biomass, plastics, and waste coal. This paper presents the basic ASPEN engineering design model for this project and provides preliminary sensitivity studies to determine how the various parts of the reactor will perform.

ASSURE↗