Search NASA⌕ Search

SEARCH · Search NASA

Results for “dual imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Beamline K11 DIAD: a new instrument for dual imaging and diffraction at Diamond Light Source

The Dual Imaging and Diffraction (DIAD) beamline at Diamond Light Source is a new dual-beam instrument for full-field imaging/tomography and powder diffraction. This instrument provides the user community with the capability to dynamically image 2D and 3D complex structures and perform phase identification and/or strain mapping using micro-diffraction. The aim is to enable in situ and in operando experiments that require spatially correlated results from both techniques, by providing measurements from the same specimen location quasi-simultaneously. Using an unusual optical layout, DIAD has two independent beams originating from one source that operate in the medium energy range (7–38 keV) and are combined at one sample position. Here, either radiography or tomography can be performed using monochromatic or pink beam, with a 1.4 mm × 1.2 mm field of view and a feature resolution of 1.2 µm. Micro-diffraction is possible with a variable beam size between 13 µm × 4 µm and 50 µm × 50 µm. One key functionality of the beamline is image-guided diffraction, a setup in which the micro-diffraction beam can be scanned over the complete area of the imaging field-of-view. This moving beam setup enables the collection of location-specific information about the phase composition and/or strains at any given position within the image/tomography field of view. The dual beam design allows fast switching between imaging and diffraction mode without the need of complicated and time-consuming mode switches. Real-time selection of areas of interest for diffraction measurements as well as the simultaneous collection of both imaging and diffraction data of (irreversible) in situ and in operando experiments are possible.

36 MATERIALS SCIENCE↗

Dual-Image Color Normalization to Enable High-Performance Concentrating Solar Optical Metrology

Concentrating Solar Power (CSP) requires precision mirrors, and these in turn require metrology systems to measure their optical slope. In this project we studied a color-based approach to the correspondence problem, which is the association of points on an optical target with their corresponding points seen in a reflection. This is a core problem in deflectometry-based metrology, and a color solution would enable important new capabilities. We modeled color as a vector in the [R,G,B] space measured by a digital camera, and explored a dual-image approach to compensate for inevitable changes in illumination color. Through a series of experiments including color target design and dual-image setups both indoors and outdoors, we collected reference/measurement image pairs for a variety of configurations and light conditions. We then analyzed the resulting image pairs by selecting example [R,G,B] pixels in the reference image, and seeking matching [R,G,B] pixels in the measurement image. Modulating a tolerance threshold enabled us to assess both match reliability and match ambiguity, and for some configurations, orthorectification enabled us to assess match accuracy. Using direct-direct imaging, we demonstrated color correspondence achieving average match accuracy values of 0.004 h, where h is the height of the color pattern. We found that wide-area two-dimensional and linear one-dimensional color targets outperformed hybrid linear/lateral gradient targets in the cases studied. Introducing a mirror degraded performance under our current techniques, and we did not have time to evaluate whether matches could be reliably achieved despite varying light conditions. Nonetheless, our results thus far are promising.

14 SOLAR ENERGY↗

SPECKLE SUPPRESSION THROUGH DUAL IMAGING POLARIMETRY, AND A GROUND-BASED IMAGE OF THE HR 4796A CIRCUMSTELLAR DISK

We demonstrate the versatility of a dual imaging polarimeter working in tandem with a Lyot coronagraph and adaptive optics to suppress the highly static speckle noise pattern-the greatest hindrance to ground-based direct imaging of planets and disks around nearby stars. Using a double difference technique with the polarimetric data, we quantify the level of speckle suppression, and hence improved sensitivity, by placing an ensemble of artificial faint companions into real data, with given total brightness and polarization. For highly polarized sources within 0.''5, we show that we achieve 3 to 4 mag greater sensitivity through polarimetric speckle suppression than simply using a coronagraph coupled to a high-order adaptive optics system. Using such a polarimeter with a classical Lyot coronagraph at the 3.63 m Advanced Electro-Optical System telescope, we have obtained a 6.5{sigma} detection in the H band of the 76 AU diameter circumstellar debris disk around the star HR 4796A. Our data represent the first definitive ground-based near-IR polarimetric image of the HR 4796A debris disk and clearly show the two outer ansae of the disk, evident in Hubble Space Telescope NICMOS/STIS imaging. Comparing our peak linearly polarized flux with the total intensity in the lobes as observed by NICMOS, we derive a lower limit to the fractional linear polarization of >29% caused by dust grains in the disk. In addition, we fit simple morphological models of optically thin disks to our data allowing us to constrain the dust disk scale height (2.5{sup +5.0} {sub -1.3} AU) and scattering asymmetry parameter (g = (cos {theta}) = 0.20{sup +.07} {sub -.10}). These values are consistent with several lines of evidence suggesting that the HR 4796A disk is dominated by a micron-sized dust population, and are indeed typical of disks in transition between those surrounding the Herbig Ae stars to those associated with Vega-like stars.

99 GENERAL AND MISCELLANEOUS↗

Integrated Dual Imaging Detector

A new type of image detector was designed to simultaneously analyze the polarization of light at all picture elements in a scene. The integrated Dual Imaging detector (IDID) consists of a lenslet array and a polarizing beamsplitter bonded to a commercial charge coupled device (CCD). The IDID simplifies the design and operation of solar vector magnetographs and the imaging polarimeters and spectroscopic imagers used, for example, in atmosphere and solar research. When used in a solar telescope, the vector magnetic fields on the solar surface. Other applications include environmental monitoring, robot vision, and medical diagnoses (through the eye). Innovations in the IDID include (1) two interleaved imaging arrays (one for each polarization plane); (2) large dynamic range (well depth of 10(exp 5) electrons per pixel); (3) simultaneous readout and display of both images; and (4) laptop computer signal processing to produce polarization maps in field situations.

Rust, David M.↗

TU-F-CAMPUS-I-02: Contrast Enhanced Cone Beam CT Imaging with Dual- Gantry Image Acquisition and Constrained Iterative Reconstruction-a Simulation Study for Liver Imaging Application

Purpose: Contrast time-density curves may help differentiate malignant tumors from normal tissues or benign tumors. Repetitive scans using conventional CT or cone beam CT techniques, which Result in unacceptably high dose, may not achieve the desired temporal resolution. In this study we describe and demonstrate a 4D imaging technique for imaging and quantifying contrast flows requiring only one or two 360° scans. Methods: A dual-gantry system is used to simultaneously acquire two projection images at orthogonal orientations. Following the scan, each or both of the two 360° projection sets are used to reconstruct an average contrast enhanced image set which is then segmented to form a 3D contrast map. Alternatively, a pre-injection scan may be made and used to reconstruct a pre-injection image set which is subtracted from the post-injection image set to form the 3D contrast map. Each of the two 360° projection sets is divided into 12 subsets, thus creating 12 pairs of 30° limited angle projection sets, each corresponding to a time spanning over 1/12 of the scanning time. Each pair of the projection sets are reconstructed as a time specific 3D image set with the maximum likelihood estimation iterative algorithm using the contrast map as the constraint. As a demonstration, a 4D abdominal phantom was constructed from clinical CT images with blood flow through the normal tissue and a tumor modeled and imaging process simulated. Results: We have successfully generated a 4D image phantom, and calculated the projection images. The time density curves derived from the reconstructed image set matched well with the flow model used to generate the phantom. Conclusion: Dual-gantry image acquisition and constrained iterative reconstruction algorithm may help to obtain time-density curves of contrast agents in blood flows, which may help differentiate malignant tumors from normal tissues or benign tumors.

60 APPLIED LIFE SCIENCES↗

Boron-based dual imaging probes, compositions and methods for rapid aqueous F-18 labeling, and imaging methods using same

A composition useful as a PET and/or fluorescence imaging probe a compound a compound of Formula I, including salts, hydrates and solvates thereof: ##STR00001## wherein R.sub.1-R.sub.7 may be independently selected from hydrogen, halogen, hydroxy, alkoxy, nitro, substituted and unsubstituted amino, cycloalkyl, carboxy, carboxylic acids and esters thereof, cyano, haloalkyl, aryl, X is selected from the group consisting of C and N; and A is selected of hydrogen, halogen, hydroxy, alkoxy, nitro, substituted and unsubstituted amino, alkyl, cycloalkyl, carboxy, carboxylic acids and esters thereof, cyano, haloalkyl, aryl, including phenyl and aminophenyl, and heteroaryl.

47 OTHER INSTRUMENTATION↗

Stochastic image reconstruction for a dual-particle imaging system

Stochastic image reconstruction has been applied to a dual-particle imaging system being designed for nuclear safeguards applications. The dual-particle imager (DPI) is a combined Compton-scatter and neutron-scatter camera capable of producing separate neutron and photon images. The stochastic origin ensembles (SOE) method was investigated as an imaging method for the DPI because only a minimal estimation of system response is required to produce images with quality that is comparable to common maximum-likelihood methods. Here, this work contains neutron and photon SOE image reconstructions for a 252Cf point source, two mixed-oxide (MOX) fuel canisters representing point sources, and the MOX fuel canisters representing a distributed source. Simulation of the DPI using MCNPX-PoliMi is validated by comparison of simulated and measured results. Because image quality is dependent on the number of counts and iterations used, the relationship between these quantities is investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time-of-flight neutron spectrum unfolding for mixed-oxide nuclear fuel and plutonium metal using a dual-particle imager

A dual-particle imager with sensitivity to both neutrons and photons has been developed for the detection of special nuclear material. This system has the capability to provide spectral information on detected sources that is useful for safeguard applications. In nuclear facilities with high photon background rates, neutron detection can aid in identification and verification capabilities. The dual-particle imager creates a reconstructed neutron spectrum by correlating neutron counts in pairs of liquid scintillators. The reconstructed spectrum, a combination of energy deposited and time-of-flight, contains resolution effects that blur the true, emitted source-spectrum. To reduce the impact of resolution effects, the reconstructed spectrum can be unfolded to create an estimated source spectrum. A statistical technique, maximum-likelihood expectation-maximization, has been shown to produce an unfolded result for Cf-252 and Am-Be. This technique requires a system response-matrix that contains reconstructed spectra for single neutron energies. Since measuring mono-energetic neutrons is difficult, the system-response-matrix is simulated. Monte Carlo modeling with MCNPX-PoliMi has been show to produce an accurate system response. This work expands on previous neutron unfolding results by showing results for mixed-oxide fuel and plutonium metal measured with the dual-particle imager. Furthermore these results also demonstrate the ability of the dual-particle imager to discrimination between spontaneous fission neutrons and (α,n) reaction neutrons.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IMAGE ANALYSIS ALGORITHMS FOR DUAL MODE IMAGING SYSTEMS

The level of detail discernable in imaging techniques has generally excluded them from consideration as verification tools in inspection regimes where information barriers are mandatory. However, if a balance can be struck between sufficient information barriers and feature extraction to verify or identify objects of interest, imaging may significantly advance verification efforts. This paper describes the development of combined active (conventional) radiography and passive (auto) radiography techniques for imaging sensitive items assuming that comparison images cannot be furnished. Three image analysis algorithms are presented, each of which reduces full image information to non-sensitive feature information and ultimately is intended to provide only a yes/no response verifying features present in the image. These algorithms are evaluated on both their technical performance in image analysis and their application with or without an explicitly constructed information barrier. The first algorithm reduces images to non-invertible pixel intensity histograms, retaining only summary information about the image that can be used in template comparisons. This one-way transform is sufficient to discriminate between different image structures (in terms of area and density) without revealing unnecessary specificity. The second algorithm estimates the attenuation cross-section of objects of known shape based on transition characteristics around the edge of the object’s image. The third algorithm compares the radiography image with the passive image to discriminate dense, radioactive material from point sources or inactive dense material. By comparing two images and reporting only a single statistic from the combination thereof, this algorithm can operate entirely behind an information barrier stage. Together with knowledge of the radiography system, the use of these algorithms in combination can be used to improve verification capability to inspection regimes and improve and substantially increase the likelihood of detecting material diversion.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Image reconstruction of shielded mixed-oxide fuel using a dual-particle imaging system

The dual-particle imaging system being developed at the University of Michigan was used at the Joint Research Centre in Ispra, Italy for measurements on samples of special nuclear material. A 1,150-g mixed-oxide (MOX) fuel sample was measured with various shielding configurations to determine how the presence of lead and/or polyethylene shielding degrades the system's ability to localize a source by simultaneous neutron and photon imaging. Three two-hour measurements were taken with the source shielded by an: a) 8-mm lead sheath and 5.1-cm lead bricks, b) 8-mm lead sheath and 6.5-cm polyethylene bricks, and c) 8-mm lead sheath, 5.1-cm lead bricks, and 6.5-cm polyethylene bricks. The 8-mm lead sheath was used in all cases to reduce the measured photon count rate. A “bare” measurement was also made by using only the 8-mm lead sheath, but the unexpected presence of additional sources has rendered the measurement unsuitable for comparison. Here, the resulting images show that the dual-particle imaging system is able to accurately localize the MOX canister in the presence of intervening material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A dual-band adaptor for infrared imaging

A novel imaging adaptor providing the capability to extend a standard single-band infrared (IR) camera into a two-color or dual-band device has been developed for application to high-speed IR thermography on the National Spherical Tokamak Experiment (NSTX). Temperature measurement with two-band infrared imaging has the advantage of being mostly independent of surface emissivity, which may vary significantly in the liquid lithium divertor installed on NSTX as compared to that of an all-carbon first wall. In order to take advantage of the high-speed capability of the existing IR camera at NSTX (1.6-6.2 kHz frame rate), a commercial visible-range optical splitter was extensively modified to operate in the medium wavelength and long wavelength IR. This two-band IR adapter utilizes a dichroic beamsplitter, which reflects 4-6 {mu}m wavelengths and transmits 7-10 {mu}m wavelength radiation, each with >95% efficiency and projects each IR channel image side-by-side on the camera's detector. Cutoff filters are used in each IR channel, and ZnSe imaging optics and mirrors optimized for broadband IR use are incorporated into the design. In-situ and ex-situ temperature calibration and preliminary data of the NSTX divertor during plasma discharges are presented, with contrasting results for dual-band vs. single-band IR operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anatomical noise in contrast-enhanced digital mammography. Part II. Dual-energy imaging

Purpose: Dual-energy (DE) contrast-enhanced digital mammography (CEDM) uses an iodinated contrast agent in combination with digital mammography (DM) to evaluate lesions on the basis of tumor angiogenesis. In DE imaging, low-energy (LE) and high-energy (HE) images are acquired after contrast administration and their logarithms are subtracted to cancel the appearance of normal breast tissue. Often there is incomplete signal cancellation in the subtracted images, creating a background “clutter” that can impair lesion detection. This is the second component of a two-part report on anatomical noise in CEDM. In Part I the authors characterized the anatomical noise for single-energy (SE) temporal subtraction CEDM by a power law, with model parameters α and β. In this work the authors quantify the anatomical noise in DE CEDM clinical images and compare this with the noise in SE CEDM. The influence on the anatomical noise of the presence of iodine in the breast, the timing of imaging postcontrast administration, and the x-ray energy used for acquisition are each evaluated.Methods: The power law parameters, α and β, were measured from unprocessed LE and HE images and from DE subtracted images to quantify the anatomical noise. A total of 98 DE CEDM cases acquired in a previous clinical pilot study were assessed. Conventional DM images from 75 of the women were evaluated for comparison with DE CEDM. The influence of the imaging technique on anatomical noise was determined from an analysis of differences between the power law parameters as measured in DM, LE, HE, and DE subtracted images for each subject.Results: In DE CEDM, weighted image subtraction lowers β to about 1.1 from 3.2 and 3.1 in LE and HE unprocessed images, respectively. The presence of iodine has a small but significant effect in LE images, reducing β by about 0.07 compared to DM, with α unchanged. Increasing the x-ray energy, from that typical in DM to a HE beam, significantly decreases α by about 2 × 10{sup −5} mm{sup 2}, and lowers β by about 0.14 compared to LE images. A comparison of SE and DE CEDM at 4 min postcontrast shows equivalent power law parameters in unprocessed images, and lower α and β by about 3 × 10{sup −5} mm{sup 2} and 0.50, respectively, in DE versus SE subtracted images.Conclusions: Image subtraction in both SE and DE CEDM reduces β by over a factor of 2, while maintaining α below that in DM. Given the equivalent α between SE and DE unprocessed CEDM images, and the smaller anatomical noise in the DE subtracted images, the DE approach may have an advantage over SE CEDM. It will be necessary to test this potential advantage in future lesion detectability experiments, which account for realistic lesion signals. The authors' results suggest that LE images could be used in place of DM images in CEDM exam interpretation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A dual wavelength imaging system for plasma-surface interaction studies on the National Spherical Torus Experiment Upgrade

A two-channel spectral imaging system based on a charge injection device radiation-hardened intensified camera was built for studies of plasma-surface interactions on divertor plasma facing components in the National Spherical Torus Experiment Upgrade (NSTX-U) tokamak. By means of commercially available mechanically referenced optical components, the two-wavelength setup images the light from the plasma, relayed by a fiber optic bundle, at two different wavelengths side-by-side on the same detector. Remotely controlled filter wheels are used for narrow bandpass and neutral density filters on each optical path allowing for simultaneous imaging of emission at wavelengths differing in brightness up to 3 orders of magnitude. Applications on NSTX-U will include the measurement of impurity influxes in the lower divertor strike point region and the imaging of plasma-material interaction on the head of the surface analysis probe MAPP (Material Analysis and Particle Probe). The diagnostic setup and initial results from its application on the lithium tokamak experiment are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Amorphous Ag 2-x Cu x S quantum dots: “all-in-one” theranostic nanomedicines for near-infrared fluorescence/photoacoustics dual-modal-imaging-guided photothermal therapy

Integrating dual-modal imaging and photothermal effect within a single nanosystem is an enormous challenge for current nanomedicine application. In this study, non-toxic amorphous Ag 2-x Cu x S quantum dots (QDs) possessing near-infrared fluorescence (NIRF), enhanced photothermal and photoacoustic (PA) performance, as “one-in-all” nanomedicines, are designed and obtained. Cu doping in amorphous Ag 2 S QDs causes red-shift of NIRF to the lowest tissue absorption wavelength in so called “first biowindow” (~820 nm) and improves photothermal conversion efficiency to 44.0% simultaneously. Density functional theory simulation results suggest the fluorescence red-shift and enhanced photothermal/photoacoustics properties can be attributed to the generation of intragap states introduced by Cu doping. The amorphous Ag 2-x Cu x S QDs exhibit high long-term biocompatibility. Under a single laser irradiation with relatively low power density, an effective tumor ablation induced by high photothermal effect of amorphous Ag 2-x Cu x S QDs is achieved in vivo. Simultaneously, the PTT process can be guided by high quality NIRF/PA dual-modal-imaging.

36 MATERIALS SCIENCE↗