Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic operation and stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Real-space observation of fluctuating antiferromagnetic domains

Magnetic domains play a fundamental role in physics of magnetism and its technological applications. Dynamics of antiferromagnetic domains is poorly understood, although antiferromagnets are expected to be extensively used in future electronic devices wherein it determines the stability and operational speed. Dynamics of antiferromagnets also features prominently in the studies of topological quantum matter. Real-space imaging of fluctuating antiferromagnetic domains is therefore highly desired but has never been demonstrated. We use coherent x-ray diffraction to obtain videos of fluctuating micrometer-scale antiferromagnetic domains in Ni 2 MnTeO 6 on time scales from 10 -1 to 10 3 s. In the collinear phase, thermally activated domain wall motion is observed in the vicinity of the Néel temperature. Unexpectedly, the fluctuations persist through the full range of the higher-temperature helical phase. These observations illustrate the high potential significance of the dynamic domain imaging in phase transition studies and in magnetic device research.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Chatter Stability of Machining Operations

Here, this paper reviews the dynamics of machining and chatter stability research since the first stability laws were introduced by Tlusty and Tobias in the 1950s. The paper aims to introduce the fundamentals of dynamic machining and chatter stability, as well as the state of the art and research challenges, to readers who are new to the area. First, the unified dynamic models of mode coupling and regenerative chatter are introduced. The chatter stability laws in both the frequency and time domains are presented. The dynamic models of intermittent cutting, such as milling, are presented and their stability solutions are derived by considering the time-periodic behavior. The complexities contributed by highly intermittent cutting, which leads to additional stability pockets, and the contribution of the tool's flank face to process damping are explained. The stability of parallel machining operations is explained. The design of variable pitch and serrated cutting tools to suppress chatter is presented. The paper concludes with current challenges in chatter stability of machining which remains to be the main obstacle in increasing the productivity and quality of manufactured parts.

42 ENGINEERING↗

Transient Stability Study of a Real-World Microgrid with 100% Renewables

This paper performs a transient stability study of a real-world microgrid that can operate with 100% renewables to better understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, an electromagnetic transient model of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid. It can also inform field deployment in terms of inverter control parameters and coordination as well as the expected performance of black start and unplanned islanding.

black start↗

Transient Stability Study of a Real-World Microgrid with 100% Renewables

This paper performs a transient stability study of a real-world microgrid that can operate with 100% renewables to better understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, an electromagnetic transient model of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid. It can also inform field deployment in terms of inverter control parameters and coordination as well as the expected performance of black start and unplanned islanding.

black start↗

Learning-Based Load Control to Support Resilient Networked Microgrid Operations

Microgrids have proven to be an effective option for increasing the resiliency of critical end-use loads during extreme events. Building on past operational experiences, some microgrid operators are examining the potential to network microgrids to further improve resiliency. However, the frequency deviations experienced on isolated microgrids during transient events, such as switching operations, step increases in load, and loss of generation, are significantly larger than those typically seen on bulk transmission systems. The larger frequency deviations can cause a loss of inverter-connected assets, resulting in a loss of power to critical end-use loads. This paper presents a method of mitigating the impact of transient events by engaging end-use loads using Grid-Friendly Appliance TM (GFA) controllers. An online, i.e., real-time, device-level algorithm is presented, which adjusts individual GFA controller frequency set-points based on the operational characteristics of each end-use load, and on the changing grid dynamic characteristics. The presented method improves the dynamic stability of the networked microgrid operations while minimizing the interruptions to end-use loads. The presented work is validated with dynamic simulations using a modified version of the IEEE 123-node test system with three microgrids, using the GridLAB-D TM simulation environment.

Radhakrishnan, Nikitha↗

Nano-Engineered Interfaces in Dual-Layer Electrodes for Protonic Ceramic Cells with Enhanced Stability and Kinetics

Enhancing interfacial stability and charge transfer in protonic ceramic cells (PCCs) remains a critical challenge, as structural degradation and interfacial resistance often compromise durability and efficiency. Here, we report a nanoengineered dual-layer oxygen electrode architecture designed to address these limitations by introducing a fine-grained nanoparticle interfacial contact layer beneath a porous catalytic backbone. The nanoscale powders, through enhanced sintering activity, densify into a robust interfacial layer that promotes strong chemical bonding, uniform adhesion, and continuous ionic/electronic pathways with the BCZYYb electrolyte. This hierarchical architecture mitigates delamination, redistributes mechanical stress, and establishes efficient charge and mass transport channels without relying on corrosive surface treatments. Electrochemical evaluation demonstrates that the dual-layer design markedly reduces interfacial polarization resistance and accelerates electrode kinetics. Compared to the single-layer counterpart, the architecture achieves a peel strength of 44.53 N/cm 2 , a 40% improvement in peak power density (0.96 W cm –2 at 600 °C), and a 130% enhancement in electrolysis current density (4.78 A cm –2 at 1.57 V). Faradaic efficiency remains as high as 88% under high steam concentrations, underscoring minimal charge loss during practical operation. Notably, the electrode retains stability across 450–600 °C and under transient voltage cycling, with impedance spectra confirming suppressed interfacial resistance growth over prolonged use. These results highlight nanoscale interface engineering as a powerful route to enhance both mechanical robustness and electrochemical kinetics in PCCs. The demonstrated scalability and durability of this architecture provide a versatile platform for advancing solid-state electrochemical systems, including reversible fuel cells and high-efficiency hydrogen production technologies.

Faradaic efficiency↗

Thin, Highly Selective Polymer Membrane Separators for Advanced Liquid Alkaline Water Electrolysis

Our team will develop novel, dense, polymer electrolyte separators based on polybenzimidazole (PBI) derivatives that will enable tuning of water/KOH uptake in mechanically robust films for advanced liquid alkaline water electrolysis (LAWE). These material advances will enable thinner separators with increased selectivity (hydroxide conductivity/hydrogen permeability), thereby enabling higher operating currents, increased dynamic operating high-temperature stability, and catalyst-coated membranes (zero-gap design advantages) in direct alignment with stated lab call goals.

HYDROGEN↗

Large-Signal Stability Improvement of Parallel Grid-Forming Inverter-Driven Black Start: Preprint

With the rapid increase of inverter-based resources in modern grids, advanced grid-forming (GFM) inverter capa- bilities, such as system restoration and operation under faults, are urgently needed to realize power electronics-dominant grids at scale. One such capability is inverter-driven black start using GFM inverters. This paper analyzes the ability of two recently proposed advanced GFM controls to help GFM inverters sustain system-wide, off-nominal conditions and remain synchronized until they can overcome the momentary overloading as more GFMs join the process without generator sequence coordination or communications and finally stabilize the grid. Through an extensive set of 1,200 full-order electromagnetic transient simu- lations, we evaluate the black-start process while employing the various GFM inverter controls. The results show that the GFM current limiter and primary control have a significant impact on the stability of the system during dynamic operating conditions and thus impact the success of inverter-driven system restoration.

current limit↗

Transient Stability Study of a Real-World Microgrid with 100% Renewables: Preprint

This paper performs a transient stability study of a real-world microgrid with 100% renewables to fully understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, the full-scale electromagnetic transient modeling of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid, which gives good references for the field deployment in terms of inverter configuration and coordination as well as the capabilities of black start and unplanned islanding.

100% renewable microgrid↗

Application of a temporal multiscale method for efficient simulation of degradation in PEM Water Electrolysis under dynamic operating conditions

Hydrogen is emerging as a vital energy carrier, driven by the need to reduce carbon emissions. Proton Electrolyte Membrane Water Electrolysis (PEMWE) enables hydrogen production under fluctuating renewable power conditions but requires improved understanding and stability of the anode catalyst layer under dynamic operating conditions, especially with low noble metal loadings. Long-term degradation experiments are both time-consuming and costly; therefore, a systematic, model-aided approach is essential. In the present work, a temporal multiscale method is applied to reduce the computational effort of simulating long-term degradation processes in PEMWE, with an exemplary focus on catalyst dissolution. A mechanistic model incorporating the oxygen evolution reaction, catalyst dissolution, and hydrogen permeation from the cathode to the anode was hypothesized and implemented. In this way, the local periodicity of transport and reaction processes in dynamic PEMWE operation, which influence the gradual degradation of the catalyst layer, is captured. The temporal multiscale method significantly reduces the computational effort of simulation, decreasing processing time from hours to mere minutes. This efficiency gain is attributed to the limited evolution of Slow-Scale variables during each period of time P of the Fast-Scale variables. Consequently, simulation is required only until local periodicity is achieved within each Slow-Scale time step. Hence, the fully resolved dynamic problem is decoupled into these two scales, employing a heterogeneous multiscale technique. The developed approach effectively accelerates parameter estimation and predictive simulations, supporting systematic modeling of PEMWE degradation under dynamic conditions.

08 HYDROGEN↗

Data-driven modeling and control of dynamical systems using Koopman and Perron-Frobenius operators

This dissertation studies the data-driven modeling and control problem of nonlinear systems by exploiting the linear operator theoretic framework involving Koopman and Perro-Frobenius operator. A systematic linear-operator based controller design procedure has been established, which can be used to solve a variety of nonlinear control problems, including feedback stabilization using control Lyapunov functions, optimal quadratic regulation using Koopman eigenfunctions and convex optimization formulation of optimal control problem using P-F and Koopman operator approximation. As the core of data-driven modeling, we first propose a new algorithm for the finite-dimensional approximation of the linear transfer Koopman and Perron-Frobenius operator from time-series data. We argue that the existing approach for the finite-dimensional approximation of these transfer operators such as Dynamic Mode Decomposition (DMD) and Extended Dynamic Mode Decomposition (EDMD) do not capture two important properties of these operators, namely positivity and Markov property. The algorithm we propose preserves these two properties. We call the proposed algorithm as naturally structured DMD (NSDMD) since it retains the inherent properties of these operators. Naturally structured DMD algorithm leads to a better approximation of the steady-state dynamics of the system regarding computing Koopman and Perron- Frobenius operator eigenfunctions and eigenvalues. However, preserving positivity property is critical for capturing the real transient dynamics of the system. This positivity property of the transfer operators and it's finite-dimensional approximation play an important role for controller and estimator design of nonlinear systems. To solve the feedback stabilization problem for nonlinear control systems, we tried to take advantage of the Koopman operator framework. The Koopman operator approach provides a linear representation for a nonlinear dynamical system and a bilinear representation for a nonlinear control system. The problem of feedback stabilization of a nonlinear control system is then transformed to the stabilization of a bilinear control system. We propose a control Lyapunov function (CLF)-based approach for the design of stabilizing feedback controllers for the bilinear system. The search for finding a CLF for the bilinear control system is formulated as a convex optimization problem. This leads to a schematic procedure for designing CLF-based stabilizing feedback controllers for the bilinear system and hence the original nonlinear system. Another advantage of the proposed controller design approach outlined in this dissertation is that it does not require explicit knowledge of system dynamics. In particular, the bilinear representation of a nonlinear control system in the Koopman eigenfunction space can be obtained from time-series data. Next, we study the optimal quadratic regulation problem for nonlinear systems. The linear operator theoretic framework involving the Koopman operator is used to lift the dynamics of nonlinear control system to an infinite-dimensional bilinear system. The optimal quadratic regulation problem for nonlinear system is formulated in terms of the finite-dimensional approximation of the bilinear system. A convex optimization-based approach is proposed for solving the quadratic regulator problem for bilinear system. We applied a variety of examples and compared the simulation results between our framework and conventional LQR control using linearized model. For more general optimal control problems, we provide a density-function based convex formulation for the optimal control problem of the nonlinear system. The convex formulation relies on the duality result in the stability theory of a dynamical system involving density function and Perron-Frobenius operator. The optimal control problem is formulated as an infinite-dimensional convex optimization program. The finite-dimensional approximation of the optimization problem relies on the recent advances made in the data-driven computation of the Koopman operator, which is dual to the Perron-Frobenius operator. Simulation results are presented to demonstrate the application of the developed framework.

Huang, Bowen↗

Machine Learning Solutions for a Stable Grid Recovery

Grid operating security studies are typically employed to establish operating boundaries, ensuring secure and stable operation for a range of operation under NERC guidelines. However, if these boundaries are severely violated, existing system security margins will be largely unknown, as would be a secure incremental dispatch path to higher security margins while continuing to serve load. As an alternative to the use of complex optimizations over dynamic conditions, this work employs the use of machine learning to identify a sequence of secure state transitions which place the grid in a higher degree of operating security with greater static and dynamic stability margins. Several reinforcement learning solution methods were developed using deep learning neural networks, including Deep Q-learning, Mu-Zero, and the continuous algorithms Proximal Reinforcement Learning, and Advantage Actor Critic Learning. The work is demonstrated on a power grid with three control dimensions but can be scaled in size and dimensionality, which is the subject of ongoing research.

24 POWER TRANSMISSION AND DISTRIBUTION↗

State-of-the-art of data collection, analytics, and future needs of transmission utilities worldwide to account for the continuous growth of sensing data

Nowadays, transmission system operators require higher degree of observability in real-time to gain situational awareness and improve the decision-making process to guarantee a safe and reliable operation. Digitalization of energy systems allows utilities to monitor the system dynamic performance in real-time at fast time scales. The use of such technologies has unlocked new opportunities to introduce new data driven algorithms for improving the stability assessment and control of the system. Motivated by these challenges, a group of experts have worked together to highlight and establish a baseline set of these common concerns, which can be used as motivation to propose innovative analytics and data-driven solutions. In this document, the results of a survey on 10 transmission system operators around the world are presented and it aims to understand the current practices of the participating companies, in terms of data acquisition, handling, storage, modelling and analytics. The overall objective of this document is to capture the actual needs from the interviewed utilities, thereby laying the groundwork for setting valid assumptions for the development of advanced algorithms in this field.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchronous Machine Governor Upgrade

Conventional generation sources play a critical role in the stability and reliability of the electrical grid, particularly as we transition towards more renewable energy sources. To understand and accurately emulate their behavior for optimizing grid operations and ensuring seamless integration with renewable technologies, it is essential to better emulate the grid- and plant-level impacts of conventional generation sources, such as natural gas (NG) driven heat recovery steam generators (HRSGs) and combustion turbines (CTs). Therefore, a governor model is developed in a programmable logic controller (PLC) to investigate the performance of the conventional generator under various dynamic operating conditions and to identify the impact on grid stability in a controlled environment. The governor model aims to enable the hardware-in-the-loop (HIL) based emulation of these conventional generation sources using the existing 2 MVA synchronous machine/generator that is driven by a flexible 2.5 MW variable speed drive. This setup will allow us to replicate the dynamic characteristics and response behaviors of NG-driven HRSGs and CTs. The controls for the emulated conventional plants follow the industry standard and are adjustable, ensuring they accurately reflect the operational capabilities and limitations of real-world systems. These controls include load-following capabilities, ramp rates, startup and shutdown sequences, and emissions characteristics. By incorporating these adjustable controls, we aim to capture the nuanced impacts of conventional generation, such as their ability to provide ancillary services like frequency regulation, voltage support, and spinning reserve. In this report, we simulate two types of dynamic operations: grid-connected and islanding. For each dynamic operation, representative starting sequences are tested, including turbine purge, ignition, speed ramping up, generator excitation and synchronizing, and breaker close. The HIL based tests provides insights for field deployment, specifically the high-fidelity governor model provides results to predict the potential stability and reliability risk and suggest possible integration measures (e.g., generation and load balancing, tuning of governor control parameters). Ultimately, this enhanced emulation capability will be integrated into our Advanced Research on Integrated Energy Systems (ARIES), enabling us to conduct comprehensive studies on the interactions between conventional and renewable energy sources. By better understanding these interactions, we can develop strategies to optimize the overall performance and reliability of the grid. This will support the deployment of advanced grid management techniques, such as demand response, grid-forming inverters, and energy storage systems. The main contributions are summarized as follows: (1) This report introduces a PLC-based governor model for gas turbines. This model accurately simulates the dynamic behavior of conventional generation sources under various operational scenarios; (2) The model is integrated with an HIL testbed that includes a 2.5 MW variable speed drive and a 2 MVA synchronous machine. This setup enables realistic, real-time emulation of conventional power plants, particularly NG driven HRSGs and CTs; (3) The developed model is adaptable to various gas turbine configurations and allows for precise control over parameters such as MW ramp rates. This flexibility makes it a valuable tool for future research and industry collaboration; and (4) By incorporating the model into the National Renewable Energy Laboratory's Advanced Research on Integrated Energy Systems, the report lays the groundwork for future studies on interactions between conventional and renewable energy sources, enhancing the ability to develop advanced grid management strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A hierarchical gray-box dynamic modeling methodology for direct-expansion cooling systems to support control stability analysis; Méthodologie de modélisation dynamique hiérarchique de type boîte grise pour les systèmes de refroidissement à détente directe afin de soutenir l'analyse de stabilité de la commande

In this paper, a gray-box dynamic modeling approach for direct-expansion cooling systems is presented. The overall approach incorporates a multi-stage training procedure that consists of 1) identification of component sub-models from quasi-steady-state performance data, 2) system model integration with estimation of refrigerant charge and 3) fine tuning of thermal capacitances of the evaporator and condenser to capture the system dynamic responses. Compared to traditional physics-based models, the proposed modeling approach has advantages including reduced engineering efforts in the model development phase, improved computational efficiency and enhanced prediction accuracy. The modeling method was validated using a 3-ton variable-speed heat pump and proved to be capable of accurately predicting the system transient behaviors over a wide range of operating conditions. The established dynamic model was then applied for control stability analysis, with a specific goal of determining a proper control execution time step. The case study results showed that the stable control execution time step could change significantly, from 3 sec to 19 sec, as the operating conditions and control settings vary, and a proper selection of the execution time step is critical to ensure stable and reliable operations.

42 ENGINEERING↗

In Situ Nanoscale Dynamics Imaging in a Proton‐Conducting Solid Oxide for Protonic Ceramic Fuel Cells

Abstract Hydrogen fuel cells and electrolyzers operating below 600 °C, ideally below 400 °C, are essential components in the clean energy transition. Yttrium‐doped barium zirconate BaZr 0.8 Y 0.2 O 3‐d (BZY) has attracted a lot of attention as a proton‐conducting solid oxide for electrochemical devices due to its high chemical stability and proton conductivity in the desired temperature range. Grain interfaces and topological defects modulate bulk proton conductivity and hydration, especially at low temperatures. Therefore, understanding the nanoscale crystal structure dynamics in situ is crucial to achieving high proton transport, material stability, and extending the operating range of proton‐conducting solid oxides. Here, Bragg coherent X‐ray diffractive imaging is applied to investigate in situ and in 3D nanoscale dynamics in BZY during hydration over 40 h at 200 °C, in the low‐temperature range. An unexpected activity of topological defects and subsequent cracking is found on a nanoscale covered by the macroscale stability. The rearrangements in structure correlate with emergent regions of different lattice constants, suggesting heterogeneous hydration. The results highlight the extent and impact of nanoscale processes in proton‐conducting solid oxides, informing future development of low‐temperature protonic ceramic electrochemical cells.

25 ENERGY STORAGE↗

Sintering protonic zirconate cells with enhanced electrolysis stability and Faradaic efficiency

The emerging applications of steam electrolysis and electrochemical synthesis at 300–600 °C set stringent requirements on the stability of protonic ceramic cells, which cannot be met by Ce-rich electrolytes. A promising candidate is Ce-free BaZr 0.8 Y 0.2 O 3–δ , but its usage has long been hindered due to the high sintering temperatures required for protonic devices. Here we resolved the issue through a co-sintering process, in which the shrinkage stress of a readily sinterable support layer helps to densify the pure BaZr 0.8 Y 0.2 O 3–δ electrolyte membrane at low temperatures. This approach eliminates Ce and harmful sintering aids in the dense zirconate electrolyte membrane, thereby enhancing the Faradaic efficiency and electrochemical stability, especially under harsh operating conditions. Here, the protonic zirconate cells have exceptional performance and demonstrate stable high-steam pressure electrolysis up to 0.7 atm steam pressure, –2 A cm –2 current density and over 800 h of dynamic operation at 600 °C. Our processing breakthrough enables stabilized protonic cells for demanding applications in future energy infrastructure.

25 ENERGY STORAGE↗

Voltage cycling as a dynamic operation mode for high temperature electrolysis solid oxide cells

Solid Oxide Electrolysis Cells (SOECs) have emerged as a promising technology for the efficient production of H2 via high-temperature electrolysis. However, power input from dynamic energy sources remains a significant challenge for their long-term stability. It is important to analyze the tolerance of cells under dynamic operation conditions. This study focuses on evaluating the impact of voltage cycling on the performance and durability of electrode-supported SOECs. We explore the operational limits and degradation mechanisms of SOECs subjected to various voltage conditions and find that the cells have high tolerance for dynamic voltage. Voltage cycling between 1.3 V and 1.5 V for 9000 cycles does not damage the cell. Conversely, cycling to higher voltages (≥1.7 V) results in accelerated degradation. Advanced characterization is used to screen for various degradation modes post operation. Within the oxygen electrode, XRD and STEM EDS find compositional and phase evolution in all voltage cycled samples including increased decomposition of the air electrode resulting in cation migration. Microstructural analysis of the fuel electrode from nano-CT data shows minimal change throughout the sample set and no evidence of Ni migration, indicating the fuel electrode is stable and not impacted by cycling to higher voltages within the timeframe studied.

Zhu, Zhikuan↗