Search NASA⌕ Search

SEARCH · Search NASA

Results for “effective area”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Data release for A search for extremely-high-energy neutrinos and first constraints on the ultra-high-energy cosmic-ray proton fraction with IceCube

<h1 id="summary">Summary</h1> <p>Title: Data Release for A search for extremely-high-energy neutrinos and first constraints on the ultra-high-energy cosmic-ray proton fraction with IceCube</p> <p>The IceCube observatory analyzed 12.6 years of data in search of extremely-high-energy (EHE) neutrinos above 5 PeV. The resultant limit of the search (Fig 1), and the effective area of the event selection (Fig 7), are provided in this data release.</p> <h1 id="contents">Contents</h1> <ul> <li><p>README file: this file</p> </li> <li><p><code>differential_limit_and_sensitivity.csv</code>: a comma separated value file, giving the observed experimental differential limit, and sensitivity, of the search as a function of neutrino energy. This is the content of Fig 1 in the paper. The first column is the neutrino energy in GeV. The second column is the limit in units of GeV/cm2/s/sr. The third column is the sensitivity in units of GeV/cm2/s/sr.</p> </li> <li><p><code>effective_area.csv</code>: a comma separated value file, giving the effective area of the search as a function of energy. This is the content of Fig 7 in the paper. The first column is the neutrino energy in GeV. The second column is the total effective area of the search, summed across neutrino flavors, and averaged across neutrinos and antineutrinos, in meters-squared. The third column is the effective area of the search for the average of electron neutrino and electron antineutrinos in units of meters-squared. The fourth column is the same as the third, but for muon-flavor neutrinos. The fifth column is the same as the third and fourth, but for tau-flavor neutrinos.</p> </li> <li><p><code>demo.py</code>: a short python script to demonstrate how to read the files. Run like <code>python demo.py</code>. A standard base python installation is sufficient, as the only dependencies are numpy and matplotlib.</p> </li> </ul> <h1 id="contacts">Contacts</h1> <p>For any questions about this data release, please write to analysis@icecube.wisc.edu</p>

Astronomy and Astrophysics↗

D-Egg: a dual PMT optical module for IceCube

The D-Egg, an acronym for "Dual optical sensors in an Ellipsoid Glass for Gen2," is one of the optical modules designed for future extensions of the IceCube experiment at the South Pole. The D-Egg has an elongated-sphere shape to maximize the photon-sensitive effective area while maintaining a narrow diameter to reduce the cost and the time needed for drilling of the deployment holes in the glacial ice for the optical modules at depths up to 2700 m. The D-Egg design is utilized for the IceCube Upgrade, the next stage of the IceCube project also known as IceCube-Gen2 Phase 1, where nearly half of the optical sensors to be deployed are D-Eggs. With two 8-inch high-quantum efficiency photomultiplier tubes (PMTs) per module, D-Eggs offer an increased effective area while retaining the successful design of the IceCube digital optical module (DOM). The convolution of the wavelength-dependent effective area and the Cherenkov emission spectrum provides an effective photodetection sensitivity that is 2.8 times larger than that of IceCube DOMs. The signal of each of the two PMTs is digitized using ultra-low-power 14-bit analog-to-digital converters with a sampling frequency of 240 MSPS, enabling a flexible event triggering, as well as seamless and lossless event recording of single-photon signals to multi-photons exceeding 200 photoelectrons within 10 ns. Mass production of D-Eggs has been completed, with 277 out of the 310 D-Eggs produced to be used in the IceCube Upgrade. In this paper, we report the design of the D-Eggs, as well as the sensitivity and the single to multi-photon detection performance of mass-produced D-Eggs measured in a laboratory using the built-in data acquisition system in each D-Egg optical sensor module.

47 OTHER INSTRUMENTATION↗

Understanding resistance oscillation in the CsV 3 Sb 5 superconductor

A recent demonstration of the periodic oscillation of resistance in the thin film of the CsV 3 ⁢Sb 5 superconductor with a hole in the film suggests that charge-4⁢ e and charge-6⁢⁢ e Cooper pairs may have condensed in this compound. While exciting, such interpretation calls for a precise determination of the effective area for the passage of Cooper pairs from one end of the lead to the other. Unlike the traditional Little-Parks effect where the rim around the hole is thin, the effective hole area is not obviously defined for the “thick-rim geometry” adopted in the experiment. Here, we note that the experiment was conducted in a regime where the superconductivity is strongly fluctuating, which motivates an analysis based on the spacetime formulation of the time-dependent Ginzburg-Landau theory. Further, we argue that under appropriate conditions, the optimal semiclassical path is not the geometrically shortest one, but the one that moves along the edge of the hole and takes advantage of the reduced fluctuations at the boundary of the hole. The condition for the crossover from the geometrically shortest path to the path that sticks to the wall is clarified. In such a scenario, the geometric area of the hole indeed emerges as the effective area for the flux, providing a theoretical justification to the interpretation given by J. Ge et al. (arXiv:2201.10352). The conclusion of our analysis may have implications for similar experiments in other superconductors where the geometry of the device is not obviously that of the Little-Parks experiment employing the thin wall, but of the thick-rim type such as used in the experiment.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effective Selective Area Doping for GaN Vertical Power Transistors Enabled by Innovative Materials Engineering

GaN vertical power transistors have emerged as promising candidates for future high efficiency high power electronic applications, with the potential to outperform conventional GaN lateral power devices in terms of power, breakdown, and avalanche characteristics. However, the development of current GaN vertical power transistors is seriously hindered by the poor materials performance of selective area doped p-n junctions. A mechanistic understanding of these fundamental materials issues is essential in order to achieve high performance selective area doped p-n junctions and consequently to advance the GaN vertical power transistor technology. To address this challenge, we carried out a comprehensive research program that advance fundamental knowledge in the selective area doping for GaN materials, and which will lead to the development of high performance GaN vertical power transistors. First, we developed innovative fabrication processes, including novel surface etching, surface passivation, and metalorganic chemical vapor deposition (MOCVD) growth, which provided enhanced opportunities for solving the unique challenges of selective area doping in GaN materials. Second, we performed a fundamental materials study using powerful characterization methods including transmission electron microscopy (TEM), ultraviolet (UV-), x-ray and angle-resolved photoelectron spectroscopy (UPS/XPS/ARPES), electron holography, and cathodoluminescence (CL); Third, we investigated several related issues, including Mg incorporation, polarization effects in carrier transport, and non-ideal material effects, which have rarely been explored so far. At the end of this project, we successfully demonstrated (1) fundamental understanding of selective area etching, regrowth, and doping of GaN, and associated knowledge on defects, interface, and breakdown properties. (2) Effective etch and regrowth processing recipes to achieve etch/regrowth GaN p-n diodes with very low leakage of 3.5 nA at 600 V, which meets the ARPA-E target. (2) High performance vertical GaN p-n didoes and vertical junction termination extension (JTE) devices with breakdown voltage of ~ 2 kV, and breakdown electric field of ~ 3.5 MV/cm, which are close to the performance limit of GaN. The successful outcome has resulted in new fundamental understandings in the selective area doping and regrowth process for GaN, which will lead to groundbreaking GaN vertical transistors for high performance next generation power electronics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rotational flexural strength of cylindrical brittle specimens

Conventional static flexural strength testing of brittle cylindrical rods only subjects a small fraction of the entire specimen's area or volume to the maximum tensile stress. Thus, a nonconservative measured strength likely results since most flaws on the surface or in the bulk are not subjected to a sufficiently high tensile stress that can cause fracture. Here, to mitigate this, a rotational flexural tester and corresponding test method were developed whereby rotation and monotonically increasing three-point flexure were superimposed to investigate fracture response of solid glass cylinders. This combination of rotation and flexure subjects more area and volume of a cylindrical test specimen to tensile stress than a standard static (nonrotating) flexural test. As anticipated, failure stresses were lower for the rotational flexural test. Expressions for effective area and volume are provided for rotating solid rods and tubes subjected to three-point, four-point, uniform, and uniformly distributed load bending configurations.

36 MATERIALS SCIENCE↗

Evaluation of a Variable-Aperture Full-Ring SPECT System using Large-Area Pixelated CZT Modules: A Simulation Study for Brain SPECT Applications

Single photon emission computed tomography (SPECT) scanner using cadmium zinc telluride (CZT) offers improved imaging capability over conventional NaI (Tl)-based SPECT scanner. We aim to demonstrate a full-ring SPECT system design with eight large-area CZT detectors that can be used for a broad spectrum of SPECT radiopharmaceuticals and provides higher sensitivity and better spatial resolution than those of conventional NaI (Tl)-based gamma cameras. A newly-designed full-ring SPECT system is composed of 8 large-area CZT cameras (128 mm × 179.2 mm effective area) that can be independently swiveled around their own axes of rotation independently and can have radial motion for varying aperture sizes that can be adapted to different sizes of imaging volume. Extended projection data were generated by conjoining projections of two adjacent detectors to overcome the limited field-of-view (FOV) by each CZT camera. Using Monte Carlo simulations, we evaluated this new system design with digital phantoms including a Derenzo hot-rod phantom and a Zubal brain phantom. Comparison of performance metrics such as spatial resolution, sensitivity, contrast-to-noise ratio (CNR), and contrast-recovery ratio were made between our design and a conventional SPECT scanner. The proposed scanner could result in up to about 3 times faster in acquisition time over conventional scan time at same acquisition time per step. The spatial resolution of our proposed scanner was similar or better to that of the conventional scanner, and there was significant performance improvement over the conventional scanner particularly in sensitivity (approximately 4 times). Overall, we successfully reconstructed the phantom image for both 99 mTc-based perfusion and 123 I-based dopamine transporter (DaT) brain studies simulated for our new design. In particular, the striatal/background contrast-recovery ratio in 3-to-1 reference ratio was over the 0.8 for the 123 I-based DaT study. In conclusion, we demonstrated the potential of our new full-ring CZT SPECT design, showing improved performance metrics such as improved system sensitivity and CNR while maintaining other important imaging parameters such as spatial resolution.

36 MATERIALS SCIENCE↗

Methodology For Determining The Effective Aircraft Impact Area For Irregularly Shaped Facilities

This report presents a computational methodology for determining the effective aircraft impact area for irregularly shaped facilities, extending the approach in Department of Energy (DOE) Standard 3014 by decomposing “critical areas” into multiple rectangular nodes rather than relying on a single bounding cuboid. This method reduces unnecessary conservatism that can arise when non-critical space is enveloped by a single footprint. The facility’s critical areas are partitioned into nodes of constant height, a baseline aircraft impact trajectory is established, and the facility perspective is rotated to accommodate arbitrary heading angles. For each node, analytic expressions are provided to construct the node-specific effective impact polygon that accounts for skid distance, structural footprint, fly-in (shadow) region driven by building height and descent angle, and wingspan offsets capturing wing-only strikes.

42 ENGINEERING↗

Environmental Degradation in Advanced Reactor Environments

The Advanced Materials and Manufacturing Technologies (AMMT) program operating under the Department of Energy Office of Nuclear Energy is accelerating the qualification and deployment of additively manufactured materials in advanced reactor environments. Laser powder bed fusion (LPBF) has emerged as a promising additive manufacturing technique to fabricate complex components with the potential of tailored material properties. In the nuclear industry, metal additive manufacturing can offer numerous advantages, such as reduced lead times, streamlined quality assurance, and cost-effective low-volume production of new and replacement components with conventional or novel materials and geometries. The rapid and effective qualification of the effect of processing variability on the performance and degradation of additively manufactured materials is essential for the deployment of these components into advanced reactor environments. This talk presents an overview of the Environmental Effects area activities within AMMT. AMMT is performing irradiation and corrosion testing of several materials built by LPBF, including 316L and 316H stainless steels. Our irradiation efforts encompass neutron irradiation testing and ion irradiation testing to provide a robust technical basis for understanding the effect of process variability on materials degradation. We develop focused irradiation test plans that align well with risk-informed and technologically inclusive approaches to licensing. We will also discuss our plans and specific concerns for corrosion testing additively manufactured material, with a primary focus on molten salt and liquid sodium environments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Searching for axionlike particles from core-collapse supernovae with Fermi LAT’s low-energy technique

Light axionlike particles (ALPs) are expected to be abundantly produced in core-collapse supernovae (CCSNe), resulting in a ~ 10 -second long burst of ALPs. These particles subsequently undergo conversion into gamma rays in external magnetic fields to produce a long gamma-ray burst (GRB) with a characteristic spectrum peaking in the 30–100-MeV energy range. At the same time, CCSNe are invoked as progenitors of ordinary long GRBs, rendering it relevant to conduct a comprehensive search for ALP spectral signatures using the observations of long GRBs with the Fermi Large Area Telescope (LAT). We perform a data-driven sensitivity analysis to determine CCSN distances for which a detection of an ALP signal is possible with the LAT’s low-energy technique which, in contrast to the standard LAT analysis, allows for a a larger effective area for energies down to 30 MeV. Assuming an ALP mass m a ≲ 10 - 10 eV and ALP-photon coupling g a γ = 5.3 × 10 - 12 GeV - 1 , values considered and deduced in ALP searches from SN1987A, we find that the distance limit ranges from ~ 0.5 to ~ 10 Mpc , depending on the sky location and the CCSN progenitor mass. Furthermore, we select a candidate sample of 24 GRBs and carry out a model comparison analysis in which we consider different GRB spectral models with and without an ALP signal component. We find that the inclusion of an ALP contribution does not result in any statistically significant improvement of the fits to the data. Finally, we discuss the statistical method used in our analysis and the underlying physical assumptions, the feasibility of setting upper limits on the ALP-photon coupling, and give an outlook on future telescopes in the context of ALP searches.

79 ASTRONOMY AND ASTROPHYSICS↗

Understanding the effect of specimen size on the properties of fine-grain isotropic nuclear graphite for irradiation studies: Mechanical properties

Programs at Oak Ridge National Laboratory are investigating the effects of neutron irradiation in the High Flux Isotope Reactor (HFIR) on properties of fine-grain isotropic nuclear graphites. Specimens were irradiated in the HFIR flux trap, which requires using specimens that are smaller than the sizes recommended by ASTM standards. Here, this work has investigated whether subsized specimens can be used to reliably predict strength behavior. The results show that (1) tensile strength was loosely coupled to specimen volume, (2) the compression specimens had a slightly higher strength for larger volumes, (3) the uniaxial flexural strength was nearly independent of specimen effective area for one orientation whereas the other orientation showed a slight strength–size scaling Weibull behavior, and (4) equibiaxial flexural strength followed traditional strength–size scaling Weibull behavior. These results suggest that fine-grain graphite is more similar to ceramics than to medium- and large-grained graphite with respect to both the strength-limiting flaws (Griffith theory) and the effect of machining on the strength behavior. This work shows that using specimens that are smaller than ASTM recommendations are suitable for investigating the strength changes caused by neutron irradiation because the primary interest is the relative change in the strength distribution parameters rather than their absolute values.

36 MATERIALS SCIENCE↗

Development of a low-pressure Multi-Mesh THGEM detector for fission experiments at FRIB

Abstract A small-area imaging detector prototype for position measurement of fission fragments produced in low energy heavy-ion reactions is presented in this study. The detector readout is equipped with a 2-dimensional, position-sensitive gaseous avalanche readout based on the novel Multi-Mesh Thick-GEM (MM-THGEM), and is coupled to a delay-line board for particle localization. The prototype has an effective area of 10 × 10 cm 2 and is operated in isobutane at low pressure (7–10 Torr). We present and discuss a series of systematic evaluation tests performed by irradiating the detector with α-particles and fission fragments emitted by small-rate sources ( 241 Am, 249 Cf and 252 Cf). Position and time resolutions of about 0.42 mm and 1 ns were achieved, respectively. This work serves as a benchmark for the development of a large-scale array of detectors for experiments with fission and fission-like reaction products at the Facility for Rare Isotope Beams (FRIB).

Instruments & Instrumentation↗

Brighter-fatter Effect in Near-infrared Detectors—III. Fourier-domain Treatment of Flat Field Correlations and Application to WFIRST

Weak gravitational lensing has emerged as a leading probe of the growth of cosmic structure. However, the shear signal is very small and accurate measurement depends critically on our ability to understand how non-ideal instrumental effects affect astronomical images. The Wide-Field Infrared Survey Telescope (WFIRST) will fly a focal plane containing 18 Teledyne H4RG-10 near-infrared detector arrays, which present different instrument calibration challenges from previous weak lensing observations. Previous work [Paper I: Hirata & Choi, PASP, 132, 014501 (2020); and Paper II: Choi & Hirata, PASP, 132, 014502 (2020)] has shown that correlation functions of flat field images, including cross-correlations between different time slices that are enabled by the non-destructive read capability of the infrared detectors, are effective tools for disentangling linear and nonlinear inter-pixel capacitance (IPC) and the brighter-fatter effect (BFE). Here we present a Fourier-domain treatment of the flat field correlations, which allows us to expand the previous formalism to all orders in IPC, BFE, and classical nonlinearity. We show that biases in simulated flat field analyses in Paper I are greatly reduced through the use of this formalism. We then apply this updated formalism to flat field data from three WFIRST flight candidate detectors, and explore the robustness to variations in the analysis. We find that the BFE is present in all three detectors, and that its contribution to the flat field correlations dominates over the nonlinear IPC, in accordance with the results from Paper II on a development detector. The magnitude of the BFE is such that the effective area of a pixel is increased by (3.54 ± 0.03) × 10 -7 for every electron deposited in a neighboring pixel (sensor chip assembly [SCA] 20829, statistical error, not IPC-deconvolved). We compare IPC maps from flat field autocorrelation measurements to those obtained from the single pixel reset method and find a median difference of 0.113% for SCA 20829. After further diagnosis of this difference, we ascribe it largely to an additional source of cross-talk, the vertical trailing pixel effect, and recommend further work to develop a model for this effect. These results represent a significant step toward calibration of the non-ideal effects in WFIRST detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

Primordial non-Gaussianity from the completed SDSS-IV extended Baryon Oscillation Spectroscopic Survey – I: Catalogue preparation and systematic mitigation

ABSTRACT We investigate the large-scale clustering of the final spectroscopic sample of quasars from the recently completed extended Baryon Oscillation Spectroscopic Survey (eBOSS). The sample contains 343 708 objects in the redshift range 0.8 < z < 2.2 and 72 667 objects with redshifts 2.2 < z < 3.5, covering an effective area of $4699\, {\rm deg}^{2}$. We develop a neural network-based approach to mitigate spurious fluctuations in the density field caused by spatial variations in the quality of the imaging data used to select targets for follow-up spectroscopy. Simulations are used with the same angular and radial distributions as the real data to estimate covariance matrices, perform error analyses, and assess residual systematic uncertainties. We measure the mean density contrast and cross-correlations of the eBOSS quasars against maps of potential sources of imaging systematics to address algorithm effectiveness, finding that the neural network-based approach outperforms standard linear regression. Stellar density is one of the most important sources of spurious fluctuations, and a new template constructed using data from the Gaia spacecraft provides the best match to the observed quasar clustering. The end-product from this work is a new value-added quasar catalogue with the improved weights to correct for non-linear imaging systematic effects, which will be made public. Our quasar catalogue is used to measure the local-type primordial non-Gaussianity in a companion paper.

79 ASTRONOMY AND ASTROPHYSICS↗

CTA and SWGO can discover Higgsino dark matter annihilation

Thermal Higgsino dark matter (DM), with a mass near 1.1 TeV, is one of the most well-motivated and untested DM candidates. Leveraging recent hydrodynamic cosmological simulations that give DM density profiles in Milky Way analog galaxies we show that the linelike gamma-ray signal predicted from Higgsino annihilation in the Galactic Center could be detected at high significance with the upcoming Cherenkov Telescope Array (CTA) and Southern Wide-field Gamma-ray Observatory (SWGO) for all but the most pessimistic DM profiles. We perform the most sensitive search to-date for the linelike signal using 15 years of data from the Fermi Large Area Telescope, coming within an order one factor of the necessary sensitivity to detect the Higgsino for some Milky Way analog DM density profiles. We show that H.E.S.S. has subleading sensitivity relative to Fermi for the Higgsino at present. In contrast, we analyze H.E.S.S. inner Galaxy data for the thermal wino model with a mass near 2.8 TeV; we find no evidence for a DM signal and exclude the wino by over a factor of two in cross section for all DM profiles considered. In the process, we identify and attempt to correct what appears to be an inconsistency in previous H.E.S.S. inner Galaxy analyses for DM annihilation related to the analysis effective area, which may weaken the DM cross-section sensitivity claimed in those works by around an order of magnitude.

79 ASTRONOMY AND ASTROPHYSICS↗

An ultra-compact x-ray free-electron laser

In the field of beam physics, two frontier topics have taken center stage due to their potential to enable new approaches to discovery in a wide swath of science. These areas are: advanced, high gradient acceleration techniques, and x-ray free electron lasers (XFELs). Further, there is intense interest in the marriage of these two fields, with the goal of producing a very compact XFEL. In this context, recent advances in high gradient radio-frequency cryogenic copper structure research have opened the door to the use of surface electric fields between 250 and 500 MV m -1 . Such an approach is foreseen to enable a new generation of photoinjectors with six-dimensional beam brightness beyond the current state-of-the-art by well over an order of magnitude. This advance is an essential ingredient enabling an ultra-compact XFEL (UC-XFEL). In addition, one may accelerate these bright beams to GeV scale in less than 10 m. Such an injector, when combined with inverse free electron laser-based bunching techniques can produce multi-kA beams with unprecedented beam quality, quantified by 50 nm-rad normalized emittances. The emittance, we note, is the effective area in transverse phase space (x, p x /m e c) or (y, p y /m e c) occupied by the beam distribution, and it is relevant to achievable beam sizes as well as setting a limit on FEL wavelength. These beams, when injected into innovative, short-period (1–10 mm) undulators uniquely enable UC-XFELs having footprints consistent with university-scale laboratories. We describe the architecture and predicted performance of this novel light source, which promises photon production per pulse of a few percent of existing XFEL sources. We review implementation issues including collective beam effects, compact x-ray optics systems, and other relevant technical challenges. To illustrate the potential of such a light source to fundamentally change the current paradigm of XFELs with their limited access, we examine possible applications in biology, chemistry, materials, atomic physics, industry, and medicine—including the imaging of virus particles—which may profit from this new model of performing XFEL science.

47 OTHER INSTRUMENTATION↗

Superconducting contact and quantum interference between two-dimensional van der Waals and three-dimensional conventional superconductors

Atomically thin two-dimensional (2D) transition-metal dichalcogenide (TMD) superconductors enable uniform, flat, and clean van der Waals tunneling interfaces, motivating their integration into conventional superconducting circuits. However, fully superconducting contact must be made between the 2D material and three-dimensional (3D) superconductors to employ the standard microwave drive and readout of qubits in such circuits. We present a method for creating zero-resistance contacts between 2D NbSe 2 and 3D aluminum that behave as Josephson junctions (JJs) with large effective areas compared to 3D-3D JJs. The devices formed from 2D TMD superconductors are strongly influenced by the geometry of the flakes themselves as well as the placement of the contacts to bulk 3D superconducting leads. We present a model for the supercurrent flow in a 2D-3D superconducting structure by a numerical solution of the Ginzburg-Landau equations and find good agreement with experiment. Finally, these results demonstrate a crucial step towards a new generation of hybrid superconducting quantum circuits.

36 MATERIALS SCIENCE↗

Simulation studies of a full-ring, CZT SPECT system for whole-body imaging of 99m Tc and 177 Lu

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. With the goal of filling this technological gap, we have designed a cadmium zinc telluride (CZT) full-ring SPECT scanner instrumented with a broad-energy tungsten collimator. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT does not rely on the dual- and the triple-head rotational SPECT standard paradigm, enabling a larger effective area in each scan to increase the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized phantoms filled with 99m Tc and 177 Lu. Our SPECT design can resolve 7.9 mm rods for 99m Tc (140 keV) and 9.5 mm for 177 Lu (208 keV) in a hot-rod Derenzo phantom with a 3-min exposure and reach an image contrast of 78% for 99m Tc and 57% for 177 Lu using the NEMA IQ phantom with a 6-min exposure. Our modified scatter correction shows an improved contrast-recovery ratio compared to a standard correction. In this paper, we demonstrate the good performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99m Tc imaging of brain perfusion and 123 I imaging of dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design provides similar IQ and contrast to the commercial full-ring SPECT VERITON for 99m Tc. Regarding 177 Lu imaging of the 208 keV emissions, our design provides similar contrast to that of other state-of-the-art SPECTs with a significant reduction in exposure. In conclusion, the high sensitivity and extended energy range up to 250 keV makes our SPECT design a promising alternative for clinical imaging and theranostics of emerging radionuclides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗