Search NASA⌕ Search

SEARCH · Search NASA

Results for “electret”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

COVID-19 global pandemic planning: Performance and electret charge of N95 respirators after recommended decontamination methods

Shortages of N95 respirators for use by medical personnel have driven consideration of novel conservation strategies, including decontamination for reuse and extended use. Decontamination methods listed as promising by the Centers for Disease Control and Prevention (CDC) (vaporous hydrogen peroxide (VHP), wet heat, ultraviolet irradiation (UVI)) and several methods considered for low resource environments (bleach, isopropyl alcohol and detergent/soap) were studied for two commonly used surgical N95 respirators (3M™ 1860 and 1870+ Aura™). Although N95 filtration performance depends on the electrostatically charged electret filtration layer, the impact of decontamination on this layer is largely unexplored. As such, respirator performance following decontamination was assessed based on the fit, filtration efficiency, and pressure drop, along with the relationship between (1) surface charge of the electret layer, and (2) elastic properties of the straps. Decontamination with VHP, wet heat, UVI, and bleach did not degrade fit and filtration performance or electret charge. Isopropyl alcohol and soap significantly degraded fit, filtration performance, and electret charge. Pressure drop across the respirators was unchanged. Modest degradation of N95 strap elasticity was observed in mechanical fatigue testing, a model for repeated donnings and doffings. CDC recommended decontamination methods including VHP, wet heat, and UV light did not degrade N95 respirator fit or filtration performance in these tests. Extended use of N95 respirators may degrade strap elasticity, but a loss of face seal integrity should be apparent during user seal checks. NIOSH recommends performing user seal checks after every donning to detect loss of appropriate fit. Decontamination methods which degrade electret charge such as alcohols or detergents should not be used on N95 respirators. The loss of N95 performance due to electret degradation would not be apparent to a respirator user or evident during a negative pressure user seal check.

60 APPLIED LIFE SCIENCES↗

Electrets used in measuring rocket exhaust effuents from a Space Shuttle model

The study evaluates the use of electrets as a new contamination-detecting device designed to assess the chemical composition of rocket effluents. Evaluation of electret effectiveness revealed that electrets have multipollutant-measuring capability, simplicity of deployment and rapidity of assessment. Advantages of electrets are small size, light weight and cost-effectiveness. It is shown that electrets compare favorably with other HCl measuring devices. In particular, the summary of the measured data from electrets and HCl detectors is within the limits of computed HCl concentrations from the NASA/MSFC multilayer diffusion model.

Susko, M.↗

Research in the use of electrets in measuring effluents from rocket exhaust of the space shuttle (6.4 percent scaled model) and Viking 1 launch

Electrets used to detect the chemical composition of rocket exhaust effluents were investigated. The effectiveness of electrets was assessed while comparisons were made with hydrogen chloride measuring devices from chamber and field tests, and computed results from a multilayer diffusion model. The experimental data used were obtained from 18 static test firings, chamber tests, and the Viking 1 launch to Mars. Results show that electrets have multipollutant measuring capabilities, simplicity of deployment, and speed of assessment. The electrets compared favorably with other hydrogen chloride measuring devices. The summary of the measured data from the electrets and the hydrogen chloride detectors was within the upper and lower bounds of the computed hydrogen chloride concentrations from the multilayer diffusion model.

Susko, M.↗

Performance Analysis of a Cost-Effective Electret Condenser Microphone Directional Array

Microphone directional array technology continues to be a critical part of the overall instrumentation suite for experimental aeroacoustics. Unfortunately, high sensor cost remains one of the limiting factors in the construction of very high-density arrays (i.e., arrays containing several hundred channels or more) which could be used to implement advanced beamforming algorithms. In an effort to reduce the implementation cost of such arrays, the authors have undertaken a systematic performance analysis of a prototype 35-microphone array populated with commercial electret condenser microphones. An ensemble of microphones coupling commercially available electret cartridges with passive signal conditioning circuitry was fabricated for use with the Langley Large Aperture Directional Array (LADA). A performance analysis consisting of three phases was then performed: (1) characterize the acoustic response of the microphones via laboratory testing and calibration, (2) evaluate the beamforming capability of the electret-based LADA using a series of independently controlled point sources in an anechoic environment, and (3) demonstrate the utility of an electret-based directional array in a real-world application, in this case a cold flow jet operating at high subsonic velocities. The results of the investigation revealed a microphone frequency response suitable for directional array use over a range of 250 Hz - 40 kHz, a successful beamforming evaluation using the electret-populated LADA to measure simple point sources at frequencies up to 20 kHz, and a successful demonstration using the array to measure noise generated by the cold flow jet. This paper presents an overview of the tests conducted along with sample data obtained from those tests.

Humphreys, William M., Jr.↗

Electrets used to measure exhaust cloud effluents from Solid Rocket Motor (SRM) during demonstration model (DM-2) static test firing

Electrets were compared with fixed flow samplers during static test firing. The measurement of the rocket exhaust effluents by samplers and electrets indicated that the Solid Rocket Motor had no significant effect on the air quality in the area sampled. The results show that the electrets (a passive device which needs no power) can be used effectively alongside existing measuring devices (which need power). By placing electrets in areas where no power is available, measurements may be obtained. Consequently, it is a valuable complementary instrument in measuring rocket exhaust effluents in areas where other measuring devices may not be able to assess the contaminants.

Susko, M.↗

Investigations of electret as a contamination control device

Thermoelectrets of polymers with stable surface charge on either side have been found to attract ions and charged particles to their surfaces. To assess their applicability to the control of atmospheric contamination, polytetraethylene (teflon) electrets are exposed to vapors coming from volatile mixtures over periods up to 90 min. Use is made of mass spectrometry for the analysis of teflon electret characteristics. It is found that even small quantities of the liquids in the mixture gives its characteristic mass spectra and that the peak height represents a measure for the quantity of the material collected over the electret surface, with the collected quantity being proportional to the duration of exposure.

Pillai, P. K. C.↗

Electrets used in measuring rocket exhaust effluents from the space shuttle's solid rocket booster during static test firing, DM-3

The purpose of this experimental research was to compare Marshall Space Flight Center's electrets with Thiokol's fixed flow air samplers during the Space Shuttle Solid Rocket Booster Demonstration Model-3 static test firing on October 19, 1978. The measurement of rocket exhaust effluents by Thiokol's samplers and MSFC's electrets indicated that the firing of the Solid Rocket Booster had no significant effect on the quality of the air sampled. The highest measurement by Thiokol's samplers was obtained at Plant 3 (site 11) approximately 8 km at a 113 degree heading from the static test stand. At sites 11, 12, and 5, Thiokol's fixed flow air samplers measured 0.0048, 0.00016, and 0.00012 mg/m3 of CI. Alongside the fixed flow measurements, the electret counts from X-ray spectroscopy were 685, 894, and 719 counts. After background corrections, the counts were 334, 543, and 368, or an average of 415 counts. An additional electred, E20, which was the only measurement device at a site approximately 20 km northeast from the test site where no power was available, obtained 901 counts. After background correction, the count was 550. Again this data indicate there was no measurement of significant rocket exhaust effluents at the test site.

Susko, M.↗

Topography and electrostatic interactions of electret fibres in N95 facemasks

Facemasks have been a critical line of defense in the Covid-19 pandemic and have been used for decades to reduce the inhalation of sub-micron aerosols, including bacteria, viruses and nano-materials. These facemasks leverage electrostatic charge properties of non-woven electret fibre mats to remove sub-micron aerosols. However, the topographical and electrostatic properties of these mats have not been well characterized at the nano-scale. In this study, we use atomic force microscopy (AFM) to examine the surface topography of the electret fibres within a commercial respirator fibre mat, use electrostatic force microscopy to map the electrostatic interactions emanating from these fibres, and use synchrotron X-ray scattering to probe polymer morphology. We find that within these mats the fibres exhibit significant heterogeneity in surface topography, electrostatic interactions and polypropylene phase composition. The surface topographies ranged from nano-smooth surfaces to ordered spherulitic structures. Furthermore, the electrostatic interactions varied across fibre length and circumference and are only weakly correlated with surface topographical features. Finally, we use AFM to characterize fibres after filtering a NaCl aerosol and find that the deposited particles are heterogeneous in size and distributed over the fibre surfaces.

36 MATERIALS SCIENCE↗

How Rigid Are Anthranilamide Molecular Electrets?

As important as molecular electrets are for electronic materials and devices, conformational fluctuations strongly impact their macrodipoles and intrinsic properties. Herein, we employ molecular dynamics (MD) simulations with the polarizable charge equilibrium (PQEq) method to investigate the persistence length (L P ) of molecular electrets composed of anthranilamide (Aa) residues. The PQEq-MD dissipates the accepted static notions about Aa macromolecules, and L P represents the shortest Aa rigid segments. The classical model with a single L P value does not describe these oligomers. Introducing multiple L P values for the same macromolecule follows the observed trends and discerns the enhanced rigidity in their middle sections from the reduced stiffness at their terminal regions. Furthermore, L P distinctly depends on solvent polarity. The Aa oligomers maintain extended conformations in nonpolar solvents with L P exceeding 4 nm, while in polar media, increased conformational fluctuations reduce L P to about 2 nm. These characteristics set key guidelines about the utility of Aa conjugates for charge-transfer systems within organic electronics and energy engineering.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrets and their application in contamination studies

Data are presented on the surface charge of many different types of electrets formed by several different techniques. Results are presented on the investigation of electrets as pollution control devices for their possible use in the control of a spacecraft environment.

Pillai, P., K.c.↗

Experimental research in the use of electrets in measuring effluents from rocket exhaust and a review of standard air quality measuring devices

Seven standard types of measuring devices used to obtain the chemical composition of rocket exhaust effluents were discussed. The electrets, a new measuring device, are investigated and compared with established measuring techniques. The preliminary results obtained show that electrets have multipollutant measuring capabilities, simplicity of deployment, speed of assessment or analysis, and may be an important and valuable tool in measuring pollutants from space vehicle rocket exhaust.

Susko, M.↗

Ground-based measurements of DM-2 rocket exhaust effluents using fixed-flow samplers and electrets

Electret devices were used to collect samples of rocket exhaust products. The samples were analyzed by X-ray spectroscopy. The performance of the electrets was compared with that of Thiokol fixed flow samplers during the static test firing of a solid rocket motor (SRM) demonstration model. A vertical profile of wind speed, wind direction, and air temperature, used as inputs to the multilayer diffusion model for the SRM static test is presented.

Susko, M.↗

Electrets and plant fluorometers used in field studies to measure hydrogen chloride produced during Space Shuttle launches

The results of the field tests of two monitoring device techniques, electrets and plant fluorometers are analyzed in order to determine the environmental effects of launch by-products and the extent of these effects. The STS launches are used because the Shuttle emits 2 1/2 times more HCl than any previous systems, it produces a voluminous ground cloud and, most important, it produces near field HCl deposition and revolatilization, far-field acid washout/rainout, and gaseous HCl diffusion. Field evaluations of electrets at STS-5, STS-6, and STS-8 have shown that qualitative assessments can be made for areas lightly or moderately impacted by gaseous and aerosol HCl. Field evaluation of the plant productivity fluorometer at STS-8 has shown that this system is also useful for qualitative assessment in areas lightly, moderately, or heavily affected by gaseous and aerosol HCl. Quantitative prediction of HCl may be possible in lightly and moderately affected areas, given deposition rates correlation.

Milligan, J. E.↗

Performance and electret charge of N95 respirators after decontamination [Slides]

Filtration, pressure drop and quantitative fit of N95 respirators were robust to several decontamination methods including vaporous hydrogen peroxide, wet heat, bleach, and ultraviolet light. Bleach may not have penetrated the hydrophobic outer layers of the N95 respirator. Isopropyl alcohol and detergent both severely degraded the electrostatic charge of the electret filtration layer. First data in N95 respirators that the loss of filtration efficiency was directly correlated with loss of surface potential on the filtration layer. The pressure drop was unchanged, so loss of filtration efficacy would not be apparent during a user seal check. Mechanical straps degrade with repeated mechanical cycling during extended use. Decontamination did not appear to degrade the elastic straps. Significant loss of strap elasticity would be apparent during a user negative pressure seal check.

36 MATERIALS SCIENCE↗

Charge Trapping in Polymer Electrets with Highly Dilute Blended Arylamine Donors

The nature of and ability to control biasing across dielectrics is a key area of research for the design of more versatile organic field-effect transistors (OFETs). One important technique to achieve such control is the inclusion of donor or acceptor molecules in the dielectric to modulate charge trapping therein. Here in this work, we report the effects of the additive concentration on OFETs with two different arylamines blended in polystyrene (PS) dielectrics, N,N'-diphenyl-N,N'-di-p-tolylbenzene-1,4-diamine (MPDA) and 4-anilinotriphenylamine (PATPA), as well as a comparison between PATPA/PS blends and dielectrics where PATPA was chemically tethered to the PS matrix. Dielectrics included in OFETs were subject to charging, and their charging capacity and stability were extracted from the OFET threshold voltages. For both MPDA/PS and PATPA/PS, blends with additive mole fractions as low as χ = 3 × 10 –4 were sufficient to cause increases in the charge trapping relative to pure PS dielectrics. We observed a pronounced inverse relationship between the capacity and stability of blended systems at larger mole fractions (χ = 10 –2 ) where the interadditive molecule distances became comparable to their size (~1 nm). Differences between MPDA and PATPA behaviors were consistent with their different structures and sizes. Furthermore, we found a small effect on electronic trapping arising from the chemical tethering of PATPA to the PS matrix. This result was consistent with the changes made to the additive during the tethering process and small compared to the observed differences arising from the concentration. These results suggest that the average intermolecular separation is a key determinant of charge storage stability in blended dielectrics.

36 MATERIALS SCIENCE↗