Search NASA⌕ Search

SEARCH · Search NASA

Results for “electret”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Electrets used in measuring rocket exhaust effuents from a Space Shuttle model

The study evaluates the use of electrets as a new contamination-detecting device designed to assess the chemical composition of rocket effluents. Evaluation of electret effectiveness revealed that electrets have multipollutant-measuring capability, simplicity of deployment and rapidity of assessment. Advantages of electrets are small size, light weight and cost-effectiveness. It is shown that electrets compare favorably with other HCl measuring devices. In particular, the summary of the measured data from electrets and HCl detectors is within the limits of computed HCl concentrations from the NASA/MSFC multilayer diffusion model.

Susko, M.↗

Research in the use of electrets in measuring effluents from rocket exhaust of the space shuttle (6.4 percent scaled model) and Viking 1 launch

Electrets used to detect the chemical composition of rocket exhaust effluents were investigated. The effectiveness of electrets was assessed while comparisons were made with hydrogen chloride measuring devices from chamber and field tests, and computed results from a multilayer diffusion model. The experimental data used were obtained from 18 static test firings, chamber tests, and the Viking 1 launch to Mars. Results show that electrets have multipollutant measuring capabilities, simplicity of deployment, and speed of assessment. The electrets compared favorably with other hydrogen chloride measuring devices. The summary of the measured data from the electrets and the hydrogen chloride detectors was within the upper and lower bounds of the computed hydrogen chloride concentrations from the multilayer diffusion model.

Susko, M.↗

Performance Analysis of a Cost-Effective Electret Condenser Microphone Directional Array

Microphone directional array technology continues to be a critical part of the overall instrumentation suite for experimental aeroacoustics. Unfortunately, high sensor cost remains one of the limiting factors in the construction of very high-density arrays (i.e., arrays containing several hundred channels or more) which could be used to implement advanced beamforming algorithms. In an effort to reduce the implementation cost of such arrays, the authors have undertaken a systematic performance analysis of a prototype 35-microphone array populated with commercial electret condenser microphones. An ensemble of microphones coupling commercially available electret cartridges with passive signal conditioning circuitry was fabricated for use with the Langley Large Aperture Directional Array (LADA). A performance analysis consisting of three phases was then performed: (1) characterize the acoustic response of the microphones via laboratory testing and calibration, (2) evaluate the beamforming capability of the electret-based LADA using a series of independently controlled point sources in an anechoic environment, and (3) demonstrate the utility of an electret-based directional array in a real-world application, in this case a cold flow jet operating at high subsonic velocities. The results of the investigation revealed a microphone frequency response suitable for directional array use over a range of 250 Hz - 40 kHz, a successful beamforming evaluation using the electret-populated LADA to measure simple point sources at frequencies up to 20 kHz, and a successful demonstration using the array to measure noise generated by the cold flow jet. This paper presents an overview of the tests conducted along with sample data obtained from those tests.

Humphreys, William M., Jr.↗

Electrets used to measure exhaust cloud effluents from Solid Rocket Motor (SRM) during demonstration model (DM-2) static test firing

Electrets were compared with fixed flow samplers during static test firing. The measurement of the rocket exhaust effluents by samplers and electrets indicated that the Solid Rocket Motor had no significant effect on the air quality in the area sampled. The results show that the electrets (a passive device which needs no power) can be used effectively alongside existing measuring devices (which need power). By placing electrets in areas where no power is available, measurements may be obtained. Consequently, it is a valuable complementary instrument in measuring rocket exhaust effluents in areas where other measuring devices may not be able to assess the contaminants.

Susko, M.↗

Investigations of electret as a contamination control device

Thermoelectrets of polymers with stable surface charge on either side have been found to attract ions and charged particles to their surfaces. To assess their applicability to the control of atmospheric contamination, polytetraethylene (teflon) electrets are exposed to vapors coming from volatile mixtures over periods up to 90 min. Use is made of mass spectrometry for the analysis of teflon electret characteristics. It is found that even small quantities of the liquids in the mixture gives its characteristic mass spectra and that the peak height represents a measure for the quantity of the material collected over the electret surface, with the collected quantity being proportional to the duration of exposure.

Pillai, P. K. C.↗

Electrets used in measuring rocket exhaust effluents from the space shuttle's solid rocket booster during static test firing, DM-3

The purpose of this experimental research was to compare Marshall Space Flight Center's electrets with Thiokol's fixed flow air samplers during the Space Shuttle Solid Rocket Booster Demonstration Model-3 static test firing on October 19, 1978. The measurement of rocket exhaust effluents by Thiokol's samplers and MSFC's electrets indicated that the firing of the Solid Rocket Booster had no significant effect on the quality of the air sampled. The highest measurement by Thiokol's samplers was obtained at Plant 3 (site 11) approximately 8 km at a 113 degree heading from the static test stand. At sites 11, 12, and 5, Thiokol's fixed flow air samplers measured 0.0048, 0.00016, and 0.00012 mg/m3 of CI. Alongside the fixed flow measurements, the electret counts from X-ray spectroscopy were 685, 894, and 719 counts. After background corrections, the counts were 334, 543, and 368, or an average of 415 counts. An additional electred, E20, which was the only measurement device at a site approximately 20 km northeast from the test site where no power was available, obtained 901 counts. After background correction, the count was 550. Again this data indicate there was no measurement of significant rocket exhaust effluents at the test site.

Susko, M.↗

Electrets and their application in contamination studies

Data are presented on the surface charge of many different types of electrets formed by several different techniques. Results are presented on the investigation of electrets as pollution control devices for their possible use in the control of a spacecraft environment.

Pillai, P., K.c.↗

Experimental research in the use of electrets in measuring effluents from rocket exhaust and a review of standard air quality measuring devices

Seven standard types of measuring devices used to obtain the chemical composition of rocket exhaust effluents were discussed. The electrets, a new measuring device, are investigated and compared with established measuring techniques. The preliminary results obtained show that electrets have multipollutant measuring capabilities, simplicity of deployment, speed of assessment or analysis, and may be an important and valuable tool in measuring pollutants from space vehicle rocket exhaust.

Susko, M.↗

Ground-based measurements of DM-2 rocket exhaust effluents using fixed-flow samplers and electrets

Electret devices were used to collect samples of rocket exhaust products. The samples were analyzed by X-ray spectroscopy. The performance of the electrets was compared with that of Thiokol fixed flow samplers during the static test firing of a solid rocket motor (SRM) demonstration model. A vertical profile of wind speed, wind direction, and air temperature, used as inputs to the multilayer diffusion model for the SRM static test is presented.

Susko, M.↗

Electrets and plant fluorometers used in field studies to measure hydrogen chloride produced during Space Shuttle launches

The results of the field tests of two monitoring device techniques, electrets and plant fluorometers are analyzed in order to determine the environmental effects of launch by-products and the extent of these effects. The STS launches are used because the Shuttle emits 2 1/2 times more HCl than any previous systems, it produces a voluminous ground cloud and, most important, it produces near field HCl deposition and revolatilization, far-field acid washout/rainout, and gaseous HCl diffusion. Field evaluations of electrets at STS-5, STS-6, and STS-8 have shown that qualitative assessments can be made for areas lightly or moderately impacted by gaseous and aerosol HCl. Field evaluation of the plant productivity fluorometer at STS-8 has shown that this system is also useful for qualitative assessment in areas lightly, moderately, or heavily affected by gaseous and aerosol HCl. Quantitative prediction of HCl may be possible in lightly and moderately affected areas, given deposition rates correlation.

Milligan, J. E.↗

Fabrication and applications of electrets

Permanently charged dielectrics can be made less expensively, faster, and more effectively using improved techniques and materials. Methods include charge injection, Tesla-coil charging, and molten spray. Possible uses include pollution control, low-power sensors, and illumination control.

Pillai, P. K. C.↗

Insights From Routine Microbiological Monitoring of Air in Astromaterials Curation Cleanrooms

NASA maintains nine separate cleanrooms at the Johnson Space Center to curate and preserve astromaterials samples. Routine microbial monitoring of the surfaces in these cleanrooms began in 20181. Until recently, materials compatibility requirements prevented monitoring airborne biological particles in all but one of these cleanrooms. New astromaterials collections from carbon rich asteroids are more susceptible to biological degradation than previous collections. Therefore, it is important to monitor the bioburden in the air and on surfaces in these labs. Establishing a comprehensive microbial monitoring program will help inform the monitoring and curation plans for Mars sample return which will include samples that are extremely biologically sensitive. In April of 2022 we began routinely collecting air samples in seven of the nine curation cleanrooms (Meteorite ISO 7 equivalent, Lunar ISO 6 equivalent, Stardust, Hayabusa2, OSIRIS-REx ISO 5 equivalent, and Genesis ISO 4 equivalent) using a sampling device that collects airborne biological particles on an electret filter instead conventional sampler that collect cells in a liquid media or onto organic rich Petri dishes. Electret is a generic term for electrostatically charged media. The charge on these materials increases particle trapping when compared to non-charged filters of similar thickness. N95 respirators also use electret filters. This dry sample collection method allows us to meet materials requirements for all the curation labs and reduces the risk of inadvertently introducing contamination as part of our monitoring effort. This method also allows us to preserve a portion of each sample for DNA extraction and next generation sequencing. DNA sequencing helps us to characterize the portion of the cleanroom microbiome that we cannot culture. We will present the results of our first 8 months of monitoring, compare these results to particle counts in the labs and to measurements made directly onto Petri dishes when possible. We will also make recommendations for modifications to the sampling method to improve sampling efficiency and preserve diversity.

A. B. Regberg↗

A Portable Infrasonic Detection System

During last couple of years, NASA Langley has designed and developed a portable infrasonic detection system which can be used to make useful infrasound measurements at a location where it was not possible previously. The system comprises an electret condenser microphone, having a 3-inch membrane diameter, and a small, compact windscreen. Electret-based technology offers the lowest possible background noise, because Johnson noise generated in the supporting electronics (preamplifier) is minimized. The microphone features a high membrane compliance with a large backchamber volume, a prepolarized backplane and a high impedance preamplifier located inside the backchamber. The windscreen, based on the high transmission coefficient of infrasound through matter, is made of a material having a low acoustic impedance and sufficiently thick wall to insure structural stability. Close-cell polyurethane foam has been found to serve the purpose well. In the proposed test, test parameters will be sensitivity, background noise, signal fidelity (harmonic distortion), and temporal stability. The design and results of the compact system, based upon laboratory and field experiments, will be presented.

Shams, Qamar A.↗