An automatic electrical distribution system
Computer controlled electric power distribution system for aerospace systems
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Computer controlled electric power distribution system for aerospace systems
It is technically feasible to design a satellite communication system to serve the United States electric utility industry's needs relative to load management, real-time operations management, remote meter reading, and to determine the costs of various elements of the system. A definition of distribution control and monitoring functions is given. Associated communications traffic is quantified. A baseline conceptual design in terms of operating capability and equipment is described, important factors to be considered in designing a system are examined, and preliminary cost data are provided. Factors associated with implementation are discussed and conclusions and recommendations are listed.
It is technically feasible to design a satellite communication system to serve the United States electric utility industry's needs relative to load management, real-time operations management, remote meter reading and to determine the costs of various elements of the system. The functions associated with distribution automation and control and communication system requirements are defined. Factors related to formulating viable communication concepts, the relationship of various design factors to utility operating practices, and the results of the cost analysis are discussed The system concept and several ways in which the concept could be integrated into the utility industry are described.
Explore the source record for details and available documents.
An astronaut caution and warning system is described which monitors various life support system parameters and detects out-of-range parameter conditions. The warning system generates a warning tone and displays the malfunction condition to the astronaut along with the proper corrective procedures required.
The electric power distribution systems for spacecraft are compared concentrating on two interrelated issues: the choice between dc and high frequency ac, and the converter/inverter topology to be used at the power source. The relative merits of dc and ac distribution are discussed. Specific converter and inverter topologies are identified and analyzed in detail for the purpose of detailed comparison. Finally, specific topologies are recommended for use in dc and ac systems.
This paper presents the results of a study into the feasibility of using satellite communications for a country-wide system of electric distribution system monitoring and control. The concept selected for study involves the use of a geostationary satellite with a large multi-beam antenna to provide a major part of the communications and control network between participating utilities and various elements of their power distribution networks, including customer loads. Electric utility communications requirements are projected through 1995 in order to size the required capacity of the system. Two basic systems are examined: a one-way system for load control, and a two-way system for distribution system monitoring and control, including customer meter reading. An operating protocol is proposed for each system. Preliminary cost estimates are identified element by element. Finally, expansion of the basic system to include a set of ancillary communications functions is briefly discussed.
The SUSAN Electrofan is a new hybrid electric large regional jet aircraft concept being studied by NASA that leverages advanced propulsion system technologies such as distributed electric propulsion (DEP) and boundary-layer ingestion (BLI) to reduce fuel consumption and emissions. In order to evaluate the individual benefits of these technologies toward the SUSAN Electrofan’s wing-mounted propulsion systems, three configurations are proposed. The first consists of two underwing pylon-mounted podded propulsors and serves as a baseline, while the second features an underwing pylon-mounted DEP concept with 16 ducted fans in a mail-slot nacelle. The third and final configuration mounts the mail-slot nacelle directly onto the pressure side of the wing to also take advantage of BLI. This paper presents preliminary investigations into the design and performance of the first two propulsion system configurations. This begins with an initial propulsor and mail-slot design where the aeropropulsive design space is explored, and adverse effects are addressed through iterative geometry modifications. The propulsion system configurations are then installed onto a wing–body model to account for integration effects and assess the relative aerodynamic and shaft power performance of each concept. Results indicate the potential benefits of DEP, which come from significant reductions in total drag, provided by operation at much lower propulsor fan pressure ratios.
Hybrid- and all-electric aircraft concepts use electric motors for power rather than a conventional jet engine. Electric propulsors open the door to new ways to synergistically integrate the propulsion system with the airframe. For example, many small electric propulsors can be distributed along the wing to increase the effective bypass ratio for better overall efficiency. Furthermore, these propulsors can be attached to the wing surface for boundary layer ingestion(BLI) to further the efficiency gains. However, these novel methods of aeropropulsive integration also create challenges such as nonuniform inflow and complex nacelle geometries. Here we use gradient-based aerodynamic shape optimization to address the design challenges of the wing-mounted distributed electric propulsion system of the Subsonic Single Aft Engine (SUSAN)concept. In doing so, we aim to more accurately benchmark the flow power of SUSAN’s mail slot propulsors relative to a conventional propulsion system in both an isolated and BLI configuration. Our preliminary results found relative to an optimized podded propulsor the optimized mailslot and BLI mailslot design required 8% and 17% more flow power respectively.The methods and key design insights also apply to other aircraft concepts that utilize distributed electric propulsion and boundary layer ingestion.
This paper describes an approach to creating simulations of the electric components for a hybrid electric propulsion system. The proposed modeling technique is based on power/load flow modeling and is designed to provide a modular framework that includes buses, lines, and other electrical components that can be connected together to form the electrical distribution system. The purpose of this paper is to detail an electric distribution system modeling technique and to demonstrate how these models may be integrated with turbomachinery simulations. These general modeling techniques were created to be utilized for system and control design studies. Additionally, steady-state and dynamic performance for a proposed model example is compared with data from a hardware in the loop simulation.
This paper describes an approach to creating simulations of the electric components for a hybrid electric propulsionsystem. The proposed modeling technique is based on power/load flow modeling and is designed to provide a modularframework that includes buses, lines, and other electrical components that can be connected together to form the electrical distribution system. The purpose of this paper is to detail an electric distribution system modeling technique and to demonstrate how these models may be integrated with turbomachinery simulations. These general modeling techniques were created to be utilized for system and control design studies. Additionally, steady-state and dynamic performance for a proposed model example is compared with data from a hardware in the loop simulation.
Systems and methods for identifying a fault in an electrical distribution system may include capturing an image of a corona event associated with a component of the electrical distribution system and processing the image of the corona event to identify the center and boundary of the corona event. An overlay for display with the image of the corona event may be generated, where the overlay identifying at least a center of the corona event and may be displayed to a user via a user interface device. In some cases, an unmanned aerial vehicle may comprise one or more image sensors capable of capturing the image of the corona event and communicate the images to a remote device for processing and display to the user. The image captured by the image sensors may include an ultraviolet image, a visible spectrum image, an infrared image, or a combination of image types.
STOL aircraft electric power variable frequency generation and high voltage DC distribution with secondary square wave AC distribution
Assumptions made and techniques used in modeling the power network to the 480 volt level are discussed. Basic computational techniques used in the short circuit program are described along with a flow diagram of the program and operational procedures. Procedures for incorporating network changes are included in this user's manual.
The Kennedy Space Center voltage profile program computes voltages at all busses greater than 1 Kv in the network under various conditions of load. The computation is based upon power flow principles and utilizes a Newton-Raphson iterative load flow algorithm. Power flow conditions throughout the network are also provided. The computer program is designed for both steady state and transient operation. In the steady state mode, automatic tap changing of primary distribution transformers is incorporated. Under transient conditions, such as motor starts etc., it is assumed that tap changing is not accomplished so that transformer secondary voltage is allowed to sag.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The space station's electrical power system will evolve and grow in a manner much similar to the present terrestrial electrical power system utilities. The initial baseline reference configuration will contain more than 50 nodes or busses, inverters, transformers, overcurrent protection devices, distribution lines, solar arrays, and/or solar dynamic power generating sources. The system is designed to manage and distribute 75 KW of power single phase or three phase at 20 KHz, and grow to a level of 300 KW steady state, and must be capable of operating at a peak of 450 KW for 5 to 10 min. In order to plan far into the future and keep pace with load growth, a load flow power system analysis approach must be developed and utilized. This method is a well known energy assessment and management tool that is widely used throughout the Electrical Power Utility Industry. The results of a comprehensive evaluation and assessment of an Electrical Distribution System Analysis Program (EDSA) is discussed. Its potential use as an analysis and design tool for the 20 KHz space station electrical power system is addressed.