Search NASA⌕ Search

SEARCH · Search NASA

Results for “electric heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Grid-Scale Electricity Storage at Lowest Possible Cost Enabled by Pumped Heat Electricity Storage (Final Report)

Grid-scale energy storage technologies that can provide greater than 10 hours of electricity at full power address a critical need for full penetration of renewables on electricity grids worldwide, minimize renewable curtailment, and maximize grid security and reliability. Pumped Heat Energy Storage (PHES) systems can store energy thermally in any location at the low costs necessary for displacing fossil fuels, reducing foreign fuel imports, and reducing emissions to maintain the energy security of the United States. The award allowed Southwest Research Institute® (SwRI®) and Malta, Inc. (Malta) to advance the PHES concept to a proof-of-concept demonstration for a kW-scale system. The project focused on system operation and integration. The main project objectives were: 1. Address first implementation challenges 2. Explore system control strategies and operation 3. Translate lessons learned to the full-scale system Through these objectives the project completes a first demonstration of this technology and reduces the technical risk associated with a full-scale system.

25 ENERGY STORAGE↗

Repetitively pulsed nanosecond discharge plasma decay in propane–oxygen gas mixture in the presence of a heating electric field

Plasma decay in the afterglow of a repetitively pulsed nanosecond discharge in a stoichiometric propane–oxygen mixture was experimentally investigated when a weak heating DC electric field was applied and in its absence. The discharge was ignited at room gas temperature and a pressure of 1–2 Torr and was characterized by low specific energy inputs (<0.004 eV per molecule in one pulse). Using microwave interferometry, the temporal evolution of the electron density during plasma decay was studied, and the effective recombination coefficients were obtained from data processing. It was shown that the rate of plasma decay behaved in a non-monotonic manner with increasing degree of propane oxidation; at first the decay rate grew, then passed through a maximum, fell and saturated in the limit of a large (~2000) number of pulses. In this limit, the effect of the heating DC electric field on the plasma decay decreased with approaching chemical equilibrium. Numerical simulation of the observed effects was performed for low and high oxidation degrees of propane taking into account changes in the composition of positive ions in the plasma. Good agreement was obtained between measurements and calculations of the electron density during plasma decay in these cases. Here it was shown that the formation of cluster ions in the discharge afterglow plays a fundamental role. The plasma decay was controlled by electron recombination with hydrocarbon cluster ion at low oxidation degree of propane and with water cluster (hydrated) ions at high oxidation degree. A hypothesis was proposed to explain the observed nonmonotonic behavior of the plasma decay rate with an increase in the propane oxidation in the discharge, based on the formation of hydrated hydrocarbon ions C x H y + (H 2 O) k at moderate oxidation degrees.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

General-Purpose Heat Source Radioisotope Thermoelectric Generator Flight Unit 5 Refurbished (GPHS-RTG F5R) Electrically Heated Thermal Vacuum Testing

Idaho National Laboratory (INL) has been tasked with the evaluation and refurbishment of the General Purpose Heat Source (GPHS) Radioisotope Thermoelectric Generator (RTG) Flight Unit 5 (GPHS-RTG F5R or F5R) that was defueled in 2005. This paper describes the testing of F5R in the thermal vacuum chamber and evaluation of the data demonstrating the generator meets updated Cassini-Huygens requirements. The generator produced 260 We of power at the specified 4100 Wth heat source inventory. This power exceeded the power requirement for 250 We , confirming system integrity and demonstrating that the generator is capable of potential NASA missions.

30 - DIRECT ENERGY CONVERSION↗

GPHS-RTG F5R Electrically Heated Thermal Vacuum Testing

Idaho National Laboratory (INL) has been tasked with the evaluation and refurbishment of the General Purpose Heat Source (GPHS) Radioisotope Thermoelectric Generator (RTG) Flight Unit 5 (GPHS-RTG F5R or F5R) that was defueled in 2005. This paper describes the testing of F5R in the thermal vacuum chamber and evaluation of the data demonstrating the generator meets updated Cassini-Huygens requirements. The generator produced 260 We of power at the specified 4100 Wth heat source inventory. This power exceeded the power requirement for 250 We , confirming system integrity and demonstrating that the generator is capable of potential NASA missions.

30 - DIRECT ENERGY CONVERSION↗

Electrically heated balance piston seal

A balance piston seal assembly for a balance piston of a compressor is provided. The balance piston seal assembly may include a balance piston seal configured to be disposed about the balance piston such that an inner radial surface of the balance piston seal and an outer radial surface of the balance piston define a radial clearance therebetween. The balance piston seal assembly may also include a plurality of heaters in thermal communication with the balance piston seal and configured to heat and thermally expand the balance piston seal and thereby increase a radial length of the radial clearance.

42 ENGINEERING↗

Deep learning–based digital twins for heat pumps

Heat pumps are effective cooling and heating appliances to save energy in buildings. However, traditional heat pump models are challenging to integrate with building demands in a co-simulation environment because of the nonlinear thermodynamics of refrigerants. Developing digital twin representatives for heat pumps capable of faster calculations with good accuracy is desirable. This study aimed to establish a generic deep learning–based digital twin for heat pumps with a large amount of high-fidelity data. Two refrigerants for two different heat pumps were considered: an air source heat pump with refrigerant R-410A, an air source heat pump with refrigerant CO 2 , a water source heat pump with refrigerant R-410A, and a water source heat pump with refrigerant CO 2 . Furthermore, results showed that the deep learning (long short-term memory) models effectively represented these four heat pumps as a digital twin: (a) accuracy for training and testing showed smaller than 0.02 for heating electricity and heating demands, and (b) the digital twins showed good consistency with original data for heating electricity and heating demands (root mean square errors of less than 0.12 W and 0.19 W, respectively). Therefore, deep learning–based heat pump models can be used in the co-simulation of building mechanical systems.

Air source heat pump↗

Coupling Chemical Heat Pump with Nuclear Reactor for Temperature Amplification by Delivering Process Heat and Electricity: A Techno-Economic Analysis

The energy economy is continually evolving in response to socio-political factors in the nature of primary energy sources, their conversions to useful forms, such as electricity and heat, and their utilization in different sectors. Nuclear energy has a crucial role to play in the evolution of energy economy due to its clean and non-carbon-emitting characteristics. A techno-economic analysis was undertaken to establish the viability of selling heat along with electricity for an advanced 100 MWth small modular reactor (SMR) and four nuclear hybrid energy system (NHES) configurations featuring the SMR paired with chemical heat pump (ChHP) systems providing a thermal output ranging from 1 to 50 MWth. Net present value, payback period, discounted cash flow rate of return, and levelized cost of energy were evaluated for these systems for different regions of U.S. reflecting a range of electricity and thermal energy costs. The analysis indicated that selling heat to high temperature industrial processes showed profitable outcomes compared to the sale of only electricity. Higher carbon taxes improved the economic parameters of the NHES alternatives significantly. Providing heat to high temperature industries could be very beneficial, helping to cut down the greenhouse gases emission by reducing the fossil fuel consumption.

Gupta, Aman↗

System and method for combined heat and electric power generation

A system for combined heat and electric power generation, preferably including a heat reservoir and one or more electric generators, each preferably including a heat source and an energy converter. A method for combined heat and electric power generation, preferably including activating an electric generator, deactivating the electric generator, and/or providing heat from a heat reservoir.

Lorimer, Adam↗

System and method for combined heat and electric power generation

A system for combined heat and electric power generation, preferably including a heat reservoir and one or more electric generators, each preferably including a heat source and an energy converter. A method for combined heat and electric power generation, preferably including activating an electric generator, deactivating the electric generator, and/or providing heat from a heat reservoir.

Lorimer, Adam G.↗

Superhydrophobic heat exchangers delay frost formation and enhance efficency of electric vehicle heat pumps

The number of electric vehicles has rapidly expanded as high-performance automotive lithium-ion batteries have become more affordable. However, the range of electric vehicles decreases in cold climates partly because of the additional thermal loads associated with cabin heating. One way to improve the efficiency of cabin heating is to replace resistive heating elements with an air-source heat pump system. However, to gain the full benefit of heat pumping, frost formation on the outdoor heat exchanger must be minimized. In this work, we modified the surface wettability of aluminum louvered-fin automotive heat pump evaporators and tested them under realistic operating conditions in a transcritical carbon dioxide (CO 2 ) heat pump. Each heat exchanger underwent several consecutive frosting and defrosting cycles to understand the cyclic performance of the system. The heat exchanger with a superhydrophobic outer surface was able to delay frost formation and maintain higher heat transfer rates when compared to heat exchangers with higher surface energies (hydrophilic). The delayed frost formation resulted in a system efficiency benefit in the first few frosting cycles but diminished in later cycles due to water retention and incomplete defrosting. However, for most automotive applications the superhydrophobic heat exchanger showed substantial benefits for normal driving trips. We report the scalable and optimized superhydrophobic heat exchangers developed here have the potential to increase the efficiency of automotive heat pumps and consequently increase the range and reduce energy consumption of electric vehicles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of Electric Space Heating in Multifamily Apartments in Juneau, Alaska [Slides]

The study objective was to understand the change in electrical consumption and cost after the addition of a ductless mini-split air-source heat pump (ASHP) across rental apartments heated by electrical resistance heating systems in multifamily buildings in Juneau, Alaska. Alaska Electric Light and Power Company (AELP), the utility in Juneau, Alaska, funded installation of 19 heat pumps across four buildings. Using electrical meter interval data, including the total apartment consumption and submeter data for each heating appliance (electric resistance baseboard and heat pump), the National Laboratory of the Rockies (NLR) calculated energy use metrics before and after heat pump installation and visualized results. Through this research, NLR compares electrical use (total and specific to heating appliances), adjusted for weather and apartment size, and electrical demand in the year before and after installation of an ASHP across study units. The results will inform the utility and residents of documented energy and cost savings from transitioning building heating systems to a higher-efficiency electricity-based appliance, deliver a basis for building energy modeling across other multifamily housing dwellings, and enable estimates of potential electricity savings to AELP grid under widespread adoption scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Environmental and Economic Assessment of Portable Systems: Production of Wood-Briquettes and Torrefied-Briquettes to Generate Heat and Electricity

This study assessed the environmental impacts and economic feasibility of generating heat using wood-briquettes (WBs), and heat and electricity using torrefied-wood-briquettes (TWBs). WBs and TWBs were manufactured from forest residues using portable systems and delivered to either residential consumers or power plants in the United States. An integrated cradle-to-grave life-cycle assessment (LCA) and techno-economic analysis (TEA) approach was used to quantify environmental impacts and minimum-selling prices (MSPs) of heat and electricity, respectively. Results illustrated that 82% and 59% of the cradle-to-grave global warming (GW) impact of producing heat resulted from the feedstock preparation in WBs and torrefaction in TWBs, respectively. About 46–54% of total cost in the production of heat were from labor and capital costs only. The GW impact of electricity production with TWBs was dominated by the torrefaction process (48% contribution). Capital cost (50%) was a major contributor to the total cost of electricity production using TWBs. The GW impacts of producing heat were 7–37 gCO₂eq/MJ for WBs, and 14–51 gCO₂eq/MJ for TWBs, whereas producing electricity using TWBs was 146–443 gCO₂eq/kWhe. MSPs of generating heat from WBs and TWBs were €1.09–€1.73 and €1.60–€2.26/MJ, respectively, whereas the MSP of electricity from TWBs was €20–€25/kWhe. Considering carbon and pile-burn credits, MSPs of heat and electricity were reduced by 60–90% compared to the base-case.

Sahoo, Kamalakanta (ORCID:0000000277635296)↗