Search NASA⌕ Search

SEARCH · Search NASA

Results for “electric penetration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Multipole-Based Cable Braid Electromagnetic Penetration Model: Electric Penetration Case

In this paper, we investigate the electric penetration case of the first principles multipole-based cable braid electromagnetic penetration model reported in the Progress in Electromagnetics Research B 66, 63–89 (2016). We first analyze the case of a 1-D array of wires: this is a problem which is interesting on its own, and we report its modeling based on a multipole-conformal mapping expansion and extension by means of Laplace solutions in bipolar coordinates. We then compare the elastance (inverse of capacitance) results from our first principles cable braid electromagnetic penetration model to that obtained using the multipole-conformal mapping bipolar solution. These results are found in a good agreement up to a radius to half spacing ratio of 0.6, demonstrating a robustness needed for many commercial cables. We then analyze realistic cable implementations without dielectrics and compare the results from our first principles braid electromagnetic penetration model to the semiempirical results reported by Kley in the IEEE Transactions on Electromagnetic Compatibility 35, 1–9 (1993). Finally, although we find results on the same order of magnitude of Kley's results, the full dependence on the actual cable geometry is accounted for only in our proposed multipole model which, in addition, enables us to treat perturbations from those commercial cables measured.

42 ENGINEERING↗

SMR Containment Cable and Electrical Penetration Assembly System

GAIN Project CRADA Number NFE-21-08839, entitled “SMR Containment Cable and EPA System” was initiated by the partnership of Oak Ridge National Laboratory (ORNL) and Engineered Solutions Group (ESG) to test an ESG-designed Electrical Penetration Assembly and Containment Cabling System Qualified for not only SMR technologies, but also Advanced Reactors design. An Electrical Penetration Assembly (EPA) is a component used to allow electrical power and signal conductors as well as optical fiber through the nuclear reactor’s containment structure while maintaining a pressure barrier. The EPA ensures the containment's integrity both during the normal operation and also accident conditions by providing a sealed passage for power and signals. This project was undertaken to fill the equipment gap of EPA and Cabling Systems that require much more severe environmental requirements than legacy plant applications present due to their smaller containment volumes that result in high energy densities compared to legacy designs. This high energy density results in severe accident environments and also more severe normal operating conditions.This document describes cost effective approaches to qualify a unique EPA for Small Modular Reactor (SMR) technologies as legacy LWR EPA technologies will likely have inherent material performance insufficiencies. The DBA profiles for SMRs (and some Advanced Reactor Technologies) are more severe than the legacy qualification requirements making the design of the qualification testing system challenging as the temperatures and pressures can approach the limits permitted by ASME Pressure Vessel Code, as well as accident temperatures exceeding the capability of polymeric gaskets and dielectrics. Small Modular Reactors are designed to have, as the name suggests, modularity which implies sized for factory fabrication and subsequent assembly at the power plant site. SMR containment is much smaller than a legacy Light Water Reactor containment. The containment walls are likely to be comprised of stainless steel. Qualifying Electrical Penetration Assemblies (EPAs) through these steel vessels are of interest in this work. Methods are presented here that discuss critical safety and cost effectiveness for these SMR EPA’s test systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Engineered Solutions Group's SMR Containment Cable and Electrical Penetration Assembly System

GAIN Project CRADA Number NFE-21-08839, entitled “SMR Containment Cable and EPA System” was initiated by the partnership of Oak Ridge National Laboratory (ORNL) and Engineered Solutions Group (ESG) to test an ESG-designed Electrical Penetration Assembly and Containment Cabling System Qualified for not only legacy LWR designs, but also Small Modular Reactors designs currently being designed by several different suppliers. This project was undertaken to fill the equipment gap of EPA and Cabling Systems that require much more severe environmental requirements than legacy plant applications present due to their smaller containment volumes that result in high energy densities compared to legacy designs. This high energy density results in severe accident environments and more severe normal operating conditions as well. We developed two approaches to qualify Electrical Penetration Assembly (EPA) and Containment Cabling Systems for SMRs and Advanced Reactors. We take into consideration the more severe environmental parameters found with SMR designs. The system will need to meet a qualification test program addressing wear/cyclic aging, potential radiation exposure, thermal aging, vibration aging, thermal cycling, seismic qualification, electrical fault testing (per IEEE 317) and accident simulation. The equipment must meet the requirements of 10CFR50.49, GDC 50 in 10CFR50 Appendix A, and 10CFR50 Appendix J. NRC Regulatory Guides (RGs) identify an acceptable way of meeting regulatory requirements. RGs frequently endorse a standard for meeting these requirements. Specific to this review, equipment would be qualified in accordance with the following IEEE Standards. • IEEE 317-2013 (Electrical Penetration Assemblies), which is endorsed by RG 1.63, Rev. 3, • IEEE 323-2003 and the more current IEC/IEEE 60780-323 (Environmental Qualification of 1E Equipment) which is endorsed by RG 1.89. IEEE 323-2003 is endorsed by RG 1.209, • IEEE 344-2020 (Seismic Qualification. The 2013 version endorsed by RG 1.100, Rev. 4, with exceptions), • IEEE 383-2015 (Electrical Cables) (which is endorsed by RG 1.189 Rev. 4 and the -2003 version endorsed by RG 1.211 rev. 0), • IEEE 572-2019 (Electrical Connectors and Assemblies), which is endorsed by 1.156 Rev 1, and • [IEEE 1202 (endorsed by RG 1.189) would normally be applicable but the advanced cable designs are impervious to this cable flame test.] The primary goal of such a program is to provide an EPA design that can meet the qualification requirements for all legacy light water reactor plants currently operating as well as new plant designs including light water Small Modular Reactors. Thus, these requirements are applicable to plants licensed under 10CFR50 and 10CFR52. Other reactor designs may be evaluated, and this test system and qualification method applied to those applications if the requirements would satisfy the requirements of the intended plant. A secondary benefit of this work is to document some of the history and background in these requirements as there have been recent delays in an SMR licensing process due to NRC Requests for Additional Information in this subject matter area.

42 ENGINEERING↗

Water Impacts of High Solar PV Electricity Penetration

This analysis provides a detailed national and regional description of the water-related impacts and constraints of high solar electricity penetration scenarios in the U.S. in 2030 and 2050. A modified version of the Regional Energy Deployment System (ReEDS) model that incorporates water resource availability and costs as a constraint in each of its 134 Balancing Area (BA) regions was utilized to explore national and regional differences in water use impacts and solar deployment locations under different solar energy cost and water availability scenarios (Macknick et al. 2015). Water resource availability and cost data are from recently completed research at Sandia National Laboratories (Tidwell et al. 2013a). Scenarios analyzed include two business-as-usual solar energy cost cases, one with and one without considering available water resources, and four solar energy cost cases that meet the SunShot cost goals (i.e., $1/watt for utility-scale PV systems), with varying levels of water availability restrictions. This analysis provides insight into the role solar energy technologies have in the broader electricity sector under scenarios of water constraints.

14 SOLAR ENERGY↗

Penetration Electric Fields and Inner Magnetosphere Dynamics: A Model and Data Comparison

The initial substorm interval to be studied has been selected to be the magnetic storm of June 4, 1991, and following. The CRRES electric and magnetic field data has been processed. We have added DMSP ion drift and energetic particle data and further refined the CRRES data for intercomparison. The DMSP data increase the frequency of monitoring of the temporal response of the penetration electric fields to every 100 min. Energy is seen to flow between the ionosphere and magnetosphere at low L values during the main phase of the magnetic storm in the form of field-aligned Poynting flux. This indicates electrodynamic coupling of the regions with Alfven waves. The first comparisons of the data with outputs of the Rice Magnetospheric Specification Model (MSM) were made. Both positive and negative correlation were seen as might be expected. Differences were especially evident in the time constants of the processes. Comparisons with the more physically self-consistent Rice Convection Model (RCM) with both electric fields and particle data are in progress to suggest physical constraints for our understanding of the phenomena.

Maynard, Nelson C.↗

Enhanced electrical penetration components meet the high safety standards required for China's HTR-PM Shidaowan and generation mPower small modular reactors - 300

Enhanced glass-to-metal feedthroughs will be used to carry key instrumentation and control (I and C) signals in China's high-temperature, gas-cooled pebble-bed modular reactor (HTR-PM) at Shidaowan, and in Small Modular Reactor (SMR) prototyping. Chinergy Co., Ltd and Jiamusi Electric Machine Co., Ltd will use the feedthroughs, also called electrical penetration assemblies (EPAs), at the Shidaowan twin-reactor high temperature reactor (HTR). These feedthroughs are manufactured using specialized processes that make them far more robust than counterparts made with organic or ceramic materials. Improved EPAs manufactured by SCHOTT are the only feedthrough solution that can be used in the primary loop of an HTR because organic seals cannot withstand the high temperatures and pressures of this environment. Glass-to-metal seals (GTMS) are made using inorganic, non-aging materials which enable a virtually unlimited lifespan in high-temperature, high-radiation and high-pressure applications. This I and C technology package is being enhanced by the development and testing of new mineral-insulated (MI) cable connectors and EPAs made of crystallized glass-ceramic combined with superalloys. The EPAs have a maintenance-free lifespan of over 60 years, preventing any outage time related to these components and subsequently reducing costs associated with shutdowns. They are far more robust than organic seals and provide increased safety at a lower lifetime cost. Resistance against high pressure and high temperature are especially ideal qualities that make EPAs a valuable choice for environments with high standards for fire protection, such as nuclear plants, subsea oil drilling, or any other underwater application. Due to their significant offering of safety-relevant qualities, the EPAs have also been chosen by BWXT for implementation in its mPower SMR. Small modular reactor requirements are complex and very challenging but are met by the new EPA components, which will help form a strong I and C safety chain. Unlike ordinary compression glass-to-metal seals, GTMS with crystallized glass-ceramic have the ability to withstand temperatures of over 350 deg. C / 662 deg. F and operating pressures of 3500 bar. Furthermore, their lifetime is qualified for up to 60 years, including pressure and radiation requirements in accordance with the latest IEC/IEEE standards. Higher-specification EPAs and MI cable connectors have been designed into severe accident I and C instruments, including advanced hydrogen and oxygen sensors that exceed the challenging requirements of both HTR and SMR applications. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Penetration Electric Fields and Inner Magnetosphere Dynamics: A Model and Data Comparison

Significant progress has been made on the analysis of the June, 1991 storm. We have completed the analysis of the CRRES and DMSP data sets. We have been able to follow the evolution during the storm of the inner edge of the electric field patterns in the dusk sector and its relation to electron boundaries, ion boundaries and the ring current. Whereas the CRRES data provide radial cuts out through the plasmasphere every I 0 hours, DMSP provides snapshots every orbit of the potential and particle boundaries. Electric field and energetic particle measurements from CRRES and ion drifts and energetic particle measurements from DMSP provide the principal data sets. The combined data set provides high resolution definition of the boundary motions over the phases of the storm. L shell differences between the DMSP and CRRES particle boundaries are easily explained by inflation of the dusk sector by the ring current. The electric field boundaries are typically associated with the ion boundary and the inner edge of the ring current except during rapid increases in the cross-polar cap potential. A significant fraction of the dusk cell potential is found inside the plasmasheet electron inner edge. Twice during the storm this potential exceeded 60 kV. A paper (copy attached) has been prepared (Burke et al., 1998) and submitted to JGR. An invited paper will be presented by Burke at the spring AGU meeting. An abstract has also been submitted to the COSPAR meeting for presentation by Maynard. New simulations have been carried out with the Rice Convection Model for the magnetic storm of June 4-5, 1991, and comparisons have been made with CRRES and DMSP data.

Maynard, Nelson C.↗

Renewable Electricity Futures Study. Volume 1: Exploration of High-Penetration Renewable Electricity Futures

The Renewable Electricity Futures (RE Futures) Study investigated the challenges and impacts of achieving very high renewable electricity generation levels in the contiguous United States by 2050. The analysis focused on the sufficiency of the geographically diverse U.S. renewable resources to meet electricity demand over future decades, the hourly operational characteristics of the U.S. grid with high levels of variable wind and solar generation, and the potential implications of deploying high levels of renewables in the future. RE Futures focused on technical aspects of high penetration of renewable electricity; it did not focus on how to achieve such a future through policy or other measures. Given the inherent uncertainties involved with analyzing alternative long-term energy futures as well as the multiple pathways that might be taken to achieve higher levels of renewable electricity supply, RE Futures explored a range of scenarios to investigate and compare the impacts of renewable electricity penetration levels (30%-90%), future technology performance improvements, potential constraints to renewable electricity development, and future electricity demand growth assumptions. RE Futures was led by the National Renewable Energy Laboratory (NREL) and the Massachusetts Institute of Technology (MIT).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Renewable Electricity Futures Study - Volume 1: Exploration of High-Penetration Renewable Electricity Futures

The Renewable Electricity Futures (RE Futures) Study investigated the challenges and impacts of achieving very high renewable electricity generation levels in the contiguous United States by 2050. The analysis focused on the sufficiency of the geographically diverse U.S. renewable resources to meet electricity demand over future decades, the hourly operational characteristics of the U.S. grid with high levels of variable wind and solar generation, and the potential implications of deploying high levels of renewables in the future. RE Futures focused on technical aspects of high penetration of renewable electricity; it did not focus on how to achieve such a future through policy or other measures. Given the inherent uncertainties involved with analyzing alternative long-term energy futures as well as the multiple pathways that might be taken to achieve higher levels of renewable electricity supply, RE Futures explored a range of scenarios to investigate and compare the impacts of renewable electricity penetration levels (30%–90%), future technology performance improvements, potential constraints to renewable electricity development, and future electricity demand growth assumptions. RE Futures was led by the National Renewable Energy Laboratory (NREL) and the Massachusetts Institute of Technology (MIT). Learn more at the RE Futures website. http://www.nrel.gov/analysis/re_futures/

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Negative ion production and beam extraction processes in a large ion source (invited)

Recent research results on negative-ion-rich plasmas in a large negative ion source have been reviewed. Spatial density and flow distributions of negative hydrogen ions (H{sup −}) and positive hydrogen ions together with those of electrons are investigated with a 4-pin probe and a photodetachment (PD) signal of a Langmuir probe. The PD signal is converted to local H{sup −} density from signal calibration to a scanning cavity ring down PD measurement. Introduction of Cs changes the slope of plasma potential local distribution depending upon the plasma grid bias. A higher electron density H{sub 2} plasma locally shields the bias potential and behaves like a metallic free electron gas. On the other hand, the bias and extraction electric fields penetrate in a Cs-seeded electronegative plasma even when the electron density is similar. Electrons are transported by the penetrated electric fields from the driver region along and across the filter and electron deflection magnetic fields. Plasma ions exhibited a completely different response against the penetration of electric fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electric Field Penetration in Au/Nb:SrTiO3 Schottky Junctions Probed by Bias-Dependent Internal Photoemission

Electric field penetration into the metallic side of a Schottky junction is in principle a universal phenomenon, the magnitude of which increases with the semiconductor permittivity. Here, we quantitatively probe this effect using bias-dependent internal photoemission spectroscopy at the Schottky junction between a large dielectric permittivity semiconductor SrTiO{sub 3} and gold. A clear linear reduction of the barrier height with increasing interface electric field was observed, highlighting the importance of field penetration into the gold. The interfacial permittivity of SrTiO{sub 3} at the interface is reduced from the bulk value, reflecting intrinsic suppression at the interface.

36 MATERIALS SCIENCE↗