Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical transmission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Electric transmission value and its drivers in United States power markets

Electric transmission infrastructure plays a vital role during extreme weather and supply disruptions and can enable low-cost electricity systems. This paper contributes to a more complete understanding of the value and cost-effectiveness of transmission, as well as barriers to its development. By studying wholesale energy market prices in the United States between 2012 and 2022, we find that additional transfer capacity between regions would have been especially valuable, with a median value of $116 million per GW per year. This capacity would often have provided balanced benefits to each region. The market value of transmission was highly influenced by a small fraction of time: 5% of hours typically captured at least 45% of the total value. These peak periods were primarily driven by unforeseen changes in conditions within one day of operations. Annualized transmission infrastructure cost estimates were lower than the average market value for most locations, including all links crossing regional seams, where the value-to-cost ratio was often greater than 4. This suggests that there are barriers to developing valuable grid infrastructure. These results complement forward-looking modeling studies and support efforts to improve modeling practices.

Energy economics↗

UAV Inspection of Electrical Transmission Infrastructure with Path Conformance Autonomy and Lidar-Based Geofences NASA Report on UTM Reference Mission Flights at Southern Company Flights November 2016

Flights at low altitudes in close proximity to electrical transmission infrastructure present serious navigational challenges: GPS and radio communication quality is variable and yet tight position control is needed to measure defects while avoiding collisions with ground structures. To advance unmanned aerial vehicle (UAV) navigation technology while accomplishing a task with economic and societal benefit, a high voltage electrical infrastructure inspection reference mission was designed. An integrated air-ground platform was developed for this mission and tested in two days of experimental flights to determine whether navigational augmentation was needed to successfully conduct a controlled inspection experiment. The airborne component of the platform was a multirotor UAV built from commercial off-the-shelf hardware and software, and the ground component was a commercial laptop running open source software. A compact ultraviolet sensor mounted on the UAV can locate 'hot spots' (potential failure points in the electric grid), so long as the UAV flight path adequately samples the airspace near the power grid structures. To improve navigation, the platform was supplemented with two navigation technologies: lidar-to-polyhedron preflight processing for obstacle demarcation and inspection distance planning, and trajectory management software to enforce inspection standoff distance. Both navigation technologies were essential to obtaining useful results from the hot spot sensor in this obstacle-rich, low-altitude airspace. Because the electrical grid extends into crowded airspaces, the UAV position was tracked with NASA unmanned aerial system traffic management (UTM) technology. The following results were obtained: (1) Inspection of high-voltage electrical transmission infrastructure to locate 'hot spots' of ultraviolet emission requires navigation methods that are not broadly available and are not needed at higher altitude flights above ground structures. (2) The sensing capability of a novel airborne UV detector was verified with a standard ground-based instrument. Flights with this sensor showed that UAV measurement operations and recording methods are viable. With improved sensor range, UAVs equipped with compact UV sensors could serve as the detection elements in a self-diagnosing power grid. (3) Simplification of rich lidar maps to polyhedral obstacle maps reduces data volume by orders of magnitude, so that computation with the resultant maps in real time is possible. This enables real-time obstacle avoidance autonomy. Stable navigation may be feasible in the GPS-deprived environment near transmission lines by a UAV that senses ground structures and compares them to these simplified maps. (4) A new, formally verified path conformance software system that runs onboard a UAV was demonstrated in flight for the first time. It successfully maneuvered the aircraft after a sudden lateral perturbation that models a gust of wind, and processed lidar-derived polyhedral obstacle maps in real time. (5) Tracking of the UAV in the national airspace using the NASA UTM technology was a key safety component of this reference mission, since the flights were conducted beneath the landing approach to a heavily used runway. Comparison to autopilot tracking showed that UTM tracking accurately records the UAV position throughout the flight path.

Moore, Andrew J.↗

Component Assessment of the Electric Transmission Grid to Hurricanes

The increased frequency and intensity of extreme weather events from climate change necessitates understanding impacts on critical infrastructure, particularly electrical transmission grids. One of the foundational concepts of a grid's resilience is its robustness to extreme weather events, such as hurricanes. Resilience of the electric grid to high wind speeds is predicated upon the location and physical characteristics of the system components. Previous modeling assessments of electric grid failure were done at the systems level with assumptions on location and type of specific components. To facilitate more explicit adaptation metrics, accurate component-level information is needed. In this study, we build and utilize a data set of location, physical characteristics, and age of transmission structures for nine counties in the Florida Panhandle. These component characteristics were then simulated for failure under a variety of scenarios using fragility curves. Eight hurricanes were modeled using Hazus from the Federal Emergency Management Administration and the resulting impact to the network was assessed. The network was generated using the transmission lines and towers, showing increasing impacts to network efficiency with larger storms. Although modern transmission structures are built under the more stringent extreme wind loading construction standards, the prevalence of older, wooden transmission structures throughout the region poses a substantial risk to reliable electricity transmission during tropical cyclone events from the Gulf of Mexico.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrical Transmission on the Lunar Surface: DC Transmission - Part 1

This report summarizes a portion of the results from a grant at Auburn University to study the electrical and thermal energy management for lunar facilities. Over the past year (June 1989 to May 1990) the following topics have been investigated: June 1989 to November 1989 - Literature survey, assessment of lunar power needs, and overview study of the requirements of a lunar power system; November 1989 to April 1990 - Develop models for the study of dc electrical power transmission lines for the lunar surface; March 1990 to May 1990 - Develop models for the study of ac electrical power transmission lines for the lunar surface. Because of the large amount of information in the model development and application to a wide parameter space this report is being bound separately. This report specifically contains the model development and parameter study for dc electrical power transmission lines. The end of the funding year (May 1990) will conclude with an annual report including the literature survey, the overview of the requirements of a lunar power system, and summaries of the dc and ac models of electrical transmission lines.

Gordon, Lloyd B.↗

Autonomous Inspection of Electrical Transmission Structures with Airborne UV Sensors and Automated Air Traffic Management

This report details test and measurement flights to demonstrate autonomous UAV (Unmanned Aerial Vehicle) inspection of high-voltage electrical transmission structures. A UAV built with commercial, off-the-shelf hardware and software, supplemented with custom sensors and logging software, measured ultraviolet (UV) emissions from a test generator placed on a low-altitude substation and a medium-altitude switching tower. Since corona discharge precedes catastrophic electrical faults on high-voltage structures, detection and geolocation of ultraviolet emissions is needed to develop a UAV-based self-diagnosing power grid. Signal readings from an onboard ultraviolet sensor were validated during flight with a commercial corona camera. Geolocation was accomplished with onboard GPS; the UAV position was logged to a local ground station and transmitted in real time to a NASA server for tracking in the national airspace. The method has practicality and relevance but not adequacy; either improved UAV position determination technology or increased sensor range is needed to enable broad deployment of this method.

Moore, Andrew J.↗

Autonomous Inspection of Electrical Transmission Structures with Airborne UV Sensors - NASA Report on Dominion Virginia Power Flights of November 2016

The report details test and measurement flights to demonstrate autonomous UAV inspection of high voltage electrical transmission structures. A UAV built with commercial, off-the-shelf hardware and software, supplemented with custom sensor logging software, measured ultraviolet emissions from a test generator placed on a low-altitude substation and a medium-altitude switching tower. Since corona discharge precedes catastrophic electrical faults on high-voltage structures, detection and geolocation of ultraviolet emissions is needed to develop a UAV-based self-diagnosing power grid. Signal readings from an onboard ultraviolet sensor were validated during flight with a commercial corona camera. Geolocation was accomplished with onboard GPS; the UAV position was logged to a local ground station and transmitted in real time to a NASA server for tracking in the national airspace.

Moore, Andrew J.↗

Joint Planning of Electricity Transmission and Hydrogen Transportation Networks

The abundance and uneven distribution of renewable energy might cause congestion and curtailment in electric power systems. Transmission expansions can potentially alleviate transmission congestion and reduce renewable energy curtailment. On the other hand, with the substantial cost reduction of electrolyzer technology and the continuing rise of hydrogen demand, converting surplus renewable energy to hydrogen provides synergistic benefits to power and hydrogen systems, but consequently requires joint planning of the two systems. To this end, we propose a joint planning approach for power transmission and hydrogen transportation networks to coordinately optimize the investment and operation of power and hydrogen infrastructure. In our proposed model, detailed truck routing, pipeline, and hydrogen storage are formulated to quantify the flexibility of hydrogen transportation system. A robust joint planning approach is also proposed to address various uncertainties from renewable energy, electric load, and hydrogen demand. Furthermore, our numerical simulations show that the proposed joint planning model can save the total system cost, reduce renewable energy curtailment, and increase the utilization level of transmission lines.

08 HYDROGEN↗

A study of electric transmission lines for use on the lunar surface

The sources for electrical power on a lunar base are said to include solar/chemical, nuclear (static conversion), and nuclear (dynamic conversion). The transmission of power via transmission lines is more practical than power beaming or superconducting because of its low cost and reliable, proven technology. Transmission lines must have minimum mass, maximum efficiency, and the ability to operate reliably in the lunar environment. The transmission line design includes conductor material, insulator material, conductor geometry, conductor configuration, line location, waveform, phase selection, and frequency. This presentation oulines the design. Liquid and gaseous dielectrics are undesirable for long term use in the lunar vacuum due to a high probability of loss. Thus, insulation for high voltage transmission line will most likely be solid dielectric or vacuum insulation.

Gaustad, Krista L.↗

Interregional Electricity Transmission in the United States: Realized Savings and Opportunities for Increased Value, 2014 to 2023

Interregional electricity trade in the United States reduces total energy costs, but falls short of maximizing the economic potential of existing transmission infrastructure. This analysis of thirty-two U.S. electricity system interfaces crossing grid or market seams finds an average achieved cost savings of at least $1,226 million per year. This positive impact is offset by an average annual cost of uneconomic interchange of $551 million. Additional value of at least $238 million per year could be enabled by increasing utilization. Notably, uneconomic flows and low utilization rates can persist even when the price spread between regions is large. These conclusions are derived from historical (2014–2023) data on the magnitude and direction of interregional price spreads, the magnitude and direction of net energy transfers, and how these variables coincide, but do not account for all system constraints. These findings motivate the development and deployment of solutions that improve interregional transmission operations, in parallel with robust transmission infrastructure planning. JEL Classification: Q40 Energy: General

Q40 Energy: General↗

Current Best Practices on Wildfire Risk Reduction for Electric Transmission and Distribution Systems

This report provides a set of best practices in response to Section 4(d) of Executive Order 14308, Empowering Commonsense Wildfire Prevention and Response. The information contained herein is expected to be used in conjunction with other materials at the Federal Energy Regulatory Commission Wildfire Risk Mitigation Technical Conference (Docket No. AD25-16-000), with possible direction to the North American Electric Reliability Corporation to take action. The objective of this report is to provide an overview of existing and emerging best practices currently employed or planned by utilities for wildfire mitigation, demonstrating how these efforts align with the executive order’s emphasis on reducing electric utility–caused wildfires while also balancing cost-effectiveness. Additionally, while most practices in utility-developed wildfire mitigation plans focus on risk reduction through robustness and operational reliability, this report also discusses best practices for resilience. The best practices are adopted from publicly available utility wildfire mitigation plans from the United States and Canada, recent findings from wildfire risk reduction research, and industry engagement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary assessment of the tradeoffs between the electric motor and the transmission in electric vehicles

The efficiency, weight, and cost of various propulsion system for 4-passenger electric vehicles are compared. These systems comprise the electric motor and the required speed reducing transmission to obtain the appropriate speed at the wheel. Three types of motors, dc synchronous, and squirrel-cage were considered at 6000 ycm and 24 000 rpm for a peak power of 40 kW. Two types of gearing selected were a single speed differential and a differential with a differential with a 4-speed gearbox. Only components that were readily realizable within present state-of-the-art were considered.

Levi, E.↗

Electricity Subsector Transmission Resilience Maturity Model (TRMM) User Guide

The electric transmission sector is facing a range of threats to its functionality that are either new, more severe than experienced in earlier years, or more well understood. Such threats include more frequent and more severe extreme weather events, wildfires, droughts, and human-caused physical and cyberattacks. They also include geological, electromagnetic, and biological events. The novelty or increasing severity of these threats creates a significant need for transmission owners to implement programs to prevent, prepare for, respond to, and recover from such incidents. The national and economic security of the United States depends on the reliable functioning of the Nation’s critical infrastructure in the face of such threats, and the transmission networks are essential components of that infrastructure. The Electricity Subsector Transmission Resilience Maturity Model (TRMM) is a tool that a transmission organization can use to objectively evaluate and benchmark its currently established transmission resilience strategies, programs, policies, and investments, in order to target and prioritize enhancements where needed. The TRMM was developed to address the unique characteristics of the transmission system. The model can enable users to: • evaluate and benchmark their organization’s resilience capabilities, effectively and consistently • prioritize actions and investments to improve the resilience of their systems • share transmission-related knowledge, best practices, and relevant references within their organization and with business partners as a means to improve resilience capabilities • contribute to increasing the overall resilience of the Nation’s transmission systems. The TRMM provides descriptive rather than prescriptive industry-focused guidance. The model content is presented at a high level of abstraction so that it can be interpreted by transmission organizations of various types, structures, and sizes. The model is designed to an be easy-to-use, self-assessment tool.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A study of electric power transmission lines for use on the lunar surface

Analytical models have been developed to study the operating characteristics of electrical transmission lines for use on the lunar surface. Important design considerations for a transmission line operating on the lunar surface are mass, temperature, and efficiency. Transmission line parameters which impact these considerations include voltage, power loss, and waveform. The electrical and thermal models developed are used to calculate transmission line mass, size, and temperature as a function of voltage, geometry, waveform, location, and efficiency. The analyses include ac and dc for above and below ground operation. Geometries studied include a vacuum-insulated, two-wire transmission line and a solid-dielectric insulated, coaxial transmission line. A brief discussion of design considerations and the models developed is followed by results for parameter studies for both dc and ac transmission lines.

Gordon, Lloyd B.↗

Common Electric Power Transmission System Model JSON Schema Specification

The Common Electric Power Transmission System Model (CTM) is an intuitive, extensible, language-agnostic, and error-resistant specification of electric power network components parameter names and units, and relation between components, intended for use by the research community developing new computational methods for power systems operations and simulation. Power system datasets following the CTM specification can be read as dictionaries and manipulated in that form in most programming languages (e.g., Python, Julia, C++). This standard data structure in CTM makes it easy to work in multiple power systems domains (e.g., economic operation, reliability assessment, electricity markets, stability assessment, etc.) without requiring conversions between use-case-specific file formats with information loss in the process. This repository specifies CTM as a JSON Schema, provides documentation, derivate (code-generated) implementations of CTM, and example data and usage of the schema for important use cases.

Aravena Solis, Ignacio↗

Electrical signal transmission in a bone cell network: the influence of a discrete gap junction

A refined electrical cable model is formulated to investigate the role of a discrete gap junction in the intracellular transmission of electrical signals in an electrically coupled system of osteocytes and osteoblasts in an osteon. The model also examines the influence of the ratio q between the membrane's electrical time constant and the characteristic time of pore fluid pressure, the circular, cylindrical geometry of the osteon, and key simplifying assumptions in our earlier continuous cable model (see Zhang, D., S. C. Cowin, and S. Weinbaum. Electrical signal transmission and gap junction regulation in a bone cell network: A cable model for an osteon. Ann. Biomed. Eng. 25:379-396, 1997). Using this refined model, it is shown that (1) the intracellular potential amplitude at the osteoblastic end of the osteonal cable retains the character of a combination of a low-pass and a high-pass filter as the corner frequency varies in the physiological range; (2) the presence of a discrete gap junction near a resting osteoblast can lead to significant modulation of the intracellular potential and current in the osteoblast for measured values of the gap junction coupling strength; and (3) the circular, cylindrical geometry of the osteon is well simulated by the beam analogy used in Zhang et al.

Non-NASA Center↗