Search NASA⌕ Search

SEARCH · Search NASA

Results for “electricity savings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Potential reduction of DSN uplink energy cost

DSN Earth stations typically transmit more power than that required to meet minimum specifications for uplink performance. Energy and cost savings that could result from matching the uplink power to the amount required for specified performance are studied. The Galileo mission was selected as a case study. Although substantial reduction in transmitted energy is possible, potential savings in source energy (oil or electricity) savings are much less. This is because of the rising inefficiency in power conversion and radio frequency power generation that accompanies reduced power output.

Dolinsky, S.↗

Critical Care Dialysis System

Organon Teknika Corporation's REDY 2000 dialysis machine employs technology originally developed under NASA contract by Marquardt Corporation. The chemical process developed during the project could be applied to removing toxic waste from used dialysis fluid. This discovery led to the development of a kidney dialysis machine using "sorbent" dialysis, a method of removing urea from human blood by treating a dialysate solution. The process saves electricity and, because the need for a continuous water supply is eliminated, the patient has greater freedom.

Source record↗

Electrical Monitoring Devices Save on Time and Cost

In order to protect the Solar Dynamics Observatory's instruments from blowing their fuses and being rendered unusable, Goddard Space Flight Center worked with Micropac Industries Inc., based in Garland, Texas, to develop solid-state power controllers, which can depower and then resupply power to an instrument in the event of an electric surge. The company is now selling the technology for use in industrial plants.

Source record↗

Use of composites in electric vehicles

Report presents study of weight savings in electric vehicles by using alternative structural materials, particularly composites. Topics discussed include safety, aerodynamics, esthetics, and cost.

Dawe, R. H.↗

Differential Temperature Control of Electrical Heaters

Energy savings realized from heaters that maintain low humidity in electrical equipment. Unit applies power to electrical-equipment heater only when equipment temperature drops below preset differential above ambient. With differential controller, power consumed only 118 kWh for savings of 410 kWh/day, or 77-percent energy savings.

Cole, K. N.↗

Analysis of Hybrid Electric Aircraft Operations in the National Airspace System

This paper investigates the fuel burn and flight time impacts of hybrid electric aircraft operating in the National Airspace System. Future scenarios with hybrid electric flights and the same passenger travel capacity between city pairs as a baseline scenario, taken from historical data, were created. Aircraft that serviced select flights in the baseline scenario were replaced with hybrid electric aircraft based on the flight’s range and seat capacity. Additional hybrid electric flights were added to future scenarios when necessary to keep the future scenario passenger capacity equal or greater to that of the baseline scenario. The baseline and future scenarios were simulated in the NAS Digital Twin, a live, virtual, and constructive environment for building and executing simulations of the Nation Airspace System. Results showed that the future scenarios with hybrid electric flights saved fuel burn, but increased flight time. In the future scenarios, the additional hybrid electric flights did not cause any airports to exceed their operational capacity.

Simulation↗

Operating Hybrid Electric Aircraft in the National Airspace System

This paper investigates the fuel burn and flight time impacts of hybrid electric aircraft operating in the National Airspace System. Future scenarios with hybrid electric flights and the same passenger travel capacity between city pairs as a baseline scenario, taken from historical data, were created. Aircraft that serviced select flights in the baseline scenario were replaced with hybrid electric aircraft based on the flight’s range and seat capacity. Additional hybrid electric flights were added to future scenarios when necessary to keep the future scenario passenger capacity equal or greater to that of the baseline scenario. The baseline and future scenarios were simulated in the NAS Digital Twin, a live, virtual, and constructive environment for building and executing simulations of the Nation Airspace System. Results showed that the future scenarios with hybrid electric flights saved fuel burn, but increased flight time. In the future scenarios, the additional hybrid electric flights did not cause any airports to exceed their operational capacity.

hybrid electric aircraft↗

Power Switching Device

The MOS-Controlled Thyristor is a new type of power switching device for faster and more efficient control and management of power electronics. It enables power electronic switching at frequencies of 50 to 100 thousand times a second with much lower power losses than other semiconductor devices. Advantages include electric power savings and smaller space. The device is used in motor and power controllers, AC & DC motor drives and induction heating. Early development was supported by Lewis Research Center (LEW) and other agencies. General Electric''s power semiconductor operation, the initial NASA contractor, was later purchased by Harris Semiconductor.

Source record↗

Solar-energy-system performance evaluation: Honeywell OTS 44, Ocmulgee, Georgia

The operation and technical performance of the solar operational test site (OTS 44) are described, based on data collected between April, 1981 and August, 1981. The following topics are discussed: system description, performance assessment, operating energy, energy savings, system maintenance, and conclusions. The solar energy system at OTS 44 is a hydronic heating and cooling system consisting of 5040 square feet of liquid cooled flat plate collectors; a 4000 gallon thermal storage tank; one 25 ton capacity organic Rankine cycle engine assisted water chillers; a forced draft cooling tower; and associated piping, pumps, valves, controls and heat rejection equipment. The solar system has eight basic modes of operation and several combination modes for providing space conditioning and hot water to the building. Data monitored during the 4 months of the operational test period found that the solar system collected 285 MMBtu of thermal energy of the total incident solar energy of 1040 MMBtu and provided 210 MMBtu for cooling and 10 MMBtu for heating and hot water. The net electrical energy saving due to the solar system was approximately 2600 kWh(e), and fossil energy saving was about 20 million Btu (MMBtu).

Mathur, A. K.↗

Controllable Multi-Functional Heat Exchanger for Space Applications

Team Spacering will design SpaceRing, a cooling and waste heat recycling system that addresses NASA’s interest for a cooling and power-generating unit in its prototype deep space habitat[1]. The merits of this system are as follows: - Controllable cooling is critical in maintaining a habitable environment and in the functionality of life support systems, powering electronics and other devices in a spacecraft. - Power is expensive to produce in a space environment. Converting wasted thermal energy into electricity will save energy and money for the space station. Space habitation is a highly complex endeavor. Consequently, the SpaceRing must adhere to additional constraints, which include: - Lack of natural fluid or gas convection due to micro-gravity environment - Limited range for heat source and cold sink temperature - Subject to high fluctuations of incoming thermal energy - Minimal weight due to the high cost of transporting items into space After consulting with NASA and experts in thermal studies, several design objectives were identified and are listed below in order of importance: - High cooling capacity - Reliable safety control and alert system - Maximization of energy generation from wasted heat - Optimization of cooling capability and power generation - Long operational life and minimization of maintenance In space, conventional cooling systems utilize passive heat pipe systems for small-scale heat rejection and pumped pipes with heat exchangers for large-scale heat rejection. Thermal power generation in space is mainly achieved by using thermoelectric material that produces electric energy from temperature differentials. We propose a design that combines cooling and thermoelectric power generation. Using a hot pipe connected to a heat source, a cold pipe connected to a radiator, a heat exchanger in contact with both pipes, and a pump in each pipe to move the fluid, we make an active cooling system. The thermoelectric material is inserted in the heat exchanger between the hot and cold pipes to extract energy from the maximum temperature difference coming from the two pipes. It also provides controllable cooling capacity through the use of the thermoelectric material as cooling modules. We have tested our system under target heat source and sink conditions and measured the temperatures and flow rates. Our preliminary results are promising, demonstrating the output of 25 Watts of power on average. We are in the process of running control tests to compare the heat transfer performance without the thermoelectric generators, which is vital in determining whether or not the generators introduce an unacceptable amount of thermal resistance. While some control tests have been run already, the results have been noisy. We have modified our testing environment and data acquisition methods to allow for simple comparison between the control test results and thermoelectric performance results. Lastly, we have modified the heat exchanger design slightly to include acrylic baffles. This will allow the heat to flow through the heat exchanger more efficiently. We have presented our preliminary results to NASA and will deliver the final product by the end of May 2014.

Lee Xiong↗

Evaluations of Space Shielding

A general method of evaluating the efficiency of space vehicle shielding is developed and used to compare various active and passive systems for protection against ionizing radiation. Available permanent magnets are found useless for active shielding, and combined active-passive systems in general are determined to be inefficient. On the other hand, evaluations show that active electrostatic shielding may have possibilities for weight savings if electrical conditions (presently unknown) are favorable therefor in space. Further, a positive potential improvement is calculated for an active shielding system which utilizes superconducting Nb3Sn to provide a confined magnetic flux to deflect incident charged particles; this potential points toward substantial reductions in shield weight for the protection of large vehicles from highly energetic particles. Recommendations are made for further research, particularly for flight experiments to measure directionality of solar flare protons.

SHIELDING↗

Study of a heat rejection system using capillary pumping

Results of an analytical study investigating the application of capillary pumping to the heat rejection loop of an advanced Rankine cycle power conversion system are presented. The feasibility of the concept of capillary pumping as an alternate to electromagnetic pumping is analytically demonstrated. Capillary pumping is shown to provide a potential for weight and electrical power saving and reliability through the use of redundant systems. A screen wick pump design with arterial feed lines was analytically developed. Advantages of this design are high thermodynamic and hydrodynamic efficiency, which provide a lightweight easily packaged system. Operational problems were identified which must be solved for successful application of capillary pumping. The most important are the development of start up and shutdown procedures, and development of a means of keeping noncondensibles from the system and of earth-bound testing procedures.

Neal, L. G.↗

Potential benefits of a ceramic thermal barrier coating on large power generation gas turbine

Thermal barrier coating design option offers benefit in terms of reduced electricity costs when used in utility gas turbines. Options considered include: increased firing temperature, increased component life, reduced cooling air requirements, and increased corrosion resistance (resulting in increased tolerance for dirty fuels). Performance and cost data were obtained. Simple, recuperated and combined cycle applications were considered, and distillate and residual fuels were assumed. The results indicate that thermal barrier coatings could produce large electricity cost savings if these coatings permit turbine operation with residual fuels at distillate-rated firing temperatures. The results also show that increased turbine inlet temperature can result in substantial savings in fuel and capital costs.

Clark, J. S.↗

Solar energy system performance evaluation: Seasonal report for Elcam Tempe Arizona State University, Tempe, Arizona

The solar system, Elcam-Tempe, was designed by Elcam Incorporated, Santa Barbara, California, to supply commercial domestic hot water heating systems to the Agriculture Department residence at Arizona State University. The building is a single story residence located at the agriculture experiment farm of the Arizona State University. The energy system's four modes of operation are described. Electrical energy savings at the site was a net of 5.54 million Btu after the 0.17 million Btu of operating energy required to operate collector loop circulating pump were subtracted. The energy savings due to solar was less than the system's potential. On an average, twice as much hot water could have been used with significant solar energy contribution. The system corrosion and deposits caused by using dissimilar metals in the collector loop was the only problem noted with the Elcam-Tempe system.

Source record↗

Solar energy system performance evaluation: Seasonal report for Contemporary Newman, Newman, Georgia

A hot solar heating and hot water system's operational performance from June 1979 through April 1980 is evaluated. Solar energy satisfied 42 percent of the total measure load (hot water plus space heating), which was somewhat higher than the solar fraction of 32 percent. When system losses into the heating space from duct leaks and storage are included, the heating solar fraction increases from 42 to 64 percent. Net electrical energy savings were 5.47 million BTUs.

Source record↗

Solar energy system performance evaluation. Seasonal report for Wormser, Columbia, South Carolina

The Wormser Solar Energy System's operational performance from April 1979 through March 1980 was evaluated. The space heating subsystem met 42 percent of the measured space heating load and the hot water subsystem met 23 percent of the measured hot water demand. Net electrical energy savings were 4.36 million Btu's or 1277 kwh. Fossil energy savings will increase considerably if the uncontrolled solar energy input to the building is considered.

Source record↗

An analytical optimization of electric propulsion orbit transfer vehicles

Due to the electric propulsion's inherent propellant mass savings over chemical propulsion, electric propulsion orbit transfer vehicles (EPOTV's) are highly efficient mode of orbit transfer. When selecting an electric propulsion device (ion, MPD, or arcjet) and propellant for a particular mission, it is preferable to use quick, analytical system optimization methods instead of time intensive numerical integration methods. It is also of interest to determine each thruster's optimal operating characteristics for a specific mission. Analytical expressions are derived which determine the optimal specific impulse (Isp) for each type of electric thruster to maximize payload fraction for a desired thrusting time. These expressions take into account the variation of thruster efficiency with specific impulse. Verification of the method is made with representative electric propulsion values on a LEO-to-GEO mission. Application of the method to specific missions is discussed.

Oleson, Steven R.↗