Search NASA⌕ Search

SEARCH · Search NASA

Results for “electricity savings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Cost of Saving Electricity: A Multi-Program Cost Curve for Programs Funded by U.S. Utility Customers

This study analyzed the cost performance of electricity efficiency programs implemented by 116 investor-owned utilities between 2009 and 2015 in 41 states, representing about three-quarters of the total spending on U.S. efficiency programs. We applied our typology to characterize efficiency programs along several dimensions (market sector, technology, delivery approach, and intervention strategy) and report the costs incurred by utilities and other program administrators to achieve electricity savings as a result of the programs. Such cost performance data can be used to compare relative costs of different types of efficiency programs, evaluate efficiency options alongside other electricity resources, benchmark local efficiency programs against regional and national cost estimates, and assess the costs of meeting state efficiency policies. The savings-weighted average cost of saved electricity for the period was $0.025/kilowatt-hour (kWh). The cost of saved electricity for programs that targeted residential customers was $0.021/kWh, compared to $0.025/kWh for programs for commercial and industrial customers. Ultimately, we developed an aggregate program savings “cost curve” for the actual electricity efficiency resource during the period that provides insights into the relative costs of various types of efficiency programs and the savings contribution of each program type to the efficiency resource at a national level.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Estimating the Drivers of the Cost of Saved Electricity in Utility Customer-Funded Energy Efficiency Programs

Energy efficiency programs funded by utility customers provide an electricity resource in most U.S. states, but their scale and cost of saving electricity varies significantly by state. In this paper, we explore the drivers of the cost of saved electricity in these programs with an econometric model and nearly a decade of data reported by efficiency program administrators. We found strong evidence for economies of scale and weak evidence for diseconomies of scale, which suggests that states with low levels of efficiency savings relative to retail sales can increase the size of their efficiency programs without large increases to the cost of saved electricity. We discuss examples of energy efficiency forecasting and potential modeling in light our econometric analysis and identify methodological improvements relevant to utilities and grid operators. This paper provides insights into the economics of customer-funded efficiency programs that will support regulators, utilities, and policymakers to utilize energy efficiency as a resource.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Timed to save: the added value of accounting for hourly incidence of electricity savings from residential space-conditioning measures

Abstract Previous research has recognized that the value of measures that reduce electricity usage depends upon the timing of the savings generated, but the lack of hourly savings shapes has limited the demonstration of this concept. We develop empirical hourly savings shapes for residential space-conditioning measures from nearly 18,000 efficiency projects in California and show how they combine with the diurnal and seasonal variation in electricity system costs. We find that these measures (cooling replacements; windows, doors, and skylights; and other envelope measures) tend to save electricity when system costs are highest and that the hourly savings account for 1.4–1.5 times as much value as non-time-sensitive estimates of efficiency would predict. We present these impact multipliers for each measure to quantify the additional value revealed by the time-sensitive approach. We show that this additional value is similar in an evolving electricity grid with storage, rather than natural gas generation, as the marginal resource.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Regional difference and related cooling electricity savings of air pollutant affected natural ventilation in commercial buildings across the US

Maintaining indoor air pollutants under acceptable levels is significant to protect occupants from exposure to excessive air pollutants in natural ventilation. In this paper, using the representative air pollutant concentration data, we present the natural ventilation usability with associated cooling energy saving potentials in different location settings (urban and city center, suburban and rural) of the US under the influence of local weather conditions and major outdoor air pollutants, i.e. PM2.5, PM10 and ozone. It is found that the impacts of air pollutants on natural ventilation are usually higher in urban/suburban areas than rural areas (up to 25% difference) with the PM2.5 being the most significant outdoor air pollutant affecting natural ventilation usage. Furthermore, ozone could become increasingly influential on natural ventilation as moving from urban to suburban/rural areas. As to the cooling energy saving considering the impacts of outdoor air pollutants, natural ventilation is estimated to save approximately 10%–40% cooling energy (800–2600 kWh per small commercial building) annually in different location settings of investigated areas across the US. The following economic analysis demonstrates that these electricity savings lead to approximately 80–540 dollars annual savings of building operation cost per building. If the time of use rate is adopted, these cost savings could further increase by approximately 20% (Los Angeles) to more than 50% (Albuquerque) depending on different rate structures, which further demonstrates the potential of adopting natural ventilation as a sustainability measurement with benefits for building owners without compromising occupants health.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Miscellaneous Electric Loads: Characterization and Energy Savings Potential

Over time, miscellaneous electric loads (MELs) are expected to increase both in magnitude and share of residential and commercial building energy consumption. This trend is most apparent in North America, but it is also occurring in Japan and Europe. However, the contribution of MELs to building energy use is not currently well understood, both because the products in this category are transforming rapidly and the definition and classification of MELs is ambiguous. This study estimated the national energy consumption of 36 MELs using best-available data and found them to comprise 12% of delivered electricity to the U.S. residential and commercial building sectors. If 26 of these MELs were replaced with the most energy-efficient product models available on the market, their energy consumption could be halved to 6% of delivered electricity. National energy models will better account for building energy consumption by incorporating the MELs data collected and analyzed for this study, leading to improved policy decisions.

Miscellaneous electric loads, Plug loads, Taxonomy↗

Deep Reinforcement Learning Based Smart Water Heater Control for Reducing Electricity Consumption and Carbon Emission

Water heating is the third largest electricity consumer in U.S. households, after space heating and cooling. Thus, water heaters represent a significant potential for reducing electricity consumption and associated CO2 emissions of residential buildings. To this end, this study proposes a model-free deep reinforcement learning (RL) approach that aims to minimize the electricity consumption and the CO2 emissions of a heat pump water heater without affecting user comfort. In this approach, a set of RL agents focusing on either electricity saving or emission reduction, with different look ahead periods, were trained using the deep Q-networks (DQN) algorithm and their performance was tested on different hot water usage and Marginal Operating Emissions Rate (MOER) profiles. The testing results showed that the RL agents that focus on electricity saving can save electricity in the range of 12–22% by operating the water heater with maximum heat pump efficiency and minimum electric element utilization. On the other hand, the RL agents that focus on emission reduction reduced emissions in the range of 18–37% by making use of the variable MOER values. These RL agents used the heat pump and/or an element when the MOER values are low due to the availability of renewable energy sources (e.g., solar and wind) and mostly avoided the periods of carbon-intensive periods. Overall, these results showed that the proposed RL approach can help minimize the electricity consumption and the CO2 emissions of a heat pump water heater without having any prior knowledge about the device.

Amasyali, Kadir↗

Reinforcement-Learning-Based Smart Water Heater Control: An Actual Deployment

Utilizing smart control algorithms for electric water heaters (EWHs) is essential for fully harnessing the demand response (DR) potential of EWHs. For this reason, the use of reinforcement learning (RL) algorithms for EWHs has received increasing attention in recent years. However, existing RL approaches are either simulation-based or use pretrained RL agents. To this end, this paper presents the real-world deployment of a set of model-free RL approaches that aim to minimize the electricity cost of a EWH under a time-of-use electricity pricing policy using standard DR commands (e.g., shed, load up). The experiment results showed that the RL agents can help save electricity cost in the range of 11% to 14% compared to the baseline operation. This study demonstrated that RL-based EWH controllers can be deployed in real world without any prior training and can still save electricity cost.

deep learning↗

Backup power or bill savings? How electricity tariffs impact residential solar-plus-storage usage in the United States

Adoption of paired solar-plus-storage systems has accelerated in recent years, driven by both the demand for backup power and a desire to manage utility bills. Tradeoffs between those two uses can arise through the reserve setting on the battery storage system, which serves to maintain a minimum state of charge in case of a power interruption. Our paper applies an economic framework to evaluate this tradeoff in terms of changes in bill savings and customer reliability value across reserve levels, considering how those tradeoffs depend on the underlying electricity rate structure and levels. The analysis is based on a representative set of load profiles, solar profiles, tariff designs, and stochastic power interruption events across ten different regions in the United States. We find that the opportunity cost of holding storage capacity in reserve, in terms of foregone bill reductions, outweighs any gains in reliability value from mitigated power interruptions in the majority of customer situations. Higher storage reserve levels increase total customer value only in specific circumstances, such as for customers with inferior reliability (10x average interruptions), with a very high value of lost load ($50/kWh), and with tariff or interconnection rules that disallow grid charging. However, even this result is dampened when considering tariff designs with higher price differentials that increase the opportunity cost of holding storage in reserve (e.g. import/export or time-of-use rates). Allowing grid charging in tariffs essentially eliminates the necessity to hold any storage in reserve in all sensitivity cases explored.

Electric resilience↗

Optimized Gear Selection to Maximize Energy Savings in Electric Traction Drives for Medium and Heavy Duty Vehicles

Multi‑gear transmission systems are commonly used in electric traction drives for medium and heavy‑duty vehicles, while most passenger‑vehicle electric drivetrains rely on a single fixed ratio to reduce cost, weight, and complexity. Using multiple gear ratios can enable downsizing of the motor and inverter while still meeting performance requirements. Additionally, appropriately chosen ratios allow the motor to operate more frequently in high‑efficiency regions, improving overall energy usage and reducing operating costs over the drive cycle. This paper presents a systematic approach for selecting optimal gear ratios for electric drive systems. A neural‑network model is first developed to represent motor losses across the full torque–speed range using data generated from finite element analysis. This model enables fast, accurate evaluation of motor efficiency under varying operating conditions. A genetic‑algorithm‑based optimization framework is then applied to identify gear ratios that maximize energy cost savings over the drive cycle, with the resulting optimal ratios stored for real‑time implementation.

Gadiyar, Nishanth [ORNL] (ORCID:0000000348267524)↗

A hierarchical framework for aggregating grid-interactive buildings with thermal and battery energy storage

The behind-the-meter (BTM) thermal and battery energy storage can help improve energy efficiency, reduce energy costs, and enhance energy resilience, particularly in rural areas and for disadvantaged communities. Aggregating numerous BTM energy storage systems can act as a price influencer with a significant source of load shifting and peak demand reduction. An integrated and scalable control mechanism is required to effectively utilize energy storage systems and flexible building loads to maximize the economic benefits, considering various distribution system constraints. Here, this paper presents an innovative hierarchical coordination framework for energy storage and flexible load in buildings, considering various factors such as electricity prices, thermal comfort, and distribution system modeling and constraints. At the upper level, a distribution system operator optimizes the power flow to minimize its power procurement costs from the electricity wholesale market, while at the lower level, aggregators determine the optimal dispatch of battery and thermal energy storage systems in multiple buildings on behalf of end-users to minimize operating costs according to the power prices. These problems are solved using a game-theoretic approach through negotiations between the distribution system operator and aggregators as a bi-level decision model. Simulation case studies have been performed for a test distribution network with a number of building end-users using energy storage systems to quantify the performance of aggregators. The results demonstrate that the proposed strategy can reduce peak load for a reliable electricity distribution network while saving electricity bills for customers.

25 ENERGY STORAGE↗

Coupling thermal energy storage with a thermally anisotropic building envelope for building demand-side management across various US climate conditions

Here, the thermally anisotropic building envelope (TABE) is a novel active building envelope that enhances energy efficiency and thermal comfort in buildings by transferring heat and cold between building envelopes and hydronic loops. When coupled with thermal energy storage (TES) units, the TABE + TES enables the storage of both heat and cold energy captured by the TABE roof or exterior walls. This stored energy can be later released by the TABE floor for indoor heating and cooling, benefiting both the grid and the end user. This paper evaluates the merits of TABE + TES for building demand-side management across various US climate conditions, focusing on peak load shaving, annual energy savings, and cost savings under time-of-use (TOU) electric rate schedules. Simulations were conducted by integrating time-of-day–informed, rule-based control strategies in MATLAB, TABE components and TES units in COMSOL Multiphysics, and whole-building energy analysis in EnergyPlus. A case study using the US Department of Energy’s prototype single-family detached house model in Birmingham, Alabama; Los Angeles, California; Oak Ridge, Tennessee; and Denver, Colorado, showed that the TABE + TES system achieved (1) 70 % peak load shaving in Los Angeles and Denver and 20 % in Birmingham and Oak Ridge; (2) significant peak electricity savings of 351–497 kWh, reducing peak energy consumption by 38 %–78 %; and (3) annual heating cost savings of 0.79 $\$$/m2–1.17 $\$$/m 2 and cooling cost savings of 0.60 $\$$/m 2 –1.17 $\$$/m 2 using a normal utility rate or low-TOU rate. The benefits of employing the TABE + TES system are even more significant under high TOU rates.

25 ENERGY STORAGE↗

Integration of Solid Oxide Fuel Cell Systems Into Artificial Intelligence Data Centers

This report presents the results of a techno-economic analysis (TEA) that evaluates the economic benefits of integrating solid oxide fuel cell (SOFC) systems with artificial intelligence (AI) data centers. The analysis was completed in two phases: a scoping-level analysis was performed to identify impactful integration opportunities, followed by a more detailed TEA. Results show that, due to their modularity, SOFC can meet the 99.999% availability requirement of data centers with minimal additional costs. Heat integration via absorption chillers decreases data center electricity consumption at the tradeoff of increased water consumption. Higher SOFC exhaust temperatures are important for achieving larger electricity savings. Finally, power electronics integration with SOFC direct current electricity can reduce electricity consumption by 9 percent and reduce water consumption by 6.4 percent.

20 FOSSIL-FUELED POWER PLANTS↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma: Preprint

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of a conceptual microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗

Economic, Exergy, and Environmental Analyses of the Energy Assessments for U.S. Industries

Abstract This paper highlights the expected versus actual outcomes of 152 energy assessments that were performed between 2011 and 2020. The 1317 energy-assessment recommendations (ARs) are grouped into eight categories. This study adopted four measures per each category of recommendations: annual electricity savings, annual gas savings, annual cost savings, and annual CO2 emission reduction. The first part of the analysis compares the expected to the actually implemented values of the measures applied to each recommendation’s category. It was found that the percentages of the actual to the expected electricity, gas, and cost savings are 26.6%, 11.4%, and 17.1%, respectively, while the percentage of the actual to the expected CO2 reduction is 22%. Moreover, the second part of the analysis presents each category's implementation rate and the reasons for rejecting the unimplemented ARs. Cash flow and expensive initial investment resulted in rejecting 25% of ARs. Furthermore, the study proposes techniques and strategies to increase ARs’ implementation rate and improve private energy services companies’ implementation rate. Finally, exergy analysis is added to show the improvement that energy assessment achieves regarding exergy and exergy efficiencies of different industrial applications.

Energy & Fuels↗

Cross-cutting strategies to lower electricity use of miscellaneous electric loads in the domestic sector

Miscellaneous Electric Loads (MELs) account for roughly one quarter of building electricity use in most developed countries. A product-specific approach to lowering MELs electricity use in this category takes too long and costs too much because there are so many MELs, each providing unique services. An alternative approach focusing on key functionalities was therefore explored. These functionalities include: (1) power management, (2) power scaling, and (3) power conversion. Cross-cutting efficiency improvements to these functionalities can be incorporated into broad categories of MELs, thus saving electricity and lowering costs. Even though the population of MELs is diverse and rapidly evolving, major technical opportunities exist to improve their efficiency in these functionalities. Research into energy-saving solutions within the cross-cutting technologies will probably have larger savings than focusing on single products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multifold Insights for Power System Dynamics From Data Assimilation: Meeting Current Challenges

The world’s electric power grids have evolved over the last 120 years from a single power line to today’s large networks. The evolution will continue at an accelerated rate with extensive smart grid development worldwide. Here for example, the U.S. government has set a goal of reaching 100 percent carbon pollution-free electricity by 2035, while the Department of Energy (DOE) shared a goal to deploy 30 GW and 110 GW of offshore wind by 2030 and 2050, respectively. To meet such ambitious goals, in the years to come, a significant percentage of electricity will come from intermittent renewable sources, electric vehicles (EVs), and be supplied to a vast number of loads that will actively respond to grid conditions and incentive signals. This development is largely driven by environmental and economic factors, such as reducing carbon emissions and saving electricity cost for consumers. These energy resources lead to new uncertain behaviors and dynamics which the grid has never seen and were not considered in its design. Operating such a dynamic grid with sufficient reliability and efficiency is a monumental challenge.

24 POWER TRANSMISSION AND DISTRIBUTION↗