Search NASA⌕ Search

SEARCH · Search NASA

Results for “electro-osmosis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Chaotic micromixer utilizing electro-osmosis and induced charge electro-osmosis in eccentric annulus

Efficient mixing is of significant importance in numerous chemical and biomedical applications but difficult to realize rapidly in microgeometries due to the lack of turbulence. We propose to enhance mixing by introducing Lagrangian chaos through electro-osmosis (EO) or induced charge electro-osmosis (ICEO) in an eccentric annulus. The analysis reveals that the created Lagrangian chaos can achieve a homogeneous mixing much more rapidly than either the pure EO or the pure ICEO. Our systematic investigations on the key parameters, ranging from the eccentricity, the alternating time period, the number of flow patterns in one time period, to the specific flow patterns utilized for the Lagrangian chaos creation, present that the Lagrangian chaos is considerably robust. The system can obtain a good mixing effect with wide ranges of eccentricity, alternating time period, and specific flow patterns utilized for the Lagrangian chaos creation as long as the number of flow patterns in one time period is two. As the electric field increases, the time consumption for homogenous mixing is reduced more remarkably for the Lagrangian chaos of the ICEO than that of the EO.

42 ENGINEERING↗

Transient electro-osmosis in capillary tubes.

Transient electro-osmosis of water in capillary tubes for pumping and generation modes, analyzing response to step change in pressure or voltage change under external loading

Hanna, W. T.↗

Polymer Coatings Reduce Electro-osmosis

Poly(ethylene glycol) film controls electrostatic potential. Electro-osmosis in quartz or glass chambers reduced or reversed by coating inside surface of chambers with monomacromolecular layers of poly(ethylene glycol). Stable over long times. Electrostatic potential across surface of untreated glass or plastic chamber used in electro-phoresis is negative and attracts cations in aqueous electrolyte. Cations solvated, entrains flow of electrolyte migrating toward cathode. Electro-osmotic flow interferes with desired electrophoresis of particles suspended in electrolyte. Polymer coats nontoxic, transparent, and neutral, advantageous for use in electrophoresis.

Herren, Blair J.↗

Enhanced electro-osmosis in propylene carbonate salt solutions

Properties of solid–liquid interfaces and surface charge characteristics mediate ionic and molecular transport through porous systems, affecting many processes such as separations. Herein, we report experiments designed to probe the electrochemical properties of solid–liquid interfaces using a model system of a single polyethylene terephthalate (PET) pore in contact with aqueous and propylene carbonate solutions of LiClO 4 . First, the existence and polarity of surface charges were inferred from current–voltage curves recorded when a pore was placed in contact with a LiClO4 concentration gradient. Second, the electro-osmotic transport of uncharged polystyrene particles through the PET pore provided information on the polarity and the magnitude of the pore walls’ zeta potential. Our experiments show that the PET pores become effectively positively charged when in contact with LiClO 4 solutions in propylene carbonate, even though in aqueous LiClO 4 , the same pores are negatively charged. Additionally, the electro-osmotic velocity of the particles revealed a significantly higher magnitude of the positive zeta potential of the pores in propylene carbonate compared to the magnitude of the negative zeta potential in water. The presented methods of probing the properties of solid–liquid interfaces are expected to be applicable to a wide variety of solid and liquid systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compensating for Electro-Osmosis in Electrophoresis

Simple mechanical adjustment eliminates transverse velocity component. New apparatus for moving-wall electrophoresis increases degree of collimation of chemical species in sample stream. Electrophoresis chamber set at slight angle in horizontal plane to adjust angle between solution flow and wall motion. Component of velocity created cancels electro-osmotic effect.

Rhodes, Percy H.↗

Modeling electrokinetic flows with the discrete ion stochastic continuum overdamped solvent algorithm

In this article we develop an algorithm for the efficient simulation of electrolytes in the presence of physical boundaries. In previous work the discrete ion stochastic continuum overdamped solvent (DISCOS) algorithm was derived for triply periodic domains, and was validated through ion-ion pair correlation functions and Debye-Hückel-Onsager theory for conductivity, including the Wien effect for strong electric fields. In extending this approach to include an accurate treatment of physical boundaries we must address several important issues. First, the modifications to the spreading and interpolation operators necessary to incorporate interactions of the ions with the boundary are described. Next we discuss the modifications to the electrostatic solver to handle the influence of charges near either a fixed potential or dielectric boundary. An additional short-ranged potential is also introduced to represent interaction of the ions with a solid wall. Finally, the dry diffusion term is modified to account for the reduced mobility of ions near a boundary, which introduces an additional stochastic drift correction. Herein, several validation tests are presented confirming the correct equilibrium distribution of ions in a channel. Additionally, the methodology is demonstrated using electro-osmosis and induced-charge electro-osmosis, with comparison made to theory and other numerical methods. Notably, the DISCOS approach achieves greater accuracy than a continuum electrostatic simulation method. We also examine the effect of under-resolving hydrodynamic effects using a “dry diffusion” approach, and find that considerable computational speedup can be achieved with a negligible impact on accuracy.

97 MATHEMATICS AND COMPUTING↗

Rotating Apparatus for Isoelectric Focusing

Remixing of separated fractions prevented. Improved isoelectric focusing apparatus helps to prevent electro-osmosis and convection, both of which cause remixing of separated fractions. Fractionating column segmented and rotated about horizontal axis: Only combined effects of both features fully effective in making good separations. Improved apparatus slowly rotated continuously or rocked (at rotational amplitude of at least 180 degrees) about its horizontal axis so average gravitational vector experienced by fluid is zero and convection is therefore suppressed. Electro-osmosis suppressed and convection further suppressed by separating column into disklike compartments along its length with filters. Experiments have shown dimensions of apparatus not critical. Typical compartment and column volumes are 2 and 40 ml, respectively. Rotation speeds lie between 3 and 30 rpm.

Bier, M.↗

Liquid Crystals-Enabled AC Electrokinetics

Phenomena of electrically driven fluid flows, known as electro-osmosis, and particle transport in a liquid electrolyte, known as electrophoresis, collectively form a subject of electrokinetics. Electrokinetics shows a great potential in microscopic manipulation of matter for various scientific and technological applications. Electrokinetics is usually studied for isotropic electrolytes. Recently it has been demonstrated that replacement of an isotropic electrolyte with an anisotropic, or liquid crystal (LC), electrolyte, brings about entirely new mechanisms of spatial charge formation and electrokinetic effects. This review presents the main features of liquid crystal-enabled electrokinetics (LCEK) rooted in the field-assisted separation of electric charges at deformations of the director that describes local molecular orientation of the LC. Since the electric field separates the charges and then drives the charges, the resulting electro-osmotic and electrophoretic velocities grow as the square of the applied electric field. We describe a number of related phenomena, such as alternating current (AC) LC-enabled electrophoresis of colloidal solid particles and fluid droplets in uniform and spatially-patterned LCs, swarming of colloids guided by photoactivated surface patterns, control of LCEK polarity through the material properties of the LC electrolyte, LCEK-assisted mixing at microscale, separation and sorting of small particles. LC-enabled electrokinetics brings a new dimension to our ability to manipulate dynamics of matter at small scales and holds a major promise for future technologies of microfluidics, pumping, mixing, sensing, and diagnostics.

47 OTHER INSTRUMENTATION↗

A reactive electrochemomechanical theory for growth and remodeling of polyelectrolyte hydrogels and application to dynamic polymerization of $\text{DNA}$ hydrogels

Here this study develops a framework for growth and remodeling of active polyelectrolyte hydrogels that accounts for effects of compositional changes on the mechanical response. By developing a reactive electrochemomechanical theory, thermodynamical constraints upon reactive and remodeling processes are elucidated within a general framework that allows any number of chemical reactions to evolve the response of the gel and transfer mass and charge between constituents. Fully coupled, nonlinear constitutive relations are adopted for molar fluxes, allowing exploration of effects including cross-diffusion, electrophoresis, and electro-osmosis. A robust finite element implementation is developed in the open source FEBio software (febio.org) by exploiting an equivalence between electrochemomechanics and mixture theory. The implementation is verified against analytical solutions for free swelling, and a proper reduction to a prior chemomechanical theory is demonstrated for neutral gels swollen only by a solvent with no solutes. The theory and implementation are then applied to model the tunable large swelling achieved through dynamic polymerization of DNA crosslinkers seen in our recently developed experimental hydrogel system (Cangialosi et al., 2017). A novel constitutive model for reaction-driven evolution of the locking stretch λ L in a non-Gaussian mechanical free energy was developed, where the increasing concentration of DNA crosslinkers makes further swelling energetically favorable. With a single free parameter, excellent agreement was found between measured and predicted equilibrium swelling ratios. This study demonstrated the ability to extend the electrochemomechanical framework to include chemical reactions and composition-aware constitutive models, and showed that development of reactive models allows simulation of complex dynamic polymerization phenomena not treated before. The theoretical frame here can be further expanded in scope to incorporate additional non-ideal and nonlinear phenomena.

42 ENGINEERING↗

A resettable in-line particle concentrator using AC electrokinetics for distributed monitoring of microalgae in source waters

Green algae have been studied as an important and effective biomarker to indicate water quality due to their sensitivity to toxic agents in freshwater sources. But, conventional methods to monitor algal physiology use a chlorophyll fluorometer whose use is hampered by high-cost, large footprint, and limited sensitivity for practical samples containing low algal concentration. In order to overcome these constraints, we developed a multi-level electrode platform for resettable trapping of algae via AC electro-osmosis (ACEO) and negative dielectrophoresis. Preliminary experiments were performed in freshwater with conductivity of 0.02 S/m. Algal trapping was demonstrated at a low voltage of 2 V. The concentration effect was experimentally verified by measuring the fluorescence intensity of algae and using hemocytometer counting chambers at the inlet and outlet of the multilevel microchannel lab-on-a-chip. An optimal frequency was found for trapping, which agrees with the frequency dependence of ACEO flow velocity. Through-flow rate and electrode dimensions were optimized as well. Trapping efficiencies within the range of 26% - 65% have been obtained. A maximum trapping rate of 182 cells/s was obtained with a flow rate of 20 l/min. Our lab-on-a-chip shows high potential for improving the limit of detection in algal monitoring and enabling the development of a portable, integrated and automated system for monitoring the quality of source drinking waters.

30 DIRECT ENERGY CONVERSION↗

Stable metal battery anodes enabled by polyethylenimine sponge hosts by way of electrokinetic effects

The cycle life and energy density of rechargeable metal batteries are largely limited by the dendritic growth of their metal anodes (lithium, sodium or zinc). Here we develop a three-dimensional cross-linked polyethylenimine lithium-ion-affinity sponge as the lithium metal anode host to mitigate the problem. We show that electrokinetic surface conduction and electro-osmosis within the high-zeta-potential sponge change the concentration and current density profiles, which enables dendrite-free plating/stripping of lithium with a high Coulombic efficiency at high deposition capacities and current densities, even at low temperatures. The use of a lithium-hosting sponge leads to a significantly improved cycling stability of lithium metal batteries with a limited amount of lithium (for example, the areal lithium ratio of negative to positive electrodes is 0.6) at a commercial-level areal capacity. We also observed dendrite-free morphology in sodium and zinc anodes, which indicates a broader promise of this approach.

25 ENERGY STORAGE↗

Key parameters controlling the performance of catalytic motors

The development of autonomous micro/nanomotors driven by self-generated chemical gradients is a topic of high interest given their potential impact in medicine and environmental remediation. Although impressive functionalities of these devices have been demonstrated, a detailed understanding of the propulsion mechanism is still lacking. In this work, we perform a comprehensive numerical analysis of the key parameters governing the actuation of bimetallic catalytic micropumps. We show that the fluid motion is driven by self-generated electro-osmosis where the electric field originates by a proton current rather than by a lateral charge asymmetry inside the double layer. Hence, the surface potential and the electric field are the key parameters for setting the pumping strength and directionality. The proton flux that generates the electric field stems from the proton gradient induced by the electrochemical reactions taken place at the pump. Surprisingly the electric field and consequently the fluid flow are mainly controlled by the ionic strength and not by the conductivity of the solution, as one could have expected. We have also analyzed the influence of the chemical fuel concentration, electrochemical reaction rates, and size of the metallic structures for an optimized pump performance. Our findings cast light on the complex chemomechanical actuation of catalytic motors and provide important clues for the search, design, and optimization of novel catalytic actuators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrochemical Measurement of Water Transport Numbers in Anion-Exchange Membranes

Anion-exchange membranes (AEMs) are a possible replacement for perfluorosulfonic-acid membranes in energy-conversion devices, primarily due to the hydroxide mobile ion allowing the devices to operate in alkaline conditions with less expensive electrocatalysts. However, the transport properties of AEMs remain understudied, especially electro-osmosis. In this work, an electrochemical technique, where the open-circuit voltage is measured between two ends of a membrane maintained at different relative humidities, is used to determine the water transport number of various ionomers, including Versogen and Sustainion AEMs and Nafion cation-exchange membrane (CEM), as a function of water content and temperature. In addition, the CEMs and AEMs are examined in differing single-ion forms, specifically proton and sodium (CEM) and hydroxide and carbonate (AEM). Carbonate-form AEMs have the highest transport number (∼11), followed by sodium-form CEMs (∼8), hydroxide-form AEMs (∼6), and proton-form CEMs (∼3). Finally, a multicomponent transport model based on the Stefan-Maxwell-Onsager framework of binary interactions is used to develop a link between water transport number and water-transport properties, extracting a range for the unmeasured membrane water permeability of Versogen as a function of water content.

30 DIRECT ENERGY CONVERSION↗

Electrophoresis demonstration on Apollo 16

Free fluid electrophoresis, a process used to separate particulate species according to surface charge, size, or shape was suggested as a promising technique to utilize the near zero gravity condition of space. Fluid electrophoresis on earth is disturbed by gravity-induced thermal convection and sedimentation. An apparatus was developed to demonstrate the principle and possible problems of electrophoresis on Apollo 14 and the separation boundary between red and blue dye was photographed in space. The basic operating elements of the Apollo 14 unit were used for a second flight demonstration on Apollo 16. Polystyrene latex particles of two different sizes were used to simulate the electrophoresis of large biological particles. The particle bands in space were extremely stable compared to ground operation because convection in the fluid was negligible. Electrophoresis of the polystyrene latex particle groups according to size was accomplished although electro-osmosis in the flight apparatus prevented the clear separation of two particle bands.

Snyder, R. S.↗

Annular-Cross-Section CFE Chamber

Proposed continuous-flow-electrophoresis (CFE) chamber of annular cross section offers advantages over conventional CFE chamber, and wedge-cross-section chamber described in "Increasing Sensitivity in Continuous-Flow Electrophoresis" (MFS-26176). In comparison with wedge-shaped chamber, chamber of annular cross section virtually eliminates such wall effects as electro-osmosis and transverse gradients of velocity. Sensitivity enhanced by incorporating gradient maker and radial (collateral) flow.

Sharnez, Rizwan↗

Techniques For Focusing In Zone Electrophoresis

In two techniques for focusing in zone electrophoresis, force of applied electrical field in each charged particle balanced by restoring force of electro-osmosis. Two techniques: velocity-gradient focusing (VGF), suitable for rectangular electrophoresis chambers; and field-gradient focusing (FGF), suitable for step-shaped electrophoresis chambers.

Sharnez, Rizwan↗

Sub-Grid Modeling of Electrokinetic Effects in Micro Flows

Advances in micro-fabrication processes have generated tremendous interests in miniaturizing chemical and biomedical analyses into integrated microsystems (Lab-on-Chip devices). To successfully design and operate the micro fluidics system, it is essential to understand the fundamental fluid flow phenomena when channel sizes are shrink to micron or even nano dimensions. One important phenomenon is the electro kinetic effect in micro/nano channels due to the existence of the electrical double layer (EDL) near a solid-liquid interface. Not only EDL is responsible for electro-osmosis pumping when an electric field parallel to the surface is imposed, EDL also causes extra flow resistance (the electro-viscous effect) and flow anomaly (such as early transition from laminar to turbulent flow) observed in pressure-driven microchannel flows. Modeling and simulation of electro-kinetic effects on micro flows poses significant numerical challenge due to the fact that the sizes of the double layer (10 nm up to microns) are very thin compared to channel width (can be up to 100 s of m). Since the typical thickness of the double layer is extremely small compared to the channel width, it would be computationally very costly to capture the velocity profile inside the double layer by placing sufficient number of grid cells in the layer to resolve the velocity changes, especially in complex, 3-d geometries. Existing approaches using "slip" wall velocity and augmented double layer are difficult to use when the flow geometry is complicated, e.g. flow in a T-junction, X-junction, etc. In order to overcome the difficulties arising from those two approaches, we have developed a sub-grid integration method to properly account for the physics of the double layer. The integration approach can be used on simple or complicated flow geometries. Resolution of the double layer is not needed in this approach, and the effects of the double layer can be accounted for at the same time. With this approach, the numeric grid size can be much larger than the thickness of double layer. Presented in this report are a description of the approach, methodology for implementation and several validation simulations for micro flows.

Chen, C. P.↗

Electrokinetic In Situ Treatment of Metal-Contaminated Soil

An electrokinetic technique has been developed as a means of in situ remediation of soils, sludges, and sediments that are contaminated with heavy metals. Examples of common metal contaminants that can be removed by this technique include cadmium, chromium, zinc, lead, mercury, and radionuclides. Some organic contaminants can also be removed by this technique. In the electrokinetic technique, a low-intensity direct current is applied between electrodes that have been implanted in the ground on each side of a contaminated soil mass. The electric current causes electro-osmosis and migration of ions, thereby moving aqueous-phase subsurface contaminants from one electrode to the other. The half reaction at the anode yields H+, thereby generating an acid front that travels from the anode toward the cathode. As this acid front passes through a given location, the local increase in acidity increases the solubility of cations that were previously adsorbed on soil particles. Ions are transported towards one electrode or the other which one depending on their respective electric charges. Upon arrival at the electrodes, the ionic contaminants can be allowed to become deposited on the electrodes or can be extracted to a recovery system. Surfactants and other reagents can be introduced at the electrodes to enhance rates of removal of contaminants. Placements of electrodes and concentrations and rates of pumping of reagents can be adjusted to maximize efficiency. The basic concept of electrokinetic treatment of soil is not new. What is new here are some of the details of application and the utilization of this technique as an alternative to other techniques (e.g., flushing or bioremediation) that are not suitable for treating soils of low hydraulic conductivity. Another novel aspect is the use of this technique as a less expensive alternative to excavation: The cost advantage over excavation is especially large in settings in which contaminated soil lies near and/or under industrial buildings and therefore excavation would be made even more expensive by the need to prevent damage to numerous underground pipes and cables.

Quinn, Jacqueline↗