Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrochemical mapping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Metabolic Vessel for Impedance Spectroscopy and Electrochemistry (MVISE): The Ground Mapping Unit for the Lunar Explorer Instrument for Space Biology Applications (LEIA)​

The BioSensor payload on the upcoming LEIA platform aboard a CLPS lander will carry yeast to the moon to study response to radiation and lunar gravity. The LEIA BioSensor is designed to monitor metabolic activity using absorbance in conjunction with alamarBlue for measuring colorimetric changes as proxy measurement for redox potential. The science data returned from small spacecraft mission modules like LEIA is limited as it relies solely on optical measurements, necessitating a corresponding ground mapping unit that is equipped with multiple electrochemical sensors for accurate mapping of the optical data and operates fully automatically. This technology development work discusses the extensive design and optimization efforts put into the ground mapping unit, MVISE. MVISE is a custom designed, 3D-printed vessel with an agitation system, with six different electrochemical sensor probes, and ports for sample collection and a pressure release valve. The sensors provide real-time data, with dry absorbance measurements aligning with LEIA flight hardware and wet measurements demonstrating invasive sensor design enabling a comparison between the two setups. The 3D printer resin was tested for mechanical robustness, biocompatibility, and resistance to autoclave sterilization. The inner walls were coated with food-grade epoxy, ensuring a smooth finish to prevent microbial lodging and dye staining. The MVISE has successfully passed a week-long leak test and is now undergoing active biology tests. The MVISE prototype will be prepared for radiation tests, with three identical units being tested for varying radiation levels and culture compositions at the NASA Space Radiation Laboratory in November 2024. The integrated sensor approach proposed in this work will enable the accurate mapping of the BioSentinel/LEIA optical flight data to six sensor parameters on the ground unit for better science data return and will enable the first effort to evaluate classical biochemical sensor measurements by comparing and contrasting their responses.

Chinmayee Govinda Raj↗

Mapping the Capabilities and Attributes of Solid Oxide Electrochemical Systems to Human Spaceflight Needs

NASA is sponsoring the development of a solid oxide electrochemical oxygen separation and compression system. This system is capable of extracting oxygen from a process stream of spacecraft cabin air, and compressing it to >27,000 kPa without mechanical compressors. Process temperatures are >650C, but the materials in contact with the oxygen do not burn. The system is called eCOG-C, Electrochemical Oxygen Generator and Compressor. A system capable of producing high pressure, high purity oxygen may have application as a method of recharging space suit oxygen tanks during human exploration missions. This paper describes the key performance parameters of a space suit oxygen tank recharge system, and places the key performance parameters of eCOG-c in the context of other methods of space suit oxygen tank recharge. This paper compares the eCOG-c configuration to an earlier electrochemical oxygen generator that has been prototyped and tested. Areas of emphasis for eCOG-C development are listed and described.

John Graf↗

Performance Mapping Studies in Redox Flow Cells

Pumping power requirements in any flow battery system constitute a direct parasitic energy loss. It is therefore useful to determine the practical lower limit for reactant flow rates. Through the use of a theoretical framework based on electrochemical first principles, two different experimental flow mapping techniques were developed to evaluate and compare electrodes as a function of flow rate. For the carbon felt electrodes presently used in NASA-Lewis Redox cells, a flow rate 1.5 times greater than the stoichiometric rate seems to be the required minimum.

Hoberecht, M. A.↗

NASA Tech Briefs, June 2006

Topics covered include: Magnetic-Field-Response Measurement-Acquisition System; Platform for Testing Robotic Vehicles on Simulated Terrain; Interferometer for Low-Uncertainty Vector Metrology; Rayleigh Scattering for Measuring Flow in a Nozzle Testing Facility; "Virtual Feel" Capaciflectors; FETs Based on Doped Polyaniline/Polyethylene Oxide Fibers; Miniature Housings for Electronics With Standard Interfaces; Integrated Modeling Environment; Modified Recursive Hierarchical Segmentation of Data; Sizing Structures and Predicting Weight of a Spacecraft; Stress Testing of Data-Communication Networks; Framework for Flexible Security in Group Communications; Software for Collaborative Use of Large Interactive Displays; Microsphere Insulation Panels; Single-Wall Carbon Nanotube Anodes for Lithium Cells; Tantalum-Based Ceramics for Refractory Composites; Integral Flexure Mounts for Metal Mirrors for Cryogenic Use; Templates for Fabricating Nanowire/Nanoconduit- Based Devices; Measuring Vapors To Monitor the State of Cure of a Resin; Partial-Vacuum-Gasketed Electrochemical Corrosion Cell; Theodolite Ring Lights; Integrating Terrain Maps Into a Reactive Navigation Strategy; Reducing Centroid Error Through Model-Based Noise Reduction; Adaptive Modeling Language and Its Derivatives; Stable Satellite Orbits for Global Coverage of the Moon; and Low-Cost Propellant Launch From a Tethered Balloon

Source record↗

High resolution electrolyte for thinning InP by anodic dissolution and its applications to EC-V profiling, defect revealing and surface passivation

An extensive experimental study was conducted using various electrolytes in an effort to find an appropriate electrolyte for anodic dissolution of InP. From the analysis of electrochemical characteristics in the dark and under different illumination levels, x ray photoelectron spectroscopy and SEM/Nomarski inspection of the surfaces, it was determined that the anodic dissolution of InP front surface layers by FAP electrolyte is a very good choice for rendering smooth surfaces, free of oxides and contaminants and with good electrical characteristics. The FAP electrolyte, based on HF, CH3COOH, and H2O2 appears to be inherently superior to previously reported electrolytes for performing accurate EC-V profiling of InP at current densities of up to 0.3 mA/sq cm. It can also be used for accurate electrochemical revealing of either precipitates or dislocation density with application to EPD mapping as a function of depth, and for defect revealing of multilayer InP structures at any depth and/or at the interfaces.

Faur, Maria↗

Tracking Metabolic Changes in Microbial Culture using Redox Measurements

During long-term space missions, microbial cultures accumulate the effects of low-dose radiation, microgravity, and other factors; altered growth and metabolic activity may occur before viability effects. This could affect functionality of bioreactors or other bio-enabled mission systems, as well as shed light on human health. Spaceflight microbiology studies beyond the low Earth orbit exposure afforded by the ISS have been limited. Nanosatellites offer an increasingly popular alternative for deep space missions. However, the communications delay requires biofluidic automation of a pre-defined experimental protocol, and the lack of sample return (reliance on sensors in flight) can significantly limit feasible investigations. Previous biological CubeSats (PharmaSat, O/OREOS, EcAMSat) have used alamarBlue, an off-the-shelf formulation of the redox indicator dye resazurin, to track metabolic activity, as will BioSentinel, the upcoming interplanetary microbiology experiment. A series of ground experiments (see abstracts by Liddell, Santa Maria, and A. Kim) were conducted using a microbial culture system outfitted with an electrochemical sensor array (electrical conductivity, pH, oxidation-reduction potential, and dissolved oxygen) with alamarBlue and the same strain of Saccharomyces cerevisiae as BioSentinel. By improving mapping of measured changes in alamarBlue kinetics to physicochemical changes, and ultimately to biological alterations such as shifted metabolic pathways, this work supplements data analyses from past missions and planning for future missions using alamarBlue to characterize space radiation effects. Initial results indicate that alamarBlue acts like a redox buffer; its presence significantly changes redox kinetics in otherwise identical cultures. The initial color change (blue resazurin reduced to red/pink resorufin) appears as a redox plateau. A second plateau, likely corresponding to the second color transition (resorufin to the colorless hydroresorufin), occurs at a lower redox value. The relationship to carbon source exhaustion, dissolved oxygen depletion, cell death, and measured redox potential is complex and still under study.

Tracking↗

Investigations of Physical Processes in Microgravity Relevant to Space Electrochemical Power Systems

NASA has performed physical science microgravity flight experiments in the areas of combustion science, fluid physics, material science and fundamental physics research on the International Space Station (ISS) since 2001. The orbital conditions on the ISS provide an environment where gravity driven phenomena, such as buoyant convection, are nearly negligible. Gravity strongly affects fluid behavior by creating forces that drive motion, shape phase boundaries and compress gases. The need for a better understanding of fluid physics has created a vigorous, multidisciplinary research community whose ongoing vitality is marked by the continuous emergence of new fields in both basic and applied science. In particular, the low-gravity environment offers a unique opportunity for the study of fluid physics and transport phenomena that are very relevant to management of fluid - gas separations in fuel cell and electrolysis systems. Experiments conducted in space have yielded rich results. These results provided valuable insights into fundamental fluid and gas phase behavior that apply to space environments and could not be observed in Earth-based labs. As an example, recent capillary flow results have discovered both an unexpected sensitivity to symmetric geometries associated with fluid container shape, and identified key regime maps for design of corner or wedge-shaped passive gas-liquid phase separators. In this presentation we will also briefly review some of physical science related to flight experiments, such as boiling, that have applicability to electrochemical systems, along with ground-based (drop tower, low gravity aircraft) microgravity electrochemical research. These same buoyancy and interfacial phenomena effects will apply to electrochemical power and energy storage systems that perform two-phase separation, such as water-oxygen separation in life support electrolysis, and primary space power generation devices such as passive primary fuel cell.

energy storage↗

Ozone profile measurements at McMurdo Station Antarctica during the spring of 1987

During the Antarctic spring of 1986, 33 ozone soundings were conducted from McMurdo Station. These data indicated that the springtime decrease in ozone occurred rapidly between the altitudes of 12 and 20 km. During 1987, these measurements were repeated with 50 soundings between 29 August and 9 November. Digital conversions of standard electrochemical cell ozonesondes were again employed. The ozonesonde pumps were individually calibrated for flow rate as the high altitude performance of these pumps have been in question. While these uncertainties are not large in the region of the ozone hole, they are significant at high altitude and apparently resulted in an underestimate of total ozone of about 7 percent (average) as compared to the Total Ozone Mapping Spectrometer (TOMS) in 1986, when the flow rate recommended by the manufacturer was used. At the upper altitudes (approx. 30 km) the flow rate may be overestimated by as much as 15 percent using recommended values (see Harder et al., The UW Digital Ozonesonde: Characteristics and Flow Rate Calibration, poster paper, this workshop). These upper level values are used in the extrapolation, at constant mixing ratio, required to complete the sounding for total ozone. The first sounding was on 29 August, prior to major ozone depletion, when 274 DU total ozone (25 DU extrapolated) was observed. By early October total ozone had decreased to the 150 DU range; it then increased during mid-October owing to motion of the vortex and returned to a value of 148 DU (29 DU extrapolated) on 27 October.

Hofmann, D. J.↗

Detection of Intergranular Corrosion in Cold Plate Face Sheets

Cold plates are critical for cooling electronic systems in the shuttle. As a result of the environmental conditions in which they operate, water can condense between them and a support shelf. In some cases, this water results in intergranular corrosion in the face sheet. If the intergranular corrosion sufficiently penetrates the face sheet, a coolant leak could occur and jeopardize cold plate operation. This paper examines techniques for detecting and characterizing the intergranular corrosion, to enable recertification of cold plates that have been in operation for 15 plus years. Intergranular corrosion was artificially induced in the face sheets of a series of cold plate specimens using an electrochemical process. Some of the cold plate specimens were separated for destructive characterization of the extent of corrosion produced by the electrochemical process and to insure the induced corrosion was intergranular. The rest of the specimens were characterized nondestructively using several techniques. X-ray tomography and ultrasonic techniques provided the best indication of corrosion in these specimens and will be the focus of this paper. An x-ray tomography technique was shown to be the most effective technique for characterizing depth of the intergranular corrosion. From these measurements, corrosion profile maps were developed that were consistent with subsequent destructive evaluations of the specimens. This enabled the assessment of NDE (ondestructive evaluation) standards to evaluate the viability of other NDE techniques. Due to system constraints, a different technique must be used to inspect an entire cold plate. An ultrasonic technique was shown to be very reliable for detection of corrosion in the unbacked regions of the face sheet. The ultrasonic technique was performed in an alcohol bath to avoid additional corrosion during the NDE evaluation. A pulse echo technique that focuses on the RMS value of the signal is shown to be very sensitive to the presence of intergranular corrosion.

Winfree, William P.↗

NASA Tech Briefs, May 2007

Topics include: Noise-Canceling Helmet Audio System; Program Analyzes Spacecraft/Ground Radio Links; Two-Way Communication Using RFID Equipment and Techniques; Six-Message Electromechanical Display System; Scanning Terahertz Heterodyne Imaging Systems; Master Clock and Time-Signal-Distribution System; Synchronous Phase-Resolving Flash Range Imaging; Integrated Radial Probe Transition From MMIC to Waveguide; Bar-Code System for a Microbiological Laboratory; MMIC Amplifier Produces Gain of 10 dB at 235 GHz; Mapping Nearby Terrain in 3D by Use of a Grid of Laser Spots; Digital Beam Deflectors Based Partly on Liquid Crystals; Narrow-Band WGM Optical Filters With Tunable FSRs; Better Finite-Element Analysis of Composite Shell Structures; Computing Spacecraft-Pointing Vectors for Limb Tracking; Enhanced Master Controller Unit Tester; Rover Graphical Simulator; Increasing Durability of Flame-Sprayed Strain Gauges; Multifunctional, High-Temperature Nanocomposites; Multilayer Impregnated Fibrous Thermal Insulation Tiles; Radiation-Shielding Polymer/Soil Composites; Film/Adhesive Processing Module for Fiber-Placement Processing of Composites; Fabrication of Submillimeter Axisymmetric Optical Components; Electrochemical Disposal of Hydrazines in Water; Statistical Model of Evaporating Multicomponent Fuel Drops; Resistively Heated SiC Nozzle for Generating Molecular Beams; Compact Packaging of Photonic Millimeter-Wave Receiver; Diffractive Combiner of Single-Mode Pump Laser-Diode Beams; Wide-Band, High-Quantum-Efficiency Photodetector; A Robustly Stabilizing Model Predictive Control Algorithm; Modeling Evaporation of Drops of Different Kerosenes; Development of Vapor-Phase Catalytic Ammonia Removal System; Several Developments in Space Tethers; Design Concept for a Nuclear Reactor-Powered Mars Rover; Formation-Initialization Algorithm for N Spacecraft; and DNSs of Multicomponent Gaseous and Drop-Laden Mixing Layers Achieving Transition to Turbulence.

Source record↗

Manufacture and evaluation of Li/BCX DD cells

This project is divided into four main tasks: cell manufacture, acceptance, and lot certification of cells, performance testing of cells, and abuse testing of cells. Lithium/bromine chloride in thionyl chloride (Li/BCX) 149 DD cells (PN 3B2085-XA) were built according to the provisions of Electrochem Industries Quality Plan 17096. Acceptance and lot certification testing was performed according to NASA JSC Document EP5-83-025, Revision B. Acceptance testing included open circuit and load voltage check, visual examination, size and weight measurements, and high temperature exposure. Lot certification tests were performed for capacity performance and for performance under conditions of thermal and electrical abuse. These tests included 149 C exposure, capacity discharge, fuse check, high temperature exposure, high rate discharge, short circuit, vibration, and overdischarge testing. A quantity of 200 cells was delivered to Johnson Space Center for life test evaluation. A parametric evaluation of the capacity discharge of Li/BCX DD cells was performed over a variety of temperatures and discharge rates. This testing served to map the performance capability of the cell. Tests were also performed over a variety of electrical and thermal abuse conditions. Abuse tests included short circuit, charging, overdischarge, high temperature exposure, shock, and vibration.

Meyer, S.↗

High Temperature Protonic Conductors

High Temperature Protonic Conductors (HTPC) with the perovskite structure are envisioned for electrochemical membrane applications such as H2 separation, H2 sensors and fuel cells. Successive membrane commercialization is dependent upon addressing issues with H2 permeation rate and environmental stability with CO2 and H2O. HTPC membranes are conventionally fabricated by solid-state sintering. Grain boundaries and the presence of intergranular second phases reduce the proton mobility by orders of magnitude than the bulk crystalline grain. To enhanced protonic mobility, alternative processing routes were evaluated. A laser melt modulation (LMM) process was utilized to fabricate bulk samples, while pulsed laser deposition (PLD) was utilized to fabricate thin film membranes . Sr3Ca(1+x)Nb(2-x)O9 and SrCe(1-x)Y(x)O3 bulk samples were fabricated by LMM. Thin film BaCe(0.85)Y(0.15)O3 membranes were fabricated by PLD on porous substrates. Electron microscopy with chemical mapping was done to characterize the resultant microstructures. High temperature protonic conduction was measured by impedance spectroscopy in wet air or H2 environments. The results demonstrate the advantage of thin film membranes to thick membranes but also reveal the negative impact of defects or nanoscale domains on protonic conductivity.

Dynys, Fred↗

Ground-based intercomparisons of SBUV/2 flight instruments the world standard Dobson spectrophotometer 83 and overpass observations from Nimbus-7 TOMS and NOAA-11 SBUV/2

Total ozone data obtained during summers at Mauna Loa Observatory, Hawaii, with Dobson Spectrophotometer 83 are routinely compared with overpass total ozone data from the Total Ozone Mapping Spectrometer (TOMS) and the Solar Backscatter Ultraviolet (SBUV) spectrometer launched aboard the Nimbus 7 satellite in 1978. Results from the TOMS/Dobson instrument comparisons through 1990 have been presented by McPeters and Komhyr (1991). Dobson spectrophotometer 83 was established as the standard instrument for the U.S.A. Dobson instrument station network in 1962. In 1980, the instrument was designated by the World Meteorological Organization (WMO) as the Standard Dobson Spectrophotometer for the World. Long-term ozone measurement precision of the instrument has been maintained at plus or minus 0.5 percent (Komhyr et al., 1989). On an absolute scale, the ozone measurement accuracy of the instrument is estimated to plus or minus 3 percent. In early April, 1990, comparison of total ozone and vertical distribution (Umkehr) observations were made for the first time with Dobson spectrophotometer 8.3. The work was conducted at the NOAA Climate Monitoring and Diagnostics Laboratory (CMDL) in Boulder, Colorado, and at the research and instrument manufacturing facility of the Ball Aerospace System Division located about 2 km east of Boulder. (The SBUV-2 S/N-2 instrument, built by Ball Aerospace Systems Division, is scheduled for launch aboard the NOAA-13 satellite). We present results of the comparisons which include ozone vertical distribution data obtained with a balloon-borne electrochemical concentration cell (ECC) ozonesonde (Komhyr, 1969).

Heath, D. F.↗

NASA Tech Briefs, July 2007

Topics covered include: Miniature Intelligent Sensor Module; "Smart" Sensor Module; Portable Apparatus for Electrochemical Sensing of Ethylene; Increasing Linear Dynamic Range of a CMOS Image Sensor; Flight Qualified Micro Sun Sensor; Norbornene-Based Polymer Electrolytes for Lithium Cells; Making Single-Source Precursors of Ternary Semiconductors; Water-Free Proton-Conducting Membranes for Fuel Cells; Mo/Ti Diffusion Bonding for Making Thermoelectric Devices; Photodetectors on Coronagraph Mask for Pointing Control; High-Energy-Density, Low-Temperature Li/CFx Primary Cells; G4-FETs as Universal and Programmable Logic Gates; Fabrication of Buried Nanochannels From Nanowire Patterns; Diamond Smoothing Tools; Infrared Imaging System for Studying Brain Function; Rarefying Spectra of Whispering-Gallery-Mode Resonators; Large-Area Permanent-Magnet ECR Plasma Source; Slot-Antenna/Permanent-Magnet Device for Generating Plasma; Fiber-Optic Strain Gauge With High Resolution And Update Rate; Broadband Achromatic Telecentric Lens; Temperature-Corrected Model of Turbulence in Hot Jet Flows; Enhanced Elliptic Grid Generation; Automated Knowledge Discovery From Simulators; Electro-Optical Modulator Bias Control Using Bipolar Pulses; Generative Representations for Automated Design of Robots; Mars-Approach Navigation Using In Situ Orbiters; Efficient Optimization of Low-Thrust Spacecraft Trajectories; Cylindrical Asymmetrical Capacitors for Use in Outer Space; Protecting Against Faults in JPL Spacecraft; Algorithm Optimally Allocates Actuation of a Spacecraft; and Radar Interferometer for Topographic Mapping of Glaciers and Ice Sheets.

Source record↗

Remodeling BioSentinel’s Microbial Metabolism Measurement System

BioSentinel, the first biological CubeSat beyond low Earth orbit, will investigate how Saccharomyces cerevisiae responds to ionizing radiation using optical measurements of a colorimetric metabolic indicator dye (alamarBlue). To map optical data to more detailed metabolic measurements, a microbial culture system for ground testing was designed consisting of a 400 mL beaker and a rubber stopper with pass-through holes for its five sensor probes (electrical conductivity, pH, oxidation-reduction potential, dissolved oxygen, optical density). The initial design had several drawbacks. It was only partially reusable due to its one-time sealants: Teflon tape and parafilm. A steady increase in oxygen levels within the sensor’s testingdata indicated the design was not sufficiently airtight. Degradation of the rubber stopper’s elasticity due to sterilization and reinsertion of the probes led to poor robustness and eventual replacement. The vessel’s large headspace didn’t reproduce flight conditions and a large culture volume required more reagents. The system has been redesigned to contain a rigid, biocompatible polycarbonate disc lid that allows for threaded inserts. The culture vessel’s height will be reduced from 110 mm to 65 mm to decrease overhead space and material costs. A more reliable seal will be achieved with a gasket and clamps. The optical probe records absorbance at four wavelengths to characterize cell density and alamarBlue dye ratios. A pneumatically operated plunger draws media through the hollow interior of the probe. Currently, deformation of the silicone on the plunger causes asymmetrical movement and a drift from its initial state. Designs are being developed to limit the plunger’s travel for a more accurate measurement cycle. The remodeled system is under construction and will be tested for leaks and accuracy. The measurements collected will be used to provide additional insight into the optical data returned from the BioSentinel mission.

Astrobiology↗