Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrode package”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Durable, Ultra-Thin Diaphragms for Liquid Alkaline Water Electrolysis

W. L. Gore & Associates assembled a world class team (De Nora Tech, LLC; New York University; and thyssenkrupp nucera) to develop durable, ultra-low resistance diaphragms that dramatically improve system efficiency, dynamic response, and operational flexibility. To enable the use of ultra-thin diaphragms, an optimized electrode package was chosen as part of an electrode down select study. Ultra-thin diaphragms based on microporous polymer scaffolds imbibed with zirconia nanoparticles were developed and tested. Performance and durability on par with incumbent materials was demonstrated. A transparent electrolyzer to directly observe in-situ diaphragm-bubble interactions was designed and built, and simultaneous optical and electrochemical performance tests were performed. A Pressurized Alkaline Water Electrolysis (PAWE) single cell test station was designed to support advanced R&D in high-pressure electrolysis, particularly for evaluating novel electrode and separator configurations under elevated temperature and pressure operating conditions. Due to early project termination, the original scope could not be fully achieved.

08 HYDROGEN↗

Neuro-Prosthetic Implants With Adjustable Electrode Arrays

Brushlike arrays of electrodes packaged with application-specific integrated circuits (ASICs) are undergoing development for use as electronic implants especially as neuro-prosthetic devices that might be implanted in brains to detect weak electrical signals generated by neurons. These implants partly resemble the ones reported in Integrated Electrode Arrays for Neuro-Prosthetic Implants (NPO-21198), NASA Tech Briefs, Vol. 27, No. 2 (February 2003), page 48. The basic idea underlying both the present and previously reported implants is that the electrodes would pick up signals from neurons and the ASICs would amplify and otherwise preprocess the signals for monitoring by external equipment. The figure presents a simplified and partly schematic view of an implant according to the present concept. Whereas the electrodes in an implant according to the previously reported concept would be microscopic wires, the electrodes according to the present concept are in the form of microscopic needles. An even more important difference would be that, unlike the previously reported concept, the present concept calls for the inclusion of microelectromechanical actuators for adjusting the depth of penetration of the electrodes into brain tissue. The prototype implant now under construction includes an array of 100 electrodes and corresponding array of electrode contact pads formed on opposite faces of a plate fabricated by techniques that are established in the art of microelectromechanical systems (MEMS). A mixed-signal ASIC under construction at the time of reporting the information for this article will include 100 analog amplifier channels (one amplifier per electrode). On one face of the mixed-signal ASIC there will be a solder-bump/micro-pad array that will have the same pitch as that of the electrode array, and that will be used to make the electrical and mechanical connections between the electrode array and the ASIC. Once the electrode array and the ASIC are soldered together, the remaining empty space between them will be filled with a biocompatible epoxy, the remaining exposed portions of the ASIC will be covered with micromachined plates for protection against corrosive bodily fluids, and then the ASIC and its covering micromachined plates will be coated with parylene

Whitacre, Jay↗

Development of a large scale bipolar NiH2 battery

The bipolar battery concept, developed in cooperation with NASA, is described in the context of the advantages afforded by near-term IPV and CVP cell technology. The projected performance, development requirements, and a possible approach to bipolar battery design are outlined. Consideration is given to packaging electrodes within a common hydrophobic plastic frame, electrode technology that involves a photochemically etched 0.1 mm thick nickel substrate coated with a 10 mg/sq cm mixture of platinum powder and TFE30, and an electrode design that eliminates the screen and doubles the electrode thickness (from the currently used 0.8 mm) while retaining the active material loading of 1.6-1.8 gm/cu cm. Also covered are thermal management, and electrolyte and oxygen management. It is concluded that a high voltage, high capacity, bipolar NiH2 cell can be configured with proper development for use in large power systems, and that it can provide considerable weight savings.

Adler, E.↗

Investigations of Arcjet Flow Thermochemistry

An experimental and numerical investigation of the thermochemical state of arcjet flows is currently being conducted at NASA Ames Research Center. The experimental approach relies on the use of laser- and emission-spectroscopic diagnostic techniques in three regions of the flow. A fiber optic sensor is used to record spectrally resolved emission signals from the electrode package region, where the flow is most likely to be in thermochemical equilibrium. A second emission diagnostic measurement is made in the shock layer formed over a blunt-body test article placed in the stream, and a CCD camera is used to simultaneously record spectral emission from several measurement locations along the stagnation streamline. Downstream of the nozzle exit, but upstream of the test article, Laser-Induced Fluorescence (LIF) of atomic nitrogen is used to assess the nonequilibrium distribution of flow enthalpy in the free stream. Results from the measurements are compared with predictions from a two-temperature, axisymmetric flow model that solves the nozzle and shock-layer flows.

Fletcher, Douglas G.↗

Flip chip packaging of a MEMS neuro-prosthetic system

A joint research team from California Institute of Technology and Jet Propulsion Laboratory is developing a fully miniaturized, smart implantable neuro-prosthetic system, by combining integrated electronics with Micro Electro Mechanical Structure (MEMS) based electrode arrays. The packaging group of this project team has been tasked with designing and fabricating a package to interface electrically between a MEMS electrode array, capable of extracting signals from brain, and an electronic chip, capable of providing on chip conditioning/processing of extracted data, while delivering the output data to a detector located outside the body.

flip↗

Device and Container for Reheating and Sterilization

Long-duration space missions require the development of improved foods and novel packages that do not represent a significant disposal issue. In addition, it would also be desirable if rapid heating technologies could be used on Earth as well, to improve food quality during a sterilization process. For this purpose, a package equipped with electrodes was developed that will enable rapid reheating of contents via ohmic heating to serving temperature during space vehicle transit. Further, the package is designed with a resealing feature, which enables the package, once used, to contain and sterilize waste, including human waste for storage prior to jettison during a long-duration mission. Ohmic heating is a technology that has been investigated on and off for over a century. Literature indicates that foods processed by ohmic heating are of superior quality to their conventionally processed counterparts. This is due to the speed and uniformity of ohmic heating, which minimizes exposure of sensitive materials to high temperatures. In principle, the material may be heated rapidly to sterilization conditions, cooled rapidly, and stored. The ohmic heating device herein is incorporated within a package. While this by itself is not novel, a reusable feature also was developed with the intent that waste may be stored and re-sterilized within the packages. These would then serve a useful function after their use in food processing and storage. The enclosure should be designed to minimize mass (and for NASA's purposes, Equivalent System Mass, or ESM), while enabling the sterilization function. It should also be electrically insulating. For this reason, Ultem high-strength, machinable electrical insulator was used.

Sastry, Sudhir K.↗

High-Density, Actively Multiplexed µECoG Array on Reinforced Silicone Substrate

Simultaneous interrogation of electrical signals from wide areas of the brain is vital for neuroscience research and can aid in understanding the mechanisms of brain function and treatments for neurological disorders. There emerges a demand for development of devices with highly conformal interfaces that can span large cortical regions, have sufficient spatial resolution, and chronic recording capability while keeping a small implantation footprint. In this work, we have designed 61 channel and 48 channel high-density, cortical, micro-electrocorticographic electrode arrays with 400 µm pitch on an ultra-soft but durable substrate. We have also developed a custom multiplexing integrated circuit (IC), methods for packaging the IC in a water-tight liquid crystal polymer casing, and a micro-bonding method for attaching the electronics package to the electrode array. With the integrated multiplexer, the number of external wire connections can be reduced to 16 wires, thereby diminishing the invasive footprint of the device. Both the electrode array and IC were tested in vivo in a rat model to demonstrate the ability to sense finely-localized electrophysiological signals.

Rachinskiy, Iakov↗

Anisotropic Piezocomposite Actuator Incorporating Machined PMN-PT Single Crystal Fibers

The design, fabrication, and testing of a flexible, planar, anisotropic piezoelectric composite actuator utilizing machined PMN-32%PT single crystal fibers is presented. The device consists of a layer of rectangular single crystal piezoelectric fibers in an epoxy matrix, packaged between interdigitated electrode polyimide films. Quasistatic free-strain measurements of the single crystal device are compared with measurements from geometrically identical specimens incorporating polycrystalline PZT-5A and PZT-5H piezoceramic fibers. Free-strain actuation of the single crystal actuator at low bipolar electric fields (+/- 250 V/mm) is approximately 400% greater than that of the baseline PZT-5A piezoceramic device, and 200% greater than that of the PZT-5H device. Free-strain actuation under high unipolar electric fields (0-4kV/mm) is approximately 200% of the PZT-5A baseline device, and 150% of the PZT-5H alternate piezoceramic device. Performance increases at low field are qualitatively consistent with predicted increases based on scaling the low-field d(sub 33) piezoelectric constants of the respective piezoelectric materials. High-field increases are much less than scaled d(sub 33) estimates, but appear consistent with high-field freestrain measurements reported for similar bulk single-crystal and piezoceramic compositions. Measurements of single crystal actuator capacitance and coupling coefficient are also provided. These properties were poorly predicted using scaled bulk material dielectric and coupling coefficient data. Rules-of-mixtures calculations of the effective elastic properties of the single crystal device and estimated actuation work energy densities are also presented. Results indicate longitudinal stiffnesses significantly lower (50% less) than either piezoceramic device. This suggests that single-crystal piezocomposite actuators will be best suited to low induced-stress, high strain and deflection applications.

Wilkie, W. Keats↗

Anisotropic Laminar Piezocomposite Actuator Incorporating Machined PMN-PT Single Crystal Fibers

The design, fabrication, and testing of a flexible, laminar, anisotropic piezoelectric composite actuator utilizing machined PMN-32%PT single crystal fibers is presented. The device consists of a layer of rectangular single crystal piezoelectric fibers in an epoxy matrix, packaged between interdigitated electrode polyimide films. Quasistatic free-strain measurements of the single crystal device are compared with measurements from geometrically identical specimens incorporating polycrystalline PZT-5A and PZT-5H piezoceramic fibers. Free-strain actuation of the single crystal actuator at low bipolar electric fields (+/- 250 V/mm) is approximately 400% greater than that of the baseline PZT-5A piezoceramic device, and 200% greater than that of the PZT-5H device. Free-strain actuation under high unipolar electric fields (0-4kV/mm) is approximately 200% of the PZT-5A baseline device, and 150% of the PZT-5H alternate piezoceramic device. Performance increases at low field are qualitatively consistent with predicted increases based on scaling the low-field d33 piezoelectric constants of the respective piezoelectric materials. High-field increases are much less than scaled d33 estimates, but appear consistent with high-field freestrain measurements reported for similar bulk single-crystal and piezoceramic compositions. Measurements of single crystal actuator capacitance and coupling coefficient are also provided. These properties were poorly predicted using scaled bulk material dielectric and coupling coefficient data. Rules-of-mixtures calculations of the effective elastic properties of the single crystal device and estimated actuation work energy densities are also presented. Results indicate longitudinal stiffnesses significantly lower (50% less) than either piezoceramic device. This suggests that single-crystal piezocomposite actuators will be best suited to low induced-stress, high strain and deflection applications.

Wilkie, W. Keats↗

Semi-solid alkali metal electrodes enabling high critical current densities in solid electrolyte batteries

The need for higher energy density rechargeable batteries has generated interest in alkali metal electrodes paired with solid electrolytes. However, metal penetration and electrolyte fracture at low current densities have emerged as fundamental barriers. Here, we show that for pure metals in the Li-Na-K system, the critical current densities scale inversely to mechanical deformation resistance. Furthermore, we demonstrate two electrode architectures in which the presence of a liquid phase enables high current densities while preserving the shape retention and packaging advantages of solid electrodes. First, biphasic Na-K alloys show K + critical current densities (with K-β*-Al 2 O 3 electrolyte) that exceed 15 mA∙cm -2 . Second, introducing a wetting interfacial film of Na-K liquid between Li metal and Li 6.75 La 3 Zr 1.75 Ta 0.25 O 12 (LLZTO) solid electrolyte doubles the critical current density and permits cycling at areal capacities exceeding 3.5 mAh∙cm -2 . These design approaches hold promise for overcoming electro-chemo-mechanical stability issues that have heretofore limited performance of solid-state metal batteries.

25 ENERGY STORAGE↗

Rocket-borne time-of-flight mass spectrometry

Theoretical and numerical analyses are made of planar, cylindrical and spherical-electrode two-field time-of-flight mass spectrometers in order to optimize their operating conditions. A method is introduced which can improve the resolving power of these instruments by a factor of 7.5. Potential barrier gating in time-of-flight mass spectrometers is also analyzed. Experimental studies of a miniature cylindrical-electrode and a hemispherical-electrode time-of-flight mass spectrometer are presented. Their sensitivity and ability to operate at D-region pressures with an open source make them ideal instruments for D-region ion composition measurements. A sounding rocket experiment package carrying a cylindrical electrode time-of-flight mass spectrometer was launched. The data indicate that essentially 100% of the positive electric charge on positive ions is carried by ions with mass-to-charge ratios greater than 500 below an altitude of 92 km. These heavy charge carriers were present at altitudes up to about 100 km.

Reiter, R. F.↗

Integrated Electrode Arrays for Neuro-Prosthetic Implants

Arrays of electrodes integrated with chip-scale packages and silicon-based integrated circuits have been proposed for use as medical electronic implants, including neuro-prosthetic devices that might be implanted in brains of patients who suffer from strokes, spinal-cord injuries, or amyotrophic lateral sclerosis. The electrodes of such a device would pick up signals from neurons in the cerebral cortex, and the integrated circuit would perform acquisition and preprocessing of signal data. The output of the integrated circuit could be used to generate, for example, commands for a robotic arm. Electrode arrays capable of acquiring electrical signals from neurons already exist, but heretofore, there has been no convenient means to integrate these arrays with integrated-circuit chips. Such integration is needed in order to eliminate the need for the extensive cabling now used to pass neural signals to data-acquisition and -processing equipment outside the body. The proposed integration would enable progress toward neuro-prostheses that would be less restrictive of patients mobility. An array of electrodes would comprise a set of thin wires of suitable length and composition protruding from and supported by a fine-pitch micro-ball grid array or chip-scale package (see figure). The associated integrated circuit would be mounted on the package face opposite the probe face, using the solder bumps (the balls of the ball grid array) to make the electrical connections between the probes and the input terminals of the integrated circuit. The key innovation is the insertion of probe wires of the appropriate length and material into the solder bumps through a reflow process, thereby fixing the probes in place and electrically connecting them with the integrated circuit. The probes could be tailored to any distribution of lengths and made of any suitable metal that could be drawn into fine wires. Furthermore, the wires could be coated with an insulating layer using anodization or other processes, to achieve the correct electrical impedance. The probe wires and the packaging materials must be biocompatible using such materials as lead-free solders. For protection, the chip and package can be coated with parylene.

Brandon, Erik↗

Custom-form iron trifluoride Li-batteries using material extrusion and electrolyte exchanged ionogels

Custom-form factor batteries fabricated in non-conventional shapes can maximize the overall energy density of the systems they power, particularly when used in conjunction with energy dense materials (e.g., Li metal anodes and conversion cathodes). Additive manufacturing (AM), and specifically material extrusion (ME), have been shown as effective methods for producing custom-form cell components, particularly electrodes. However, the AM of several promising energy dense materials (conversion electrodes such as iron trifluoride) have yet to be demonstrated or optimized. Furthermore, the integration of multiple AM produced cell components, such as electrodes and separators, along with a custom package remains largely unexplored. In this work, iron trifluoride (FeF 3 ) and ionogel (IG) separators are conformally printed using ME onto non-planar surfaces to enable the fabrication of custom-form Li-FeF 3 batteries. Further, to demonstrate printing on non-planar surfaces, cathodes and separators were deposited onto cylindrical rods using a 5-axis ME printer. ME printed FeF 3 was shown to have performance commensurate with FeF 3 cast using conventional means, both in coin cell and cylindrical rod formats, with capacities exceeding 700 mAh/g on the first cycle and ranging between 600 and 400 mAh/g over the next 50 cycles. Additionally, a ME process for printing polyvinylidene fluoride-co-hexafluoropropylene (PVDF-HFP) based IGs directly onto FeF 3 is developed and enabled using an electrolyte exchange process. In coin cells, this process is shown to produce cells with similar capacity to cells built with Celgard separators out to 50 cycles, with the exception that cycling instabilities are observed during cycles 8–20. When using printed and exchanged IGs in a custom cylindrical cell package, 6 stable high-capacity cycles are achieved. Overall, this work demonstrates approaches for producing high-energy-density Li-FeF 3 cells in coin and cylindrical rod formats, which are translatable to customized, arbitrary geometries compatible with ME printing and electrolyte exchange.

25 ENERGY STORAGE↗

A hybrid 3D/2D field response calculation for liquid argon detectors with PCB based anode plane

Liquid Argon Time Projection Chamber (LArTPC) technology is commonly utilized in neutrino detector designs. It enables detailed reconstruction of neutrino events with high spatial precision and low energy threshold. Its field response (FR) model describes the time-dependent electric currents induced in the anode-plane electrodes when ionization electrons drift nearby. An accurate and precise FR is a crucial input to LArTPC detector simulations and charge reconstruction. Established LArTPC designs have been based on parallel wire planes. It allows accurate and computationally economic two-dimensional (2D) FR models utilizing the translational symmetry along the direction of the wires. Recently, novel LArTPC designs utilize electrodes formed on printed circuit board (PCB) in the shape of strips with through holes. The translational symmetry is no longer a good approximation near the electrodes and a new FR calculation that employs regions with three dimensions (3D) has been developed. Extending the 2D models to 3D would be computationally expensive. Fortuitously, the nature of strips with through holes allows for a computationally economic approach based on the finite-difference method (FDM). In this paper, we present a new software package pochoir that calculates LArTPC field response for these new strip-based anode designs. This package combines 3D calculations in the volume near the electrodes with 2D far-field solutions to achieve fast and precise field response computation. We apply the resulting FR to simulate and reconstruct samples of cosmic-ray muons and 39 Ar decays from a Vertical Drift (VD) detector prototype operated at CERN. We find the difference between real and simulated data within 5%. Current state-of-the-art LArTPC software requires a 2D FR which we provide by averaging over one dimension and estimate that variations lost in this average are smaller than 7%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advanced Dependent Pressure Vessel (DPV) nickel-hydrogen spacecraft cell and battery design

The dependent pressure vessel (DPV) nickel-hydrogen (NiH2) battery is being developed as a potential spacecraft battery design for both military and commercial satellites. Individual pressure vessel (IPV) NiH2 batteries are currently flying on more than 70 Earth orbital satellites and have accumulated more than 140,000,000 cell-hours in actual spacecraft operation. The limitations of standard NiH2 IPV flight battery technology are primarily related to the internal cell design and the battery packaging issues associated with grouping multiple cylindrical cells. The DPV cell design offers higher specific energy and reduced cost, while retaining the established IPV NiH2 technology flight heritage and database. The advanced cell design offers a more efficient mechanical, electrical and thermal cell configuration and a reduced parts count. The internal electrode stack is a prismatic flat-plate arrangement. The flat individual cell pressure vessel provides a maximum direct thermal path for removing heat from the electrode stack. The cell geometry also minimizes multiple-cell battery packaging constraints by using an established end-plateltie-rod battery design. A major design advantage is that the battery support structure is efficiently required to restrain only the force applied to a portion of the end cell. As the cells are stacked in series to achieve the desired system voltage, this increment of the total battery weight becomes small. The geometry of the DPV cell promotes compact, minimum volume packaging and places all cell terminals along the length of the battery. The resulting ability to minimize intercell wiring offers additional design simplicity and significant weight savings. The DPV battery design offers significant cost and weight savings advantages while providing minimal design risks. Cell and battery level design issues will be addressed including mechanical, electrical and thermal design aspects. A design performance analysis will be presented at both the cell and battery level. The DPV is capable of delivering up to 76 Watt-hours per kilogram (Wh/kg) at the cell level and 70 Wh/kg at the full battery level. This represents a 40 percent increase in specific energy at the cell level and a 60 percent increase in specific energy at the battery level compared to current IPV NiH2 technology.

Coates, Dwaine↗

Design of a Second Generation Electrostatic Precipitator for Martian Atmospheric Dust Mitigation of ISRU Intakes

A second generation electrostatic precipitator for use in the Martian environment has been developed by the Electrostatics and Surface Physics Laboratory (ESPL) at NASA Kennedy Space Center (KSC). This new system was designed to be modular and has three interchangeable test sections, each with a variety of replaceable high voltage electrodes, enabling optimization of the dust collection efficiency of the precipitator. It has the ability to maintain an increased atmospheric flow rate and provide more accurate dust delivery into the test section than was available in the previous prototypes. A majority of the controls for the system are provided by a software package developed to maintain a constant flow rate, low pressure, and electrode current to enable long duration performance characterization. This allows for testing of the technology in a relevant environment similar to those expected to be found in an atmospheric In-Situ Resource Utilization (ISRU) plant on Mars.

Precipitator↗

Thick Electrode Design for Facile Electron and Ion Transport: Architectures, Advanced Characterization, and Modeling

The demand for lithium ion batteries continues to expand for powering applications such as portable electronics, grid-scale energy storage, and electric vehicles. As the application requirements advance, the innovation of lithium ion batteries toward higher energy density and power output is required. Along with the investigation of new materials, an important strategy for increasing battery energy content is to design electrodes with high areal loading to minimize the fraction of nonactive materials such as current collectors, separators, and packaging components, resulting in significant gains in energy content and the reduction of the system-level cost. However, the adoption of thick high areal loading electrodes has been impeded by sluggish charge transport and mechanical instability. With conventional slurry cast electrodes, battery function significantly deteriorates with increases in electrode thickness due to high cell polarization and the incomplete utilization of active materials. Thus, a consideration of approaches that facilitate an understanding and eventual adoption of high-loading electrodes is warranted to enable the deliberate advancement of next-generation batteries. Herein, this Account considers three aspects critical to the science and technology of thick high-loading electrodes. The first discussion covers recent approaches to the design and fabrication of high-loading electrodes. Ensuring electrical contact throughout the electrode is accomplished through the manipulation of conductive additives or using a conductive scaffold within the electrode. Ion transport can be facilitated through electrode design and fabrication approaches that deliberately control the electrode porosity and tortuosity. Second, advanced characterization methodologies are presented as the ability to determine the origins of transport limitations provide the insight needed to deliberately approach future designs. Spectroscopic and diffraction methods have been used to characterize the 2D and 3D pore structure and composition of the electrodes. Furthermore, operando methods that yield spatially and temporally resolved information regarding the progression of the electrochemical reaction are highlighted. The third aspect considered is the utilization of modeling. Physically based continuum models linked with the results of experimental characterization have been demonstrated and then allow the rapid simulation of a variety of deliberate electrode designs and their impacts on functional electrochemistry. Variables relevant to the designs can be tested by the model under a series of use conditions to identify those of most promise for a specific application. Finally, an outlook on future opportunities for high-loading battery electrode research is provided to inform and entice practitioners in the field to pursue these important directions of inquiry.

25 ENERGY STORAGE↗

Macromolecules & Manufacturing Science

Outline • SRNL Overview • Mission overview • Polymers enabling the mission • R&D Highlights • Polymers in radiation environments • Tooling in shielded cells • Packaging for nuclear material shipments • Polymers supporting tank waste remediation • Ref electrode • Epoxy and polymer grout • Polymers for fusion energy • Deuterium labelling • Polymers for additive manufacturing • Coalescence and blends: experimental and predictive • Process modelling and sorting through big data (peregrine and latticeJ)

Chatham, Camden [Savannah River National Laborator↗