Electrolyzers in focus: advances in CO 2 electrolyzer designs

Electrochemical CO 2 reduction (ECR) remains a viable method to reintegrate anthropogenic CO 2 into current energy infrastructures through its conversion into commodity chemicals. To facilitate the integration of ECR, electrochemical devices called electrolyzers must be implemented to overcome the inherent limitations that exist in current ECR experiments, namely kinetics and mass transport. In this review, we outline the current and advancing designs in ECR electrolyzers, with a focus on the following five electrochemical devices: membrane electrode assemblies (MEA), flow cell (FC), rotating disk electrode (RDE), rotating ring-disk electrode (RRDE), and rotating cylinder electrode (RCE). We highlight the tunable components of each electrolyzer with a forward outlook on the optimization and relevance of electrolyzer designs in upcoming ECR applications.

CO2 reduction

Manufacturing Cost Analysis for PEM Electrolyzers and Perspectives for Future Cost Reduction

Electrolyzer capital costs strongly influence the total levelized cost of hydrogen production and have implications for hydrogen deployment. Current electrolyzer costs are high, and large cost reductions may be needed to achieve competitive hydrogen costs and targets. Understanding pathways for cost reduction via R&D and deployment is a critical research area for informed energy planning and enabling hydrogen use. This work presents bottom-up cost estimates of polymer electrolyte membrane (PEM) electrolyzer systems tied to design specifications and discusses perspectives for cost reduction opportunities based on ongoing research. We use a detailed manufacturing and process model for a 1 MW PEM electrolyzer stack and balance of plant (BOP) for rigorous cost estimation. This allows for robust estimates of component and manufacturing costs and examination of key cost contributors. Stack costs are dominated by material costs such as iridium and platinum catalysts, especially at high manufacturing rates; power electronics and hydrogen purification equipment are the largest contributors to BOP cost. At higher manufacturing rates, better equipment utilization could reduce stack costs significantly, and we estimate that experience and bulk purchasing will allow for cost reductions to some BOP components. Still, many well-established BOP technologies and stack material costs are less likely to see significant cost reductions at high manufacturing rates. As such, manufacturing scale is limited in how much it can reduce electrolyzer costs, and additional advances for cost reduction may be needed to achieve cost targets. It will likely take many combined strategies to achieve significant cost reductions for electrolyzers and enable low-cost hydrogen production. We can use our manufacturing cost model to quantify potential cost reductions from the considerations described above and demonstrate pathways to lower cost electrolyzers. This allows for better understanding of cost reduction strategies and enables more informed research, development, and deployment for electrolyzers.

cost

Findings from Large Bench-Scale Testing of Denitration Electrolyzers for the EDCGe Project

This report highlights the key findings and outcomes relevant to the processability of waste supernatant at Hanford using a denitration electrolyzer. The Electrosynthesis Company issued a Phase 1 report to the Savannah River National Laboratory (SRNL), summarizing the evaluation of large bench-scale denitration electrolyzers to support the electrochemical denitration and caustic generation (EDCGe) project. The Electrosynthesis Company’s report (attached as Appendix A) provides insights into the initial steps required to implement an electrolyzer system at Hanford. Phase 1 experiments focused on validating the denitration electrolyzer’s performance, operating parameters, and reaction products. The robustness of the electrochemical denitration process was demonstrated by two electrolyzer flow cell systems (a 100 cm 2 ElectroCell MP and a 150 cm 2 NESI NS01 cell), both of which achieved significant nitrate and nitrite removal (>50%) with a current efficiency of ~95% for both systems. Higher current densities (500 mA cm –2 ) improved nitrate and nitrite removal rates compared to lower current densities (333 mA cm –2 ), while maintaining a current efficiency of ~94%. The NS01 cell achieved a nitrate species removal rate of ~0.41 mol h –1 at 5 kA m –2 (equiv. to 500 mA cm –2 ). The primary reaction product was ammonia (NH 3 ), constituting 78.3–91.6% of the products (excluding OH – formation). NH 3 was predominantly retained in the catholyte liquid phase rather than being off-gassed. Additionally, the NS01 cell reported an NH 3 generation rate of ~0.36 mol h –1 at 5 kA m –2 . Other gas formation included ~7% N 2 , ~7% H 2 , and trace amounts of N 2 O. The estimated power requirement (extrapolated from the 0.015 m 2 cell data) for a full-scale denitration electrolyzer is approximated to be ~1.6 MW (DC-only) to treat 50% of nitrate and nitrite in a waste stream and generates ~2.1 kmol h –1 of NH 3 with an initial concentration of 4 M NO 3 – /NO 2 – at 300 gal h –1 . Simulated waste containing aluminate, carbonate, oxalate, and halogens exhibited no adverse effects on denitration performance. A preliminary experiment comparing alkaline anolyte (5 M NaOH) with a nickel based anode to acidic media (2 M H 2 SO 4 ) with a DSA-O 2 anode showed a lower operating voltage and generated less H 2 than the acid media. Maintaining a stable 5 M OH – concentration in the anolyte through periodic additions of caustic did not significantly impact denitration performance. This operational mode will be required for long-term experiments. All the experiments demonstrated that electrochemical denitration is a promising approach for treating nitrate and nitrite in simulated waste streams, achieving significant conversion and robustness across varying experimental conditions and electrochemical cell configurations. Lastly, the ability to generate a nearly pure NH 3 stream may prove advantageous for processing at other locations within the Hanford site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Using X-ray radiography to study oxygen flow in a proton exchange membrane electrolyzer operating under balanced pressure conditions

Of the various water electrolyzer technologies, the proton exchange membrane electrolyzer (PEMWE) is one of the best solutions for producing clean hydrogen without releasing CO 2 . In order to allow for widespread use of clean hydrogen, it is necessary to decrease its cost, which is intrinsically related to system operation. Current PEMWE plants operate in differential mode, directly pressurizing hydrogen and benefiting from thermodynamic compression, which increases overall system efficiency. However, high differential pressure above 30 bar can cause membrane stress, resulting in membrane creeping and failure. Pressurizing the water and operating at balanced pressure allows hydrogen to be produced at higher pressures while preserving the integrity of the membrane and porous layers. Nevertheless, the impact of pressurizing water on PEMWE performance must be better understood to maximize performance under balanced pressure conditions. Here, this study examined the impact of water pressure on two-phase flow. A high-pressure electrolyzer setup was developed to perform operando X-ray radiography and examine oxygen transport with high temporal resolution. The imaging segmentation process, developed to capture bubble properties in the channel, was applied to a specific experiment. The results clearly showed that as pressure increased up to 30 bars, the initial bubbly flow transitioned to slug flow, which led to channel saturation with oxygen. This work demonstrates that two-phase flow in an electrolyzer can be studied using X-ray radiography, which has the advantages of fast measurements and the ability to probe dense materials, such as those required for pressurized electrolyzers.

Balanced high pressure operation

Comparing Intrinsic Catalytic Activity and Practical Performance of Ni- and Pt-Based Alkaline Anion Exchange Membrane Water Electrolyzer Cathodes

The stringent cost and performance requirements of renewable hydrogen production systems dictate that electrolyzers benefit from the use of nonprecious catalysts only if they deliver the same level of activity and durability as their precious metal counterparts. Here we report on recent work to understand interrelationships between the intrinsic activity of Ni- and Pt-based electrolyzer cathode catalysts and their performance in zero-gap alkaline water electrolyzer assemblies. Our results suggest that nanoparticulate Ni–Mo exhibits HER activity that is roughly 10-fold lower than Pt–Ru on the basis of turnover frequency under low (≤100 mV) polarization conditions. We further found that the HER activity of Ni–Mo/C cathodes is inhibited by aryl piperidinium anionexchange ionomers bearing bicarbonate counter-anions. After addressing this poisoning effect, we produced electrolyzer assemblies based on Ni–Mo/C cathodes that delivered indistinguishable current density vs cell potential relationships compared to otherwise identical assemblies with Pt–Ru cathodes. This result indicates that the contribution of the cathode to the total cell polarization is small, even for the less active Ni–Mo/C catalyst, and further implies that Pt-based cathodes can indeed be replaced by nonprecious alternatives with no loss in performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Green Methanol via an Integrated Direct Air Capture, CO 2 Electrolyzer, and Hydrogenation Reactor

This project pioneered a groundbreaking reactor design to produce green methanol by harnessing the electrochemical CO 2 reduction reaction (eCO 2 RR), a cornerstone of power-to-fuels technology. The effort integrated three innovative technologies to achieve carbon-neutral methanol production at a target cost of under $\$$800/ton: 1. Direct Air Capture (DAC): Using a cutting-edge sorbent material developed at Holocene, scalable models were developed to integrate captured atmospheric CO₂ into the reactor system. 2. Intermediate-Temperature CO 2 Electrolyzer: Developed by the University of Tennessee (UTK), this electrolyzer utilizes a cost-effective, proton-conducting solid acid electrolyte (CsH 2 PO 4 , CDP) and a mixed-metal oxide cathode. It achieves high faradaic efficiencies (>98%) by effectively suppressing hydrogen evolution at high current densities, converting CO 2 to CO with remarkable selectivity. 3. Catalysis and Reactor Engineering: Oak Ridge National Laboratory (ORNL) contributed world-class expertise in heterogeneous catalysis and reactor design. Their advanced ASPEN modeling drove systems integration and supported techno-economic and life cycle analyses. This effort was further bolstered by partnerships with industry leaders Air Company and Plug Power, who provided critical guidance on scaling, systems engineering, and the integration of water electrolyzers into large-scale operations. During Phase 1, the team focused on modeling and validating a lab-scale reactor demonstrating the feasibility of the integrated approach. Key accomplishments include a 52% increase in current density at 0.8 V while maintaining >98% CO faradaic efficiency, successful 10× scale-up of the electrolyzer with performance within 5% of coin-cell results, best-in-class durability (168-hour test at 0.6 V with 0.14 mA/cm 2 -h degradation), validated TEA confirming the $\$$800/ton methanol target, and completed preliminary LCA showing potential for net-negative GHG emissions under renewable energy scenarios.

10 SYNTHETIC FUELS

Demonstration of Electrolyzer Operation at a Nuclear Plant to Allow for Dynamic Participation in an Organized Electricity Market and In-House Hydrogen Supply

This document details the execution of Cooperative Agreement DE-EE0008849, “demonstration of electrolyzer operation at a nuclear plant to allow for dynamic participation in an organized electricity market and in-house hydrogen supply” during the performance period of 10/1/2019 – 9/30/2024. The project was funded by the U.S. Department of Energy’s Office of Energy Efficiency and Renewable Energy (EERE). Constellation Energy Generation, LLC (formerly Exelon Generation Company, LLC) is the prime recipient of the award. Other members of the project team are INL, NREL, ANL and Nel Hydrogen. The main project objective was to demonstrate an end-to-end integrated grid-scale carbon-free H 2 production, storage and utilization pilot plant at a nuclear generating facility. The project also aimed to evaluate market opportunities and regulatory requirements related to the participation of integrated hydrogen production and nuclear plant facilities in organized power markets, by demonstrating dynamic control and operation of the electrolyzer and assessing the economics of dynamic participation combined with the revenue streams from hydrogen production. On March 7th , 2023 Constellation started hydrogen production at it’s Nine Mile Point Nuclear Plant in Oswego, New York. The PEM electrolyzer operating at Nine Mile Point uses 1.25 megawatt of nuclear electricity to produce 560 kilograms of clean hydrogen per day, more than enough to meet the plant’s operational hydrogen use. It will also help set the stage for possible large-scale deployments at other clean energy centers in Constellation’s fleet that would couple clean hydrogen production with storage and other on-site uses. Employing the lessons learned from the 1.25 MW demonstration-scale, nuclear-powered clean hydrogen production facility at Nine Mile Point, Constellation was a major participant in the MachH2 hydrogen hub recently selected for up to $\$$1 billion by the Department of Energy (DOE) as part of the bipartisan Infrastructure Investment and Jobs Act. Constellation will use a portion of the hub funding to build the world’s largest nuclear-powered clean hydrogen production facility at its LaSalle Clean Energy Center in Illinois. The project was featured in a number of news articles and press releases and received 2 awards. At the 2023 DOE HFTO’s Annual Merit Review meeting, the P.I. Dr. Uuganbayar Otgonbaatar and project manager Robert Beaumont were recognized for “outstanding achievements in the development and demonstration of a first-of-a-kind clean hydrogen production facility, powered by carbon-free nuclear energy, at the Nine Mile Point Nuclear Station in Oswego, New York.” The project was also awarded 2023 Nuclear Energy Institute’s Top Innovative Practice award.

08 HYDROGEN

Innovative Method for Reliable Measurement of PEM Water Electrolyzer Component Resistances

Understanding the sheet resistance of porous electrodes is essential for improving the performance of polymer electrolyte membrane (PEM) water electrolyzers and related technologies. Despite its importance, existing methods often fail to provide reliable and comprehensive data, especially for porous materials with complex morphologies and non‐uniform thicknesses. This study introduces a robust and straightforward method for determining the sheet resistance of porous electrodes using a novel probe concept based on industrial printed circuit board (PCB) technology. This probe measures resistance across ten distances, ranging from 250 µm to 2500 µm, enabling local mapping of resistance. The study focuses on the sheet resistance of key components in PEM water electrolyzers, including the gas diffusion layer (GDL), porous transport layer (PTL), and catalyst layers deposited on a membrane. Additionally, an image‐processing‐based method is presented to obtain the thickness distribution of the studied catalyst layers, facilitating a detailed analysis of the electrical in‐plane resistivity with thickness variations. Overall, this methodology has the potential to expedite material integration and bridge the gap between electrode engineering and single‐cell testing, thereby advancing the development of PEM water electrolyzers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Cost estimation of balance of plant equipment scale up for proton exchange membrane water electrolyzer systems

Water electrolyzers that use electricity to split water into hydrogen and oxygen could be a key technology for increasing hydrogen supply to meet expanded and emerging market applications, although currently the capital costs of these electrolyzers are high. Here we examine cost reductions that might be achieved by scaling up proton exchange membrane (PEM) electrolyzer systems and leveraging economies of scale through balance of plant (BOP) components for system sizes between 1 MW and 1 GW. We estimate BOP equipment capital costs of about $\$$848/kW at 1 MW, potentially decreasing to $\$$87/kW at 1 GW (2022-dollar year basis) with most of the cost reduction happening as systems scale from 1 MW to 100 MW. We find that BOP subsystems hydrogen drying and water knockout benefited the most from economies-of-scale cost reductions, and piping, instrumentation, and housing and power electronics were less impacted. These cost reductions from economies of scale could be more significant than estimated cost reductions from manufacturing scale-up reported in literature. These results add to the knowledge base that could guide optimal system designs that balance process scale-up with plant modularization and numbering-up. We also estimate that scaling up BOP could potentially lower the levelized cost of hydrogen (LCOH) by $\$$1.7-$\$$4.6/kg, depending on the scale-up magnitude and the plant capacity factor.

08 HYDROGEN

Understanding Inlet Concentration Effects on the Electrocatalytic Conversion of CO 2 to Formic Acid in Gas-Fed Electrolyzers

The electrochemical CO 2 reduction reaction (CO2RR) to produce value-added products remains a developing technology for utilizing waste CO 2 streams. Most device-level CO2RR studies use pure CO 2 gas feeds; however, the effect of dilute CO 2 on the electrolyzer performance is an important consideration for large-scale electrolyzer operation, single-pass conversion, and real-world CO 2 source utilization. This work investigates the effect that the CO 2 concentration has on the performance of formic acid (HCOOH) producing tin oxide (SnO 2 ) and bismuth oxide (Bi 2 O 3 ) catalysts in an electrolyzer device setting. Surprisingly, SnO2 demonstrated an approximately 20% increase in HCOOH selectivity (Faradaic efficiency) when the CO 2 concentration decreased from 100 to 20%. In contrast, Bi 2 O 3 consistently demonstrated high selectivity toward HCOOH across the same CO 2 concentration range. The effects of the CO 2 concentration on selectivity were further investigated with half-cell experiments and in situ Raman spectroscopy, which revealed dynamic changes in the cathodic overpotential and chemical state of the catalyst that depended on the CO 2 concentration. Density functional theory calculations showed how changes in the surface oxidation state of Sn, varying from fully oxidized SnO 2 to metallic Sn(0), affect the thermodynamic barriers of the three main observed products: HCOOH, CO, and H 2 . Our results indicate that dilute CO 2 concentrations required larger cathodic overpotentials to sustain a fixed current density, which, in turn, pushed the Sn-based catalyst toward a more reduced surface that was favorable to HCOOH formation. On the other hand, the Bi-based catalyst remained in a metallic state at CO2RR-relevant potentials and demonstrated a consistent product selectivity regardless of CO 2 concentration. These findings highlight how varying the CO 2 inlet gas concentrations affects the chemical state of catalysts and the resulting performance metrics.

42 ENGINEERING

A harmonized protocol to assess the single-cell performance of proton exchange membrane water electrolyzers

The harmonization of testing protocols for proton exchange membrane (PEM) electrolyzers is essential for ensuring accurate and reliable performance assessments and accelerating the development of hydrogen production technologies. This protocol provides a structured approach to PEM electrolyzer setup and testing, incorporating key considerations for test station design and single-cell characterization techniques. Polarization curves and electrochemical impedance spectroscopy (EIS) are detailed, along with best practices from academic and industry research groups to enhance data accuracy and comparability. By addressing material variability and harmonizing testing methodologies, this framework enables more precise evaluations of membrane electrode assemblies and electrolyzer components. Harmonized protocols not only streamline development efforts but also foster collaboration across institutions, ultimately supporting the commercialization of hydrogen solutions through improved stack efficiency and durability.

08 HYDROGEN

Reports from the Frontier: Understanding Voltage Losses in Anion Exchange Membrane Water Electrolyzers

With the growth of renewable energy sources, hydrogen is attracting significant attention worldwide as an effective medium for energy storage. “Green hydrogen” is currently produced primarily by water electrolysis in which water is split into hydrogen and oxygen using power from low-carbon energy sources such as wind, solar, and nuclear. Among the low temperature water electrolysis technologies, anion exchange membrane water electrolyzers (AEMWEs) have recently emerged as a promising competitor to traditional alkaline water electrolyzers (AWEs) and proton exchange membrane electrolyzers (PEMELs) due to their potential stack cost reduction in various cell components. In conclusion, favorable aspects of AEMWEs include the use of PGM-free electrocatalysts as well as low-cost membranes, bipolar plates (BPs), and porous transport layers while offering high voltage efficiency and durability.

08 HYDROGEN

Fractional capacity electrolyzer development for CO2 and H2O electrolysis

The electrolyzer module was designed to produce 0.24 kg/d (0.53 lb/d) of breathable oxygen from the electrolysis of metabolic carbon dioxide and water vapor. The fractional capacity electrolyzer module is constructed from three electrochemical tube cells and contains only three critical seals. The module design illustrated an 84 percent reduction in the total number of seals for a one person capacity oxygen generating system based on the solid electrolyte carbon dioxide and water vapor electrolysis concept. The electrolyzer module was successfully endurance tested for 71 days.

Wynveen, R. A.

Integration of hydrophobic gas diffusion layers for zero-gap electrolyzers to enable highly energy-efficient CO 2 electrolysis to C 2 products

Electrochemical CO 2 reduction (eCO2R) is an attractive route for mitigating global CO 2 emissions while producing value-added chemicals. Ethylene is one product of eCO2R and is an essential industrial precursor with a global market of $230 billion. The large-scale implementation of C 2 H 4 -selective CO 2 electrolyzers remains challenging because of low energy efficiencies. In this work, we develop the design principles necessary for incorporating an expanded polytetrafluoroethylene (ePTFE) electrode into a zero-gap electrolyzer while simultaneously developing an integrated electrical front contact that reduces the ohmic resistances inherent to electrically insulating gas diffusion layers. By co-designing the catalyst layer, gas diffusion medium, and operating conditions for a zero-gap ePTFE gas diffusion electrode (GDE), we achieved a full-cell voltage of 2.5 V at 200 mA cm −2 at 25 cm 2 geometric area cell with Faradaic efficiencies of 48% for ethylene and 40% for ethanol. This work highlights strategies for developing a scalable, stable, and highly energy-efficient eCO2R for C 2 products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Two-phase flow numerical analysis of electrode geometry for alkaline water electrolyzers

Hydrogen is a promising component of a future energy-secure and efficient economy, but its competitiveness depends on reducing production costs. One strategy is to operate alkaline water electrolyzers at higher current densities to increase output. However, this intensifies performance losses due to gas bubble accumulation, which blocks transport pathways and deactivates electrochemically active surfaces. Enhancing bubble evacuation through electrode design is therefore essential. Previous studies have explored various approaches — such as modifying surface morphology, applying sonication or pressure modulation, and introducing surfactants — but these efforts have addressed a limited range of conditions due to the complexity of two-phase flow and electrode geometries. Experiments have also largely been focused on either cell level improvements, which lack the information necessary to isolate each contributing factor, or on modified geometries that are not relevant to practical cell operation. From a modeling perspective, conventional Eulerian multiphase models do not track the complex gas–liquid interfacial dynamics and often neglect surface tension and contact angle effects, reducing their predictive accuracy. To provide insights on the effects of different electrode geometries on the performance of alklaine water electrolyzers this work employs an immersed boundary volume-of-fluid method to simulate bubble behavior in 3D porous electrodes. Multiple base electrode geometries, typically used in practice, with varying porosity are evaluated under a constant surface gas generation rate. Simulation data is analyzed to quantify electrode gas coverage, bubble size dynamics and other relevant metrics. Results show that porosity strongly influences bubble accumulation on electrode surfaces, with higher porosity reducing gas coverage, and its not strictly dependent on the electrode geometry. However, the electrode’s base geometry significantly affects gas accumulation at the separator gap, independent of porosity. A foam electrode geometry resulted in the lowest gas coverage of all electrodes with a median volumetric gas coverage of 11%, but at the cost of a 70% reduction in active area compared with the largest surface area electrode, while gyroid electrodes showed the best trade-off between gas coverage, particularly at the separator surface, and electrochemically active area. In conclusion, the results highlight the need for holistic electrode design strategies.

Alkaline

Activity Convergence between Continuous- and Pulsed-Deposition NiFe Hydroxide Anodes in Liquid Alkaline Electrolyzers

Improving the activity of anodes for the alkaline oxygen evolution reaction (OER) is of interest because of the importance of the reaction in electrochemical technology. There is an abundance of studies which confirm that NiFe hydroxide, often prepared by electrodeposition, is the most active catalyst for the alkaline OER. This relatively high level of confidence in the optimal OER catalyst chemistry suggests that exploration of methods which improve on features besides the chemistry of the films, such as their microstructure, could access new heights of activity. In this study, the possible benefits of pulsed current deposition relative to the conventional continuous current approach to the deposition of NiFe hydroxides were investigated. Pulsed deposition densified the film surfaces by preventing metal ion depletion at the electrode surface during film formation. The Fe content, redox reversibility, and OER activity were higher for the pulsed deposition films relative to their continuous deposition counterparts. Though pulsed deposition imparted a higher OER performance of the films compared to continuous deposition at the three-electrode level, this improved performance was not retained during electrolyzer operation. Rather, a convergence of the cell performance is seen irrespective of the deposition approach. This phenomenon was attributed to the way electrolyzer conditionsrelatively high temperature, base concentration, and current densitycan drive alternate mechanisms for observed performance.

08 HYDROGEN

Advanced PEM Electrolyzer Membrane for Hydrogen Crossover Mitigation

An unintended reaction in the electrochemical conversion of water to hydrogen in proton exchange membrane (PEM) electrolyzers is the crossover of hydrogen from the anode to the oxygen-containing cathode through the membrane, creating hydrogen losses and safety concerns. Efforts to date have focused on embedding platinum catalysts in perfluorosulfonic (PFSA) membranes to convert H 2 to protons. The objective of this project is to design and develop hydrocarbon (HC) proton exchange membranes (PEMs) that can help overcome the risk of high H 2 crossover in current PEM electrolyzer (ELX) stacks by designing and optimizing the gas recombination catalyst (GRC) within the membrane and membrane electrode assembly (MEA) structure.

08 HYDROGEN