Autonomous Inverter Controls for Resilient and Secure Grid Operation: Vector Control Design for Grid Forming

The project addresses both fundamental and practical challenges of GFM/GFL inverter control for the power grids with high inverter based resources (IBRs) penetration. A data- driven modeling technique is applied to accurately model dynamics of PWM inverters, including electromagnetic-transient (EMT). Systematic and integrative designs of grid- forming (GFM) and grid-following (GFL) primary controls are developed to guarantee system performance under either normal or abnormal operating conditions without violating constraints. This modeling and control framework provides black-start capability in case of an outage without relying on rotating generators, and its secondary control is also shown to enhance resilience against cyber-physical attacks.

14 SOLAR ENERGY↗

Modeling of Inductive Constant Power Load for Electromagnetic-Transient Simulations-Part II

This paper improves the dynamic constant power (CP) load model that was published in Part I, which is appropriate for electromagnetic-transient (EMT). The improved model conserves all features of its predecessor. For instance, it maintains a fixed power consumption (both active and reactive parts) and a fixed power factor for loads that are predominantly inductive. Furthermore, as the proposed model is a time-dependent system, it is applicable to both sinusoidal and non-sinusoidal case studies. However, the previous model cannot be easily integrated with numeric solvers because it simulated load data over one cycle all together, not sequentially in a time-step manner, due to the limitation involved with the power factor. The improved version, on the contrary, allows the load to be simulated at every time step, which would facilitate its integration with numeric solvers. The model's validity is confirmed by comparing its response with data that is synthesized from constant impedance load, and the result is satisfactory.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Digital Filter Design for Point-on-Wave Sensors: Highlighting Frequency Response Limitations and Enhancing Grid Simulation Accuracy

Data is proving to be the backbone of today's and, more importantly, tomorrow's grid. As the system changes and introduces fast-acting devices like power electronics, overall observability tends to decrease from the utility point-of-view. This can be mitigated by adding more high-fidelity sensors onto the grid, although this incurs a cost. These sensors are never ideal, and each have unique frequency responses that may influence the data produced. This may, in turn, impact the protection and control of the power grid. This paper presents a methodology of representing these point-on-wave sensors digitally by estimating digital-filter representations of them, thereby introducing means of improving the sensor models used in electromagnetic-transient (EMT) simulations. This may help with identifying potential high-frequency, sensor-induced distortions, and system resonance compensation. Three commercial-grade medium-voltage point-on-wave sensors are utilized in a lab environment to obtain experimental frequency responses with a frequency sweep, and it is shown that both Infinite Impulse Response (IIR) and Finite Impulse Response (FIR) filter representations may approximate these responses with varying degrees of accuracy, though each has their own strengths and weaknesses. It is found that, in general, FIR estimation better approximates these sensors than IIR estimation does.

Wilson, Aaron [ORNL] (ORCID:0000000327331697)↗

Equivalent-Circuit Models of Grid-Forming IBRs for Electromagnetic-Transient Simulations

We derive equivalent-circuit models of control- and physical-layer subsystems of grid-forming (GFM) inverter-based resources (IBRs) for electromagnetic-transient (EMT) simulations. Three different primary controllers are considered: Droop, Virtual Synchronous Machine (VSM), and dispatchable Virtual Oscillator Control (dVOC). In addition, the models include cascaded voltage- and current-control loops, and LCL output filters. Simulations for a single-inverter setup and for a network of five inverters in a modified IEEE 14-bus topology are presented. The equivalent-circuit models simulated with analog electronic circuit-simulator software (in our case, LTspice) offer the same accuracy, and with no explicit tuning of the solver, lower computational burden compared to block-diagram-based implementations in commercial off-the-shelf EMT software (in our case, MATLAB-Simulink).

electromagnetic transient simulation↗

Equivalent-Circuit Models of Grid-Forming IBRs for Electromagnetic-Transient Simulations: Preprint

We derive equivalent-circuit models of control- and physical-layer subsystems of grid-forming (GFM) inverter-based resources (IBRs) for electromagnetic-transient (EMT) simulations. Three different primary controllers are considered: droop, virtual synchronous machine (VSM), and dispatchable virtual oscillator control (dVOC). In addition, the models include cascaded voltage- and current-control loops, and LCL output filters. Simulations for a single-inverter setup and for a network of five inverters in a modified IEEE 14-bus topology are presented. The equivalent-circuit models simulated with analog electronic circuit-simulator software (in our case, LTspice) offer the same accuracy with up to 150x lower computational burden compared to block-diagram-based implementations in commercial off-the-shelf EMT software (in our case, MATLAB-Simulink).

circuit-equivalent model↗

Equivalent-Circuit Models for Grid-Forming Inverters under Unbalanced Steady-State Operating Conditions: Preprint

Positive- and negative-sequence equivalent-circuit models are put forth to capture the operation of grid-forming (GFM) inverters in unbalanced steady-state operating conditions acknowledging the impact of current limiting. The particular control architecture examined adopts droop control (for primary control), nested inner-current and outer-voltage control (in the stationary reference frame), and it is adaptable to two different types of current limiting (current-reference saturation and virtual-impedance limiting). We anticipate the proposed models to be of interest in modeling, analysis, and simulation of GFM inverters in unbalanced settings that may arise, e.g., in the face of faults. Validation of the equivalent-circuit models is pursued via comparison with full-order electromagnetic-transient (EMT) simulations for representative balanced and unbalanced faults.

equivalent-circuit models↗

Novel Real- Time EMT- TS Modeling Architecture for Feeder Blackstart Simulations

This paper presents the development and benchmarking of a novel real-time electromagnetic-transient and transient-stability (EMT-TS) modeling architecture for distribution feeder restoration studies. The work presents for the first time in the literature a real-time EMT-TS testbed in which the grid-forming unit is simulated in EMT domain, operating as the slack bus of the phasor domain while including unbalanced voltage conditions. To evaluate the performance and limitations of the proposed model, an equivalent EMT testbed is developed to serve as a benchmark. First, the co-simulation framework and the domain coupling methodology are introduced. Next, the steady state operation of the EMT-TS and EMT models are matched. Then, tests are conducted to analyze the transient performance of the proposed EMT-TS model when compared to its EMT benchmark. Results reveal that when utilizing a battery energy storage system (BESS) as the grid-forming unit, the EMT-TS testbed can maintain high accuracy for typical load steps.

Paduani, Victor↗